All MIBs › MMB-COM-MIB
Category: Telecom / Multimedia
Description: Defines MMB communication module configuration and interface management objects.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is MMB-COM-MIB?
MMB-COM-MIB is a Fujitsu-specific MIB, part of the PRIMEQUEST server system-management MIB family, that models the chassis/unit inventory and management-network configuration exposed by the Management Board (MMB) service processor. It defines objects such as unitTable (unitModelName, unitManufacturer, unitSerialNumber, unitLocation, frontDoorStatus, housingOpenStatus), the unitParentTable/unitChildTable pair describing chassis-partition hierarchy, and managementNodeTable, which carries the MMB's own network/communication interface configuration (unitNodeAddress, unitNodeIpNetmask, unitNodeGateway, unitNodeMacAddress, unitNodeUseDHCP, unitNodeControllerType/Model/FWVersion) plus a managementChannelType object describing the communication channel in use. This makes the MIB useful for monitoring both the physical/chassis identity of PRIMEQUEST units and the health of the MMB's own management communication path, rather than general OS or application data. It is deployed alongside Fujitsu's broader PRIMEQUEST management MIB set on PRIMEQUEST server chassis, and the MMB-COM-MIB MIB is the reference for the exact object layout of this management-node/communication data.
IPNetwork Monitor allows you to monitor SNMP objects defined in MMB-COM-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Fujitsu PRIMEQUEST server chassis (MMB service processor)
Monitoring Examples
An operator polls managementNodeTable for a given uUnitId to confirm unitNodeAddress and unitNodeGateway match the expected MMB management network configuration and that unitNodeControllerFWVersion is current; a mismatch between the configured unitNodeAddress and the address actually reachable, combined with an unexpected managementChannelType, would indicate the MMB's management communication path has been reconfigured or degraded.
What Can Be Monitored
- unit/chassis inventory table entries
- chassis parent/child partition relationships
- management node network address configuration
- management channel type
- MMB controller type, model, and firmware version
- unit table update counters
This MIB depends on
Imported Objects
From INET-ADDRESS-MIB
| InetAddress | |
| InetAddressType |
From RFC-1212
| OBJECT-TYPE |
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| Counter | |
| Gauge | |
| IpAddress | |
| TimeTicks | |
| enterprises | |
| mgmt |
From RFC1213-MIB
| DisplayString | |
| PhysAddress | |
| mib-2 |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| fujitsu | 1.3.6.1.4.1.211 | |||
| products | 1.3.6.1.4.1.211.1 | |||
| iaServer | 1.3.6.1.4.1.211.1.31 | |||
| primequest | 1.3.6.1.4.1.211.1.31.1 | |||
| mmb | 1.3.6.1.4.1.211.1.31.1.1 | |||
| sysInfo | 1.3.6.1.4.1.211.1.31.1.1.1 | |||
| agentInfo | 1.3.6.1.4.1.211.1.31.1.1.1.1 | |||
| STR agentId | 1.3.6.1.4.1.211.1.31.1.1.1.1.1 | DisplayString | read-only | Agent identification string; Not supported. |
| STR agentCompany | 1.3.6.1.4.1.211.1.31.1.1.1.1.2 | DisplayString | read-only | Agent's company name (e.g. Fujitsu Siemens Computers); Not supported. |
| STR agentVersion | 1.3.6.1.4.1.211.1.31.1.1.1.1.3 | DisplayString | read-only | Agent's version string (e.g. 1.05); Not supported. |
| STR agentBuild | 1.3.6.1.4.1.211.1.31.1.1.1.1.4 | DisplayString | read-only | Compilation time and date of agent program; Not supported. |
| INT agentWriteAllowed | 1.3.6.1.4.1.211.1.31.1.1.1.1.5 | INTEGER | read-only | Defines whether writable objects can be written (except shutdown/power-off operations); Not supported. |
| INT agentShutdownAllowed | 1.3.6.1.4.1.211.1.31.1.1.1.1.6 | INTEGER | read-only | Defines whether shutdown/power-off objects can be written; Not supported. |
| unitInformation | 1.3.6.1.4.1.211.1.31.1.1.1.2 | |||
| INT localServerUnitId | 1.3.6.1.4.1.211.1.31.1.1.1.2.1 | INTEGER | read-only | Unit identifier number of the local server (usually is ID 1). This ID can be used as index into the units table. |
| INT psPowerSupplyLoad | 1.3.6.1.4.1.211.1.31.1.1.1.2.1.6 | INTEGER | read-only | Actual power supply output load in Watts (0 = not available); Not supported. |
| INT numberUnits | 1.3.6.1.4.1.211.1.31.1.1.1.2.2 | INTEGER | read-only | Number of available units (size of units table). |
| unitTable | 1.3.6.1.4.1.211.1.31.1.1.1.2.3 | not-accessible | Description of all units in this MIB | |
| units | 1.3.6.1.4.1.211.1.31.1.1.1.2.3.1 | not-accessible | ||
| INT uUnitId | 1.3.6.1.4.1.211.1.31.1.1.1.2.3.1.1 | INTEGER | read-only | Unit identifier (index: 1..n) |
| INT unitClass | 1.3.6.1.4.1.211.1.31.1.1.1.2.3.1.2 | INTEGER | read-only | Unit classification (type) |
| INT unitCainetNr | 1.3.6.1.4.1.211.1.31.1.1.1.2.3.1.3 | INTEGER | read-only | Physical identification number or partition identification number of units. The ID of the 'chassis' is usually 0. |
| STR unitDesignation | 1.3.6.1.4.1.211.1.31.1.1.1.2.3.1.4 | DisplayString | read-only | Unit identification name. (e.g. 'SB#1') This object returns 'Part Number'; if the index shows chassis. |
| STR unitModelName | 1.3.6.1.4.1.211.1.31.1.1.1.2.3.1.5 | DisplayString | read-only | Unit model name (e.g. 'PRIMERGY PRIMEQUEST 3200 model xxx') |
| STR unitManufacturer | 1.3.6.1.4.1.211.1.31.1.1.1.2.3.1.6 | DisplayString | read-only | Unit manufacturer name (e.g. 'Fujitsu') |
| STR unitSerialNumber | 1.3.6.1.4.1.211.1.31.1.1.1.2.3.1.7 | DisplayString | read-only | Unit serial number (e.g. '0202456123') |
| STR unitLocation | 1.3.6.1.4.1.211.1.31.1.1.1.2.3.1.8 | DisplayString | read-only | Unit location string (e.g. 'ServerCenter Room 17; Rack 9') |
| STR unitContact | 1.3.6.1.4.1.211.1.31.1.1.1.2.3.1.9 | DisplayString | read-only | Unit contact name (e.g. 'Mr. Bond') |
| STR unitAdminURL | 1.3.6.1.4.1.211.1.31.1.1.1.2.3.1.10 | DisplayString | read-only | URL of administration HTML interface(MMB-GUI) (e.g. 'http://MyServer/admin') |
| INT frontDoorStatus | 1.3.6.1.4.1.211.1.31.1.1.1.2.3.1.11 | INTEGER | read-only | Status describing whether the front door is open or closed; Not supported. |
| INT housingOpenStatus | 1.3.6.1.4.1.211.1.31.1.1.1.2.3.1.12 | INTEGER | read-only | Status describing whether the housing is open or closed; Not supported. |
| STR msgLogLanguages | 1.3.6.1.4.1.211.1.31.1.1.1.2.3.1.13 | DisplayString | read-only | Supported languages of text message log (comma-seperated list of decimal language codes; see sc2MessageTextLogTable). e.g. '1031;1033' means German and English are supported. English (1033) is the default language and is always available; Not supported. |
| STR unitWorldWideName | 1.3.6.1.4.1.211.1.31.1.1.1.2.3.1.14 | DisplayString | read-only | Unit World Wide Name. A 64-bit sized address for storage devices (e.g. '6661E2B0A00B88FB'); Not supported. |
| STR remcsId | 1.3.6.1.4.1.211.1.31.1.1.1.2.3.1.15 | DisplayString | read-only | REMCS system identification string (binary data); Not supported. Format of Fujitsu REMCS ID (40byte) Format = TTMMMMMMMMMMMMmmmmmmmmmmmmCCnnnnnnnnnnnn TT : 2byte : Type ID for Company Name MM...M : 12byte : Model Name mm...m : 12byte : Device Name CC : 2byte : Checksum nn...n : 12byte : Serial number |
| STR assetTag | 1.3.6.1.4.1.211.1.31.1.1.1.2.3.1.16 | DisplayString | read-only | Customer specific asset tag (40 bytes) |
| STR unitManagementIpAddress | 1.3.6.1.4.1.211.1.31.1.1.1.2.3.1.18 | DisplayString | read-only | IPv4 address of the partition for management purpose (e.g. '192.168.0.140') |
| STR unitManagementIpAddressV6 | 1.3.6.1.4.1.211.1.31.1.1.1.2.3.1.20 | DisplayString | read-only | IPv6 address of the partition for management purpose (e.g. '2001:0db8:0000:85a3:0000:0000:ac1f:8001') |
