All MIBs › IBM-SYSTEM-RAID-MIB
Category: Domain: Server Hardware, Domain: Storage, Vendor: IBM
Description: IBM MIB for RAID array configuration and status monitoring including logical drive, physical disk, and controller health.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is IBM-SYSTEM-RAID-MIB?
IBM-SYSTEM-RAID-MIB is an IBM vendor-specific MIB, derived from CIM classes (IBMPSG_RAIDController, IBMPSG_RAIDDiskDrive, referenced directly in each object's REFERENCE clause), that models RAID controller and physical disk configuration and status on IBM systems. It exposes ibmSystemRaidControllerTable with controller identity and firmware details (ibmSystemRaidControllerModel, ibmSystemRaidControllerBIOSVersion, ibmSystemRaidControllerFirmwareVersion, ibmSystemRaidControllerDriverVersion, ibmSystemRaidControllerSlot, ibmSystemRaidControllerStatus) and ibmSystemRaidDiskDriveTable with per-disk placement and health (ibmSystemRaidDiskDriveChannelID, ibmSystemRaidDiskDriveFirmware, ibmSystemRaidDiskDriveState, a numeric enumeration covering Standby, Defunct Hot Spare, Ready, Hot Spare, Online, Rebuild, and Reserved states, and ibmSystemRaidDiskDriveStatus). It also defines ibmSystemRaidTrap and ibmSystemRaidTrapInfo subtrees for RAID-related notifications. This data is useful for monitoring storage-array health, controller firmware consistency and disk-level failure or rebuild states, before a degraded array leads to data loss. It depends on IBM-SYSTEM-MIB for its base numeric/string types (Uint8, Uint16, String, etc.) and enterprise registration, and administrators can download the IBM-SYSTEM-RAID-MIB file for server hardware monitoring on IBM System x platforms with ServeRAID controllers.
IPNetwork Monitor allows you to monitor SNMP objects defined in IBM-SYSTEM-RAID-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- IBM System x / xSeries servers with ServeRAID controllers
Monitoring Examples
An operator polls ibmSystemRaidDiskDriveState across ibmSystemRaidDiskDriveTable for each disk attached to a given controller; a drive reporting state 139 (Rebuild) or 8 (Defunct Disk Drive) instead of 137 (Online) would indicate a failed or actively-rebuilding disk that reduces the array's redundancy until it completes or is replaced.
What Can Be Monitored
- RAID controller model/firmware/BIOS/driver versions
- controller slot and status
- physical disk drive state (online, rebuild, defunct, hot spare)
- disk drive channel and firmware revision
- RAID trap/notification objects
This MIB depends on
Related MIBs
Imported Objects
From IBM-SYSTEM-MIB
| Boolean | |
| Datetime | |
| Real32 | |
| Real64 | |
| Sint16 | |
| Sint32 | |
| Sint64 | |
| Sint8 | |
| String | |
| Uint16 | |
| Uint32 | |
| Uint64 | |
| Uint8 | |
| ibmSystemRaid | OBJECT-IDENTITY |
From RFC-1212
| OBJECT-TYPE |
From RFC-1215
| TRAP-TYPE |
From SNMP-FRAMEWORK-MIB
| SnmpAdminString |
From SNMPv2-TC
| DateAndTime | |
| TruthValue |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| ibmSystemRaidTrap | 1.3.6.1.4.1.2.6.159.1.1.200.1 | |||
| NTF ibmSystemRaidNoControllers | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.201 | Informational: No controllers were found in this system. | ||
| NTF ibmSystemRaidControllerFail | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.202 | Error: Commands not responding on Controller %d. | ||
| NTF ibmSystemRaidDeadBattery | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.203 | Error: The battery-backup cache device on Controller %d needs a new battery. | ||
| NTF ibmSystemRaidDeadBatteryCache | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.204 | Error: The battery-backup cache device on Controller %d is defective %d | ||
| NTF ibmSystemRaidPollingFail | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.205 | Error: Background polling commands not responding on Controller %d %d | ||
| NTF ibmSystemRaidConfigFail | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.206 | Error: Cannot read controller configuration. | ||
| NTF ibmSystemRaidControllerAdded | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.207 | Informational: Controller %d has been added to the system. | ||
| NTF ibmSystemRaidControllerReplaced | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.208 | Informational: Controller %d has been replaced in the system. | ||
