Juniper-TACACS-Plus-Client-MIB

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Juniper-TACACS-Plus-Client-MIB

Organization: Juniper Networks, Inc.

Last Updated: 2004-03-02

Category: Protocol: TACACS, RADIUS and AAA, Vendor: Juniper

Description: Juniper Networks MIB for managing TACACS+ client configuration and authentication server access on Juniper E-series routers.

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is Juniper-TACACS-Plus-Client-MIB?

Juniper-TACACS-Plus-Client-MIB is a Juniper Networks enterprise MIB for configuring the TACACS+ client used for centralized authentication and authorization of administrative access to JUNOSe E-series routers. It exposes global client settings (timeout, shared key, source IP, directed-request behavior) and a table of configured TACACS+ server hosts with per-host address, port, primary/backup designation, single-connection mode, timeout, and key. Its monitoring value is verifying the software/service configuration of the admin-AAA path: confirming which host is primary versus backup and whether shared keys and timeouts are correctly set helps diagnose administrative login failures, a software-availability issue rather than a hardware one. It relates conceptually to the standard TACACS+ protocol (RFC 8907) client behavior, paralleling how RADIUS client MIBs are structured, though it is a proprietary Juniper module. It is typically deployed on routers and switches using TACACS+ for admin AAA in enterprise or service-provider networks, where Juniper-TACACS-Plus-Client-MIB SNMP monitoring helps confirm the authentication path stays correctly configured.

IPNetwork Monitor allows you to monitor SNMP objects defined in Juniper-TACACS-Plus-Client-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • Juniper E-series router (JUNOSe)

Monitoring Examples

Troubleshooting failed device logins, an admin can check juniTacacsPlusClientHostConfigTable entries (juniTacacsPlusClientHostAddr, juniTacacsPlusClientHostPort, juniTacacsPlusClientHostPrimary) to verify the primary TACACS+ server is correctly configured, and compare juniTacacsPlusClientTimeout against juniTacacsPlusClientHostTimeout to see if timeouts are too aggressive for a slow link. A mismatched juniTacacsPlusClientKey or juniTacacsPlusClientHostKey between router and server would explain authentication rejections despite the host being reachable.

What Can Be Monitored

  • configured TACACS+ host addresses/ports
  • primary vs. backup server designation
  • client and per-host timeout settings
  • shared secret key configuration
  • single-connection mode setting
Imported Objects

From Juniper-MIBs

juniMibsMODULE-IDENTITY

From SNMPv2-CONF

MODULE-COMPLIANCE
OBJECT-GROUP

From SNMPv2-SMI

Counter32
IpAddress
MODULE-IDENTITY
OBJECT-TYPE

From SNMPv2-TC

RowStatus
TEXTUAL-CONVENTION
TimeStamp
TruthValue

How to Use in IPNetwork Monitor

Example using juniTacacsPlusClientHostAuthRequests OID:

Select a Juniper E-series router, JUNOSe (TACACS+ client for admin AAA) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type juniTacacsPlusClientHostAuthRequests into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. It reports the number of authentication requests sent to the host. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.
OIDs

RFC description

Manages TACACS+ client configuration and statistics for Juniper systems, including authentication server hosts and client parameters.

Start monitoring Juniper E-series router, JUNOSe (TACACS+ client for admin AAA) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download Juniper-TACACS-Plus-Client-MIB