MRVINREACH :: slotAdminAction

MIB Reference — IPNetwork Monitor · Updated September 12, 2026

All MIBsMRVINREACHslotAdminAction

slotAdminAction

Module: MRVINREACH

OID (symbolic): MRVINREACH::slotAdminAction

OID (numeric): 1.3.6.1.4.1.33.16.7.1.1.2

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Control to cause reset of the system in a slot. When read, the value is always 'ready'. Setting to 'reset' or 'resetHold' causes a single attempt to take that action, but does not ensure transition to any particular value of slotOperStatus.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.33.16.7.1.1.2
snmpwalk -v2c -c public <target> MRVINREACH::slotAdminAction

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.33.16.7.1.1.2.1
snmpget -v2c -c public <target> MRVINREACH::slotAdminAction.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.33.16.7.1.1.2.1 i <value>

Start monitoring MRV Communications In-Reach console/terminal server or power management unit with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the MRVINREACH::slotAdminAction OID value, configure state conditions and alerts, and monitor any MRV Communications In-Reach console/terminal server or power management unit from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.33iTouchITOUCH-MIB
1.3.6.1.4.1.33.16xChassisITOUCH-CHASSIS-MIB
1.3.6.1.4.1.33.16.7xSlotITOUCH-CHASSIS-MIB
1.3.6.1.4.1.33.16.7.1slotTableITOUCH-CHASSIS-MIB
1.3.6.1.4.1.33.16.7.1.1slotEntryITOUCH-CHASSIS-MIB
Numeric OIDNameModule
1.3.6.1.4.1.33.16.7.1.1.2slotAdminActionMRVINREACH