| NTF ibmSystemRaidControllerFailover | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.209 | Informational: Controller %d failover detected. Passive controller is now active. | ||
| NTF ibmSystemRaidControllerVersionMismatch | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.210 | Warning: Controller %d version mismatch detected. The BIOS, Firmware, and Driver are not a matched set and are not compatible. | ||
| NTF ibmSystemRaidControllerBatteryOvertemp | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.211 | Warning: Controller %d battery has exceeded normal operating temperature. | ||
| NTF ibmSystemRAIDControllerBadStripes | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.215 | Warning: One or more logical drives contain a bad stripe: Controller %d. | ||
| NTF ibmSystemRaidControllerBatteryTempNormal | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.216 | Informational: Controller %d battery operating temperature is normal. | ||
| NTF ibmSystemRaidControllerStatusChange | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.217 | The status of the controller changed | ||
| NTF ibmSystemRaidLogicalDriveCritical | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.301 | Warning: Logical Drive %d is Critical on Controller %d. | ||
| NTF ibmSystemRaidLogicalDriveBlocked | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.302 | Error: Logical Drive %d is Blocked on Controller %d. | ||
| NTF ibmSystemRaidLogicalDriveOffLine | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.303 | Error: Logical Drive %d is Offline on Controller %d. | ||
| NTF ibmSystemRaidRebuildDetected | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.304 | Informational: Rebuilding Logical Drive %d on Controller %d. | ||
| NTF ibmSystemRaidRebuildComplete | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.305 | Informational: Rebuild complete on Logical Drive %d of Controller %d. | ||
| NTF ibmSystemRaidRebuildFail | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.306 | Error: Rebuild failed on Logical Drive %d of Controller %d %d. | ||
| NTF ibmSystemRaidSyncDetected | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.307 | Informational: Synchronizing Logical Drive %d on Controller %d. | ||
| NTF ibmSystemRaidSyncComplete | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.308 | Informational: Synchronization complete on Logical Drive %d of Controller %d. | ||
| NTF ibmSystemRaidSyncFail | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.309 | Error: Synchronization failed on Logical Drive %d of Controller %d %d. | ||
| NTF ibmSystemRaidMigrationDetected | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.310 | Informational: Migrating Logical Drive %d on Controller %d. | ||
| NTF ibmSystemRaidMigrationComplete | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.311 | Informational: Migration complete on Logical Drive %d of Controller %d. | ||
| NTF ibmSystemRaidMigrationFail | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.312 | Error: Migration failed on Logical Drive %d of Controller %d %d. | ||
| NTF ibmSystemRaidCompressionDetected | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.313 | Informational: Compressing Logical Drive %d on Controller %d. | ||
| NTF ibmSystemRaidCompressionComplete | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.314 | Informational: Compression complete on Logical Drive %d of Controller %d. | ||
| NTF ibmSystemRaidcompressionFail | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.315 | Error: Compression failed on Logical Drive %d of Controller %d %d. | ||
| NTF ibmSystemRaidDecompressionDetected | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.316 | Informational: Decompressing Logical Drive %d on Controller %d. | ||
| NTF ibmSystemRaidDecompressionComplete | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.317 | Informational: Decompression complete on Logical Drive %d of Controller %d. | ||
| NTF ibmSystemRaidDecompressionFail | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.318 | Error: Decompression failed on Logical Drive %d of Controller %d %d. | ||
| NTF ibmSystemRaidFlashCopyDetected | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.319 | Informational: FlashCopying Logical Drive %d on Controller %d. | ||
| NTF ibmSystemRaidFlashCopyComplete | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.320 | Informational: FlashCopy complete on Logical Drive %d of Controller %d. | ||
