All MIBs › IBM-Director-Alert-MIB
Organization: IBM Corp.
Last Updated: 2004-04-21
Category: Alarm and Event Management, Domain: Server Hardware, Vendor: IBM
Description: IBM Director MIB defining alert and event notifications forwarded from IBM systems through the IBM Director management framework.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is IBM-Director-Alert-MIB?
IBM-Director-Alert-MIB is an IBM proprietary MIB (enterprise OID 2) supporting the Event Action Plan Builder in IBM Director, a systems-management console. Its objects define alert-category notifications — general events, online/offline/create/change/destroy lifecycle events, process monitoring, CPU utilization, process count, drive space used/remaining/percentage, drive workload, locked memory, memory usage, privileged-time percentage, file read operations per second, UDP/IP packets sent/received per second, IP error-packet rate, and TCP connection count — each carrying an actual-value and duration. As a notification MIB it lets IBM Director forward threshold-based resource alerts (e.g., low disk space, high CPU) as SNMP traps to an external management system. It is deployed on systems managed by IBM Director. Engineers can download the IBM-Director-Alert-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in IBM-Director-Alert-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Systems managed by IBM Director
Monitoring Examples
An external NMS subscribes to driveSpaceRemaining alerts forwarded by IBM Director's Event Action Plan Builder to catch a managed server running low on disk space.
What Can Be Monitored
- resource-threshold alert notifications (CPU, memory, disk, network)
This MIB depends on
Related MIBs
Imported Objects
From RFC1155-SMI
| enterprises |
From SNMP-FRAMEWORK-MIB
| SnmpAdminString |
From SNMPv2-CONF
| MODULE-COMPLIANCE | |
| NOTIFICATION-GROUP | |
| OBJECT-GROUP |
From SNMPv2-SMI
| Integer32 | |
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-TYPE |
From SNMPv2-TC
| DisplayString | |
| TruthValue |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| ibm | 1.3.6.1.4.1.2 | |||
| ibmProd | 1.3.6.1.4.1.2.6 | |||
| director | 1.3.6.1.4.1.2.6.159 | |||
| directorTraps | 1.3.6.1.4.1.2.6.159.201 | This MIB is for use with the Event Action Plan Builder of IBM Director. | ||
| directorFamily | 1.3.6.1.4.1.2.6.159.201.1 | |||
| topology | 1.3.6.1.4.1.2.6.159.201.1.1 | |||
| NTF online | 1.3.6.1.4.1.2.6.159.201.1.1.1 | The managed object's state has changed to online. | ||
| NTF offline | 1.3.6.1.4.1.2.6.159.201.1.1.2 | The managed object's state has changed to offline. | ||
| NTF create | 1.3.6.1.4.1.2.6.159.201.1.1.3 | The managed object has been created. | ||
| NTF change | 1.3.6.1.4.1.2.6.159.201.1.1.4 | The managed object has changed. | ||
| NTF destroy | 1.3.6.1.4.1.2.6.159.201.1.1.5 | The managed object has been destroyed. | ||
| directorAgent | 1.3.6.1.4.1.2.6.159.201.1.2 | |||
