All MIBs › MBG-SNMP-LTNG-MIB
Organization: Meinberg Radio Clocks GmbH & Co. KG
Last Updated: 2016-05-18
Category: Technology: Time Synchronization, Vendor: Meinberg
Description: Meinberg Radio Clocks next-generation LanTime SNMP MIB providing enhanced NTP/PPS server monitoring and configuration objects.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is MBG-SNMP-LTNG-MIB?
MBG-SNMP-LTNG-MIB is a Meinberg Radio Clocks vendor-specific MIB for the LANTIME NG (next-generation) family of NTP/PTP time servers, providing enhanced status, configuration, and notification objects beyond earlier Meinberg MIBs. Under mbgLantimeNGStatus it exposes general appliance identity via mbgLtNgInfo (mbgLtNgFirmwareVersion, mbgLtNgSerialNumber, mbgLtNgCpuSerialNumber, mbgLtNgSubagentTimeticks) and per-reference-clock health through mbgLtNgRefclockTable, indexed by mbgLtNgRefclockIndex, with columns for refclock type, usage, operational state/substate, and dual status registers (mbgLtNgRefclockStatusA/B with their maximums). The module's decades of revisions layered in NTP client statistics, PTP port state tables, GPS position data, cluster support, and numerous traps (e.g., NTP offset limit exceeded, FDM error, certificate expiry, insufficient system resources), reflecting its role as the primary management interface for time-synchronization infrastructure. It depends on the shared MBG-SNMP-ROOT-MIB for its registration point and is deployed on Meinberg LANTIME appliances providing NTP/PTP timing to networks, and administrators can download the MBG-SNMP-LTNG-MIB file to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in MBG-SNMP-LTNG-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Meinberg LANTIME NG time server appliances
Monitoring Examples
An operator polls mbgLtNgRefclockTable to check mbgLtNgRefclockState and mbgLtNgRefclockSubstate for the installed GPS or MRS reference clock, cross-checking mbgLtNgRefclockStatusA against mbgLtNgRefclockMaxStatusA; a degraded refclock state combined with a received mbgLtNgTrapNTPOffsetLimitExceeded trap would indicate the time source has become unreliable and downstream NTP clients may be receiving inaccurate time.
What Can Be Monitored
- reference clock type/usage/state/substate
- reference clock status registers A/B
- NTP client offset and statistics counters
- PTP port state table entries
- firmware/serial number identity objects
- trap conditions (offset limit, FDM, certificate expiry, resource exhaustion)
This MIB depends on
Related MIBs
Imported Objects
From MBG-SNMP-ROOT-MIB
| MeinbergSwitch | |
| mbgSnmpRoot | MODULE-IDENTITY |
From SNMPv2-CONF
| MODULE-COMPLIANCE | |
| NOTIFICATION-GROUP | |
| OBJECT-GROUP |
From SNMPv2-SMI
| Counter64 | |
| Integer32 | |
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-TYPE | |
| Unsigned32 |
From SNMPv2-TC
| DisplayString |
How to Use in IPNetwork Monitor
Example using mbgLtNgSubagentTimeticks OID:
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| mbgLantimeNG | 1.3.6.1.4.1.5597.30 | Meinberg LANTIME SNMP Management Information Base | ||
| mbgLantimeNGStatus | 1.3.6.1.4.1.5597.30.0 | |||
| mbgLtNgInfo | 1.3.6.1.4.1.5597.30.0.0 | |||
| STR mbgLtNgSnmpSubagentVersion | 1.3.6.1.4.1.5597.30.0.0.1 | DisplayString | read-only | version of this SNMP subagent |
| STR mbgLtNgFirmwareVersion | 1.3.6.1.4.1.5597.30.0.0.2 | DisplayString | read-only | installed LANTIME firmware version |
| STR mbgLtNgSerialNumber | 1.3.6.1.4.1.5597.30.0.0.3 | DisplayString | read-only | LANTIME serial number |
| C64 mbgLtNgSubagentTimeticksEx | 1.3.6.1.4.1.5597.30.0.0.4 | Counter64 | read-only | Subdaemons' time alive in seconds |
| STR mbgLtNgCpuSerialNumber | 1.3.6.1.4.1.5597.30.0.0.5 | DisplayString | read-only | CPU's serial number |
| mbgLtNgRefclock | 1.3.6.1.4.1.5597.30.0.1 | |||
| U32 mbgLtNgNumberOfRefclocks | 1.3.6.1.4.1.5597.30.0.1.1 | Unsigned32 | read-only | currently installed number of refclocks |
| mbgLtNgRefclockTable | 1.3.6.1.4.1.5597.30.0.1.2 | not-accessible | a table of refclock related variables | |
| mbgLtNgRefclockTableEntry | 1.3.6.1.4.1.5597.30.0.1.2.1 | not-accessible | a list of objects pertaining to a refclock | |
| U32 mbgLtNgRefclockIndex | 1.3.6.1.4.1.5597.30.0.1.2.1.1 | Unsigned32 | not-accessible | index for refclock |
| INT mbgLtNgRefclockType | 1.3.6.1.4.1.5597.30.0.1.2.1.2 | INTEGER | read-only | type of refclock |
| INT mbgLtNgRefclockUsage | 1.3.6.1.4.1.5597.30.0.1.2.1.3 | INTEGER | read-only | what this refclock is used for |
| INT mbgLtNgRefclockState | 1.3.6.1.4.1.5597.30.0.1.2.1.4 | INTEGER | read-only | state of GPS refclock conneted to NTP time server as value 0: not available 1: synchronized 2: not synchronized |
| INT mbgLtNgRefclockSubstate | 1.3.6.1.4.1.5597.30.0.1.2.1.5 | INTEGER | read-only | more detailed state depending on refclock type 0: no substate available gps: 1-4 long waves (PZF,WWVB,MSF,...): 50-52 (not supported by all types) irig: 100-101 |
| U32 mbgLtNgRefclockStatusA | 1.3.6.1.4.1.5597.30.0.1.2.1.6 | Unsigned32 | read-only | status A depending on reflcock gps : indicates number of good satellites in view long wave - pzf : correlation - other : not supported irig : not supported |
| U32 mbgLtNgRefclockMaxStatusA | 1.3.6.1.4.1.5597.30.0.1.2.1.7 | Unsigned32 | read-only | maximum status A depending on reflcock gps : indicates number of satellites in view long wave - pzf : 100 - other : not supported irig : not supported |
| U32 mbgLtNgRefclockStatusB | 1.3.6.1.4.1.5597.30.0.1.2.1.8 | Unsigned32 | read-only | maximum status B depending on reflcock gps : not supported long wave - all : field strength irig : not supported |
| U32 mbgLtNgRefclockMaxStatusB | 1.3.6.1.4.1.5597.30.0.1.2.1.9 | Unsigned32 | read-only | maximum status B depending on reflcock gps : not supported long wave - all : 100 irig : not supported |
| INT mbgLtNgRefclockAdditionalInfo | 1.3.6.1.4.1.5597.30.0.1.2.1.10 | INTEGER | read-only | any kind of additional information concerning a refclock |
| STR mbgLtNgRefclockLeapSecondDate | 1.3.6.1.4.1.5597.30.0.1.2.1.11 | DisplayString | read-only | Date for next leap second |
| mbgLtNgRefclockGpsTable | 1.3.6.1.4.1.5597.30.0.1.3 | not-accessible | a table of gps only related variables | |
| mbgLtNgRefclockGpsTableEntry | 1.3.6.1.4.1.5597.30.0.1.3.1 | not-accessible | a list of objects pertaining to a GPS refclock | |
| U32 mbgLtNgRefclockGpsIndex | 1.3.6.1.4.1.5597.30.0.1.3.1.1 | Unsigned32 | not-accessible | index for GPS |
| STR mbgLtNgRefclockGpsLatitude | 1.3.6.1.4.1.5597.30.0.1.3.1.2 | DisplayString | read-only | GPS' latitude |
| STR mbgLtNgRefclockGpsLongitude | 1.3.6.1.4.1.5597.30.0.1.3.1.3 | DisplayString | read-only | GPS' longitude |
| I32 mbgLtNgRefclockGpsAltitude | 1.3.6.1.4.1.5597.30.0.1.3.1.4 | Integer32 | read-only | GPS' altitude |
| STR mbgLtNgRefclockGpsTdop | 1.3.6.1.4.1.5597.30.0.1.3.1.5 | DisplayString | read-only | GPS' timing dillution of precision |
| STR mbgLtNgRefclockGpsPdop | 1.3.6.1.4.1.5597.30.0.1.3.1.6 | DisplayString | read-only | GPS' positional dillution of precision |