| INT unitTableUpdateCount | 1.3.6.1.4.1.211.1.31.1.1.1.2.4 | INTEGER | read-only | Counter defining the update revision of the unit table. This counter is incremented with every table contents change/update. |
| unitParentTable | 1.3.6.1.4.1.211.1.31.1.1.1.2.5 | not-accessible | Parent-child relationship of all units | |
| unitParents | 1.3.6.1.4.1.211.1.31.1.1.1.2.5.1 | not-accessible | ||
| INT pUnitId | 1.3.6.1.4.1.211.1.31.1.1.1.2.5.1.1 | INTEGER | read-only | Unit identifier (index: 1..n) |
| INT pParentNr | 1.3.6.1.4.1.211.1.31.1.1.1.2.5.1.2 | INTEGER | read-only | Parent number (index: 1..n) |
| INT parentUnit | 1.3.6.1.4.1.211.1.31.1.1.1.2.5.1.3 | INTEGER | read-only | Parent unit. This is the same value as in the object of 'pParentNr'. |
| INT parentUnitClass | 1.3.6.1.4.1.211.1.31.1.1.1.2.5.1.4 | INTEGER | read-only | Unit classification (type). This is the same value as in units table. |
| unitChildTable | 1.3.6.1.4.1.211.1.31.1.1.1.2.6 | not-accessible | Parent-child relationship of all units | |
| unitChilds | 1.3.6.1.4.1.211.1.31.1.1.1.2.6.1 | not-accessible | ||
| INT cUnitId | 1.3.6.1.4.1.211.1.31.1.1.1.2.6.1.1 | INTEGER | read-only | Unit identifier (index: 1..n) |
| INT cChildNr | 1.3.6.1.4.1.211.1.31.1.1.1.2.6.1.2 | INTEGER | read-only | Child number (index: 1..n) |
| INT childUnit | 1.3.6.1.4.1.211.1.31.1.1.1.2.6.1.3 | INTEGER | read-only | Child unit. This is the same value as in the object of 'cChildNr'. |
| INT childUnitClass | 1.3.6.1.4.1.211.1.31.1.1.1.2.6.1.4 | INTEGER | read-only | Unit classification (type). This is the same value as in units table. |
| INT parentChildTableUpdateCount | 1.3.6.1.4.1.211.1.31.1.1.1.2.7 | INTEGER | read-only | Counter defining the update revision of the parent-child unit table. This counter is incremented with every table contents change/update. |
| management | 1.3.6.1.4.1.211.1.31.1.1.1.3 | |||
| managementNodeTable | 1.3.6.1.4.1.211.1.31.1.1.1.3.1 | not-accessible | SNMP management node addresses (how to address the units) | |
| managementNodes | 1.3.6.1.4.1.211.1.31.1.1.1.3.1.1 | not-accessible | ||
| INT mnUnitId | 1.3.6.1.4.1.211.1.31.1.1.1.3.1.1.1 | INTEGER | read-only | Unit identifier (index: 1..n) |
| INT mnNodeNr | 1.3.6.1.4.1.211.1.31.1.1.1.3.1.1.2 | INTEGER | read-only | Management node address number (index: 1..n) |
| INT unitNodeIfType | 1.3.6.1.4.1.211.1.31.1.1.1.3.1.1.3 | INTEGER | read-only | Management node interface type |
| STR unitNodeAddress | 1.3.6.1.4.1.211.1.31.1.1.1.3.1.1.4 | DisplayString | read-only | Management node address (e.g. 192.168.0.100) |
| STR unitNodeIpNetmask | 1.3.6.1.4.1.211.1.31.1.1.1.3.1.1.5 | DisplayString | read-only | Management node address (e.g. 255.255.255.128) |
| STR unitNodeGateway | 1.3.6.1.4.1.211.1.31.1.1.1.3.1.1.6 | DisplayString | read-only | Management node address (e.g. 192.168.0.126) |
| STR unitNodeName | 1.3.6.1.4.1.211.1.31.1.1.1.3.1.1.7 | DisplayString | read-only | Management node name (e.g. 'primequest-no1') |
| INT unitNodeClass | 1.3.6.1.4.1.211.1.31.1.1.1.3.1.1.8 | INTEGER | read-only | Management node class: primary: operating system interface secondary: remote management controller interface management-blade: management blade in blade server secondary-backup: backup remote management controller interface |
| PHY unitNodeMacAddress | 1.3.6.1.4.1.211.1.31.1.1.1.3.1.1.9 | PhysAddress | read-only | Management node hardware (MAC) address; ff:ff:ff:ff:ff:ff if value not available |
| INT unitNodeUseDHCP | 1.3.6.1.4.1.211.1.31.1.1.1.3.1.1.10 | INTEGER | read-only | Management node uses DHCP to obtain its address |
| STR unitNodeControllerType | 1.3.6.1.4.1.211.1.31.1.1.1.3.1.1.11 | DisplayString | read-only | The type of the remote management controller (for identification); like 'RSB'; 'RSB S2'; 'RSB S2 LP'... These names will not be changed if defined once; Not supported. |
| STR unitNodeControllerModel | 1.3.6.1.4.1.211.1.31.1.1.1.3.1.1.12 | DisplayString | read-only | The model name of the remote management controller (for displaying); like 'Remote Service Board'; RemoteView Service Board S2'c This name should not be used for identification;only for displaying (can be changed in different firmware versions)! Not supported. |
| STR unitNodeControllerFWVersion | 1.3.6.1.4.1.211.1.31.1.1.1.3.1.1.13 | DisplayString | read-only | The FW version of the remote management controller; Not supported. |
| INT nodeTableUpdateCount | 1.3.6.1.4.1.211.1.31.1.1.1.3.2 | INTEGER | read-only | Counter defining the update revision of the management node table. This counter is incremented with every table contents change/update. |
| INT managementChannelType | 1.3.6.1.4.1.211.1.31.1.1.1.3.3 | INTEGER | read-only | The type of the management channel currently used (this MIB instance). |
| managementProcessorTable | 1.3.6.1.4.1.211.1.31.1.1.1.3.4 | not-accessible | System management service processors | |
| managementProcessors | 1.3.6.1.4.1.211.1.31.1.1.1.3.4.1 | not-accessible | ||
| INT spUnitId | 1.3.6.1.4.1.211.1.31.1.1.1.3.4.1.1 | INTEGER | read-only | Unit identifier (index: 1..n) |
| INT spProcessorNr | 1.3.6.1.4.1.211.1.31.1.1.1.3.4.1.2 | INTEGER | read-only | Service processor number (index: 1..n) |
| STR spModelName | 1.3.6.1.4.1.211.1.31.1.1.1.3.4.1.3 | DisplayString | read-only | Service processor model name |
| STR spFirmwareVersion | 1.3.6.1.4.1.211.1.31.1.1.1.3.4.1.4 | DisplayString | read-only | Service processor firmware version / revision |
| INT spBatteryStatus | 1.3.6.1.4.1.211.1.31.1.1.1.3.4.1.5 | INTEGER | read-only | Service processor backup battery status |
| INT spBatteryDischargeTime | 1.3.6.1.4.1.211.1.31.1.1.1.3.4.1.6 | INTEGER | read-only | Maximum time (in seconds) this backup battery can discharged. after that a shutdown will be performed (-1 = unknown); Not supported. |
| CTR spTimeOnBattery | 1.3.6.1.4.1.211.1.31.1.1.1.3.4.1.7 | Counter | read-only | Time (in seconds) the service processor is running on battery since power fail (will be cleared on power recovery); Not supported. |
| INT spDoBatteryChargeCycle | 1.3.6.1.4.1.211.1.31.1.1.1.3.4.1.8 | INTEGER | read-write | Perform a discharge/charge cycle on the backup battery by writing a non-zero value. Reading this object just returns the value 0; Not supported. |
| GAU spBatteryChargeLevel | 1.3.6.1.4.1.211.1.31.1.1.1.3.4.1.9 | Gauge | read-only | Reads the current charge level of the rechargeable battery (in percent of the maximum capacity); Not supported. |
| managedUpsNodeTable | 1.3.6.1.4.1.211.1.31.1.1.1.3.5 | not-accessible | UPS nodes managed by the units; Not supported. | |
| managedUpsNodes | 1.3.6.1.4.1.211.1.31.1.1.1.3.5.1 | not-accessible | ||
| INT upsUnitId | 1.3.6.1.4.1.211.1.31.1.1.1.3.5.1.1 | INTEGER | read-only | Unit identifier (index: 1..n); Not supported. |
| INT upsNr | 1.3.6.1.4.1.211.1.31.1.1.1.3.5.1.2 | INTEGER | read-only | UPS number (index: 1..n); Not supported. |
| STR upsVendorName | 1.3.6.1.4.1.211.1.31.1.1.1.3.5.1.3 | DisplayString | read-only | UPS vendor name; Not supported. |
| STR upsModelName | 1.3.6.1.4.1.211.1.31.1.1.1.3.5.1.4 | DisplayString | read-only | UPS model name; Not supported. |
| STR upsIpAddress | 1.3.6.1.4.1.211.1.31.1.1.1.3.5.1.5 | DisplayString | read-only | UPS IP address (represented as string; may also contain an IP V6 address); Not supported. |
| STR upsMibRoot | 1.3.6.1.4.1.211.1.31.1.1.1.3.5.1.6 | DisplayString | read-only | UPS MIB root OID; specifies the root OID of the MIB to be used to query UPS via SNMP (empty string if no SNMP agent available); Not supported. |
| STR upsSnmpCommunity | 1.3.6.1.4.1.211.1.31.1.1.1.3.5.1.7 | DisplayString | read-only | UPS SNMP community name (empty string if no SNMP agent available); Not supported. |
| INT upsHttpPort | 1.3.6.1.4.1.211.1.31.1.1.1.3.5.1.8 | INTEGER | read-only | UPS HTTP interface port; specifies the TCP port number for accessing the UPS management interface via HTTP (0 if no HTTP server available); Not supported. |