| NTF ibmSystemRaidFlashCopyFail | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.321 | Error: FlashCopy failed on Logical Drive %d of Controller %d %d. | ||
| NTF ibmSystemRaidArrayRebuildDetected | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.322 | Informational: Rebuilding Array %d on Controller %d. | ||
| NTF ibmSystemRaidArrayRebuildComplete | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.323 | Informational: Rebuild complete on Array %d of Controller %d. | ||
| NTF ibmSystemRaidArrayRebuildFail | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.324 | Error: Rebuild failed on Array %d of Controller %d %d. | ||
| NTF ibmSystemRaidArraySyncDetected | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.325 | Informational: Synchronizing Array %d on Controller %d. | ||
| NTF ibmSystemRaidArraySyncComplete | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.326 | Informational: Synchronization complete on Array %d of Controller %d. | ||
| NTF ibmSystemRaidArraySyncFail | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.327 | Error: Synchronization failed on Array %d of Controller %d %d. | ||
| NTF ibmSystemRaidArrayFlashCopyDetected | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.328 | Informational: FlashCopying Array %d on Controller %d. | ||
| NTF ibmSystemRaidArrayFlashCopyComplete | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.329 | Informational: FlashCopy complete on Array %d of Controller %d. | ||
| NTF ibmSystemRaidArrayFlashCopyFail | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.330 | Error: FlashCopy failed on Array %d of Controller %d %d. | ||
| NTF ibmSystemRaidLogicalDriveUnblocked | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.331 | Informational: Logical Drive %d is unblocked on Controller %d. | ||
| NTF ibmSystemRaidCompactionDetected | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.332 | Informational: Compacting Logical Drive %d on Controller %d. | ||
| NTF ibmSystemRaidCompactionComplete | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.333 | Informational: Compaction complete on Logical Drive %d of Controller %d. | ||
| NTF ibmSystemRaidCompactionFail | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.334 | Error: Compaction failed on Logical Drive %d of Controller %d %d. | ||
| NTF ibmSystemRaidExpansionDetected | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.335 | Informational: Expanding Logical Drive %d on Controller %d. | ||
| NTF ibmSystemRaidExpansionComplete | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.336 | Informational: Expansion complete on Logical Drive %d of Controller %d. | ||
| NTF ibmSystemRaidExpansionFail | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.337 | Error: Expansion failed on Logical Drive %d of Controller %d %d. | ||
| NTF ibmSystemRaidLogicalDriveCriticalPeriodic | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.338 | Warning: Periodic scan found 1 or more critical logical drives on Controller %d. | ||
| NTF ibmSystemRaidCopyBackDetected | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.339 | Informational: Copy back in progress on Logical Drive %d on Controller %d. | ||
| NTF ibmSystemRaidCopyBackComplete | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.340 | Informational: Copy back complete on Logical Drive %d of Controller %d. | ||
| NTF ibmSystemRaidCopyBackFail | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.341 | Error: Copy back failed on Logical Drive %d of Controller %d %d. | ||
| NTF ibmSystemRaidInitDetected | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.342 | Informational: Initialization in progress on Logical Drive %d on Controller %d. | ||
| NTF ibmSystemRaidInitComplete | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.343 | Informational: Initialization complete on Logical Drive %d of Controller %d. | ||
| NTF ibmSystemRaidInitFail | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.344 | Error: Initialization failed on Logical Drive %d of Controller %d %d. | ||
| NTF ibmSystemRAIDLogicalDriveOK | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.345 | Informational: Logical Drive %d of Controller %d is normal. | ||
| NTF ibmSystemRAIDLogicalDriveAdded | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.346 | Informational: Added Logical Drive %d of Controller %d. | ||