| NTF processMonitor | 1.3.6.1.4.1.2.6.159.201.1.2.1 | The process monitor threshold has generated an event. | ||
| cpuMonitors | 1.3.6.1.4.1.2.6.159.201.1.2.2 | |||
| NTF cpuUtilization | 1.3.6.1.4.1.2.6.159.201.1.2.2.1 | The CPU utilization monitor threshold has generated an event. | ||
| NTF processCount | 1.3.6.1.4.1.2.6.159.201.1.2.2.2 | The process count monitor threshold has generated an event. | ||
| diskMonitors | 1.3.6.1.4.1.2.6.159.201.1.2.3 | |||
| NTF driveSpaceUsed | 1.3.6.1.4.1.2.6.159.201.1.2.3.1 | The drive space used monitor threshold has generated an event. | ||
| NTF driveSpaceUsedPercent | 1.3.6.1.4.1.2.6.159.201.1.2.3.2 | The percentage of drive space used monitor threshold has generated an event. | ||
| NTF driveSpaceRemaining | 1.3.6.1.4.1.2.6.159.201.1.2.3.3 | The drive space remaining monitor threshold has generated an event. | ||
| NTF driveWorkload | 1.3.6.1.4.1.2.6.159.201.1.2.3.4 | The drive workload monitor threshold has generated an event. | ||
| memoryMonitors | 1.3.6.1.4.1.2.6.159.201.1.2.4 | |||
| NTF lockedMemory | 1.3.6.1.4.1.2.6.159.201.1.2.4.1 | The locked memory monitor threshold has generated an event. | ||
| NTF memoryUsage | 1.3.6.1.4.1.2.6.159.201.1.2.4.2 | The memory usage monitor threshold has generated an event. | ||
| nicMonitors | 1.3.6.1.4.1.2.6.159.201.1.2.5 | |||
| ntPerfMonitors | 1.3.6.1.4.1.2.6.159.201.1.2.6 | |||
| NTF totalPrivilegedTimePercent | 1.3.6.1.4.1.2.6.159.201.1.2.6.1 | The percentage of total privileged time monitor threshold has generated an event. | ||
| NTF fileReadOperationsPerSec | 1.3.6.1.4.1.2.6.159.201.1.2.6.2 | The files read per second monitor threshold has generated an event. | ||
| tcpipMonitors | 1.3.6.1.4.1.2.6.159.201.1.2.7 | |||
| NTF udpPacketsSentPerSec | 1.3.6.1.4.1.2.6.159.201.1.2.7.1 | A threshold event for the number of UDP packets sent per second. | ||
| NTF udpPacketsReceivedPerSec | 1.3.6.1.4.1.2.6.159.201.1.2.7.2 | A threshold event for the number of UDP packets received per second. | ||
| NTF ipPacketsSentPerSec | 1.3.6.1.4.1.2.6.159.201.1.2.7.3 | A threshold event for the number of IP packets sent per second. | ||
| NTF ipPacketsReceivedPerSec | 1.3.6.1.4.1.2.6.159.201.1.2.7.4 | A threshold event for the number of IP packets received per second. | ||
| NTF ipErrorPacketsReceivedPerSec | 1.3.6.1.4.1.2.6.159.201.1.2.7.5 | A threshold event for the number of IP packets received with errors per second. | ||
| NTF tcpConnections | 1.3.6.1.4.1.2.6.159.201.1.2.7.6 | A threshold event for the number of TCP connections. | ||
| monitorEventDetails | 1.3.6.1.4.1.2.6.159.201.1.2.8 | |||
| STR actualValue | 1.3.6.1.4.1.2.6.159.201.1.2.8.1 | SnmpAdminString | read-only | The actual value of the monitor. |
| STR duration | 1.3.6.1.4.1.2.6.159.201.1.2.8.2 | DisplayString | read-only | The duration of this monitor. |
| STR monitorResource | 1.3.6.1.4.1.2.6.159.201.1.2.8.3 | SnmpAdminString | read-only | The monitor resource. |
| STR thresholdName | 1.3.6.1.4.1.2.6.159.201.1.2.8.4 | SnmpAdminString | read-only | The name of the monitor threshold. |