| STR managementTimeZone | 1.3.6.1.4.1.211.1.31.1.1.1.3.6 | DisplayString | read-only | Management node timezone (e.g. '2004-9-22 12:15:18+09:00') |
| serverInformation | 1.3.6.1.4.1.211.1.31.1.1.1.4 | |||
| serverTable | 1.3.6.1.4.1.211.1.31.1.1.1.4.1 | not-accessible | Table containing information about the available servers | |
| servers | 1.3.6.1.4.1.211.1.31.1.1.1.4.1.1 | not-accessible | ||
| INT srvUnitId | 1.3.6.1.4.1.211.1.31.1.1.1.4.1.1.1 | INTEGER | read-only | Unit identifier (index: 1..n) |
| INT srvPhysicalMemory | 1.3.6.1.4.1.211.1.31.1.1.1.4.1.1.2 | INTEGER | read-only | Size of physical main memory installed (MBytes); Not supported. |
| INT srvLastBootResult | 1.3.6.1.4.1.211.1.31.1.1.1.4.1.1.3 | INTEGER | read-only | Result of last system boot; Not supported. |
| INT srvCurrentBootStatus | 1.3.6.1.4.1.211.1.31.1.1.1.4.1.1.4 | INTEGER | read-only | Status of the current boot unknown(1)' returns; during the Power-on->POST and the shutdown->Power-off. |
| INT srvShutdownCommand | 1.3.6.1.4.1.211.1.31.1.1.1.4.1.1.5 | INTEGER | read-write | Shutdown the server and switch off or reset; a delay (see object below) can be defined before the command is being executed; on reading that value you get the currently pending or executing command value; argument tells what kind of action: power-on: switch power on power-off: switch power off power-cycle: switch power off and switch power on again. shutdown-and-off: execute a shutdown then power off shutdown-and-reset: execute a shutdown then reset shutdown-and-power-cycle: execute a shutdown then power off and on again raise-nmi: raise an NMI (normally causes debugger to start) The value unknown(1) cannot be set; Not supported. |
| INT srvShutdownDelay | 1.3.6.1.4.1.211.1.31.1.1.1.4.1.1.6 | INTEGER | read-write | Delay time (seconds) the agent waits before executing the shutdown command (see previous command). 0 = immediate action; no delay -1 = unknown (delay not supported) The value unknown(-1) cannot be set; Not supported. |
| STR srvUUID | 1.3.6.1.4.1.211.1.31.1.1.1.4.1.1.7 | DisplayString | read-only | Universal Unique ID (UUID) number - this is a world wide unique ID number of the server. Can be used for identifying a server. The format is like this: 157E465A-A4AC-D711-A847-DD85CECD12EC. |
| INT srvPhysicalMemoryOs | 1.3.6.1.4.1.211.1.31.1.1.1.4.1.1.8 | INTEGER | read-only | Size of physical main memory available to the operating system (MBytes). This value is similar to sc2srvPhysicalMemory'; but may be less if the system has mirror or hot spare memory modules; Not supported. |
| INT srvTpmMode | 1.3.6.1.4.1.211.1.31.1.1.1.4.1.1.9 | INTEGER | read-only | Trusted Platform Module(TPM) setting. |
| STR srvManagementIP | 1.3.6.1.4.1.211.1.31.1.1.1.4.1.1.10 | DisplayString | read-only | BMC management address (e.g. 192.168.0.150) |
| unitPowerOnOffTable | 1.3.6.1.4.1.211.1.31.1.1.1.4.2 | not-accessible | Unit power-on and -off information | |
| unitPowerOnOff | 1.3.6.1.4.1.211.1.31.1.1.1.4.2.1 | not-accessible | ||
| INT ooUnitId | 1.3.6.1.4.1.211.1.31.1.1.1.4.2.1.1 | INTEGER | read-only | Unit identifier (index: 1..n) |
| INT powerOnOffStatus | 1.3.6.1.4.1.211.1.31.1.1.1.4.2.1.2 | INTEGER | read-only | Current power on/off status |
| INT lastPowerOffSource | 1.3.6.1.4.1.211.1.31.1.1.1.4.2.1.3 | INTEGER | read-only | Reason why the system was switched off last time; Not supported. |
| INT lastPowerOnSource | 1.3.6.1.4.1.211.1.31.1.1.1.4.2.1.4 | INTEGER | read-only | Source the system was switched on from; Not supported. |
| INT lastPowerOnTime | 1.3.6.1.4.1.211.1.31.1.1.1.4.2.1.5 | INTEGER | read-only | Time and Date the system was booted (seconds since 1/1/1970; -1 = unknown); Not supported. |
| INT powerOnCounts | 1.3.6.1.4.1.211.1.31.1.1.1.4.2.1.6 | INTEGER | read-only | Tells how often the server was switched on in its life (-1 = unknown); Not supported. |
| INT powerOnDuration | 1.3.6.1.4.1.211.1.31.1.1.1.4.2.1.7 | INTEGER | read-only | Tells how long the system has stayed ON in its life (in hours; -1 = unknown); Not supported. |
| INT powerOffDuration | 1.3.6.1.4.1.211.1.31.1.1.1.4.2.1.8 | INTEGER | read-only | Tells how long the system has stayed OFF in its life (in hours; -1 = unknown); Not supported. |
| INT powerFailRecovery | 1.3.6.1.4.1.211.1.31.1.1.1.4.2.1.9 | INTEGER | read-only | Action on AC power recovery after AC has failed. not-available(2) : function not available; behavior is hardware-defined. as-before(3) : server gets the same power state as before the AC fail. remain-off(4) : server remains off on power resume. switch-on(5) : server is always switched on on power resume. schedule-sync(6) : server synchronizes the power state with the schedule setting. |
| INT powerCommand | 1.3.6.1.4.1.211.1.31.1.1.1.4.2.1.10 | INTEGER | read-write | Switch the unit on or off; argument tells what kind of action: on: switch power on off: switch power off power-cycle: switch power off and switch power on again. The value unknown(1) cannot be set; Not supported. |
| INT powerSupplyRedundancy | 1.3.6.1.4.1.211.1.31.1.1.1.4.2.1.11 | INTEGER | read-only | Specifies whether the power supply system contains redundant power supplies: 0 : no redundant power supplies available 1 : redundant power supplies available |
| performanceTable | 1.3.6.1.4.1.211.1.31.1.1.1.4.3 | not-accessible | Server performance and utilization information; Not supported. | |
| performance | 1.3.6.1.4.1.211.1.31.1.1.1.4.3.1 | not-accessible | ||
| INT perfUnitId | 1.3.6.1.4.1.211.1.31.1.1.1.4.3.1.1 | INTEGER | read-only | Unit identifier (index; 1..n); Not supported. |
| INT perfNr | 1.3.6.1.4.1.211.1.31.1.1.1.4.3.1.2 | INTEGER | read-only | Server performance entry number (index; 1..n) |
| INT perfType | 1.3.6.1.4.1.211.1.31.1.1.1.4.3.1.3 | INTEGER | read-only | Server performance object type (description see below); Not supported. |
| GAU performanceValue | 1.3.6.1.4.1.211.1.31.1.1.1.4.3.1.4 | Gauge | read-only | Server performance value (value interpretation depending on type):; Not supported. cpu: Load of a single CPU in percent cpu-overall: Overall CPU load in percent pci-load: PCI bus load in percent pci-efficiency: PCI bus efficiency in percent (100% is optimum) pci-transfer: PCI bus transfer rate in MBytes/sec. memory-physical: Physical memory usage in MBytes memory-total: Total memory usage (physical + virtual) in MBytes memory-percent: Physical memory usage in percent |
| STR performanceName | 1.3.6.1.4.1.211.1.31.1.1.1.4.3.1.5 | DisplayString | read-only | Name (short description) of the performance value (e.g. 'CPU1'). Can be used for displaying a list of performance values in the management frontend; Not supported. |
| timerOnOffTable | 1.3.6.1.4.1.211.1.31.1.1.1.4.4 | not-accessible | Power on/off timer table; Not supported. | |
| timerOnOff | 1.3.6.1.4.1.211.1.31.1.1.1.4.4.1 | not-accessible | ||
| INT tooUnitId | 1.3.6.1.4.1.211.1.31.1.1.1.4.4.1.1 | INTEGER | read-only | Unit identifier (index: 1..n); Not supported. |
| INT tooDayOfWeek | 1.3.6.1.4.1.211.1.31.1.1.1.4.4.1.2 | INTEGER | read-only | Day of the week the times should act upon (index); 1=Sunday 2=Monday... ; Not supported. |
| INT onTime | 1.3.6.1.4.1.211.1.31.1.1.1.4.4.1.3 | INTEGER | read-write | Time the system should be switched on (by the real-time clock; in minutes since midnight; -1 = disabled; no on time). Only values -1 and 0..1439 are allowed; Not supported. |
| INT offTime | 1.3.6.1.4.1.211.1.31.1.1.1.4.4.1.4 | INTEGER | read-write | Time the system should be switched off (by the real-time clock of software; in minutes since midnight; -1 = disabled; no on time). Only values -1 and 0..1439 are allowed; Not supported. |
| powerMonitoringTable | 1.3.6.1.4.1.211.1.31.1.1.1.4.5 | not-accessible | Power monitoring table | |
| powerMonitoring | 1.3.6.1.4.1.211.1.31.1.1.1.4.5.1 | not-accessible | ||