| NTF ibmSystemRAIDLogicalDriveRemoved | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.347 | Informational: Removed Logical Drive %d of Controller %d. | ||
| NTF ibmSystemRaidArrayFlashCopyStopped | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.348 | The flashcopy operation has stopped | ||
| NTF ibmSystemRaidArrayRebuildStopped | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.349 | The array rebuild operation has stopped | ||
| NTF ibmSystemRaidArrayStatusChange | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.350 | The array status has changed | ||
| NTF ibmSystemRaidArraySyncStopped | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.351 | The array synchronization operation has stopped | ||
| NTF ibmSystemRaidCompactionStopped | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.352 | The compaction operation has stopped | ||
| NTF ibmSystemRaidCompressionStopped | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.353 | The compression operation has stopped | ||
| NTF ibmSystemRaidCopybackStopped | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.354 | The copyback operation has stopped | ||
| NTF ibmSystemRaidDecompressionStopped | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.355 | The decompression operation has stopped | ||
| NTF ibmSystemRaidExpansionStopped | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.356 | The expansion operation has stopped | ||
| NTF ibmSystemRaidFlashCopyStopped | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.357 | The flashcopy operation has stopped | ||
| NTF ibmSystemRaidInitStopped | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.358 | The initialiation operation has stopped | ||
| NTF ibmSystemRaidLogicalDriveStatusChange | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.359 | The status of the locaical drive has changed | ||
| NTF ibmSystemRaidMigrationStopped | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.360 | The migration operation has stopped | ||
| NTF ibmSystemRaidRebuildStopped | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.361 | The rebuild operation has stopped | ||
| NTF ibmSystemRaidSyncStopped | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.362 | The synchroniation operation has stopped | ||
| NTF ibmSystemRaidDefunctDrive | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.401 | Error: Defunct drive on Controller %d, Channel %d, Device ID %d. | ||
| NTF ibmSystemRaidPfaDrive | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.402 | Warning: PFA drive on Controller %d, Channel %d, Device ID %d. | ||
| NTF ibmSystemRaidDefunctReplaced | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.403 | Informational: A drive is set to Hot-Spare on Controller %d, Channel %d, Device ID %d. | ||
| NTF ibmSystemRaidDefunctDriveFru | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.404 | Error: Defunct drive (FRU Part # %d} on controller %d, channel %d, Device ID %d. | ||
| NTF ibmSystemRaidPfaDriveFru | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.405 | Warning: PFA drive (FRU Part # %d) on Controller %d, Channel %d, Device ID %d. | ||
| NTF ibmSystemRaidUnsupportedDrive | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.406 | Warning: Unsupported physical drive found on Controller %d, Channel %d, Device ID %d. | ||
| NTF ibmSystemRaidDriveAdded | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.407 | Informational: Drive added on Controller %d, Channel %d, Device ID %d. | ||
| NTF ibmSystemRaidDriveRemoved | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.408 | Informational: Drive removed on Controller %d, Channel %d, Device ID %d. | ||
| NTF ibmSystemRaidDriveClearDetected | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.409 | Informational: Clear in progress on Controller %d, Channel %d, Device ID %d. | ||
| NTF ibmSystemRaidDriveClearComplete | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.410 | Informational: Clear complete on Controller %d, Channel %d, Device ID %d. | ||
| NTF ibmSystemRaidDriveClearFail | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.411 | Error: Clear failed on Controller %d, Channel %d, Device ID %d. | ||
| NTF ibmSystemRaidDriveSyncDetected | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.412 | Informational: Synchronization in progress on Controller %d, Channel %d, Device ID %d. | ||
