ISNS-MGMT-MIB :: isnsDdMemberIscsiName

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › ISNS-MGMT-MIB › isnsDdMemberIscsiName

isnsDdMemberIscsiName

Module: ISNS-MGMT-MIB

OID (symbolic): ISNS-MGMT-MIB::isnsDdMemberIscsiName

OID (numeric): 1.3.6.1.2.1.10.4371.1.1.6.2.1.2

Node type: OBJECT-TYPE

Type: SnmpAdminString

Access: read-only

Description: The iSCSI Name associated with the storage node. The iSCSI Name can not be longer then 223 bytes. The iSNS server internal maximum size is 224 bytes to provide NULL termination. This is the iSCSI Name for the storage node that is a member of the DD. This value maps 1 to 1 to the isnsDdMemberIscsiIdx node index. The iSCSI Name field is too long to be easily used for an index directly. The node index used for a specific node name is only persistent across iSNS Server reinitializations for nodes that are in a Discovery Domain (DD) or are registered control nodes. This value is only required during row creation if the storage node is not yet registered in the iSNS Server instance. If the storage node is not yet registered, then the iSCSI Name MUST be provided with the iSCSI node index during row creation in order to create the 1 to 1 mapping.

What is isnsDdMemberIscsiName?

The iSCSI Name of a storage node that is a member of this Discovery Domain, mapped 1:1 to isnsDdMemberIscsiIdx; required at row creation if the node isn't already registered in the iSNS server. Admins provide this name when manually adding an iSCSI initiator or target to a DD via SNMP.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.2.1.10.4371.1.1.6.2.1.2
snmpwalk -v2c -c public <target> ISNS-MGMT-MIB::isnsDdMemberIscsiName

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.2.1.10.4371.1.1.6.2.1.2.1
snmpget -v2c -c public <target> ISNS-MGMT-MIB::isnsDdMemberIscsiName.1

Start monitoring Vendor-neutral IETF standard (iSNS server in an iSCSI/Fibre Channel SAN) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ISNS-MGMT-MIB::isnsDdMemberIscsiName OID value, configure state conditions and alerts, and monitor any Vendor-neutral IETF standard (iSNS server in an iSCSI/Fibre Channel SAN) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.2mgmtAPERTUS-NPG-MIB
1.3.6.1.2.1mib_2AXON-MIB
1.3.6.1.2.1.10transmissionCHECKPOINT-MIB-2
Numeric OIDNameModule
1.3.6.1.2.1.10.4371isnsMgmtMIBISNS-MGMT-MIB
1.3.6.1.2.1.10.4371.1isnsObjISNS-MGMT-MIB
1.3.6.1.2.1.10.4371.1.1isnsSrvrInfoISNS-MGMT-MIB
1.3.6.1.2.1.10.4371.1.1.6isnsDdInfoISNS-MGMT-MIB
1.3.6.1.2.1.10.4371.1.1.6.2isnsDdIscsiMemberTableISNS-MGMT-MIB
1.3.6.1.2.1.10.4371.1.1.6.2.1isnsDdIscsiMemberEntryISNS-MGMT-MIB
1.3.6.1.2.1.10.4371.1.1.6.2.1.2isnsDdMemberIscsiNameISNS-MGMT-MIB