| INT pmUnitId | 1.3.6.1.4.1.211.1.31.1.1.1.4.5.1.1 | INTEGER | read-only | Unit identifier (index: 1..n) |
| TRU pmCurrentPowerMonitoringAvailable | 1.3.6.1.4.1.211.1.31.1.1.1.4.5.1.2 | TrueFalse | read-only | Power monitoring and control available on this server: true: Power monitoring and power control is available false: Power monitoring and power control is not available |
| TRU pmCurrentPowerMonitoringEnabled | 1.3.6.1.4.1.211.1.31.1.1.1.4.5.1.3 | TrueFalse | read-only | Power monitoring enable value: true: Power monitoring and data gathering is enabled false: Power monitoring and data gathering is disabled or not available |
| INT pmNominalPowerConsumption | 1.3.6.1.4.1.211.1.31.1.1.1.4.5.1.4 | INTEGER | read-only | Nominal (maximum) value of the system's power consumption (in Watts; -1 if value not available) |
| GAU pmCurrentPowerConsumption | 1.3.6.1.4.1.211.1.31.1.1.1.4.5.1.5 | Gauge | read-only | Current value of the system's power consumption (in Watts; 4294967295(0xffffffff) if value not available) |
| INT pmCurrentPowerControl | 1.3.6.1.4.1.211.1.31.1.1.1.4.5.1.6 | INTEGER | read-only | Power mode control value; Not supported. disabled: The baseboard management controller does not control the power saving behaviour best-performance: The baseboard management controller gives best performance to the system (power consumption may be increased) minimum-power: The baseboard management controller controls the system in way to consume minimum power (performance may be reduced) automatic: The baseboard management controller automatically controls power consumption between good performance and low power consumption scheduled: The baseboard management controller controls power consumption by schedule |
| INT pmPowerLimitThreshold | 1.3.6.1.4.1.211.1.31.1.1.1.4.5.1.8 | INTEGER | read-only | Maximum limit value of the system's power consumption (in Watts; -1 if value not available; only valid if limiting enabled) |
| INT pmPowerControlMode | 1.3.6.1.4.1.211.1.31.1.1.1.4.5.1.11 | INTEGER | read-only | Configured power control mode value: disabled: The management controller does not control the power saving behaviour best-performance: The management controller gives best performance to the system (power consumption may be increased) minimum-power: The management controller controls the system in way to consume minimum power (performance may be reduced) automatic: The management controller automatically controls power consumption between good performance and low power consumption scheduled: The management controller controls power consumption by schedule limited: The management controller controls power consumption by power limit low-noise: The management controller controls the power to ensure running |
| INT pmPowerDisplayUnit | 1.3.6.1.4.1.211.1.31.1.1.1.4.5.1.12 | INTEGER | read-only | Configurd unit for the display of power consumption values: Watt: Power consumption values are displayed in Watts Btu/h: Power consumption values are displyed in Btu |
| utilizationHistoryTable | 1.3.6.1.4.1.211.1.31.1.1.1.4.6 | not-accessible | Utilization history table (for power consumption); table only contains existing values (no values for non-existing values); Not supported. | |
| utilizationHistory | 1.3.6.1.4.1.211.1.31.1.1.1.4.6.1 | not-accessible | ||
| INT uthUnitId | 1.3.6.1.4.1.211.1.31.1.1.1.4.6.1.1 | INTEGER | read-only | Unit identifier (index; 1..n); Not supported. |
| INT uthEntity | 1.3.6.1.4.1.211.1.31.1.1.1.4.6.1.2 | INTEGER | read-only | Utilization value entity; describes what kind of value to be requested; Not supported. powerConsumptionDay: power consumption values of the last 24 hours; one value (Watts) per minute powerConsumptionMonth: power consumption values of the last month; one value (Watts) per hour powerConsumptionYear: power consumption values of the last year; one value (Watts) per day |
| INT uthTimeStamp | 1.3.6.1.4.1.211.1.31.1.1.1.4.6.1.3 | INTEGER | read-only | Time stamp of the currenty history entry (time_t = seconds since 1/1/1970; 0:00 AM); Not supported. |
| STR uthHardwareUUID | 1.3.6.1.4.1.211.1.31.1.1.1.4.6.1.4 | DisplayString | read-only | UUID of the hardware instance that delivered the value (from object sc2srvUUID); may change if an installation is migrated to another hardware (e.g. in blade environments); Not supported. |
| GAU uthAverageValue | 1.3.6.1.4.1.211.1.31.1.1.1.4.6.1.5 | Gauge | read-only | Average value (in Watts) within the monitored time period (minute; hour; day); Not supported. |
| GAU uthMinValue | 1.3.6.1.4.1.211.1.31.1.1.1.4.6.1.6 | Gauge | read-only | Minimum (lowest) value within the monitored time period; Not supported. |
| GAU uthMaxValue | 1.3.6.1.4.1.211.1.31.1.1.1.4.6.1.7 | Gauge | read-only | Maximum (highest) value within the monitored time period; Not supported. |
| powerSourceInformationTable | 1.3.6.1.4.1.211.1.31.1.1.1.4.7 | not-accessible | Power source information table | |
| powerSourceInformation | 1.3.6.1.4.1.211.1.31.1.1.1.4.7.1 | not-accessible | ||
| INT psiUnitId | 1.3.6.1.4.1.211.1.31.1.1.1.4.7.1.1 | INTEGER | read-only | Unit identifier (index; 1..n) |
| STR psiPowerSourceType | 1.3.6.1.4.1.211.1.31.1.1.1.4.7.1.2 | DisplayString | read-only | System input power source type (e.g. 'AC'; 'DC') |
| INT psiPowerSourcePhase | 1.3.6.1.4.1.211.1.31.1.1.1.4.7.1.3 | INTEGER | read-only | System input phase of power source. |
| INT psiPowerSourceVoltage | 1.3.6.1.4.1.211.1.31.1.1.1.4.7.1.4 | INTEGER | read-only | System nominal input voltage of power source (in Volts; -1 if value not available). |
| environment | 1.3.6.1.4.1.211.1.31.1.1.1.5 | |||
| temperatureSensorTable | 1.3.6.1.4.1.211.1.31.1.1.1.5.1 | not-accessible | Temperature sensors | |
| temperatureSensors | 1.3.6.1.4.1.211.1.31.1.1.1.5.1.1 | not-accessible | ||
| INT tempUnitId | 1.3.6.1.4.1.211.1.31.1.1.1.5.1.1.1 | INTEGER | read-only | Unit identifier (index: 1..n) |
| INT tempSensorNr | 1.3.6.1.4.1.211.1.31.1.1.1.5.1.1.2 | INTEGER | read-only | Temperature sensor number (index: 0..n) |
| STR tempSensorDesignation | 1.3.6.1.4.1.211.1.31.1.1.1.5.1.1.3 | DisplayString | read-only | Temperature sensor designation (e.g. SB#0-CPU#A0 Temp.) |
| STR tempSensorIdentifier | 1.3.6.1.4.1.211.1.31.1.1.1.5.1.1.4 | DisplayString | read-only | Temperature sensor identification string (e.g. TEMP-RSB1); Not supported. |
| INT tempSensorStatus | 1.3.6.1.4.1.211.1.31.1.1.1.5.1.1.5 | INTEGER | read-only | Status of the temperature sensor Status mapping. SEL level MIB Value Warning temperature-warning(6) Error temperature-critical(7) Error failed(5) |
| INT tempCurrentTemperature | 1.3.6.1.4.1.211.1.31.1.1.1.5.1.1.6 | INTEGER | read-only | Current temperature at this sensor (degrees Celsius). This object returns 0; if the agent can not get the value. |
| INT tempWarningLevel | 1.3.6.1.4.1.211.1.31.1.1.1.5.1.1.7 | INTEGER | read-only | Maximum temperature - warning level (degrees Celsius) |
| INT tempCriticalLevel | 1.3.6.1.4.1.211.1.31.1.1.1.5.1.1.8 | INTEGER | read-only | Maximum temperature - critical level (degrees Celsius). system shutdown may occur if this level is exceeded. |
| INT tempCriticalReaction | 1.3.6.1.4.1.211.1.31.1.1.1.5.1.1.9 | INTEGER | read-only | Reaction if temperature exceeds the critical level. |
| fanTable | 1.3.6.1.4.1.211.1.31.1.1.1.5.2 | not-accessible | Fans | |
| fans | 1.3.6.1.4.1.211.1.31.1.1.1.5.2.1 | not-accessible | ||
| INT fanUnitId | 1.3.6.1.4.1.211.1.31.1.1.1.5.2.1.1 | INTEGER | read-only | Unit identifier (index: 1..n) |
| INT fanNr | 1.3.6.1.4.1.211.1.31.1.1.1.5.2.1.2 | INTEGER | read-only | Fan number (index: 0..n) |
| STR fanDesignation | 1.3.6.1.4.1.211.1.31.1.1.1.5.2.1.3 | DisplayString | read-only | Fan designation (e.g. FAN-TRAY#00-Fan#00-1) |
| STR fanIdentifier | 1.3.6.1.4.1.211.1.31.1.1.1.5.2.1.4 | DisplayString | read-only | Fan identification string (e.g. FAN-1-POWERSUPPLY); Not supported. |