| STR thresholdValue | 1.3.6.1.4.1.2.6.159.201.1.2.8.5 | SnmpAdminString | read-only | The value of the monitor threshold. |
| test | 1.3.6.1.4.1.2.6.159.201.1.3 | |||
| NTF action | 1.3.6.1.4.1.2.6.159.201.1.3.1 | The test action event. An internally generated event for the purpose of testing the action configuration. | ||
| console | 1.3.6.1.4.1.2.6.159.201.1.4 | |||
| consoleEventDetails | 1.3.6.1.4.1.2.6.159.201.1.4.1 | |||
| STR userID | 1.3.6.1.4.1.2.6.159.201.1.4.1.1 | SnmpAdminString | read-only | The console user ID. |
| STR address | 1.3.6.1.4.1.2.6.159.201.1.4.1.2 | SnmpAdminString | read-only | The console address. |
| STR userName | 1.3.6.1.4.1.2.6.159.201.1.4.1.3 | SnmpAdminString | read-only | The console username. |
| STR userDescription | 1.3.6.1.4.1.2.6.159.201.1.4.1.4 | SnmpAdminString | read-only | The console username's description. |
| STR userLocale | 1.3.6.1.4.1.2.6.159.201.1.4.1.5 | SnmpAdminString | read-only | The console user's locale. |
| logonFailure | 1.3.6.1.4.1.2.6.159.201.1.4.2 | |||
| NTF badPassword | 1.3.6.1.4.1.2.6.159.201.1.4.2.1 | When attempting to logon to the console, a bad password was used. | ||
| NTF badUserID | 1.3.6.1.4.1.2.6.159.201.1.4.2.2 | When attempting to logon to the console, a bad user ID was used. | ||
| NTF disabledUserID | 1.3.6.1.4.1.2.6.159.201.1.4.2.3 | When attempting to logon to the console, a disabled user ID was used. | ||
| NTF downlevelConsole | 1.3.6.1.4.1.2.6.159.201.1.4.2.4 | When attempting to logon to the console, a downlevel console was used. | ||
| NTF expiredPassword | 1.3.6.1.4.1.2.6.159.201.1.4.2.5 | When attempting to logon to the console, an expired password was used. | ||
| NTF tooManyActiveIDs | 1.3.6.1.4.1.2.6.159.201.1.4.2.6 | When attempting to logon to the console, too many IDs were active. | ||
| NTF tooManyActiveLogons | 1.3.6.1.4.1.2.6.159.201.1.4.2.7 | When attempting to logon to the console, too many logons were active. | ||
| NTF uplevelConsole | 1.3.6.1.4.1.2.6.159.201.1.4.2.8 | When attempting to logon to the console, an uplevel console was used. | ||
| NTF logoff | 1.3.6.1.4.1.2.6.159.201.1.4.3 | A user has logged off the console. | ||
| NTF logon | 1.3.6.1.4.1.2.6.159.201.1.4.4 | A user has logged on the console. | ||
| NTF generalEvent | 1.3.6.1.4.1.2.6.159.201.2 | This is a IBM Director event converted into an SNMP trap. This trap is only used for events with no mapping. | ||
| cimFamily | 1.3.6.1.4.1.2.6.159.201.3 | |||
| windowsNTEventLog | 1.3.6.1.4.1.2.6.159.201.3.1 | |||
| windowsNTEventLogEventDetails | 1.3.6.1.4.1.2.6.159.201.3.1.1 | |||
| I32 category | 1.3.6.1.4.1.2.6.159.201.3.1.1.1 | Integer32 | read-only | The Windows Event Log category. |
| STR categoryString | 1.3.6.1.4.1.2.6.159.201.3.1.1.2 | SnmpAdminString | read-only | The Windows Event Log category string. |
| STR computerName | 1.3.6.1.4.1.2.6.159.201.3.1.1.3 | SnmpAdminString | read-only | The computer name of the Windows Event Log event. |