| NTF ibmSystemRaidDriveSyncComplete | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.413 | Informational: Synchronization complete on Controller %d, Channel %d, Device ID %d. | ||
| NTF ibmSystemRaidDriveSyncFail | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.414 | Error: Synchronization failed on Controller %d, Channel %d, Device ID %d. | ||
| NTF ibmSystemRaidDriveVerifyDetected | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.415 | Informational: Verify in progress on Controller %d, Channel %d, Device ID %d. | ||
| NTF ibmSystemRaidDriveVerifyComplete | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.416 | Informational: Verify complete on Controller %d, Channel %d, Device ID %d. | ||
| NTF ibmSystemRaidDriveVerifyFail | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.417 | Error: Verify failed on Controller %d, Channel %d, Device ID %d. | ||
| NTF ibmSystemRaidDriveClearStopped | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.418 | The drive clear operation has stopped | ||
| NTF ibmSystemRaidDriveSecureEraseStopped | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.419 | The secure erase operation has stopped | ||
| NTF ibmSystemRaidDriveStatusChange | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.420 | The drive status has changed | ||
| NTF ibmSystemRaidDriveSyncStopped | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.421 | The sychronization operation has stopped | ||
| NTF ibmSystemRaidDriveVerifyStopped | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.422 | The verify operation has stopped | ||
| NTF ibmSystemRaidSpareCreated | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.423 | ibmSystemRaidSpareCreated | ||
| NTF ibmSystemRaidSpareDeleted | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.424 | ibmSystemRaidSpareDeleted | ||
| NTF ibmSystemRaidEnclosureOK | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.501 | Informational: Enclosure device responding on Controller %d, Channel %d. | ||
| NTF ibmSystemRaidEnclosureFail | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.502 | Error: Enclosure device not responding on Controller %d, Channel %d. | ||
| NTF ibmSystemRaidFanOk | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.503 | Informational: Enclosure fan %d on Controller %d, Channel %d is now operational. | ||
| NTF ibmSystemRaidFanFail | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.504 | Error: Enclosure fan %d on Controller %d, Channel %d is malfunctioning. | ||
| NTF ibmSystemRaidFanInstalled | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.505 | Informational: Enclosure fan %d on Controller %d, Channel %d has been installed. | ||
| NTF ibmSystemRaidFanRemoved | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.506 | Warning: Enclosure fan %d on Controller %d, Channel %d has been removed. | ||
| NTF ibmSystemRaidTempOk | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.507 | Error: Enclosure temperature is in normal range on Controller %d, Channel %d. | ||
| NTF ibmSystemRaidTempFail | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.508 | Error: Enclosure temperature is out of normal range on Controller %d, Channel %d. | ||
| NTF ibmSystemRaidPowerSupplyOk | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.509 | Informational: Enclosure power supply %d on Controller %d, Channel %d is now operational. | ||
| NTF ibmSystemRaidPowerSupplyFail | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.510 | Error: Enclosure power supply %d on Controller %d, Channel %d is malfunctioning. | ||
| NTF ibmSystemRaidPowerSupplyInstalled | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.511 | Informational: Enclosure power supply %d on Controller %d, Channel %d has been installed. | ||
| NTF ibmSystemRaidPowerSupplyRemoved | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.512 | Warning: Enclosure power supply %d on Controller %d, Channel %d has been removed. | ||
| NTF ibmSystemRaidTestTrap | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.601 | Informational: This is a test trap. | ||
| NTF ibmSystemRaidLsiPDFail | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.1000 | A physical drive has failed in a RAID configuration | ||