| INT fanStatus | 1.3.6.1.4.1.211.1.31.1.1.1.5.2.1.5 | INTEGER | read-only | Status of the fan Status mapping. SEL level MIB Value Error failed(5) |
| INT fanCurrentSpeed | 1.3.6.1.4.1.211.1.31.1.1.1.5.2.1.6 | INTEGER | read-only | Current fan speed (revolutions per minute). This object returns 0; if the agent can not get the value. |
| INT fanQuality | 1.3.6.1.4.1.211.1.31.1.1.1.5.2.1.7 | INTEGER | read-only | Quality of fan (in percent of nominal speed - measured at full speed); Not supported. |
| INT fanFailReaction | 1.3.6.1.4.1.211.1.31.1.1.1.5.2.1.8 | INTEGER | read-only | Reaction if the fan fails. |
| INT fanFailShutdownDelay | 1.3.6.1.4.1.211.1.31.1.1.1.5.2.1.9 | INTEGER | read-write | Delay time (in seconds) when shutdown should commit on fan fail (if shutdown-and-off is configured; 0 = immediately -1 = unknown; cannot be set); Not supported. |
| airflowTable | 1.3.6.1.4.1.211.1.31.1.1.1.5.3 | not-accessible | Exhaust airflow volume table | |
| airflow | 1.3.6.1.4.1.211.1.31.1.1.1.5.3.1 | not-accessible | ||
| INT afUnitId | 1.3.6.1.4.1.211.1.31.1.1.1.5.3.1.1 | INTEGER | read-only | Unit identifier (index; 1..n) |
| INT afExhaustAirflowVolume | 1.3.6.1.4.1.211.1.31.1.1.1.5.3.1.2 | INTEGER | read-only | System exhaust airflow volume ('-1' if value not available) |
| STR afExhaustAirflowVolumeUnit | 1.3.6.1.4.1.211.1.31.1.1.1.5.3.1.3 | DisplayString | read-only | System exhaust airflow volume unit (e.g. 'cbm/h'; 'ccm/min'; ...) |
| hardware | 1.3.6.1.4.1.211.1.31.1.1.1.6 | |||
| systemBoardTable | 1.3.6.1.4.1.211.1.31.1.1.1.6.1 | not-accessible | System board (main board) information | |
| systemBoard | 1.3.6.1.4.1.211.1.31.1.1.1.6.1.1 | not-accessible | ||
| INT sbUnitId | 1.3.6.1.4.1.211.1.31.1.1.1.6.1.1.1 | INTEGER | read-only | Unit identifier (index: 1..n) |
| STR systemBoardModelName | 1.3.6.1.4.1.211.1.31.1.1.1.6.1.1.2 | DisplayString | read-only | Model name (e.g. 'System Board') |
| STR systemBoardProductNumber | 1.3.6.1.4.1.211.1.31.1.1.1.6.1.1.3 | DisplayString | read-only | Product number (may be identical to ModelName) |
| STR systemBoardRevision | 1.3.6.1.4.1.211.1.31.1.1.1.6.1.1.4 | DisplayString | read-only | Revision string (e.g. 'WGS1 GS3') |
| STR systemBoardSerialNumber | 1.3.6.1.4.1.211.1.31.1.1.1.6.1.1.5 | DisplayString | read-only | Serial number (not available for all boards) |
| powerSupplyTable | 1.3.6.1.4.1.211.1.31.1.1.1.6.2 | not-accessible | Power supplies | |
| powerSupply | 1.3.6.1.4.1.211.1.31.1.1.1.6.2.1 | not-accessible | ||
| INT psUnitId | 1.3.6.1.4.1.211.1.31.1.1.1.6.2.1.1 | INTEGER | read-only | Unit identifier (index: 1..n) |
| INT psPowerSupplyNr | 1.3.6.1.4.1.211.1.31.1.1.1.6.2.1.2 | INTEGER | read-only | Power supply (bay) number (index: 0..n) |
| STR powerSupplyDesignation | 1.3.6.1.4.1.211.1.31.1.1.1.6.2.1.3 | DisplayString | read-only | Power supply designation (e.g. PWRSYS#1-FEP#0) |
| STR powerSupplyIdentifier | 1.3.6.1.4.1.211.1.31.1.1.1.6.2.1.4 | DisplayString | read-only | Power supply identification string (e.g. PS1); Not supported. |
| INT powerSupplyStatus | 1.3.6.1.4.1.211.1.31.1.1.1.6.2.1.5 | INTEGER | read-only | Power supply status Status mapping. SEL level MIB Value Warning ac-fail(5) Warning predictive-fail(9) Error failed(4) Error not-manageable(8) |
| voltageTable | 1.3.6.1.4.1.211.1.31.1.1.1.6.3 | not-accessible | Voltages - all voltage values are in 1/100th Volts; a value of 330 means 3.30 Volts (0xffffffff = unknown) | |
| voltages | 1.3.6.1.4.1.211.1.31.1.1.1.6.3.1 | not-accessible | ||
| INT voUnitId | 1.3.6.1.4.1.211.1.31.1.1.1.6.3.1.1 | INTEGER | read-only | Unit identifier (index: 1..n) |
| INT voSensorNr | 1.3.6.1.4.1.211.1.31.1.1.1.6.3.1.2 | INTEGER | read-only | Voltage sensor number (index: 0..n) |
| STR voltageDesignation | 1.3.6.1.4.1.211.1.31.1.1.1.6.3.1.3 | DisplayString | read-only | Voltage designation string (e.g. SB#1-+5V#1) |
| INT voltageStatus | 1.3.6.1.4.1.211.1.31.1.1.1.6.3.1.4 | INTEGER | read-only | Voltage status Status mapping. SEL level MIB Value Warning low-warning(7) Warning high-warning(8) Error too-low(4) Error too-high(5) |
| INT voltageCurrentValue | 1.3.6.1.4.1.211.1.31.1.1.1.6.3.1.5 | INTEGER | read-only | Voltage current value. This object returns 0; if the agent can not get the value.(1/100V) |
| INT voltageNominalValue | 1.3.6.1.4.1.211.1.31.1.1.1.6.3.1.6 | INTEGER | read-only | Voltage nominal value; Not supported. |
| INT voltageMinimumLevel | 1.3.6.1.4.1.211.1.31.1.1.1.6.3.1.7 | INTEGER | read-only | Voltage minimum level (1/100V) |
| INT voltageMaximumLevel | 1.3.6.1.4.1.211.1.31.1.1.1.6.3.1.8 | INTEGER | read-only | Voltage maximum level (1/100V) |
| GAU voltageCurrentLoad | 1.3.6.1.4.1.211.1.31.1.1.1.6.3.1.9 | Gauge | read-only | Current output load on this voltage line. in percent of the maximum load (0xffffffff = unknown); Not supported. |
| cpuTable | 1.3.6.1.4.1.211.1.31.1.1.1.6.4 | not-accessible | CPU description table | |
| cpus | 1.3.6.1.4.1.211.1.31.1.1.1.6.4.1 | not-accessible | ||
| INT cpuUnitId | 1.3.6.1.4.1.211.1.31.1.1.1.6.4.1.1 | INTEGER | read-only | Unit identifier (index: 1..n) |
| INT cpuNr | 1.3.6.1.4.1.211.1.31.1.1.1.6.4.1.2 | INTEGER | read-only | CPU (socket) number (index: 0..n) |
| STR cpuDesignation | 1.3.6.1.4.1.211.1.31.1.1.1.6.4.1.3 | DisplayString | read-only | CPU designation (e.g. SB#0-CPU#A0) |
| INT cpuStatus | 1.3.6.1.4.1.211.1.31.1.1.1.6.4.1.4 | INTEGER | read-only | CPU status Status mapping. SEL level MIB Value Warning disabled(4) Warning prefailed-warning(8) Error failed(6) |
| STR cpuModelName | 1.3.6.1.4.1.211.1.31.1.1.1.6.4.1.5 | DisplayString | read-only | CPU model name (e.g. Itanium2 Processor) |
| STR cpuManufacturer | 1.3.6.1.4.1.211.1.31.1.1.1.6.4.1.6 | DisplayString | read-only | CPU manufacturer name (e.g. Intel); Not supported. |
| STR cpuStep | 1.3.6.1.4.1.211.1.31.1.1.1.6.4.1.7 | DisplayString | read-only | CPU step / revision |
| INT cpuCurrentSpeed | 1.3.6.1.4.1.211.1.31.1.1.1.6.4.1.8 | INTEGER | read-only | CPU speed (frequency in MHz) |
| INT cpuNumberLogicals | 1.3.6.1.4.1.211.1.31.1.1.1.6.4.1.9 | INTEGER | read-only | Number of (physically available) logical CPUs within one physical CPU (for hyper-threading and multi-core CPUs). This is the sum of all cores and all logical CPUs of a hyper-threading CPU; Not supported. |
| INT cpuCacheL1Size | 1.3.6.1.4.1.211.1.31.1.1.1.6.4.1.10 | INTEGER | read-only | Size of first level cache (in kBytes; -1 if unknown); Not supported. |
| INT cpuCacheL2Size | 1.3.6.1.4.1.211.1.31.1.1.1.6.4.1.11 | INTEGER | read-only | Size of second level cache (in kBytes; -1 if unknown); Not supported. |
| INT cpuCacheL3Size | 1.3.6.1.4.1.211.1.31.1.1.1.6.4.1.12 | INTEGER | read-only | Size of third level cache (in kBytes; -1 if unknown) |
| INT cpuNumberCores | 1.3.6.1.4.1.211.1.31.1.1.1.6.4.1.13 | INTEGER | read-only | Number of (physically available) cores within one physical CPU (for multi-core CPUs; platform dependent) |
| INT cpuFamily | 1.3.6.1.4.1.211.1.31.1.1.1.6.4.1.14 | INTEGER | read-only | CPU family code. This enumerated value is specified by the DMTF SMBIOS specification (processor information; type 4); Not supported. |
| INT cpuEnabledCores | 1.3.6.1.4.1.211.1.31.1.1.1.6.4.1.15 | INTEGER | read-only | Number of effectively enabled cores within one physical CPU (for multi-core CPUs; 0 if unknown) |
| memoryModuleTable | 1.3.6.1.4.1.211.1.31.1.1.1.6.5 | not-accessible | Main memory module table | |
| memoryModules | 1.3.6.1.4.1.211.1.31.1.1.1.6.5.1 | not-accessible | ||
| INT memUnitId | 1.3.6.1.4.1.211.1.31.1.1.1.6.5.1.1 | INTEGER | read-only | Unit identifier (index: 1..n) |
| INT memModuleNr | 1.3.6.1.4.1.211.1.31.1.1.1.6.5.1.2 | INTEGER | read-only | Memory module (socket) number (index: 0..n) |
| STR memModuleDesignation | 1.3.6.1.4.1.211.1.31.1.1.1.6.5.1.3 | DisplayString | read-only | Memory module designation (e.g. SB#0-DIMM#0A0) |