| OCT data | 1.3.6.1.4.1.2.6.159.201.3.1.1.4 | OCTET STRING | read-only | The Windows Event Log data for the event. |
| I32 eventLogCode | 1.3.6.1.4.1.2.6.159.201.3.1.1.5 | Integer32 | read-only | The Windows Event Log numeric event ID. |
| STR eventLogIdentifier | 1.3.6.1.4.1.2.6.159.201.3.1.1.6 | DisplayString | read-only | The Windows Event Log numeric event identifier. |
| I32 eventLogType | 1.3.6.1.4.1.2.6.159.201.3.1.1.7 | Integer32 | read-only | The Windows Event Log numeric event type. |
| STR insertionStrings | 1.3.6.1.4.1.2.6.159.201.3.1.1.8 | SnmpAdminString | read-only | The Windows Event Log insertion strings. |
| STR logFile | 1.3.6.1.4.1.2.6.159.201.3.1.1.9 | SnmpAdminString | read-only | The Windows Event Log file name. |
| STR message | 1.3.6.1.4.1.2.6.159.201.3.1.1.10 | SnmpAdminString | read-only | The Windows Event Log message string. |
| STR recordNumber | 1.3.6.1.4.1.2.6.159.201.3.1.1.11 | DisplayString | read-only | The Windows Event Log record number. |
| STR sourceName | 1.3.6.1.4.1.2.6.159.201.3.1.1.12 | SnmpAdminString | read-only | The Windows Event Log source name. |
| STR type | 1.3.6.1.4.1.2.6.159.201.3.1.1.13 | SnmpAdminString | read-only | The Windows Event Log type. |
| STR user | 1.3.6.1.4.1.2.6.159.201.3.1.1.14 | SnmpAdminString | read-only | The Windows Event Log user. |
| NTF applicationLog | 1.3.6.1.4.1.2.6.159.201.3.1.2 | The Windows NT application event log has changed. | ||
| NTF securityLog | 1.3.6.1.4.1.2.6.159.201.3.1.3 | The Windows NT application security log has changed. | ||
| NTF systemLog | 1.3.6.1.4.1.2.6.159.201.3.1.4 | The Windows NT application system log has changed. | ||
| windowsNTService | 1.3.6.1.4.1.2.6.159.201.3.2 | |||
| windowsNTServiceEventDetails | 1.3.6.1.4.1.2.6.159.201.3.2.1 | |||
| T/F acceptPause | 1.3.6.1.4.1.2.6.159.201.3.2.1.1 | TruthValue | read-only | Whether this service accepts the pause state change. |
| T/F acceptStop | 1.3.6.1.4.1.2.6.159.201.3.2.1.2 | TruthValue | read-only | Whether this service accepts the stop state change. |
| STR caption | 1.3.6.1.4.1.2.6.159.201.3.2.1.3 | SnmpAdminString | read-only | The caption string for this service. |
| STR checkPoint | 1.3.6.1.4.1.2.6.159.201.3.2.1.4 | DisplayString | read-only | The service's check point. |
| STR creationClassName | 1.3.6.1.4.1.2.6.159.201.3.2.1.5 | SnmpAdminString | read-only | The creation class name for the service. |
| STR serviceDescription | 1.3.6.1.4.1.2.6.159.201.3.2.1.6 | SnmpAdminString | read-only | The description of the service. |
| T/F desktopInteract | 1.3.6.1.4.1.2.6.159.201.3.2.1.7 | TruthValue | read-only | Whether the service interacts with the desktop. |
| STR displayName | 1.3.6.1.4.1.2.6.159.201.3.2.1.8 | SnmpAdminString | read-only | The displayable name for the service. |
| STR errorControl | 1.3.6.1.4.1.2.6.159.201.3.2.1.9 | SnmpAdminString | read-only | The error control value for the service. |
| STR exitCode | 1.3.6.1.4.1.2.6.159.201.3.2.1.10 | DisplayString | read-only | The exit code of the process for the service. |