| I32 mbgLtNgRefclockGpsUtcOffset | 1.3.6.1.4.1.5597.30.0.1.3.1.7 | Integer32 | read-only | GPS' offset to UTC in seconds |
| I32 mbgLtNgRefclockTimeDiff | 1.3.6.1.4.1.5597.30.0.1.4 | Integer32 | read-only | when there is more than one refclock this object shows the internal time difference in milliseconds |
| STR mbgLtNgRefclockGpsPos | 1.3.6.1.4.1.5597.30.0.1.5 | DisplayString | read-only | shows current GPS receiver position |
| mbgLtNgNtp | 1.3.6.1.4.1.5597.30.0.2 | |||
| INT mbgLtNgNtpCurrentState | 1.3.6.1.4.1.5597.30.0.2.1 | INTEGER | read-only | Current NTP's synchronization status |
| I32 mbgLtNgNtpStratum | 1.3.6.1.4.1.5597.30.0.2.2 | Integer32 | read-only | Stratum value of the NTP |
| STR mbgLtNgNtpRefclockName | 1.3.6.1.4.1.5597.30.0.2.3 | DisplayString | read-only | Name of the current refclock selected by the NTP |
| STR mbgLtNgNtpRefclockOffset | 1.3.6.1.4.1.5597.30.0.2.4 | DisplayString | read-only | Time offset between the current selected refclock and time of NTP as string in milliseconds |
| STR mbgLtNgNtpVersion | 1.3.6.1.4.1.5597.30.0.2.5 | DisplayString | read-only | integrated NTP version |
| mbgLtNgNtpClientCounter | 1.3.6.1.4.1.5597.30.0.2.8 | |||
| C64 mbgLtNgNtpCCStartedAt | 1.3.6.1.4.1.5597.30.0.2.8.1 | Counter64 | read-only | start time of current NTP client counter session as timestamp |
| U32 mbgLtNgNtpCCDuration | 1.3.6.1.4.1.5597.30.0.2.8.2 | Unsigned32 | read-only | total duration of NTP client counter in seconds |
| U32 mbgLtNgNtpCCNumberOfClients | 1.3.6.1.4.1.5597.30.0.2.8.3 | Unsigned32 | read-only | total number of different clients requesting time |
| C64 mbgLtNgNtpCCTotalRequests | 1.3.6.1.4.1.5597.30.0.2.8.4 | Counter64 | read-only | total requests since starting the daemon |
| C64 mbgLtNgNtpCCTotalRequestsCurrentDay | 1.3.6.1.4.1.5597.30.0.2.8.5 | Counter64 | read-only | today's total requests |
| C64 mbgLtNgNtpCCTotalRequestsLastHour | 1.3.6.1.4.1.5597.30.0.2.8.6 | Counter64 | read-only | today's requests within the last completed hour |
| C64 mbgLtNgNtpCCTotalRequestsLastMinute | 1.3.6.1.4.1.5597.30.0.2.8.7 | Counter64 | read-only | today's requests within the last completed minute |
| U32 mbgLtNgNtpCCTodaysClients | 1.3.6.1.4.1.5597.30.0.2.8.8 | Unsigned32 | read-only | today's number of different clients requesting time |
| mbgLtNgNtpMrs | 1.3.6.1.4.1.5597.30.0.2.9 | |||
| STR mbgLtNgNtpMrsServer | 1.3.6.1.4.1.5597.30.0.2.9.1 | DisplayString | read-only | external NTP server being used for synchronization |
| STR mbgLtNgNtpMrsOffset | 1.3.6.1.4.1.5597.30.0.2.9.2 | DisplayString | read-only | external NTP server's offset |
| mbgLtNgPtp | 1.3.6.1.4.1.5597.30.0.3 | |||
| U32 mbgLtNgPtpNumberOfModules | 1.3.6.1.4.1.5597.30.0.3.1 | Unsigned32 | read-only | number of available PTPv2 modules |
| mbgLtNgPtpTable | 1.3.6.1.4.1.5597.30.0.3.2 | not-accessible | a table of PTPv2 related variables | |
| mbgLtNgPtpTableEntry | 1.3.6.1.4.1.5597.30.0.3.2.1 | not-accessible | a list of objects pertaining to a PTPv2 module | |
| U32 mbgLtNgPtpIndex | 1.3.6.1.4.1.5597.30.0.3.2.1.1 | Unsigned32 | not-accessible | index for PTPv2 module |
| INT mbgLtNgPtpMode | 1.3.6.1.4.1.5597.30.0.3.2.1.2 | INTEGER | read-only | PTPv2 modus as integer. This object is obsolete and always returns '0'. Please see alternates mbgLtNgPtpPortState and mbgLtNgPtpRole. |
| INT mbgLtNgPtpPortState | 1.3.6.1.4.1.5597.30.0.3.2.1.3 | INTEGER | read-only | port state as integer |
| STR mbgLtNgPtpGrandmasterMac | 1.3.6.1.4.1.5597.30.0.3.2.1.4 | DisplayString | read-only | MAC address of current grandmaster |
| INT mbgLtNgPtpClockAccuracy | 1.3.6.1.4.1.5597.30.0.3.2.1.5 | INTEGER | read-only | indicates the source of time |
| U32 mbgLtNgPtpClockClass | 1.3.6.1.4.1.5597.30.0.3.2.1.6 | Unsigned32 | read-only | denotes the traceability of the time or frequency |
| INT mbgLtNgPtpTimeSource | 1.3.6.1.4.1.5597.30.0.3.2.1.7 | INTEGER | read-only | source of time being used |
| U32 mbgLtNgPtpUtcOffset | 1.3.6.1.4.1.5597.30.0.3.2.1.8 | Unsigned32 | read-only | offset from PTP's TAI time to UTC time |
| C64 mbgLtNgPtpTimeSeconds | 1.3.6.1.4.1.5597.30.0.3.2.1.9 | Counter64 | read-only | PTP seconds |
| STR mbgLtNgPtpTsuTime | 1.3.6.1.4.1.5597.30.0.3.2.1.10 | DisplayString | read-only | current time on PTP TSU |
| STR mbgLtNgPtpSysTime | 1.3.6.1.4.1.5597.30.0.3.2.1.11 | DisplayString | read-only | current system time |
| MEI mbgLtNgPtpPortLinkup | 1.3.6.1.4.1.5597.30.0.3.2.1.12 | MeinbergSwitch | read-only | PTP port's physical link-up |
| STR mbgLtNgPtpOffsetFromGM | 1.3.6.1.4.1.5597.30.0.3.2.1.13 | DisplayString | read-only | offset from grandmaster in nanoseconds |
| STR mbgLtNgPtpPathDelay | 1.3.6.1.4.1.5597.30.0.3.2.1.14 | DisplayString | read-only | network delay in nanoseconds |
| INT mbgLtNgPtpDelayMec | 1.3.6.1.4.1.5597.30.0.3.2.1.15 | INTEGER | read-only | delay mechanism |
| U32 mbgLtNgPtpDomain | 1.3.6.1.4.1.5597.30.0.3.2.1.16 | Unsigned32 | read-only | domain number |
| STR mbgLtNgPtpGrandmasterUuid | 1.3.6.1.4.1.5597.30.0.3.2.1.17 | DisplayString | read-only | grandmaster uuid |
| STR mbgLtNgPtpLocalMac | 1.3.6.1.4.1.5597.30.0.3.2.1.18 | DisplayString | read-only | local MAC address |
| STR mbgLtNgPtpDelayAsymmetry | 1.3.6.1.4.1.5597.30.0.3.2.1.19 | DisplayString | read-only | asymmetric network delay in nanoseconds |
| INT mbgLtNgPtpAvail | 1.3.6.1.4.1.5597.30.0.3.2.1.20 | INTEGER | read-only | Signals whether PTP instance is avail or not |
| mbgLtNgFdm | 1.3.6.1.4.1.5597.30.0.4 | |||
| U32 mbgLtNgFdmFreq | 1.3.6.1.4.1.5597.30.0.4.1 | Unsigned32 | read-only | powerline frequency in mHz; 0 indicates that no data is available |
| I32 mbgLtNgFdmFreqDev | 1.3.6.1.4.1.5597.30.0.4.2 | Integer32 | read-only | frequency deviation in mHz depending on the configured nominal frequency; check 'mbgLtNgFdmFreq' for error |
| U32 mbgLtNgFdmNomFreq | 1.3.6.1.4.1.5597.30.0.4.3 | Unsigned32 | read-only | nominal frequency in mHz; can be 50000 (50Hz) or 60000 (60Hz); 0 indicates that no value is configured |
| mbgLtNgSystemHardware | 1.3.6.1.4.1.5597.30.0.5 | |||
| mbgLtNgSysPowerSupply | 1.3.6.1.4.1.5597.30.0.5.0 | |||
| U32 mbgLtNgSysNumberOfPowerSupplies | 1.3.6.1.4.1.5597.30.0.5.0.1 | Unsigned32 | read-only | number of available power supplies |
| mbgLtNgSysPsTable | 1.3.6.1.4.1.5597.30.0.5.0.2 | not-accessible | a table of power supply stati | |
| mbgLtNgSysPsTableEntry | 1.3.6.1.4.1.5597.30.0.5.0.2.1 | not-accessible | a list of objects pertaining to power supplies | |
| U32 mbgLtNgSysPsIndex | 1.3.6.1.4.1.5597.30.0.5.0.2.1.1 | Unsigned32 | not-accessible | index of power supply |
| INT mbgLtNgSysPsStatus | 1.3.6.1.4.1.5597.30.0.5.0.2.1.2 | INTEGER | read-only | Status of power supply |
| mbgLtNgSysFan | 1.3.6.1.4.1.5597.30.0.5.1 | |||
| U32 mbgLtNgSysNumberOfFans | 1.3.6.1.4.1.5597.30.0.5.1.1 | Unsigned32 | read-only | number of available fans |
| mbgLtNgSysFanTable | 1.3.6.1.4.1.5597.30.0.5.1.2 | not-accessible | a table of power supply stati | |
| mbgLtNgSysFanTableEntry | 1.3.6.1.4.1.5597.30.0.5.1.2.1 | not-accessible | a list of objects pertaining to fans | |