| INT memModuleStatus | 1.3.6.1.4.1.211.1.31.1.1.1.6.5.1.4 | INTEGER | read-only | Memory module status Status mapping. SEL level MIB Value Warning failed-disabled(4) Warning warning(7) Error error(5) Error configuration-error(9) |
| INT memModuleBank | 1.3.6.1.4.1.211.1.31.1.1.1.6.5.1.5 | INTEGER | read-only | Memory module bank number (-1 if unknown); Not supported. |
| INT memModuleCapacity | 1.3.6.1.4.1.211.1.31.1.1.1.6.5.1.6 | INTEGER | read-only | Memory module size (capacity in MBytes; -1 if unknown) |
| INT memModuleStartAddress | 1.3.6.1.4.1.211.1.31.1.1.1.6.5.1.7 | INTEGER | read-only | Memory module start address (in MBytes; -1 if unknown); Not supported. |
| STR memModuleForm | 1.3.6.1.4.1.211.1.31.1.1.1.6.5.1.8 | DisplayString | read-only | Memory module form (SIMM DIMM ...); Not supported. |
| STR memModuleType | 1.3.6.1.4.1.211.1.31.1.1.1.6.5.1.9 | DisplayString | read-only | Memory module type (SDRAM DDRAM DDR2 DDR3 ...); Not supported. |
| CTR memModuleCorrErrors | 1.3.6.1.4.1.211.1.31.1.1.1.6.5.1.10 | Counter | read-only | Number of memory module correctable errors (-1 if unknown); Not supported. |
| CTR memModuleUncorrErrors | 1.3.6.1.4.1.211.1.31.1.1.1.6.5.1.11 | Counter | read-only | Number of memory module uncorrectable errors (-1 if unknown); Not supported. |
| INT memModuleApproved | 1.3.6.1.4.1.211.1.31.1.1.1.6.5.1.12 | INTEGER | read-only | Memory module approved for this machine; Not supported. |
| INT memModuleConfiguration | 1.3.6.1.4.1.211.1.31.1.1.1.6.5.1.13 | INTEGER | read-only | Memory module configuration; Not supported. unknown(1): Module configuration could not be evaluated normal(2): Module is in normal non-redundant configuration or slot is empty disabled(3): Module is disabled (manually through BIOS setup) hotSpare(4): Module is a hot-spare (standby) module; which will be used as a run-time-replacement for failed modules mirror(5): Module is part of a mirror configuration raid(6): Module is part of a RAID configuration notUsable(7): Module is not usable in the actual configuration because of architectural restrictions This object replaces the previous redundancy status values hot-spare and mirror in sc2memModuleStatus. |
| INT memModuleFrequency | 1.3.6.1.4.1.211.1.31.1.1.1.6.5.1.14 | INTEGER | read-only | Memory module actual front side bus frequency (in MHz; -1 if unknown). This value is based on the BIOS settings; Not supported. |
| INT memModuleMaxFrequency | 1.3.6.1.4.1.211.1.31.1.1.1.6.5.1.15 | INTEGER | read-only | Memory module maximum front side bus frequency (in MHz; -1 if unknown). This value is based on memory module SPD data; Not supported. |
| STR memModuleVoltInterface | 1.3.6.1.4.1.211.1.31.1.1.1.6.5.1.16 | DisplayString | read-only | Memory module interface voltage interface description; Not supported. |
| INT cpuMultithreadEnable | 1.3.6.1.4.1.211.1.31.1.1.1.6.6 | INTEGER | read-only | Multithreading of CPU enabled; Not supported. |
| componentPowerConsumptionTable | 1.3.6.1.4.1.211.1.31.1.1.1.6.7 | not-accessible | Table of component power consumption data; Not supported. | |
| componentPowerConsumption | 1.3.6.1.4.1.211.1.31.1.1.1.6.7.1 | not-accessible | ||
| INT cpcUnitId | 1.3.6.1.4.1.211.1.31.1.1.1.6.7.1.1 | INTEGER | read-only | Unit identifier (index; 1..n); Not supported. |
| INT cpcComponentClass | 1.3.6.1.4.1.211.1.31.1.1.1.6.7.1.2 | INTEGER | read-write | Component class enumeration (based on IPMI v1.0 entity ID); Not supported. |
| INT cpcComponentIndex | 1.3.6.1.4.1.211.1.31.1.1.1.6.7.1.3 | INTEGER | read-only | Component index within class (1..n); Not supported. |
| STR cpcDesignation | 1.3.6.1.4.1.211.1.31.1.1.1.6.7.1.4 | DisplayString | read-only | Component designation; Not supported. |
| INT cpcCurrentValue | 1.3.6.1.4.1.211.1.31.1.1.1.6.7.1.5 | INTEGER | read-only | Current component power consumption in Watts; Not supported. |
| trustedPlatformModuleTable | 1.3.6.1.4.1.211.1.31.1.1.1.6.8 | not-accessible | Trusted Platform Module (TPM) status information (see corresponding TPM specification for detailed description of these states) | |
| INT tpmUnitId | 1.3.6.1.4.1.211.1.31.1.1.1.6.8.1 | INTEGER | read-only | Unit identifier (index: 1..n) |
| trustedPlatformModule | 1.3.6.1.4.1.211.1.31.1.1.1.6.8.1 | not-accessible | ||
| TRU tpmHardwareAvailable | 1.3.6.1.4.1.211.1.31.1.1.1.6.8.2 | TrueFalseUnknown | read-only | TPM hardware is available ('unknown' if hardware availability cannot be detected; no interface found) |
| TRU tpmBiosEnabled | 1.3.6.1.4.1.211.1.31.1.1.1.6.8.3 | TrueFalseUnknown | read-only | TPM hardware is enabled by BIOS ('unknown' if hardware is not available; a reboot is required to change this value) |
| TRU tpmEnabled | 1.3.6.1.4.1.211.1.31.1.1.1.6.8.4 | TrueFalseUnknown | read-only | TPM is enabled (by software; cannot take ownership if disabled; 'unknown' if hardware is not available or disabled) |
| TRU tpmActivated | 1.3.6.1.4.1.211.1.31.1.1.1.6.8.5 | TrueFalseUnknown | read-only | TPM is activated (by software; 'unknown' if hardware is not available or disabled) |
| TRU tpmOwnership | 1.3.6.1.4.1.211.1.31.1.1.1.6.8.6 | TrueFalseUnknown | read-only | TPM ownership is established (valid endorsement key is existing; 'unknown' if hardware is not available or disabled) |
| recovery | 1.3.6.1.4.1.211.1.31.1.1.1.7 | |||
| messageLogTable | 1.3.6.1.4.1.211.1.31.1.1.1.7.1 | not-accessible | Error and event message handling; Not supported. | |
| messageLogs | 1.3.6.1.4.1.211.1.31.1.1.1.7.1.1 | not-accessible | ||
| INT msgUnitId | 1.3.6.1.4.1.211.1.31.1.1.1.7.1.1.1 | INTEGER | read-only | Unit identifier (index: 1..n); Not supported.. |
| INT msgLogEntryNr | 1.3.6.1.4.1.211.1.31.1.1.1.7.1.1.2 | INTEGER | read-only | Message log entry number (index: 0..n); Not supported.. |
| OCT msgLogEntryData | 1.3.6.1.4.1.211.1.31.1.1.1.7.1.1.3 | OCTET STRING | read-only | Message log entry data (binary; one message per table entry); Not supported.. |
| watchdogTable | 1.3.6.1.4.1.211.1.31.1.1.1.7.2 | not-accessible | Watchdogs | |
| watchdogs | 1.3.6.1.4.1.211.1.31.1.1.1.7.2.1 | not-accessible | ||
| INT wdUnitId | 1.3.6.1.4.1.211.1.31.1.1.1.7.2.1.1 | INTEGER | read-only | Unit identifier (index: 1..n) |
| INT watchdogType | 1.3.6.1.4.1.211.1.31.1.1.1.7.2.1.2 | INTEGER | read-only | Watchdog type |
| INT watchdogStatus | 1.3.6.1.4.1.211.1.31.1.1.1.7.2.1.3 | INTEGER | read-only | Watchdog status |
| INT watchdogEnable | 1.3.6.1.4.1.211.1.31.1.1.1.7.2.1.4 | INTEGER | read-only | Enable/disable watchdog |
| INT watchdogTime | 1.3.6.1.4.1.211.1.31.1.1.1.7.2.1.5 | INTEGER | read-only | Watchdog timeout period in seconds |
| INT watchdogAction | 1.3.6.1.4.1.211.1.31.1.1.1.7.2.1.6 | INTEGER | read-only | Watchdog timeout action |
| recoverySettingTable | 1.3.6.1.4.1.211.1.31.1.1.1.7.3 | not-accessible | ASR&R (Automatic server recovery and restart) settings; Not supported. | |
| recoverySettings | 1.3.6.1.4.1.211.1.31.1.1.1.7.3.1 | not-accessible | ||
| INT asrUnitId | 1.3.6.1.4.1.211.1.31.1.1.1.7.3.1.1 | INTEGER | read-only | Unit identifier (index: 1..n); Not supported. |
| INT asrNrRebootRetries | 1.3.6.1.4.1.211.1.31.1.1.1.7.3.1.2 | INTEGER | read-write | Current number of retries to reboot/restart the server when a failure shutdown (and power-off) had occurred. After this number of retries the action defined in 'sc2asrRebootFailAction' will be executed (-1 = unknown; no retries). The value unknown(1) cannot be set; a SET will deliver 'badValue'; Not supported. |
| INT asrDefaultRebootRetries | 1.3.6.1.4.1.211.1.31.1.1.1.7.3.1.3 | INTEGER | read-write | Default number of retries for server failure reboot. The previous object sc2asrNrRebootRetries will be set to this value after the server is working properly for a certain amount of time; Not supported. |
