JUNIPER-MOBILE-GATEWAY-EXAMPLE-MIB

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › JUNIPER-MOBILE-GATEWAY-EXAMPLE-MIB

Organization: Juniper Networks, Inc.

Last Updated: 2010-11-22

Category: Vendor: Juniper

Description: Provides example managed objects for the Juniper Networks Mobile Gateway platform, serving as a template for custom MIB development.

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is JUNIPER-MOBILE-GATEWAY-EXAMPLE-MIB?

JUNIPER-MOBILE-GATEWAY-EXAMPLE-MIB is an example/template MIB module shipped by Juniper for their Mobile Gateway platform, intended to illustrate how to define custom managed objects (profiles, counters, notifications) for mobile-edge services rather than represent a real production feature. It mirrors AAA-style counters (requests, accepts, rejects, challenges, timeouts, errors) plus a sample profile table and example notifications/sync stats, purely as a development template. Because it's a sample module, any "monitoring" it enables is illustrative rather than tied to real hardware/software status—it shows developers the pattern for exposing request/response counters and profile tables, not genuine fault or performance data. It is modeled on the same structure as JUNIPER-MOBILE-GATEWAY-AAA-MIB, within the Juniper enterprise Mobile Gateway MIB family. It is not typically deployed in production directly; developers instead treat the JUNIPER-MOBILE-GATEWAY-EXAMPLE-MIB reference as a coding template when building new custom Mobile Gateway MIB extensions.

IPNetwork Monitor allows you to monitor SNMP objects defined in JUNIPER-MOBILE-GATEWAY-EXAMPLE-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • Juniper Networks Mobile Gateway platform (example/template module, not a real deployed feature)

Monitoring Examples

The module defines sample counters like jnxMobileGatewayTotalRequests, jnxMobileGatewayTotalAccepts, and jnxMobileGatewayTotalRejects, plus a jnxMobileGatewayProfileTable (jnxMobileGatewayProfileEntry with jnxMobileGatewayProfileName/Description); however, since this is explicitly an example/template MIB, these objects illustrate a coding pattern rather than genuine production telemetry, so no real-world monitoring anomaly can be honestly attributed to it.

What Can Be Monitored

  • example request/accept/reject counters (template pattern)
  • example profile table entries
  • example notification/sync statistics
Imported Objects

From INET-ADDRESS-MIB

InetAddress
InetAddressPrefixLength
InetAddressType
InetPortNumber

From IPV6-TC

Ipv6Address
Ipv6AddressIfIdentifier
Ipv6AddressPrefix

From JUNIPER-EXPERIMENT-MIB

jnxExampleMibRootOBJECT-IDENTITY

From JUNIPER-MIMSTP-MIB

EnabledStatus

From SNMPv2-SMI

Counter32
Counter64
Integer32
IpAddress
MODULE-IDENTITY
NOTIFICATION-TYPE
OBJECT-TYPE
Unsigned32

From SNMPv2-TC

DisplayString
RowStatus
TEXTUAL-CONVENTION
TruthValue

How to Use in IPNetwork Monitor

Example using jnxMobileGatewayTotalRequests OID:

Select a Juniper Networks Mobile Gateway platform (example/template module) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type jnxMobileGatewayTotalRequests into the Find box to locate it in the OID tree, then select it and click OK. It reports the total requests made. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter64-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.
OIDs

RFC description

Sample objects for Mobile-Edge Services and gateway test profiles on Juniper platforms.

Start monitoring Juniper Networks Mobile Gateway platform (example/template module) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download JUNIPER-MOBILE-GATEWAY-EXAMPLE-MIB