| NTF ibmSystemRaidLsiPDPartOfLDFail | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.1003 | A physical drive has failed in a logical drive | ||
| NTF ibmSystemRaidLsiPDPartOfLDAdd | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.1004 | A drive has been added to a RAID configuration | ||
| NTF ibmSystemRaidLsiHSPartOfLD | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.1005 | ibmSystemRaidLsiHSPartOfLD | ||
| NTF ibmSystemRaidLsiHSFail | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.1007 | A hot spare drive has failed in a RAID configuration | ||
| NTF ibmSystemRaidLsiPDHS | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.1008 | A physical drive has been made a hot spare in the RAID configuration | ||
| NTF ibmSystemRaidLsiLDOffline | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.1009 | A logical drive is in the offline state | ||
| NTF ibmSystemRaidLsiLDDegraded | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.1011 | A logical drive has been degraded in a RAID configuration | ||
| NTF ibmSystemRaidLsiLDOptimal | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.1012 | A logical drive is functioning correctly | ||
| NTF ibmSystemRaidLsiSMARTError | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.1013 | A PFA has been detected on a drive in the RAID configuration | ||
| NTF ibmSystemRaidLsiRbldStart | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.1015 | A RAID rebuild operation is in progress on an array in the RAID configuration | ||
| NTF ibmSystemRaidLsiRbldComplete | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.1016 | A RAID rebuild operation has completed on an array in the RAID configuration | ||
| NTF ibmSystemRaidLsiRbldFail | 1.3.6.1.4.1.2.6.159.1.1.200.1.0.1017 | A RAID rebuild operation has failed on an array in the RAID configuration | ||
| ibmSystemRaidControllerTable | 1.3.6.1.4.1.2.6.159.1.1.200.2 | not-accessible | The IBMPSG_RAIDController class represents a RAID Controller | |
| ibmSystemRaidControllerEntry | 1.3.6.1.4.1.2.6.159.1.1.200.2.1 | not-accessible | This class defines an entry for each IBMPSG_RAIDController instance. Each instance of the IBMPSG_RAIDController class contains status and descriptive information for each disk recognized by the Director SMART provider. | |
| STR ibmSystemRaidControllerKeyIndex | 1.3.6.1.4.1.2.6.159.1.1.200.2.1.1 | String | read-only | The RAID controller table index number (controller1, controller2, etc.) |
| STR ibmSystemRaidControllerControllerID | 1.3.6.1.4.1.2.6.159.1.1.200.2.1.2 | String | read-only | The DeviceID that identifies the disk |
| STR ibmSystemRaidControllerModel | 1.3.6.1.4.1.2.6.159.1.1.200.2.1.3 | String | read-only | The model of the controller |
| STR ibmSystemRaidControllerBIOSVersion | 1.3.6.1.4.1.2.6.159.1.1.200.2.1.4 | String | read-only | The version of the controllers BIOS |
| STR ibmSystemRaidControllerFirmwareVersion | 1.3.6.1.4.1.2.6.159.1.1.200.2.1.5 | String | read-only | The version of the controllers firmwar |
| STR ibmSystemRaidControllerDriverVersion | 1.3.6.1.4.1.2.6.159.1.1.200.2.1.6 | String | read-only | The version of the controllers device driver |
| STR ibmSystemRaidControllerManufacturer | 1.3.6.1.4.1.2.6.159.1.1.200.2.1.7 | String | read-only | the manufacturer of the controller |
| NUM ibmSystemRaidControllerSlot | 1.3.6.1.4.1.2.6.159.1.1.200.2.1.8 | Uint16 | read-only | The slot number the controller resides in |
| STR ibmSystemRaidControllerFRU | 1.3.6.1.4.1.2.6.159.1.1.200.2.1.9 | String | read-only | The FRU number of the controller |
| STR ibmSystemRaidControllerSerialNumber | 1.3.6.1.4.1.2.6.159.1.1.200.2.1.10 | String | read-only | The controllers serial number |
| STR ibmSystemRaidControllerInitiatorIDs | 1.3.6.1.4.1.2.6.159.1.1.200.2.1.11 | String | read-only | Specifies the controllers initiator IDs using a comma as the delimiter |
| STR ibmSystemRaidControllerStatus | 1.3.6.1.4.1.2.6.159.1.1.200.2.1.12 | String | read-only | The current status of the controller |
| ibmSystemRaidDiskDriveTable | 1.3.6.1.4.1.2.6.159.1.1.200.3 | not-accessible | The IBMPSG_RAIDDiskDrive class represents a RAID physical disk | |
| ibmSystemRaidDiskDriveEntry | 1.3.6.1.4.1.2.6.159.1.1.200.3.1 | not-accessible | This class defines an entry for each IBMPSG_RAIDDiskDrive instance. Each instance of the IBMPSG_RAIDDiskDrive class contains status and descriptive information for each disk attached to the RAID controller. | |