| INT asrNextBootSource | 1.3.6.1.4.1.211.1.31.1.1.1.7.3.1.4 | INTEGER | read-write | Source medium to boot from (next time): operating-system: boot from floppy or hard disk diag-system: boot from alternate diagnostic system (only for SCSI systems; load diagnostic system from alternate IDE disk). remote-disk: boot from remote network disk The value unknown(1) cannot be set; a SET will deliver 'badValue'; Not supported. |
| INT asrRebootFailAction | 1.3.6.1.4.1.211.1.31.1.1.1.7.3.1.5 | INTEGER | read-write | Specifies the action after a specified number of failed reboot retries (the object 'sc2asrNrRebootRetries' has reached zero).The value no-diag-system(4) means that a diagnostic system is not available; no other value can be set. The values unknown(1) and reserved(3) cannot be set; a SET will deliver 'badValue'; Not supported. |
| INT asrRestartDelay | 1.3.6.1.4.1.211.1.31.1.1.1.7.3.1.6 | INTEGER | read-write | Delay (in minutes) when the system should be automatically switched on again (by real-time clock) after an error power-off. Setting this value to zero means immediate restart (power-cycle only). You can disable automatic restart by setting the 'sc2asrRebootFailAction' to 'switch-off' and the 'sc2asrDefaultRebootRetries' to zero; Not supported. |
| INT asrPostErrorHalt | 1.3.6.1.4.1.211.1.31.1.1.1.7.3.1.7 | INTEGER | read-write | Describes what to do when a POST error has occurred (halt on any error; no halt on any error...). The values unknown(1) and other(9) cannot be set; a SET will deliver 'badValue'; Not supported. |
| messageTextLogTable | 1.3.6.1.4.1.211.1.31.1.1.1.7.4 | not-accessible | Error and event message handling; reported as text strings; Not supported. | |
| messageTextLogs | 1.3.6.1.4.1.211.1.31.1.1.1.7.4.1 | not-accessible | ||
| INT msgTextLogUnitId | 1.3.6.1.4.1.211.1.31.1.1.1.7.4.1.1 | INTEGER | read-only | Unit identifier (index: 1..n); Not supported. |
| INT msgTextLogLanguage | 1.3.6.1.4.1.211.1.31.1.1.1.7.4.1.2 | INTEGER | read-only | Message log entry language (index; Windows language code); Not supported. e.g. 1031; 1033 for German; English (default; always available) |
| INT msgTextLogSeqNr | 1.3.6.1.4.1.211.1.31.1.1.1.7.4.1.3 | INTEGER | read-only | Message log entry sequence number (index; 0..n); Not supported. |
| INT msgTextLogTimestamp | 1.3.6.1.4.1.211.1.31.1.1.1.7.4.1.4 | INTEGER | read-only | Message log entry time stamp (time_t = seconds since 1/1/1970; 0:00 AM); Not supported. |
| STR msgTextLogMessage | 1.3.6.1.4.1.211.1.31.1.1.1.7.4.1.5 | DisplayString | read-only | Message log entry message string (multi-byte string; multi-language; not every language may be implemented); Not supported. |
| INT msgTextLogErrorCode | 1.3.6.1.4.1.211.1.31.1.1.1.7.4.1.6 | INTEGER | read-only | Message log entry error code; Not supported. |
| INT msgTextLogSeverity | 1.3.6.1.4.1.211.1.31.1.1.1.7.4.1.7 | INTEGER | read-only | Message log entry severity; Not supported. |
| TRU msgTextLogCSSComponent | 1.3.6.1.4.1.211.1.31.1.1.1.7.4.1.8 | TrueFalse | read-only | Component which caused the log message may be replaced by the customer (CSS=Customer Self Service); Not supported. |
| messageLogActionHintTable | 1.3.6.1.4.1.211.1.31.1.1.1.7.5 | not-accessible | Action text strings for error and event messages; Not supported. | |
| messageLogActionHints | 1.3.6.1.4.1.211.1.31.1.1.1.7.5.1 | not-accessible | ||
| INT mlaLanguage | 1.3.6.1.4.1.211.1.31.1.1.1.7.5.1.1 | INTEGER | read-only | Action text language (index; Windows language code) e.g. 1031; 1033 for German; English; Not supported. |
| INT mlaErrorCode | 1.3.6.1.4.1.211.1.31.1.1.1.7.5.1.2 | INTEGER | read-only | Action text error code (index); Not supported. |
| INT mlaType | 1.3.6.1.4.1.211.1.31.1.1.1.7.5.1.3 | INTEGER | read-only | Message log entry severity; Not supported. |
| INT mlaIndex | 1.3.6.1.4.1.211.1.31.1.1.1.7.5.1.4 | INTEGER | read-only | Action text entry string index (index; 1..n); Not supported. |
| STR mlaMessage | 1.3.6.1.4.1.211.1.31.1.1.1.7.5.1.5 | DisplayString | read-only | Action message string; Not supported. |
| status | 1.3.6.1.4.1.211.1.31.1.1.1.8 | |||
| INT agentStatus | 1.3.6.1.4.1.211.1.31.1.1.1.8.1 | INTEGER | read-only | Overall status of all monitored components in this agent ok(1): all subsystems and components working properly; no failure degraded(2): at least one component has a problem; system may still work properly error(3): severe problem; system will not work properly failed(4): one or more managed components have failed unknown(5): none of the subsystems had a valid status (e.g. during initialization) |
| statusComponentTable | 1.3.6.1.4.1.211.1.31.1.1.1.8.2 | not-accessible | Table with status values of the components in this agent. The table summarizes all instances of one component to one status value. | |
| statusComponents | 1.3.6.1.4.1.211.1.31.1.1.1.8.2.1 | not-accessible | ||
| INT csUnitId | 1.3.6.1.4.1.211.1.31.1.1.1.8.2.1.1 | INTEGER | read-only | Unit identifier (index: 1..n) |
| INT csType | 1.3.6.1.4.1.211.1.31.1.1.1.8.2.1.2 | INTEGER | read-only | Component status type |
| INT componentStatusValue | 1.3.6.1.4.1.211.1.31.1.1.1.8.2.1.3 | INTEGER | read-only | Component status value (for description of status values see previous object) Status mapping. SEL level MIB Value Warning degraded(2) Warning failed(4) Error error(5) |
| componentStatusSensorTable | 1.3.6.1.4.1.211.1.31.1.1.1.8.3 | not-accessible | This table contains the component status sensor table of the BMC (baseboard management controller). Additionally it also holds the CSS (Customer Self Service) information; Not supported. | |
| componentStatusSensors | 1.3.6.1.4.1.211.1.31.1.1.1.8.3.1 | not-accessible | ||
| INT cssUnitId | 1.3.6.1.4.1.211.1.31.1.1.1.8.3.1.1 | INTEGER | read-only | Unit identifier (index: 1..n); Not supported. |
| INT cssSensorNumber | 1.3.6.1.4.1.211.1.31.1.1.1.8.3.1.2 | INTEGER | read-only | BMC component status sensor number (index; 1..n); Not supported. |
| STR cssSensorDesignation | 1.3.6.1.4.1.211.1.31.1.1.1.8.3.1.3 | DisplayString | read-only | Component status sensor designation string; Not supported. |
| STR cssSensorDevice | 1.3.6.1.4.1.211.1.31.1.1.1.8.3.1.4 | DisplayString | read-only | Name of device (entity) the component status sensor belongs to; Not supported. |
| INT cssSensorDeviceInstance | 1.3.6.1.4.1.211.1.31.1.1.1.8.3.1.5 | INTEGER | read-only | Instance number of device (entity) the component status sensor belongs to; Not supported. |
| TRU cssSensorPhysicalLed | 1.3.6.1.4.1.211.1.31.1.1.1.8.3.1.6 | TrueFalse | read-only | If set; component has a physical status LED showing the sensor status; Not supported. |
| TRU cssSensorCssComponent | 1.3.6.1.4.1.211.1.31.1.1.1.8.3.1.7 | TrueFalse | read-only | If set; component may be replaced by the customer (CSS component); Not supported. |
| INT cssSensorStatus | 1.3.6.1.4.1.211.1.31.1.1.1.8.3.1.8 | INTEGER | read-only | Status returned by the component status sensor; Not supported. |
| STR cssComponentServicePartId | 1.3.6.1.4.1.211.1.31.1.1.1.8.3.1.9 | DisplayString | read-only | Spare part number of the replaceable component; used to create a link to the spare part list on the service's spare part catalogue. This usually is the component's designation string; with blanks substituted by underscores; Not supported. |
| INT cssTableSize | 1.3.6.1.4.1.211.1.31.1.1.1.8.4 | INTEGER | read-only | Number of entries in the component status sensor table; Not supported. |
| maintenance | 1.3.6.1.4.1.211.1.31.1.1.1.9 | |||
| maintenanceObjectTable | 1.3.6.1.4.1.211.1.31.1.1.1.9.1 | not-accessible | Table containing some other maintenance objects. | |
| maintenanceObjects | 1.3.6.1.4.1.211.1.31.1.1.1.9.1.1 | not-accessible | ||
| INT mtUnitId | 1.3.6.1.4.1.211.1.31.1.1.1.9.1.1.1 | INTEGER | read-only | Unit identifier (index: 1..n). |
