MBG-SNMP-LTNG-MIB :: mbgLtNgPtpPortLinkup

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › MBG-SNMP-LTNG-MIB › mbgLtNgPtpPortLinkup

mbgLtNgPtpPortLinkup

Module: MBG-SNMP-LTNG-MIB

OID (symbolic): MBG-SNMP-LTNG-MIB::mbgLtNgPtpPortLinkup

OID (numeric): 1.3.6.1.4.1.5597.30.0.3.2.1.12

Node type: OBJECT-TYPE

Type: MeinbergSwitch

Access: read-only

Description: PTP port's physical link-up

What is mbgLtNgPtpPortLinkup?

Whether the PTP port has physical link, using the Meinberg on/off switch type. If it reads off, PTP cannot work, so check the cable or switch port.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5597.30.0.3.2.1.12
snmpwalk -v2c -c public <target> MBG-SNMP-LTNG-MIB::mbgLtNgPtpPortLinkup

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.5597.30.0.3.2.1.12.1
snmpget -v2c -c public <target> MBG-SNMP-LTNG-MIB::mbgLtNgPtpPortLinkup.1

Start monitoring Meinberg LANTIME NG time server appliance with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the MBG-SNMP-LTNG-MIB::mbgLtNgPtpPortLinkup OID value, configure state conditions and alerts, and monitor any Meinberg LANTIME NG time server appliance from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.5597mbgSnmpRootMBG-SNMP-ROOT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.5597.30mbgLantimeNGMBG-SNMP-LTNG-MIB
1.3.6.1.4.1.5597.30.0mbgLantimeNGStatusMBG-SNMP-LTNG-MIB
1.3.6.1.4.1.5597.30.0.3mbgLtNgPtpMBG-SNMP-LTNG-MIB
1.3.6.1.4.1.5597.30.0.3.2mbgLtNgPtpTableMBG-SNMP-LTNG-MIB
1.3.6.1.4.1.5597.30.0.3.2.1mbgLtNgPtpTableEntryMBG-SNMP-LTNG-MIB
1.3.6.1.4.1.5597.30.0.3.2.1.12mbgLtNgPtpPortLinkupMBG-SNMP-LTNG-MIB