| STR ibmSystemRaidDiskDriveKeyIndex | 1.3.6.1.4.1.2.6.159.1.1.200.3.1.1 | String | read-only | The Physical Disk Drive table index number (Disk Drive 0, Disk Drive 1, etc.) |
| STR ibmSystemRaidDiskDriveDeviceID | 1.3.6.1.4.1.2.6.159.1.1.200.3.1.2 | String | read-only | The device ID of the drive |
| STR ibmSystemRaidDiskDriveDiskDriveID | 1.3.6.1.4.1.2.6.159.1.1.200.3.1.3 | String | read-only | The target ID of the disk drive |
| STR ibmSystemRaidDiskDriveControllerID | 1.3.6.1.4.1.2.6.159.1.1.200.3.1.4 | String | read-only | The ID of the controller it is attached to |
| STR ibmSystemRaidDiskDriveChannelID | 1.3.6.1.4.1.2.6.159.1.1.200.3.1.5 | String | read-only | The channel on the controller the drive is attached to |
| STR ibmSystemRaidDiskDriveFirmware | 1.3.6.1.4.1.2.6.159.1.1.200.3.1.6 | String | read-only | The firmware revision of the drive |
| NUM ibmSystemRaidDiskDriveState | 1.3.6.1.4.1.2.6.159.1.1.200.3.1.7 | Uint16 | read-only | The current state of the physical drive. 0=Empty, 1=Standby, 4=Defunct Hot Spare, 5=Standby Hot Spare, 8=Defunct Disk Drive, 129=Ready, 133=Hot Spare, 137=Online, 139=Rebuild, 254=Reserved |
| STR ibmSystemRaidDiskDriveStatus | 1.3.6.1.4.1.2.6.159.1.1.200.3.1.8 | String | read-only | The status of the drive |
| ibmSystemRaidLogicalDriveTable | 1.3.6.1.4.1.2.6.159.1.1.200.4 | not-accessible | The IBMPSG_RAIDLogicalDrive class represents a RAID Logical disk (Logical Drive 0, Logical Drive 1, etc.) | |
| ibmSystemRaidLogicalDriveEntry | 1.3.6.1.4.1.2.6.159.1.1.200.4.1 | not-accessible | This class defines an entry for each IBMPSG_RAIDLogicalDrive instance. Each instance of the IBMPSG_RAIDLogicalDrive class contains status and descriptive information for each RAID Logical disk. | |
| STR ibmSystemRaidLogicalDriveKeyIndex | 1.3.6.1.4.1.2.6.159.1.1.200.4.1.1 | String | read-only | The Logical Disk Drive table index number (Logical Drive 0, Logical Drive 1, etc.) |
| STR ibmSystemRaidLogicalDriveLogicalDriveID | 1.3.6.1.4.1.2.6.159.1.1.200.4.1.2 | String | read-only | The ID of the logical drive |
| STR ibmSystemRaidLogicalDriveControllerID | 1.3.6.1.4.1.2.6.159.1.1.200.4.1.3 | String | read-only | The ID of the controller the logical drive belongs to |
| STR ibmSystemRaidLogicalDriveArrayID | 1.3.6.1.4.1.2.6.159.1.1.200.4.1.4 | String | read-only | The ID of the array that the logical drive belongs to |
| STR ibmSystemRaidLogicalDriveRAIDLevel | 1.3.6.1.4.1.2.6.159.1.1.200.4.1.5 | String | read-only | The RAID level of the logical drive (RAID 1, RAID 5, etc.) |
| NUM ibmSystemRaidLogicalDriveDataSpace | 1.3.6.1.4.1.2.6.159.1.1.200.4.1.6 | Uint64 | read-only | Size of the logical drive in megabytes |
| NUM ibmSystemRaidLogicalDriveParitySpace | 1.3.6.1.4.1.2.6.159.1.1.200.4.1.7 | Uint64 | read-only | Parity space of the logical drive in megabytes |
| BOO ibmSystemRaidLogicalDriveIsBlocked | 1.3.6.1.4.1.2.6.159.1.1.200.4.1.8 | Boolean | read-only | The logical drive is in a blocked state |
| NUM ibmSystemRaidLogicalDriveState | 1.3.6.1.4.1.2.6.159.1.1.200.4.1.9 | Uint16 | read-only | The current state of the logical drive. 0=Free, 2=Offline, 3=Okay, 4=Critical, 5=Logical Drive Migration, 6=System, 20=Critical Logical Drive Migration, 36=Critical System |
| STR ibmSystemRaidLogicalDriveStatus | 1.3.6.1.4.1.2.6.159.1.1.200.4.1.10 | String | read-only | The status of the logical drive |
| ibmSystemRaidTrapInfo | 1.3.6.1.4.1.2.6.159.1.1.200.5 | |||
| STR ibmSystemRaidTrapProviderName | 1.3.6.1.4.1.2.6.159.1.1.200.5.1 | String | not-accessible | The CIM Provider Name |
| STR ibmSystemRaidTrapEventID | 1.3.6.1.4.1.2.6.159.1.1.200.5.2 | String | not-accessible | Event ID |
| INT ibmSystemRaidTrapPerceivedSeverity | 1.3.6.1.4.1.2.6.159.1.1.200.5.3 | INTEGER | not-accessible | Severity of the event 0=Normal / OK 1=Warning 2=Critical |
| STR ibmSystemRaidDescription | 1.3.6.1.4.1.2.6.159.1.1.200.5.4 | String | not-accessible | The event message |
| STR ibmSystemRaidTrapEventTime | 1.3.6.1.4.1.2.6.159.1.1.200.5.5 | String | not-accessible | Time that the event occured |
RFC description
IBM vendor MIB for monitoring and managing RAID subsystems, logical volumes, and storage arrays in IBM System storage products.
Start monitoring IBM System x/xSeries server with ServeRAID controller (CIM-based RAID/disk status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.