| INT errorCounterStartTime | 1.3.6.1.4.1.211.1.31.1.1.1.9.1.1.2 | INTEGER | read-only | Memory module error counter start time (seconds since 1/1/1970; -1 if unknown). This is the time when the error counters were started or reset last time; Not supported. |
| INT sendTestTrap | 1.3.6.1.4.1.211.1.31.1.1.1.9.1.1.3 | INTEGER | read-write | Send a test trap (test alarm) to the manager application(s) to test connection and trap configuration; trap cannot be disabled. Initiate test trap sending by writing a non-zero value. Reading this object just returns the value 0; Not supported. |
| IP addTrapDestination | 1.3.6.1.4.1.211.1.31.1.1.1.9.1.1.4 | IpAddress | read-write | Add the specified IP address (of the management station) to the trap destination list of this server. That client will become an alarm receiver for traps of this server; Not supported. |
| INT mtMaintenanceStatus | 1.3.6.1.4.1.211.1.31.1.1.1.9.1.1.5 | INTEGER | read-only | maitenance status |
| firmwareVersionTable | 1.3.6.1.4.1.211.1.31.1.1.1.9.2 | not-accessible | Controller firmware version table | |
| firmwareVersions | 1.3.6.1.4.1.211.1.31.1.1.1.9.2.1 | not-accessible | ||
| INT fwUnitId | 1.3.6.1.4.1.211.1.31.1.1.1.9.2.1.1 | INTEGER | read-only | Unit identifier (index: 1..n) |
| INT fwType | 1.3.6.1.4.1.211.1.31.1.1.1.9.2.1.2 | INTEGER | read-only | Controller/firmware type |
| STR fwModelName | 1.3.6.1.4.1.211.1.31.1.1.1.9.2.1.3 | DisplayString | read-only | Controller/firmware model name (e.g. 'Copernicus'...) TOTAL' shows all firmware version in system (including BIOS; BMC; MMB). |
| STR fwVersion | 1.3.6.1.4.1.211.1.31.1.1.1.9.2.1.4 | DisplayString | read-only | Controller/firmware version string (e.g. '3.81.02') |
| INT fwLocation | 1.3.6.1.4.1.211.1.31.1.1.1.9.2.1.5 | INTEGER | read-only | BMM physical number of controller/firmware on IOU. |
| deployment | 1.3.6.1.4.1.211.1.31.1.1.1.10 | |||
| deployInfoTable | 1.3.6.1.4.1.211.1.31.1.1.1.10.1 | not-accessible | Table with data of deployment information; Not supported. | |
| deployInfo | 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1 | not-accessible | ||
| INT dplInfoUnitId | 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.1 | INTEGER | read-only | Unit identifier (index: 1..n); Not supported. |
| STR deployInfoChassisId | 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.2 | DisplayString | read-only | Chassis serial number; Not supported. |
| PHY deployInfoMacAddr1 | 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.3 | PhysAddress | read-only | MAC address 1; Not supported. |
| PHY deployInfoMacAddr2 | 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.4 | PhysAddress | read-only | MAC address 2; Not supported. |
| PHY deployInfoMacAddr3 | 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.5 | PhysAddress | read-only | MAC address 3; Not supported. |
| PHY deployInfoMacAddr4 | 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.6 | PhysAddress | read-only | MAC address 4; Not supported. |
| IP deployInfoIpAddr1 | 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.7 | IpAddress | read-write | IP address 1; Not supported. |
| IP deployInfoIpAddr2 | 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.8 | IpAddress | read-write | IP address 2; Not supported. |
| IP deployInfoIpAddr3 | 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.9 | IpAddress | read-write | IP address 3; Not supported. |
| IP deployInfoIpAddr4 | 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.10 | IpAddress | read-write | IP address 4; Not supported. |
| IP deployInfoNetMask1 | 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.11 | IpAddress | read-write | IP subnet mask 1; Not supported. |
| IP deployInfoNetMask2 | 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.12 | IpAddress | read-write | IP subnet mask 2; Not supported. |
| IP deployInfoNetMask3 | 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.13 | IpAddress | read-write | IP subnet mask 3; Not supported. |
| IP deployInfoNetMask4 | 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.14 | IpAddress | read-write | IP subnet mask 4; Not supported. |
| IP deployInfoGateway1 | 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.15 | IpAddress | read-write | IP gateway 1; Not supported. |
| IP deployInfoGateway2 | 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.16 | IpAddress | read-write | IP gateway 2; Not supported. |
| IP deployInfoGateway3 | 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.17 | IpAddress | read-write | IP gateway 3; Not supported. |
| IP deployInfoGateway4 | 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.18 | IpAddress | read-write | IP gateway 4; Not supported. |
| STR deployInfoHostname | 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.19 | DisplayString | read-write | Host name; Not supported. |
| STR deployInfoMasterImageReference | 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.20 | DisplayString | read-write | URL in UNC notification (but in ASCII) to remote image file (with the extensions of *.img; *.cfg; *.txt); Not supported. |
| INT deployInfoStatusOfBlade | 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.21 | INTEGER | read-write | Status of this server: power-down(2): waiting for boot standby(3): power management mode system-boot-failure(4): system boot failure bios-setup(5): BIOS setup or boot phase booting(6): ACPI OS currently booting ; Not supported. |
| INT deployInfoLanStatusOfSlot | 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.22 | INTEGER | read-write | Defines whether the IP-LAN definitions are valid or not; Not supported. |
| INT deployInfoAutomaticRecovery | 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.23 | INTEGER | read-write | Defines if this server blade should be provided automatic recovery; Not supported. |
| INT deployInfoStatusOfCloning | 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.24 | INTEGER | read-write | Status of current cloning process; Not supported. |
| INT deployInfoBootMode | 1.3.6.1.4.1.211.1.31.1.1.1.10.1.1.25 | INTEGER | read-write | Boot mode of the server for remote deployment: normal(2): boot from standard disk subsystem pxeBiosSetup(3): boot from PXE according to BIOS setup settings (for OEM systems) pxeLanx(y): boot from PXE LAN interface x (0..3) ; Not supported. |
| oemDeployInfoTable | 1.3.6.1.4.1.211.1.31.1.1.1.10.2 | not-accessible | Table with data of server OEM information; Not supported. | |
| oemDeployInfo | 1.3.6.1.4.1.211.1.31.1.1.1.10.2.1 | not-accessible | ||
| INT odplInfoUnitId | 1.3.6.1.4.1.211.1.31.1.1.1.10.2.1.1 | INTEGER | read-only | Unit identifier (index: 1..n); Not supported. |
| INT odplParamId | 1.3.6.1.4.1.211.1.31.1.1.1.10.2.1.2 | INTEGER | read-only | OEM parameter ID (index: 1..10); Not supported. |
| STR oemDeployInfoParamData | 1.3.6.1.4.1.211.1.31.1.1.1.10.2.1.3 | DisplayString | read-write | OEM parameter data; Not supported. |
| deployLanInterfaceTable | 1.3.6.1.4.1.211.1.31.1.1.1.10.3 | not-accessible | Table with system LAN interfaces information: This table lists all real LAN interfaces in same physical order as the BIOS uses it for PXE boot. Only on-board interfaces are listed; no virtual interfaces. | |
| deployLanInterfaces | 1.3.6.1.4.1.211.1.31.1.1.1.10.3.1 | not-accessible | ||
| INT dplLanUnitId | 1.3.6.1.4.1.211.1.31.1.1.1.10.3.1.1 | INTEGER | read-only | Unit identifier (index; 1..n) |
| INT dplLanInterfaceNr | 1.3.6.1.4.1.211.1.31.1.1.1.10.3.1.2 | INTEGER | read-only | LAN interface number (index; 0..n) |
| PHY dplLanMacAddress | 1.3.6.1.4.1.211.1.31.1.1.1.10.3.1.3 | PhysAddress | read-only | LAN interface hardware (MAC) address; ff:ff:ff:ff:ff:ff if value not available |
| partition | 1.3.6.1.4.1.211.1.31.1.2 |
RFC description
Fujitsu PRIMEQUEST MMB (Modular Management Board) system management for servers and hardware inventory.
Start monitoring Fujitsu PRIMEQUEST server chassis (MMB service processor) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.