MMB-COM-MIB :: powerFailRecovery

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › MMB-COM-MIB › powerFailRecovery

powerFailRecovery

Module: MMB-COM-MIB

OID (symbolic): MMB-COM-MIB::powerFailRecovery

OID (numeric): 1.3.6.1.4.1.211.1.31.1.1.1.4.2.1.9

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Action on AC power recovery after AC has failed. not-available(2) : function not available; behavior is hardware-defined. as-before(3) : server gets the same power state as before the AC fail. remain-off(4) : server remains off on power resume. switch-on(5) : server is always switched on on power resume. schedule-sync(6) : server synchronizes the power state with the schedule setting.

What is powerFailRecovery?

What the server does when AC power returns after a failure: not-available(2) means hardware-defined, as-before(3) restores the earlier power state, remain-off(4) stays off, switch-on(5) always powers on, and schedule-sync(6) follows the schedule. Check it so that a rack-wide outage does not leave servers off, or turn on all at once.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.211.1.31.1.1.1.4.2.1.9
snmpwalk -v2c -c public <target> MMB-COM-MIB::powerFailRecovery

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.211.1.31.1.1.1.4.2.1.9.1
snmpget -v2c -c public <target> MMB-COM-MIB::powerFailRecovery.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> powerFailRecovery.1

Start monitoring Fujitsu PRIMEQUEST server chassis (MMB service processor) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the MMB-COM-MIB::powerFailRecovery OID value, configure state conditions and alerts, and monitor any Fujitsu PRIMEQUEST server chassis (MMB service processor) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.211fujitsuAlert-Definition-Originator-MIB
1.3.6.1.4.1.211.1productCFAB-MIB
1.3.6.1.4.1.211.1.31iaServerGSWB-MIB
1.3.6.1.4.1.211.1.31.1primequestGSWB-MIB
Numeric OIDNameModule
1.3.6.1.4.1.211.1.31.1.1mmbMMB-COM-MIB
1.3.6.1.4.1.211.1.31.1.1.1sysInfoMMB-COM-MIB
1.3.6.1.4.1.211.1.31.1.1.1.4serverInformationMMB-COM-MIB
1.3.6.1.4.1.211.1.31.1.1.1.4.2unitPowerOnOffTableMMB-COM-MIB
1.3.6.1.4.1.211.1.31.1.1.1.4.2.1unitPowerOnOffMMB-COM-MIB
1.3.6.1.4.1.211.1.31.1.1.1.4.2.1.9powerFailRecoveryMMB-COM-MIB