All MIBs › MRVINREACH › paramClientServerCheck
paramClientServerCheck
Module: MRVINREACH
OID (symbolic): MRVINREACH::paramClientServerCheck
OID (numeric): 1.3.6.1.4.1.33.7.6
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Control over whether or not this system is allowed to check for additional parameter servers. 'enabled' allows checking. Corresponds directly to PARAMETER SERVER CHECK and the presence of PARAMETER POLLING under the label 'Enabled Characteristics' in the SERVER CHARACTERISTICS display.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.33.7.6 snmpwalk -v2c -c public <target> MRVINREACH::paramClientServerCheck
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.33.7.6.1 snmpget -v2c -c public <target> MRVINREACH::paramClientServerCheck.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.33.7.6.1 i <value>
Start monitoring MRV Communications In-Reach console/terminal server or power management unit with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the MRVINREACH::paramClientServerCheck OID value, configure state conditions and alerts, and monitor any MRV Communications In-Reach console/terminal server or power management unit from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.33 | iTouch | ITOUCH-MIB |
| 1.3.6.1.4.1.33.7 | xParamClient | ITOUCH-PARAM-CLIENT-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.33.7.6 | paramClientServerCheck | MRVINREACH |