| U32 mbgLtNgSysFanIndex | 1.3.6.1.4.1.5597.30.0.5.1.2.1.1 | Unsigned32 | not-accessible | index of fan |
| INT mbgLtNgSysFanStatus | 1.3.6.1.4.1.5597.30.0.5.1.2.1.2 | INTEGER | read-only | Status of fan |
| INT mbgLtNgSysFanError | 1.3.6.1.4.1.5597.30.0.5.1.2.1.3 | INTEGER | read-only | fan's error field |
| mbgLtNgSysTemperature | 1.3.6.1.4.1.5597.30.0.5.2 | |||
| U32 mbgLtNgSysTempCelsius | 1.3.6.1.4.1.5597.30.0.5.2.1 | Unsigned32 | read-only | temperature in degree Celsius |
| mbgLtNgCluster | 1.3.6.1.4.1.5597.30.0.6 | |||
| U32 mbgLtNgNumberOfClusters | 1.3.6.1.4.1.5597.30.0.6.1 | Unsigned32 | read-only | number of active running clusters |
| mbgLtNgClusterTable | 1.3.6.1.4.1.5597.30.0.6.2 | not-accessible | a table of cluster status information | |
| mbgLtNgClusterTableEntry | 1.3.6.1.4.1.5597.30.0.6.2.1 | not-accessible | a list of objects pertaining to running and active clusters | |
| U32 mbgLtNgClusterIndex | 1.3.6.1.4.1.5597.30.0.6.2.1.1 | Unsigned32 | not-accessible | index of power supply |
| STR mbgLtNgClusterCommunicationIp | 1.3.6.1.4.1.5597.30.0.6.2.1.2 | DisplayString | read-only | ip of cluster interface |
| INT mbgLtNgClusterPortState | 1.3.6.1.4.1.5597.30.0.6.2.1.3 | INTEGER | read-only | state of cluster |
| STR mbgLtNgClusterMasterSerial | 1.3.6.1.4.1.5597.30.0.6.2.1.4 | DisplayString | read-only | serial number of cluster's master |
| STR mbgLtNgClusterMasterIp | 1.3.6.1.4.1.5597.30.0.6.2.1.5 | DisplayString | read-only | ip address of cluster's master |
| U32 mbgLtNgClusterMasterPriority | 1.3.6.1.4.1.5597.30.0.6.2.1.6 | Unsigned32 | read-only | priority of cluster master |
| INT mbgLtNgClusterClockClass | 1.3.6.1.4.1.5597.30.0.6.2.1.7 | INTEGER | read-only | reference's clock class |
| INT mbgLtNgClusterClockStatus | 1.3.6.1.4.1.5597.30.0.6.2.1.8 | INTEGER | read-only | reference's clock status |
| INT mbgLtNgClusterReconfigurationState | 1.3.6.1.4.1.5597.30.0.6.2.1.9 | INTEGER | read-only | current reconfiguration state |
| INT mbgLtNgClusterIsFalseticker | 1.3.6.1.4.1.5597.30.0.6.2.1.10 | INTEGER | read-only | am I a falseticker? |
| mbgLtNgMisc | 1.3.6.1.4.1.5597.30.0.7 | |||
| mbgLtNgEthPortLinkTable | 1.3.6.1.4.1.5597.30.0.7.1 | not-accessible | a table of physical ethernet interface port link states | |
| mbgLtNgEthPortLinkTableEntry | 1.3.6.1.4.1.5597.30.0.7.1.1 | not-accessible | port link states for each physical ethernet interface | |
| U32 mbgLtNgEthPortLinkIndex | 1.3.6.1.4.1.5597.30.0.7.1.1.1 | Unsigned32 | not-accessible | interface index |
| INT mbgLtNgEthPortLinkState | 1.3.6.1.4.1.5597.30.0.7.1.1.2 | INTEGER | read-only | link state |
| mbgLtNgConfig | 1.3.6.1.4.1.5597.30.1 | |||
| mbgLtNgCfgEthernet | 1.3.6.1.4.1.5597.30.1.0 | |||
| STR mbgLtNgCfgEthernetHostname | 1.3.6.1.4.1.5597.30.1.0.1 | DisplayString | read-write | devices' hostname |
| STR mbgLtNgCfgEthernetDomain | 1.3.6.1.4.1.5597.30.1.0.2 | DisplayString | read-write | devices' domain membership |
| STR mbgLtNgCfgEthernetNameserver1 | 1.3.6.1.4.1.5597.30.1.0.3 | DisplayString | read-write | first nameserver's ip address |
| STR mbgLtNgCfgEthernetNameserver2 | 1.3.6.1.4.1.5597.30.1.0.4 | DisplayString | read-write | second nameserver's ip address |
| STR mbgLtNgCfgEthernetIpv4Gateway | 1.3.6.1.4.1.5597.30.1.0.5 | DisplayString | read-write | device's ethernet ipv4 gateway |
| STR mbgLtNgCfgEthernetIpv6Gateway | 1.3.6.1.4.1.5597.30.1.0.6 | DisplayString | read-write | device's ethernet ipv6 gateway |
| U32 mbgLtNgCfgNumberOfPhysicalIf | 1.3.6.1.4.1.5597.30.1.0.7 | Unsigned32 | read-only | number of virtual interfaces interfaces |
| U32 mbgLtNgCfgNumberOfVirtualIf | 1.3.6.1.4.1.5597.30.1.0.8 | Unsigned32 | read-only | number of virtual interfaces interfaces |
| mbgLtNgCfgPhysicalIfTable | 1.3.6.1.4.1.5597.30.1.0.9 | not-accessible | a table of service stati for the ethernet interfaces | |
| mbgLtNgCfgPhysicalIfTableEntry | 1.3.6.1.4.1.5597.30.1.0.9.1 | not-accessible | a list of objects pertaining to a mrs input reference | |
| U32 mbgLtNgCfgPhysicalIfIndex | 1.3.6.1.4.1.5597.30.1.0.9.1.1 | Unsigned32 | not-accessible | specifies the physical interface index |
| STR mbgLtNgCfgPhysicalIfMac | 1.3.6.1.4.1.5597.30.1.0.9.1.2 | DisplayString | read-only | interface's physical MAC address |
| INT mbgLtNgCfgPhysicalIfNetLinkMode | 1.3.6.1.4.1.5597.30.1.0.9.1.3 | INTEGER | read-write | interface's net link mode; hd = half-duplex; fd = full-duplex |
| MEI mbgLtNgCfgPhysicalIfIndicateLink | 1.3.6.1.4.1.5597.30.1.0.9.1.4 | MeinbergSwitch | read-write | indicate link via front panel LED |
| U32 mbgLtNgCfgPhysicalIfBondingGroup | 1.3.6.1.4.1.5597.30.1.0.9.1.5 | Unsigned32 | read-write | assign interface to bonding group; '0' means not assigned |
| INT mbgLtNgCfgPhysicalIfIpv6Mode | 1.3.6.1.4.1.5597.30.1.0.9.1.6 | INTEGER | read-write | enable IPv6 mode |
| mbgLtNgCfgVirtualIfTable | 1.3.6.1.4.1.5597.30.1.0.10 | not-accessible | a table of service stati for the ethernet interfaces | |
| mbgLtNgCfgVirtualIfTableEntry | 1.3.6.1.4.1.5597.30.1.0.10.1 | not-accessible | a list of objects pertaining to a mrs input reference | |
| U32 mbgLtNgCfgVirtualIfIndex | 1.3.6.1.4.1.5597.30.1.0.10.1.1 | Unsigned32 | not-accessible | specifies the virtual interface index |
| STR mbgLtNgCfgVirtualIfIpv4Addr | 1.3.6.1.4.1.5597.30.1.0.10.1.2 | DisplayString | read-write | interfaces' ipv4 address |
| STR mbgLtNgCfgVirtualIfIpv4Netmask | 1.3.6.1.4.1.5597.30.1.0.10.1.3 | DisplayString | read-write | interfaces' ipv4 netmask |
| MEI mbgLtNgCfgVirtualIfIpv4Dhcp | 1.3.6.1.4.1.5597.30.1.0.10.1.4 | MeinbergSwitch | read-write | interface uses ipv4 dhcp? |
| STR mbgLtNgCfgVirtualIfIpv4AddrFromDhcp | 1.3.6.1.4.1.5597.30.1.0.10.1.5 | DisplayString | read-only | interfaces' ipv4 address received from dhcp |
| STR mbgLtNgCfgVirtualIfIpv4NetmaskFromDhcp | 1.3.6.1.4.1.5597.30.1.0.10.1.6 | DisplayString | read-only | interfaces' ipv4 netmask received from dhcp |
| STR mbgLtNgCfgVirtualIfIpv4BroadcastFromDhcp | 1.3.6.1.4.1.5597.30.1.0.10.1.7 | DisplayString | read-only | interfaces' ipv4 broadcast received from dhcp |
| STR mbgLtNgCfgVirtualIfIpv4GatewayFromDhcp | 1.3.6.1.4.1.5597.30.1.0.10.1.8 | DisplayString | read-only | interfaces' ipv4 gateway received from dhcp |
| STR mbgLtNgCfgVirtualIfIpv4DnsFromDhcp | 1.3.6.1.4.1.5597.30.1.0.10.1.9 | DisplayString | read-only | interfaces' ipv4 dns server received from dhcp |
| STR mbgLtNgCfgVirtualIfIpv4DomainFromDhcp | 1.3.6.1.4.1.5597.30.1.0.10.1.10 | DisplayString | read-only | interfaces' ipv4 dns server received from dhcp |
| STR mbgLtNgCfgVirtualIfIpv6Addr | 1.3.6.1.4.1.5597.30.1.0.10.1.11 | DisplayString | read-write | interfaces' ipv6 address |
| MEI mbgLtNgCfgVirtualIfIpv6Dhcp | 1.3.6.1.4.1.5597.30.1.0.10.1.12 | MeinbergSwitch | read-write | interfaces uses ipv6 dhcp |
| STR mbgLtNgCfgVirtualIfIpv6RoutAdd | 1.3.6.1.4.1.5597.30.1.0.10.1.13 | DisplayString | read-only | interfaces' router advertisement ipv6 address |
| STR mbgLtNgCfgVirtualIfIpv6LinkLocal | 1.3.6.1.4.1.5597.30.1.0.10.1.14 | DisplayString | read-only | interfaces' ipv6 link local address |