| STR name | 1.3.6.1.4.1.2.6.159.201.3.2.1.11 | SnmpAdminString | read-only | The name of the service. |
| STR pathName | 1.3.6.1.4.1.2.6.159.201.3.2.1.12 | SnmpAdminString | read-only | The path name for the service. |
| STR processId | 1.3.6.1.4.1.2.6.159.201.3.2.1.13 | DisplayString | read-only | The process ID of the running service. |
| STR serviceSpecificExitCode | 1.3.6.1.4.1.2.6.159.201.3.2.1.14 | DisplayString | read-only | The specific exit code for the service. |
| STR serviceType | 1.3.6.1.4.1.2.6.159.201.3.2.1.15 | SnmpAdminString | read-only | The type of service. |
| STR startMode | 1.3.6.1.4.1.2.6.159.201.3.2.1.16 | SnmpAdminString | read-only | The start mode for the service. |
| STR startName | 1.3.6.1.4.1.2.6.159.201.3.2.1.17 | SnmpAdminString | read-only | The start name for the service. |
| T/F started | 1.3.6.1.4.1.2.6.159.201.3.2.1.18 | TruthValue | read-only | Whether this service has started. |
| STR serviceState | 1.3.6.1.4.1.2.6.159.201.3.2.1.19 | SnmpAdminString | read-only | The state of the service. |
| STR status | 1.3.6.1.4.1.2.6.159.201.3.2.1.20 | SnmpAdminString | read-only | The status of the service. |
| STR systemCreationClassName | 1.3.6.1.4.1.2.6.159.201.3.2.1.21 | SnmpAdminString | read-only | The system creation class name for the service. |
| STR systemName | 1.3.6.1.4.1.2.6.159.201.3.2.1.22 | SnmpAdminString | read-only | The system name for the service. |
| STR tagId | 1.3.6.1.4.1.2.6.159.201.3.2.1.23 | DisplayString | read-only | The tag ID of the service. |
| STR waitHint | 1.3.6.1.4.1.2.6.159.201.3.2.1.24 | DisplayString | read-only | The value of the wait hint for the service. |
| NTF startedService | 1.3.6.1.4.1.2.6.159.201.3.2.2 | A Windows NT service has started. | ||
| NTF stoppedService | 1.3.6.1.4.1.2.6.159.201.3.2.3 | A Windows NT service has stopped. | ||
| windowsRegistry | 1.3.6.1.4.1.2.6.159.201.3.3 | |||
| windowsRegistryEventDetails | 1.3.6.1.4.1.2.6.159.201.3.3.1 | |||
| STR hive | 1.3.6.1.4.1.2.6.159.201.3.3.1.1 | SnmpAdminString | read-only | The Windows Registry hive for this event. |
| STR rootPath | 1.3.6.1.4.1.2.6.159.201.3.3.1.2 | SnmpAdminString | read-only | The Windows Registry root path for this event. |
| OCT securityDescriptor | 1.3.6.1.4.1.2.6.159.201.3.3.1.3 | OCTET STRING | read-only | The Windows Registry security descriptor for this event. |
| STR timeCreated | 1.3.6.1.4.1.2.6.159.201.3.3.1.4 | SnmpAdminString | read-only | The time this item was created in the Windows Registry. |
| NTF softwareTreeChanged | 1.3.6.1.4.1.2.6.159.201.3.3.2 | The Windows software tree section of the registry has changed. | ||
| NTF systemTreeChanged | 1.3.6.1.4.1.2.6.159.201.3.3.3 | The Windows system tree section of the registry has changed. | ||
| mpaFamily | 1.3.6.1.4.1.2.6.159.201.4 | |||
| mpaEventDetails | 1.3.6.1.4.1.2.6.159.201.4.1 | |||
| I32 alertCode | 1.3.6.1.4.1.2.6.159.201.4.1.1 | Integer32 | read-only | The alert code. |