| U32 mbgLtNgCfgVirtualIfAssigned | 1.3.6.1.4.1.5597.30.1.0.10.1.15 | Unsigned32 | read-write | mapping to the physical interface this virtual one is assigned to |
| STR mbgLtNgCfgVirtualIfMac | 1.3.6.1.4.1.5597.30.1.0.10.1.16 | DisplayString | read-only | MAC-address of this virtual interface |
| STR mbgLtNgCfgVirtualIfLabel | 1.3.6.1.4.1.5597.30.1.0.10.1.17 | DisplayString | read-write | user description for this label (like an alias) |
| MEI mbgLtNgCfgVirtualIfVlan | 1.3.6.1.4.1.5597.30.1.0.10.1.18 | MeinbergSwitch | read-write | is vlan enabled |
| U32 mbgLtNgCfgVirtualIfVlanTag | 1.3.6.1.4.1.5597.30.1.0.10.1.19 | Unsigned32 | read-write | vlan tag |
| U32 mbgLtNgCfgVirtualIfVlanPrio | 1.3.6.1.4.1.5597.30.1.0.10.1.20 | Unsigned32 | read-write | vlan priority |
| MEI mbgLtNgCfgVirtualIfCluster | 1.3.6.1.4.1.5597.30.1.0.10.1.21 | MeinbergSwitch | read-write | is cluster mode enabled |
| STR mbgLtNgCfgVirtualIfClusterIpv4Addr | 1.3.6.1.4.1.5597.30.1.0.10.1.22 | DisplayString | read-write | ipv4 cluster address |
| STR mbgLtNgCfgVirtualIfClusterIpv4Netmask | 1.3.6.1.4.1.5597.30.1.0.10.1.23 | DisplayString | read-write | cluster ipv4 netmask |
| U32 mbgLtNgCfgVirtualIfClusterPrio | 1.3.6.1.4.1.5597.30.1.0.10.1.24 | Unsigned32 | read-write | cluster priority |
| MEI mbgLtNgCfgVirtualIfServiceNtp | 1.3.6.1.4.1.5597.30.1.0.10.1.25 | MeinbergSwitch | read-write | is ntp active on this interface |
| MEI mbgLtNgCfgVirtualIfServiceHttp | 1.3.6.1.4.1.5597.30.1.0.10.1.26 | MeinbergSwitch | read-write | is http active on this interface |
| MEI mbgLtNgCfgVirtualIfServiceHttps | 1.3.6.1.4.1.5597.30.1.0.10.1.27 | MeinbergSwitch | read-write | is https active on this interface |
| MEI mbgLtNgCfgVirtualIfServiceTelnet | 1.3.6.1.4.1.5597.30.1.0.10.1.28 | MeinbergSwitch | read-write | is telnet active on this interface |
| MEI mbgLtNgCfgVirtualIfServiceSsh | 1.3.6.1.4.1.5597.30.1.0.10.1.29 | MeinbergSwitch | read-write | is ssh active on this interface |
| MEI mbgLtNgCfgVirtualIfServiceSnmp | 1.3.6.1.4.1.5597.30.1.0.10.1.30 | MeinbergSwitch | read-write | is snmp active on this interface |
| MEI mbgLtNgCfgVirtualIfServiceFtp | 1.3.6.1.4.1.5597.30.1.0.10.1.31 | MeinbergSwitch | read-write | is ftp active on this interface |
| MEI mbgLtNgCfgVirtualIfServiceTime | 1.3.6.1.4.1.5597.30.1.0.10.1.32 | MeinbergSwitch | read-write | is time active on this interface |
| MEI mbgLtNgCfgVirtualIfServiceDaytime | 1.3.6.1.4.1.5597.30.1.0.10.1.33 | MeinbergSwitch | read-write | is daytime active on this interface |
| MEI mbgLtNgCfgVirtualIfServiceFpc | 1.3.6.1.4.1.5597.30.1.0.10.1.34 | MeinbergSwitch | read-write | is fpc active on this interface |
| U32 mbgLtNgCfgEthernetGenClusterPort | 1.3.6.1.4.1.5597.30.1.0.11 | Unsigned32 | read-write | general cluster port |
| STR mbgLtNgCfgEthernetGenClusterIp | 1.3.6.1.4.1.5597.30.1.0.12 | DisplayString | read-write | general multicast cluster address |
| mbgLtNgCfgNotifications | 1.3.6.1.4.1.5597.30.1.1 | |||
| mbgLtNgCfgSyslog | 1.3.6.1.4.1.5597.30.1.1.0 | |||
| STR mbgLtNgCfgSyslogServerAddr | 1.3.6.1.4.1.5597.30.1.1.0.1 | DisplayString | read-write | comma separated string of all configured syslog servers; use such a list to set syslog servers |
| INT mbgLtNgCfgSyslogLoglevel | 1.3.6.1.4.1.5597.30.1.1.0.2 | INTEGER | read-write | loglevel for syslog server |
| mbgLtNgCfgEmail | 1.3.6.1.4.1.5597.30.1.1.1 | |||
| STR mbgLtNgCfgEmailTo | 1.3.6.1.4.1.5597.30.1.1.1.1 | DisplayString | read-write | email address to send alerts etc. to (receiving address) |
| STR mbgLtNgCfgEmailFrom | 1.3.6.1.4.1.5597.30.1.1.1.2 | DisplayString | read-write | email address to send alerts etc. from (sending address) |
| STR mbgLtNgCfgEmailSmarthostAddr | 1.3.6.1.4.1.5597.30.1.1.1.3 | DisplayString | read-write | SMTP smarthost used to send mail (ip or hostname) |
| U32 mbgLtNgCfgEmailSmarthostPort | 1.3.6.1.4.1.5597.30.1.1.1.4 | Unsigned32 | read-write | SMTP smarthost listenning port |
| MEI mbgLtNgCfgEmailSmarthostAuth | 1.3.6.1.4.1.5597.30.1.1.1.5 | MeinbergSwitch | read-write | use authentication for smarthost |
| STR mbgLtNgCfgEmailSmarthostAuthUser | 1.3.6.1.4.1.5597.30.1.1.1.6 | DisplayString | read-write | user to authenticate at smarthost |
| STR mbgLtNgCfgEmailSmarthostAuthPw | 1.3.6.1.4.1.5597.30.1.1.1.7 | DisplayString | read-write | password to authenticate user at smarthost |
| mbgLtNgCfgWinpopup | 1.3.6.1.4.1.5597.30.1.1.2 | |||
| STR mbgLtNgCfgWmailAddress1 | 1.3.6.1.4.1.5597.30.1.1.2.1 | DisplayString | read-write | first windows popup alert receiver (ip or hostname) |
| STR mbgLtNgCfgWmailAddress2 | 1.3.6.1.4.1.5597.30.1.1.2.2 | DisplayString | read-write | second windows popup alert receiver (ip or hostname) |
| mbgLtNgCfgSNMP | 1.3.6.1.4.1.5597.30.1.1.3 | |||
| mbgLtNgCfgSnmpTrapRecTable | 1.3.6.1.4.1.5597.30.1.1.3.1 | not-accessible | a table of SNMP trap receiver information | |
| mbgLtNgCfgSnmpTrapRecTableEntry | 1.3.6.1.4.1.5597.30.1.1.3.1.1 | not-accessible | a list of objects pertaining to an interface and concerning broad-, multi- and manycast | |
| U32 mbgLtNgCfgSnmpTrapRecIndex | 1.3.6.1.4.1.5597.30.1.1.3.1.1.1 | Unsigned32 | not-accessible | index of different SNMP trap receivers |
| STR mbgLtNgCfgSnmpTrapRecAddr | 1.3.6.1.4.1.5597.30.1.1.3.1.1.2 | DisplayString | read-write | SNMP trap receiver address (ip or hostname) |
| STR mbgLtNgCfgSnmpTrapRecCommunity | 1.3.6.1.4.1.5597.30.1.1.3.1.1.3 | DisplayString | read-write | SNMP trap receiver community |
| INT mbgLtNgCfgSnmpTrapRecVersion | 1.3.6.1.4.1.5597.30.1.1.3.1.1.4 | INTEGER | read-write | SNMP trap receiver version |
| STR mbgLtNgCfgSnmpReadCommunity | 1.3.6.1.4.1.5597.30.1.1.3.2 | DisplayString | read-write | read community for SNMPv1 and SNMPv2c |
| STR mbgLtNgCfgSnmpWriteCommunity | 1.3.6.1.4.1.5597.30.1.1.3.3 | DisplayString | read-write | read community for SNMPv1 and SNMPv2c |
| STR mbgLtNgCfgSnmpContact | 1.3.6.1.4.1.5597.30.1.1.3.4 | DisplayString | read-write | SNMP contact string for Lantime |
| STR mbgLtNgCfgSnmpLocation | 1.3.6.1.4.1.5597.30.1.1.3.5 | DisplayString | read-write | SNMP location string for Lantime |
| STR mbgLtNgCfgSnmpV3UserName | 1.3.6.1.4.1.5597.30.1.1.3.6 | DisplayString | read-write | username for SNMPv3 |
| INT mbgLtNgCfgSnmpV3UserRights | 1.3.6.1.4.1.5597.30.1.1.3.7 | INTEGER | read-write | privacy protocol for SNMPv3 |
| STR mbgLtNgCfgSnmpV3Context | 1.3.6.1.4.1.5597.30.1.1.3.8 | DisplayString | read-write | context string for SNMPv3 |
| INT mbgLtNgCfgSnmpV3SecurityLevel | 1.3.6.1.4.1.5597.30.1.1.3.9 | INTEGER | read-write | authentication level for SNMPv3 |
| INT mbgLtNgCfgSnmpV3AuthProtocol | 1.3.6.1.4.1.5597.30.1.1.3.10 | INTEGER | read-write | authentication protocol for SNMPv3 |
| STR mbgLtNgCfgSnmpV3AuthPassphrase | 1.3.6.1.4.1.5597.30.1.1.3.11 | DisplayString | read-write | authentication passphrase for SNMPv3 |
| INT mbgLtNgCfgSnmpV3PrivProtocol | 1.3.6.1.4.1.5597.30.1.1.3.12 | INTEGER | read-write | privacy protocol for SNMPv3 |
| STR mbgLtNgCfgSnmpV3PrivPassphrase | 1.3.6.1.4.1.5597.30.1.1.3.13 | DisplayString | read-write | privacy passphrase for SNMPv3 |