| I32 busId | 1.3.6.1.4.1.2.6.159.201.4.1.2 | Integer32 | read-only | The bus ID. |
| STR componentId | 1.3.6.1.4.1.2.6.159.201.4.1.3 | SnmpAdminString | read-only | The component ID. |
| OCT firmwareCode | 1.3.6.1.4.1.2.6.159.201.4.1.4 | OCTET STRING | read-only | The firmware identification code. |
| OCT ipAddress1 | 1.3.6.1.4.1.2.6.159.201.4.1.5 | OCTET STRING | read-only | The first IP address. |
| OCT ipAddress2 | 1.3.6.1.4.1.2.6.159.201.4.1.6 | OCTET STRING | read-only | The second IP address. |
| STR issue | 1.3.6.1.4.1.2.6.159.201.4.1.7 | SnmpAdminString | read-only | The issue for the event. |
| I32 powerDomain | 1.3.6.1.4.1.2.6.159.201.4.1.8 | Integer32 | read-only | The domain of the power supply. |
| STR reason | 1.3.6.1.4.1.2.6.159.201.4.1.9 | SnmpAdminString | read-only | The reason for the event. |
| I32 scsiId | 1.3.6.1.4.1.2.6.159.201.4.1.10 | Integer32 | read-only | The ID of the SCSI device. |
| STR side | 1.3.6.1.4.1.2.6.159.201.4.1.11 | SnmpAdminString | read-only | The side in which the event occured. |
| STR newState | 1.3.6.1.4.1.2.6.159.201.4.1.12 | SnmpAdminString | read-only | The new state. |
| STR temperatureSensor | 1.3.6.1.4.1.2.6.159.201.4.1.13 | SnmpAdminString | read-only | The current temperature. |
| STR threshold | 1.3.6.1.4.1.2.6.159.201.4.1.14 | SnmpAdminString | read-only | The threshold for the event. |
| OCT universalUniqueId | 1.3.6.1.4.1.2.6.159.201.4.1.15 | OCTET STRING | read-only | The universal unique ID. |
| OCT senderUniversalUniqueId | 1.3.6.1.4.1.2.6.159.201.4.1.16 | OCTET STRING | read-only | The universal unique ID of the sender. |
| OCT sourceUniversalUniqueId | 1.3.6.1.4.1.2.6.159.201.4.1.17 | OCTET STRING | read-only | The universal unique ID of the source. |
| I32 unitNumber | 1.3.6.1.4.1.2.6.159.201.4.1.18 | Integer32 | read-only | The unit number. |
| STR voltageSensor | 1.3.6.1.4.1.2.6.159.201.4.1.19 | SnmpAdminString | read-only | The voltage sensor. |
| component | 1.3.6.1.4.1.2.6.159.201.4.2 | |||
| bladeServer | 1.3.6.1.4.1.2.6.159.201.4.2.1 | |||
| coD | 1.3.6.1.4.1.2.6.159.201.4.2.1.1 | |||
| NTF codEnabled | 1.3.6.1.4.1.2.6.159.201.4.2.1.1.1 | The CoD has been enabled. | ||
| NTF bladeServerCommunication | 1.3.6.1.4.1.2.6.159.201.4.2.1.2 | Communication with a blade has been established. | ||
| NTF bladeServerInserted | 1.3.6.1.4.1.2.6.159.201.4.2.1.3 | A blade has been inserted. | ||
| NTF bladeServerRemoved | 1.3.6.1.4.1.2.6.159.201.4.2.1.4 | A blade has been removed. | ||
| bus | 1.3.6.1.4.1.2.6.159.201.4.2.2 | |||
| NTF busCommunication | 1.3.6.1.4.1.2.6.159.201.4.2.2.1 | Communication with a bus has been established. | ||
| chassis | 1.3.6.1.4.1.2.6.159.201.4.2.3 | |||
| NTF chassisConfiguration | 1.3.6.1.4.1.2.6.159.201.4.2.3.1 | The blade chassis configuration has changed. | ||
| NTF chassisFailed | 1.3.6.1.4.1.2.6.159.201.4.2.3.2 | The blade chassis has failed. | ||
| dasd | 1.3.6.1.4.1.2.6.159.201.4.2.4 | |||