| U32 mbgLtNgCfgSnmpRetries | 1.3.6.1.4.1.5597.30.1.1.3.14 | Unsigned32 | read-write | number of retries for sending traps |
| U32 mbgLtNgCfgSnmpTimeout | 1.3.6.1.4.1.5597.30.1.1.3.15 | Unsigned32 | read-write | timeout for sending traps (in seconds) |
| INT mbgLtNgCfgSnmpEnabledVersion | 1.3.6.1.4.1.5597.30.1.1.3.16 | INTEGER | read-write | currently enabled SNMP version |
| mbgLtNgCfgWalldisplay | 1.3.6.1.4.1.5597.30.1.1.4 | |||
| STR mbgLtNgCfgVP100Display1Addr | 1.3.6.1.4.1.5597.30.1.1.4.1 | DisplayString | read-write | address of wall display (ip or hostname) |
| STR mbgLtNgCfgVP100Display1SN | 1.3.6.1.4.1.5597.30.1.1.4.2 | DisplayString | read-write | serial number of first VP100 wall display |
| STR mbgLtNgCfgVP100Display2Addr | 1.3.6.1.4.1.5597.30.1.1.4.3 | DisplayString | read-write | address of wall display (ip or hostname) |
| STR mbgLtNgCfgVP100Display2SN | 1.3.6.1.4.1.5597.30.1.1.4.4 | DisplayString | read-write | serial number of second VP100 wall display |
| mbgLtNgCfgNtpClientMonitoring | 1.3.6.1.4.1.5597.30.1.1.5 | |||
| U32 mbgLtNgCfgNtpMaxClientOffset | 1.3.6.1.4.1.5597.30.1.1.5.1 | Unsigned32 | read-write | max NTP client offset limit in milliseconds |
| U32 mbgLtNgCfgNtpMaxClientStratum | 1.3.6.1.4.1.5597.30.1.1.5.2 | Unsigned32 | read-write | max NTP client stratum level |
| mbgLtNgCfgTrapTrigger | 1.3.6.1.4.1.5597.30.1.1.6 | |||
| STR mbgLtNgCfgTrapNormalOperation | 1.3.6.1.4.1.5597.30.1.1.6.1 | DisplayString | read-write | string containing signaling information ( comma-separated ); use the following aliases to set params: Email -> email Wmail -> wmail Snmp -> snmp VP100 -> disp User -> own Alarm -> led Relay -> relais Following string is perfectly valid to enable signaling for SNMP and Email: 'snmp,email'. Please note that some objects do not suppurt relay and led but this is announced at each MIB object itself. This object, for example, does not support them. |
| STR mbgLtNgCfgTrapNtpNotSync | 1.3.6.1.4.1.5597.30.1.1.6.2 | DisplayString | read-write | see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation |
| STR mbgLtNgCfgTrapNtpSync | 1.3.6.1.4.1.5597.30.1.1.6.3 | DisplayString | read-write | see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation |
| STR mbgLtNgCfgTrapNtpStopped | 1.3.6.1.4.1.5597.30.1.1.6.4 | DisplayString | read-write | see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation |
| STR mbgLtNgCfgTrapServerBoot | 1.3.6.1.4.1.5597.30.1.1.6.5 | DisplayString | read-write | see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation |
| STR mbgLtNgCfgTrapRefclockNotResponding | 1.3.6.1.4.1.5597.30.1.1.6.6 | DisplayString | read-write | see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation |
| STR mbgLtNgCfgTrapRefclockSynchronized | 1.3.6.1.4.1.5597.30.1.1.6.7 | DisplayString | read-write | see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation |
| STR mbgLtNgCfgTrapRefclockNotSynchronized | 1.3.6.1.4.1.5597.30.1.1.6.8 | DisplayString | read-write | see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation |
| STR mbgLtNgCfgTrapSecRefclockNotResponding | 1.3.6.1.4.1.5597.30.1.1.6.9 | DisplayString | read-write | see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation |
| STR mbgLtNgCfgTrapSecRefclockSynchronized | 1.3.6.1.4.1.5597.30.1.1.6.10 | DisplayString | read-write | see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation |
| STR mbgLtNgCfgTrapSecRefclockNotSynchronized | 1.3.6.1.4.1.5597.30.1.1.6.11 | DisplayString | read-write | see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation |
| STR mbgLtNgCfgTrapAntennaFaulty | 1.3.6.1.4.1.5597.30.1.1.6.12 | DisplayString | read-write | see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation |
| STR mbgLtNgCfgTrapAntennaReconnect | 1.3.6.1.4.1.5597.30.1.1.6.13 | DisplayString | read-write | see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation |
| STR mbgLtNgCfgTrapAntennaShortCircuit | 1.3.6.1.4.1.5597.30.1.1.6.14 | DisplayString | read-write | see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation |
| STR mbgLtNgCfgTrapConfigChanged | 1.3.6.1.4.1.5597.30.1.1.6.15 | DisplayString | read-write | see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation |
| STR mbgLtNgCfgTrapLeapSecAnnounced | 1.3.6.1.4.1.5597.30.1.1.6.16 | DisplayString | read-write | see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation |
| STR mbgLtNgCfgTrapNtpClientLimitExceeded | 1.3.6.1.4.1.5597.30.1.1.6.17 | DisplayString | read-write | see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation |
| STR mbgLtNgCfgTrapRefSrcLimitExceeded | 1.3.6.1.4.1.5597.30.1.1.6.18 | DisplayString | read-write | see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation |
| STR mbgLtNgCfgTrapRefSrcDisconnected | 1.3.6.1.4.1.5597.30.1.1.6.19 | DisplayString | read-write | see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation |
| STR mbgLtNgCfgTrapRefSrcReconnected | 1.3.6.1.4.1.5597.30.1.1.6.20 | DisplayString | read-write | see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation |
| STR mbgLtNgCfgTrapShsTimeLimitError | 1.3.6.1.4.1.5597.30.1.1.6.21 | DisplayString | read-write | see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation |
| STR mbgLtNgCfgTrapShsTimeLimitWarning | 1.3.6.1.4.1.5597.30.1.1.6.22 | DisplayString | read-write | see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation |
| STR mbgLtNgCfgTrapNetworkDown | 1.3.6.1.4.1.5597.30.1.1.6.23 | DisplayString | read-write | see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation |
| STR mbgLtNgCfgTrapNetworkUp | 1.3.6.1.4.1.5597.30.1.1.6.24 | DisplayString | read-write | see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation |
| STR mbgLtNgCfgTrapPowerSupplyUp | 1.3.6.1.4.1.5597.30.1.1.6.25 | DisplayString | read-write | see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation |
| STR mbgLtNgCfgTrapPowerSupplyDown | 1.3.6.1.4.1.5597.30.1.1.6.26 | DisplayString | read-write | see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation |
| STR mbgLtNgCfgTrapFdmError | 1.3.6.1.4.1.5597.30.1.1.6.27 | DisplayString | read-write | see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation |
| STR mbgLtNgCfgTrapLowSystemResources | 1.3.6.1.4.1.5597.30.1.1.6.28 | DisplayString | read-write | see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation |
| STR mbgLtNgCfgTrapPtpNetworkDown | 1.3.6.1.4.1.5597.30.1.1.6.29 | DisplayString | read-write | see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation |
| STR mbgLtNgCfgTrapPtpNetworkUp | 1.3.6.1.4.1.5597.30.1.1.6.30 | DisplayString | read-write | see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation |
| STR mbgLtNgCfgTrapPtpStateChanged | 1.3.6.1.4.1.5597.30.1.1.6.31 | DisplayString | read-write | see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation |
| STR mbgLtNgCfgTrapPtpError | 1.3.6.1.4.1.5597.30.1.1.6.32 | DisplayString | read-write | see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation |
| STR mbgLtNgCfgTrapFanDown | 1.3.6.1.4.1.5597.30.1.1.6.33 | DisplayString | read-write | see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation |
| STR mbgLtNgCfgTrapFanUp | 1.3.6.1.4.1.5597.30.1.1.6.34 | DisplayString | read-write | see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation |
| INT mbgLtNgCfgRepeatEvent | 1.3.6.1.4.1.5597.30.1.1.6.35 | INTEGER | read-write | when to send last error trap message again |
| U32 mbgLtNgCfgRepetitions | 1.3.6.1.4.1.5597.30.1.1.6.36 | Unsigned32 | read-write | how often do you want to resend an error trap |
| STR mbgLtNgCfgTrapWarmedUp | 1.3.6.1.4.1.5597.30.1.1.6.37 | DisplayString | read-write | see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation |
| STR mbgLtNgCfgTrapNotWarmedUp | 1.3.6.1.4.1.5597.30.1.1.6.38 | DisplayString | read-write | see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation |
| mbgLtNgCfgSecurity | 1.3.6.1.4.1.5597.30.1.2 | |||
| mbgLtNgCfgLoginAccess | 1.3.6.1.4.1.5597.30.1.2.0 | |||
| MEI mbgLtNgCfgDisableRootLogin | 1.3.6.1.4.1.5597.30.1.2.0.1 | MeinbergSwitch | read-write | do not allow user 'root' to login |
| MEI mbgLtNgCfgAllowNetworkDiscovery | 1.3.6.1.4.1.5597.30.1.2.0.2 | MeinbergSwitch | read-write | allow LANTIME to be discovered via network mdns |
| mbgLtNgCfgFrontPanel | 1.3.6.1.4.1.5597.30.1.2.1 | |||
| MEI mbgLtNgCfgLockFrontPanel | 1.3.6.1.4.1.5597.30.1.2.1.1 | MeinbergSwitch | read-write | do not allow usage of the front panel |
| MEI mbgLtNgCfgDisableUsbPort | 1.3.6.1.4.1.5597.30.1.2.1.2 | MeinbergSwitch | read-write | do not allow usage of front USB port |
| mbgLtNgCfgSsh | 1.3.6.1.4.1.5597.30.1.2.2 | |||
| U32 mbgLtNgCfgSshKeyLength | 1.3.6.1.4.1.5597.30.1.2.2.1 | Unsigned32 | read-write | ssh key length in bits |
| U32 mbgLtNgCfgSshShellTimeout | 1.3.6.1.4.1.5597.30.1.2.2.2 | Unsigned32 | read-write | ssh shell timeout in seconds |
| mbgLtNgCfgNtp | 1.3.6.1.4.1.5597.30.1.3 | |||
| mbgLtNgCfgNtpTable | 1.3.6.1.4.1.5597.30.1.3.1 | not-accessible | a table of configured, external NTP servers | |
| mbgLtNgCfgNtpTableEntry | 1.3.6.1.4.1.5597.30.1.3.1.1 | not-accessible | a list of objects pertaining to a configured,external NTP server | |
| U32 mbgLtNgCfgNtpIndex | 1.3.6.1.4.1.5597.30.1.3.1.1.1 | Unsigned32 | not-accessible | index (and no.) of external NTP server |
| STR mbgLtNgCfgNtpServerIP | 1.3.6.1.4.1.5597.30.1.3.1.1.2 | DisplayString | read-write | ip address for external NTP server |
| U32 mbgLtNgCfgNtpServerKey | 1.3.6.1.4.1.5597.30.1.3.1.1.3 | Unsigned32 | read-write | key for external NTP server |
| MEI mbgLtNgCfgNtpServerAutokey | 1.3.6.1.4.1.5597.30.1.3.1.1.4 | MeinbergSwitch | read-write | is autokey enabled for the external NTP server |
| U32 mbgLtNgCfgNtpServerMinpoll | 1.3.6.1.4.1.5597.30.1.3.1.1.5 | Unsigned32 | read-write | is autokey enabled for the external NTP server |
| U32 mbgLtNgCfgNtpServerMaxpoll | 1.3.6.1.4.1.5597.30.1.3.1.1.6 | Unsigned32 | read-write | is autokey enabled for the external NTP server |
| MEI mbgLtNgCfgNtpServerIburst | 1.3.6.1.4.1.5597.30.1.3.1.1.7 | MeinbergSwitch | read-write | is autokey enabled for the external NTP server |
| mbgLtNgCfgNtpBMTable | 1.3.6.1.4.1.5597.30.1.3.2 | not-accessible | a table of configured, external NTP servers | |
| mbgLtNgCfgNtpBMTableEntry | 1.3.6.1.4.1.5597.30.1.3.2.1 | not-accessible | a list of objects pertaining to an interface and concerning broad-, multi- and manycast | |
| U32 mbgLtNgCfgNtpBMIndex | 1.3.6.1.4.1.5597.30.1.3.2.1.1 | Unsigned32 | not-accessible | index of interface concerning different NTP modes |
| STR mbgLtNgCfgNtpBroadAddr | 1.3.6.1.4.1.5597.30.1.3.2.1.2 | DisplayString | read-only | address for NTP broadcast mode |
| U32 mbgLtNgCfgNtpBroadSymKey | 1.3.6.1.4.1.5597.30.1.3.2.1.3 | Unsigned32 | read-only | symmetric key number for broadcast |
| U32 mbgLtNgCfgNtpBroadInterval | 1.3.6.1.4.1.5597.30.1.3.2.1.4 | Unsigned32 | read-only | NTP broadcast interval on specific interval |
| MEI mbgLtNgCfgNtpBroadUseAutokey | 1.3.6.1.4.1.5597.30.1.3.2.1.5 | MeinbergSwitch | read-only | use autokey for broadcast |
| MEI mbgLtNgCfgNtpEnableMulticast | 1.3.6.1.4.1.5597.30.1.3.3 | MeinbergSwitch | read-write | enable or disable multicast mode |
| STR mbgLtNgCfgNtpMultiAddr | 1.3.6.1.4.1.5597.30.1.3.4 | DisplayString | read-write | address for NTP multicast mode |
| U32 mbgLtNgCfgNtpMultiInterval | 1.3.6.1.4.1.5597.30.1.3.5 | Unsigned32 | read-write | NTP multicast interval on specific interval |
| U32 mbgLtNgCfgNtpMultiSymKey | 1.3.6.1.4.1.5597.30.1.3.6 | Unsigned32 | read-write | symmetric key number for multicast |
| MEI mbgLtNgCfgNtpMultiUseAutokey | 1.3.6.1.4.1.5597.30.1.3.7 | MeinbergSwitch | read-write | use autokey for multicast |
| MEI mbgLtNgCfgNtpEnableManycast | 1.3.6.1.4.1.5597.30.1.3.8 | MeinbergSwitch | read-write | enable or disable manycast mode for this interface |
| STR mbgLtNgCfgNtpManyAddr | 1.3.6.1.4.1.5597.30.1.3.9 | DisplayString | read-write | address for NTP manycast mode |
| U32 mbgLtNgCfgNtpManySymKey | 1.3.6.1.4.1.5597.30.1.3.11 | Unsigned32 | read-write | symmetric key number for manycast |
| MEI mbgLtNgCfgNtpManyUseAutokey | 1.3.6.1.4.1.5597.30.1.3.12 | MeinbergSwitch | read-write | use autokey for manycast |
| U32 mbgLtNgCfgNtpLocalClkStratum | 1.3.6.1.4.1.5597.30.1.3.13 | Unsigned32 | read-write | stratum of local clock |
| MEI mbgLtNgCfgNtpDisableLocalClk | 1.3.6.1.4.1.5597.30.1.3.14 | MeinbergSwitch | read-write | disable local clock |
| MEI mbgLtNgCfgNtpSpoofLocalTime | 1.3.6.1.4.1.5597.30.1.3.15 | MeinbergSwitch | read-write | NTP outputs local time instead of UTC; see mbgLtNgCfgNtpTimeScale |
| STR mbgLtNgCfgNtpLocalTrustedKeys | 1.3.6.1.4.1.5597.30.1.3.16 | DisplayString | read-write | local trusted key |
| U32 mbgLtNgCfgNtpTrusttime | 1.3.6.1.4.1.5597.30.1.3.17 | Unsigned32 | read-write | accept async reference clock for this amount of time in seconds |
| INT mbgLtNgCfgNtpTimeScale | 1.3.6.1.4.1.5597.30.1.3.18 | INTEGER | read-write | timescale |
| MEI mbgLtNgCfgNtpEnableClientCounter | 1.3.6.1.4.1.5597.30.1.3.19 | MeinbergSwitch | read-write | enable NTP request client counting |
| I32 mbgLtNgCfgNtpEnableClientCounterDuration | 1.3.6.1.4.1.5597.30.1.3.20 | Integer32 | read-write | NTP client counter duration in seconds; 0 means continuously |
| mbgLtNgCfgPtp | 1.3.6.1.4.1.5597.30.1.4 | |||
| mbgLtNgCfgPtpTable | 1.3.6.1.4.1.5597.30.1.4.1 | not-accessible | a table of PTPv2 related configurtion variables | |
| mbgLtNgCfgPtpTableEntry | 1.3.6.1.4.1.5597.30.1.4.1.1 | not-accessible | a list of configuration objects pertaining to a PTPv2 module | |
| U32 mbgLtNgCfgPtpIndex | 1.3.6.1.4.1.5597.30.1.4.1.1.1 | Unsigned32 | not-accessible | index for PTPv2 module |
| STR mbgLtNgCfgPtpHostname | 1.3.6.1.4.1.5597.30.1.4.1.1.2 | DisplayString | read-write | network hostname |
| STR mbgLtNgCfgPtpDomainname | 1.3.6.1.4.1.5597.30.1.4.1.1.3 | DisplayString | read-write | network domain |
| STR mbgLtNgCfgPtpNameserver1 | 1.3.6.1.4.1.5597.30.1.4.1.1.4 | DisplayString | read-write | ethernet nameserver for hostname resolving |
| STR mbgLtNgCfgPtpNameserver2 | 1.3.6.1.4.1.5597.30.1.4.1.1.5 | DisplayString | read-write | ethernet nameserver for hostname resolving |
| STR mbgLtNgCfgPtpIpv4 | 1.3.6.1.4.1.5597.30.1.4.1.1.6 | DisplayString | read-write | ip address |
| STR mbgLtNgCfgPtpNetmask | 1.3.6.1.4.1.5597.30.1.4.1.1.7 | DisplayString | read-write | netmask |
| STR mbgLtNgCfgPtpGateway | 1.3.6.1.4.1.5597.30.1.4.1.1.8 | DisplayString | read-write | default gateway |
| MEI mbgLtNgCfgPtpEnableVlan | 1.3.6.1.4.1.5597.30.1.4.1.1.9 | MeinbergSwitch | read-write | Enable VLAN if it is supported |
| U32 mbgLtNgCfgPtpVlanId | 1.3.6.1.4.1.5597.30.1.4.1.1.10 | Unsigned32 | read-write | VLAN id ranges from 0-4096 |
| U32 mbgLtNgCfgPtpVlanPriority | 1.3.6.1.4.1.5597.30.1.4.1.1.11 | Unsigned32 | read-write | VLAN priority ranges from 0-7 |
| MEI mbgLtNgCfgPtpEnableDhcp | 1.3.6.1.4.1.5597.30.1.4.1.1.12 | MeinbergSwitch | read-write | Enable DCHP for PTPv2 module |
| INT mbgLtNgCfgPtpMode | 1.3.6.1.4.1.5597.30.1.4.1.1.13 | INTEGER | read-write | PTP mode |
| INT mbgLtNgCfgPtpDelayMechanism | 1.3.6.1.4.1.5597.30.1.4.1.1.14 | INTEGER | read-write | how to calculate delay mechanism |
| INT mbgLtNgCfgPtpNetworkProtocol | 1.3.6.1.4.1.5597.30.1.4.1.1.15 | INTEGER | read-write | how to calculate delay mechanism |
| U32 mbgLtNgCfgPtpDomainNumber | 1.3.6.1.4.1.5597.30.1.4.1.1.16 | Unsigned32 | read-write | ptp domain membership |
| U32 mbgLtNgCfgPtpPriority1 | 1.3.6.1.4.1.5597.30.1.4.1.1.17 | Unsigned32 | read-write | ptp user defined major priority |
| U32 mbgLtNgCfgPtpPriority2 | 1.3.6.1.4.1.5597.30.1.4.1.1.18 | Unsigned32 | read-write | ptp user defined minor priority |
| I32 mbgLtNgCfgPtpSyncInterval | 1.3.6.1.4.1.5597.30.1.4.1.1.19 | Integer32 | read-write | value is defined as power of 2; for example: 2 = one message every 4 seconds, -2 = 4 messages every second |
| I32 mbgLtNgCfgPtpAnnounceInterval | 1.3.6.1.4.1.5597.30.1.4.1.1.20 | Integer32 | read-write | see 'mbgLtNgCfPtpSyncInterval' for explanation |
| I32 mbgLtNgCfgPtpDelayReqInterval | 1.3.6.1.4.1.5597.30.1.4.1.1.21 | Integer32 | read-write | see 'mbgLtNgCfPtpSyncInterval' for explanation |
| INT mbgLtNgCfgPtpTimescale | 1.3.6.1.4.1.5597.30.1.4.1.1.22 | INTEGER | read-write | see 'mbgLtNgCfPtpSyncInterval' for explanation |
| INT mbgLtNgCfgPtpIpv6Avail | 1.3.6.1.4.1.5597.30.1.4.1.1.23 | INTEGER | read-only | Is IPv6 supported? |
| INT mbgLtNgCfgPtpIpv6Mode | 1.3.6.1.4.1.5597.30.1.4.1.1.24 | INTEGER | read-write | IPv6 addressing mode |
| STR mbgLtNgCfgPtpIpv6Address | 1.3.6.1.4.1.5597.30.1.4.1.1.25 | DisplayString | read-write | IPv6 address if supported, else n/a |
| INT mbgLtNgCfgPtpIpv6McastScope | 1.3.6.1.4.1.5597.30.1.4.1.1.26 | INTEGER | read-write | Multicast scope. See RFC 7346 and RFC 4291 |
| MEI mbgLtNgCfgPtpDisableSsh | 1.3.6.1.4.1.5597.30.1.4.1.1.27 | MeinbergSwitch | read-write | Disable SSH for PTP port |
| U32 mbgLtNgCfgPtpDscpClass | 1.3.6.1.4.1.5597.30.1.4.1.1.28 | Unsigned32 | read-write | DSCP classification value ranges from 0-64 |
| U32 mbgLtNgCfgPtpMcastTtl | 1.3.6.1.4.1.5597.30.1.4.1.1.29 | Unsigned32 | read-write | Multicast TTL value ranges from 0-255 |
| INT mbgLtNgCfgPtpOpMode | 1.3.6.1.4.1.5597.30.1.4.1.1.30 | INTEGER | read-write | General PTP operation mode |
| INT mbgLtNgCfgPtpProfile | 1.3.6.1.4.1.5597.30.1.4.1.1.31 | INTEGER | read-only | PTP profile |
| MEI mbgLtNgCfgPtpHybridMode | 1.3.6.1.4.1.5597.30.1.4.1.1.32 | MeinbergSwitch | read-write | Run card in hybrid mode |
| STR mbgLtNgCfgPtpUcastMstAddr | 1.3.6.1.4.1.5597.30.1.4.1.1.33 | DisplayString | read-write | IP address of unicast master when in slave mode. Only 1!!! is shown and can be set. |
| U32 mbgLtNgCfgPtpAnnRcptTmout | 1.3.6.1.4.1.5597.30.1.4.1.1.34 | Unsigned32 | read-write | Timeout for announce messages |
| U32 mbgLtNgCfgPtpMessageDuration | 1.3.6.1.4.1.5597.30.1.4.1.1.35 | Unsigned32 | read-write | Time period until master stops sending messages [s] |
| MEI mbgLtNgCfgPtpSyncEAvail | 1.3.6.1.4.1.5597.30.1.4.1.1.36 | MeinbergSwitch | read-only | Is SyncE supported? |
| MEI mbgLtNgCfgPtpSyncEEnabled | 1.3.6.1.4.1.5597.30.1.4.1.1.37 | MeinbergSwitch | read-write | Is Sync-E enabled if supported? |
| MEI mbgLtNgCfgPtpSyncEQltLvlSelEnable | 1.3.6.1.4.1.5597.30.1.4.1.1.38 | MeinbergSwitch | read-write | Enable quality selection? |
| INT mbgLtNgCfgPtpSyncESdhNwOption | 1.3.6.1.4.1.5597.30.1.4.1.1.39 | INTEGER | read-write | Sdh network option |
| INT mbgLtNgCfgPtpSyncEInputSsm | 1.3.6.1.4.1.5597.30.1.4.1.1.40 | INTEGER | read-write | Input SSMs combied for both options. You should be aware of using which code when. |
| INT mbgLtNgCfgPtpSyncEOutputSsm | 1.3.6.1.4.1.5597.30.1.4.1.1.41 | INTEGER | read-write | Input SSMs combined for both options. You should be aware of using which code when. |
| INT mbgLtNgCfgPtpSyncEGbitCopperMode | 1.3.6.1.4.1.5597.30.1.4.1.1.42 | INTEGER | read-write | Gigabit copper modes |
| MEI mbgLtNgCfgPtpMiscEnable1Step | 1.3.6.1.4.1.5597.30.1.4.1.1.43 | MeinbergSwitch | read-write | Enable PTP 1 step if supported |
| MEI mbgLtNgCfgPtpDisableMgmtMsgs | 1.3.6.1.4.1.5597.30.1.4.1.1.44 | MeinbergSwitch | read-write | Disable management messages if suppported |
| INT mbgLtNgCfgPtpOutput1 | 1.3.6.1.4.1.5597.30.1.4.1.1.45 | INTEGER | read-write | Additional I/O output if suppported |
| INT mbgLtNgCfgPtpOutput2 | 1.3.6.1.4.1.5597.30.1.4.1.1.46 | INTEGER | read-write | Additional I/O output if suppported |
| INT mbgLtNgCfgPtpCmd | 1.3.6.1.4.1.5597.30.1.4.2 | INTEGER | read-write | Configuration commands |
| mbgLtNgCfgSystem | 1.3.6.1.4.1.5597.30.1.5 | |||
| mbgLtNgCfgGeneral | 1.3.6.1.4.1.5597.30.1.5.0 | |||
| INT mbgLtNgCfgWebLanguage | 1.3.6.1.4.1.5597.30.1.5.0.1 | INTEGER | read-only | set language for web interface |
| MEI mbgLtNgCfgActivateChangesAsStartup | 1.3.6.1.4.1.5597.30.1.5.0.2 | MeinbergSwitch | read-write | activate changes automatically as startup configuration |
| mbgLtNgCfgDisplay | 1.3.6.1.4.1.5597.30.1.5.1 | |||
| MEI mbgLtNgCfgEnableFrontPanelLight | 1.3.6.1.4.1.5597.30.1.5.1.1 | MeinbergSwitch | read-write | active light at front panel |
| mbgLtNgCommands | 1.3.6.1.4.1.5597.30.2 | |||
| INT mbgLtNgCmdExecute | 1.3.6.1.4.1.5597.30.2.1 | INTEGER | read-write | Send a command to the timeserver to be executed; Attention: Command should be executed with a timeout of 120 seconds and 0 retries |
| STR mbgLtNgCmdSetTime | 1.3.6.1.4.1.5597.30.2.2 | DisplayString | read-write | Reference time can be set via a date-time string in format: yyyy-mm-dd hh:mm:ss Time is interpreted as configured via web interface at menu: 'Receiver'->'Time Zone' It is mandatory to unplug the receiver's antenna to make this work. and strongly advised to execute a SNMPSET WITHOUT retries and a timeout value greater than 60 seconds. Otherwise there might come up unforeseen issues. SNMPGET always returns default value. |
| mbgLtNgTrapNotifications | 1.3.6.1.4.1.5597.30.3 | |||
| mbgLtNgTraps | 1.3.6.1.4.1.5597.30.3.0 | |||
| NTF mbgLtNgTrapNTPNotSync | 1.3.6.1.4.1.5597.30.3.0.1 | trap to be sent when NTP is not synchronised | ||
| NTF mbgLtNgTrapNTPStopped | 1.3.6.1.4.1.5597.30.3.0.2 | trap to be sent when NTP is stopped | ||
| NTF mbgLtNgTrapServerBoot | 1.3.6.1.4.1.5597.30.3.0.3 | trap to be sent when time server has finished boot sequence | ||
| NTF mbgLtNgTrapReceiverNotResponding | 1.3.6.1.4.1.5597.30.3.0.4 | trap to be sent when receiver is not responding | ||
| NTF mbgLtNgTrapReceiverNotSync | 1.3.6.1.4.1.5597.30.3.0.5 | trap to be sent when receiver is not synchronised | ||
| NTF mbgLtNgTrapAntennaFaulty | 1.3.6.1.4.1.5597.30.3.0.6 | trap to be sent when connection to antenna is broken | ||
| NTF mbgLtNgTrapAntennaReconnect | 1.3.6.1.4.1.5597.30.3.0.7 | trap to be sent when antenna has been reconnected | ||
| NTF mbgLtNgTrapConfigChanged | 1.3.6.1.4.1.5597.30.3.0.8 | trap to be sent when timeserver reloaded its configuration | ||
| NTF mbgLtNgTrapLeapSecondAnnounced | 1.3.6.1.4.1.5597.30.3.0.9 | trap to be sent when a leap second has been announced | ||
| NTF mbgLtNgTrapSHSTimeLimitError | 1.3.6.1.4.1.5597.30.3.0.10 | trap to be sent when SHS timelimit exceeded | ||
| NTF mbgLtNgTrapSecondaryRecNotSync | 1.3.6.1.4.1.5597.30.3.0.11 | trap to be sent when secondary receiver in SHS system is not synchronised | ||
| NTF mbgLtNgTrapPowerSupplyFailure | 1.3.6.1.4.1.5597.30.3.0.12 | trap to be sent when one of the redundant power supplies fails | ||
| NTF mbgLtNgTrapAntennaShortCircuit | 1.3.6.1.4.1.5597.30.3.0.13 | trap to be sent when a connected antenna fails due to a short circuit | ||
| NTF mbgLtNgTrapReceiverSync | 1.3.6.1.4.1.5597.30.3.0.14 | trap to be sent when receiver is synchronised | ||
| NTF mbgLtNgTrapNTPClientAlarm | 1.3.6.1.4.1.5597.30.3.0.15 | trap to be sent when an NTP Client Monitoring alarm occurs, e.g. when a monitored client is not reachable. | ||
| NTF mbgLtNgTrapPowerSupplyUp | 1.3.6.1.4.1.5597.30.3.0.16 | trap to be sent when a power supply returned to a healthy state. | ||
| NTF mbgLtNgTrapNetworkDown | 1.3.6.1.4.1.5597.30.3.0.17 | trap to be sent when a monitored network port is down. | ||
| NTF mbgLtNgTrapNetworkUp | 1.3.6.1.4.1.5597.30.3.0.18 | trap to be sent when a monitored network port is up. | ||
| NTF mbgLtNgTrapSecondaryRecNotResp | 1.3.6.1.4.1.5597.30.3.0.19 | trap to be sent when secondary receiver is not responding | ||
| NTF mbgLtNgTrapXmrLimitExceeded | 1.3.6.1.4.1.5597.30.3.0.30 | trap to be sent when a reference offset exceeds the configured limit | ||
| NTF mbgLtNgTrapXmrRefDisconnect | 1.3.6.1.4.1.5597.30.3.0.31 | trap to be sent when a reference signal has been lost | ||
| NTF mbgLtNgTrapXmrRefReconnect | 1.3.6.1.4.1.5597.30.3.0.32 | trap to be sent when a reference signal recovered | ||
| NTF mbgLtNgTrapFdmError | 1.3.6.1.4.1.5597.30.3.0.33 | trap to be sent when the Fdm module generates an alarm | ||
| NTF mbgLtNgTrapSHSTimeLimitWarning | 1.3.6.1.4.1.5597.30.3.0.34 | trap to be sent when SHS warning limit exceeded | ||
| NTF mbgLtNgTrapSecondaryRecSync | 1.3.6.1.4.1.5597.30.3.0.35 | trap to be sent when secondary receiver is synchronised | ||
| NTF mbgLtNgTrapNTPSync | 1.3.6.1.4.1.5597.30.3.0.36 | trap to be sent when NTP is synchronised | ||
| NTF mbgLtNgTrapPtpPortDisconnected | 1.3.6.1.4.1.5597.30.3.0.37 | trap to be sent when PTP network port got disconnected | ||
| NTF mbgLtNgTrapPtpPortConnected | 1.3.6.1.4.1.5597.30.3.0.38 | trap to be sent when PTP network port got connected | ||
| NTF mbgLtNgTrapPtpStateChanged | 1.3.6.1.4.1.5597.30.3.0.39 | trap to be sent when PTP state changed (e.g. from 'passive' to 'master') | ||
| NTF mbgLtNgTrapPtpError | 1.3.6.1.4.1.5597.30.3.0.40 | trap to be sent when PTP raised an error | ||
| NTF mbgLtNgTrapLowSystemResources | 1.3.6.1.4.1.5597.30.3.0.41 | trap to be sent when system is running on low resources | ||
| NTF mbgLtNgTrapFanDown | 1.3.6.1.4.1.5597.30.3.0.45 | trap to be sent when fan goes down | ||
| NTF mbgLtNgTrapFanUp | 1.3.6.1.4.1.5597.30.3.0.46 | trap to be sent when fan comes up | ||
| NTF mbgLtNgTrapCertificateExpired | 1.3.6.1.4.1.5597.30.3.0.47 | trap to be sent when certificate expired or will expire | ||
| NTF mbgLtNgTrapSufficientSystemResources | 1.3.6.1.4.1.5597.30.3.0.48 | trap to be sent when system has regained sufficient resources | ||
| NTF mbgLtNgTrapOscillatorWarmedUp | 1.3.6.1.4.1.5597.30.3.0.49 | trap to be sent when oscillator is not warmed up | ||
| NTF mbgLtNgTrapOscillatorNotWarmedUp | 1.3.6.1.4.1.5597.30.3.0.50 | trap to be sent when oscillator is warmed up | ||
| NTF mbgLtNgTrapXmrRefChanged | 1.3.6.1.4.1.5597.30.3.0.51 | trap to be sent when XMR reference source changed | ||
| NTF mbgLtNgTrapClusterMasterChanged | 1.3.6.1.4.1.5597.30.3.0.52 | trap to be sent when cluster mode is active and cluster changed | ||
| NTF mbgLtNgTrapClusterFalsetickerDetected | 1.3.6.1.4.1.5597.30.3.0.53 | trap to be sent when cluster mode is active and a cluster member is dectected as falseticker | ||
| NTF mbgLtNgTrapClusterFalsetickerCleared | 1.3.6.1.4.1.5597.30.3.0.54 | trap to be sent when cluster mode is active and a cluster member is no longer a falseticker | ||
| NTF mbgLtNgTrapSHSTimeLimitOk | 1.3.6.1.4.1.5597.30.3.0.55 | trap to be sent when SHS timelimit error has been acknowledged or time difference drops below warning limit. | ||
| NTF mbgLtNgTrapIMSError | 1.3.6.1.4.1.5597.30.3.0.56 | trap to be sent when an IMS module is not responsive anymore, has got temperature issues, etc. ... | ||
| NTF mbgLtNgTrapIMSOk | 1.3.6.1.4.1.5597.30.3.0.57 | trap to be sent when an IMS module returns to healthy state. | ||
| NTF mbgLtNgTrapFDMOk | 1.3.6.1.4.1.5597.30.3.0.58 | trap to be sent when an FDM module returns to healthy state. | ||
| NTF mbgLtNgTrapNTPOffsetLimitExceeded | 1.3.6.1.4.1.5597.30.3.0.59 | trap to be sent when monitoring an NTP client and its offset limit is exceeded | ||
| NTF mbgLtNgTrapNTPOffsetLimitOk | 1.3.6.1.4.1.5597.30.3.0.60 | trap to be sent when monitoring an NTP client and its offset limit is back again in a valid range | ||
| NTF mbgLtNgTrapNormalOperation | 1.3.6.1.4.1.5597.30.3.0.77 | trap to be sent when the system returned to a healthy state | ||
| NTF mbgLtNgTrapHeartbeat | 1.3.6.1.4.1.5597.30.3.0.88 | trap to be sent periodically to indicate that time server is still alive | ||
| NTF mbgLtNgTrapTestNotification | 1.3.6.1.4.1.5597.30.3.0.99 | trap to be sent when a test notification has been requested | ||
| STR mbgLtNgTrapMessage | 1.3.6.1.4.1.5597.30.3.0.100 | DisplayString | read-only | used as a payload object for all traps, holds a clear text event message |
| mbgLtNgConformance | 1.3.6.1.4.1.5597.30.90 | |||
| mbgLtNgCompliances | 1.3.6.1.4.1.5597.30.90.1 | |||
| mbgLtNgCompliance | 1.3.6.1.4.1.5597.30.90.1.1 | The compliance statement for SNMP entities which implement version 2 of the LANTIME MIB | ||
| mbgLtNgGroups | 1.3.6.1.4.1.5597.30.90.2 | |||
| mbgLtNgObjectsGroup | 1.3.6.1.4.1.5597.30.90.2.1 | The collection of objects for the LANTIME MIB | ||
| mbgLtNgTrapsGroup | 1.3.6.1.4.1.5597.30.90.2.2 | The collection of traps for the LANTIME MIB |
RFC description
Meinberg LANTIME NTP/PTP time synchronization device SNMP management information base.
Start monitoring Meinberg LANTIME NG time server appliance with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.