| NTF dasdFailed | 1.3.6.1.4.1.2.6.159.201.4.2.4.1 | a direct access storage device has failed. | ||
| NTF dasdInserted | 1.3.6.1.4.1.2.6.159.201.4.2.4.2 | A direct access storage device has been inserted. | ||
| NTF dasdRemoved | 1.3.6.1.4.1.2.6.159.201.4.2.4.3 | A direct access storage device has been removed. | ||
| memory | 1.3.6.1.4.1.2.6.159.201.4.2.5 | |||
| NTF memoryFailed | 1.3.6.1.4.1.2.6.159.201.4.2.5.1 | Some memory has failed. | ||
| componentFan | 1.3.6.1.4.1.2.6.159.201.4.2.6 | |||
| NTF componentFanFailed | 1.3.6.1.4.1.2.6.159.201.4.2.6.1 | A fan has failed. | ||
| NTF componentFanInserted | 1.3.6.1.4.1.2.6.159.201.4.2.6.2 | A fan has been inserted. | ||
| NTF componentFanPfa | 1.3.6.1.4.1.2.6.159.201.4.2.6.3 | The fan component has generated a PFA. | ||
| NTF componentFanRemoved | 1.3.6.1.4.1.2.6.159.201.4.2.6.4 | A fan has been removed. | ||
| hardwareInformation | 1.3.6.1.4.1.2.6.159.201.4.2.7 | |||
| hardwareCrashDump | 1.3.6.1.4.1.2.6.159.201.4.2.7.1 | |||
| NTF hardwareCrashDumpAborted | 1.3.6.1.4.1.2.6.159.201.4.2.7.1.1 | A hardware crash dump was aborted. | ||
| NTF hardwareCrashDumpCompleted | 1.3.6.1.4.1.2.6.159.201.4.2.7.1.2 | A hardware crash dump has completed. | ||
| NTF hardwareCrashDumpInitiated | 1.3.6.1.4.1.2.6.159.201.4.2.7.1.3 | A hardware crash dump has been initiated. | ||
| ioModule | 1.3.6.1.4.1.2.6.159.201.4.2.8 | |||
| NTF ioModuleConfiguration | 1.3.6.1.4.1.2.6.159.201.4.2.8.1 | An I/O module's configuration has changed. | ||
| NTF ioModuleFailed | 1.3.6.1.4.1.2.6.159.201.4.2.8.2 | An I/O module has failed. | ||
| NTF ioModuleInserted | 1.3.6.1.4.1.2.6.159.201.4.2.8.3 | An I/O module has been inserted. | ||
| NTF ioModulePost | 1.3.6.1.4.1.2.6.159.201.4.2.8.4 | An I/O module has past POST. | ||
| ioModulePower | 1.3.6.1.4.1.2.6.159.201.4.2.8.5 | |||
| NTF ioModulePowerOn | 1.3.6.1.4.1.2.6.159.201.4.2.8.5.1 | An I/O module has been powered on. | ||
| NTF ioModulePowerOff | 1.3.6.1.4.1.2.6.159.201.4.2.8.5.2 | An I/O module has been powered off. | ||
| NTF ioModuleRedundancy | 1.3.6.1.4.1.2.6.159.201.4.2.8.6 | An I/O module is a redundancy. | ||
| NTF ioModuleRemoved | 1.3.6.1.4.1.2.6.159.201.4.2.8.7 | An I/O module has been removed. | ||
| kvm | 1.3.6.1.4.1.2.6.159.201.4.2.9 | |||
| NTF kvmOwner | 1.3.6.1.4.1.2.6.159.201.4.2.9.1 | The KVM owner has changed. | ||
| osImage | 1.3.6.1.4.1.2.6.159.201.4.2.10 | |||
| osImageCrashDump | 1.3.6.1.4.1.2.6.159.201.4.2.10.1 | |||
| NTF osImageCrashDumpAborted | 1.3.6.1.4.1.2.6.159.201.4.2.10.1.1 | The operating system image crash dump was aborted. | ||
| NTF osImageCrashDumpCompleted | 1.3.6.1.4.1.2.6.159.201.4.2.10.1.2 | The operating system image crash dump has completed. | ||
| NTF osImageCrashDumpInitiated | 1.3.6.1.4.1.2.6.159.201.4.2.10.1.3 | The operating system image crash dump has been initiated. | ||
| NTF componentPfa | 1.3.6.1.4.1.2.6.159.201.4.2.11 | A component has generated a PFA. | ||
| powerSubsystem | 1.3.6.1.4.1.2.6.159.201.4.2.12 | |||
| NTF powerSubsystemLowFuel | 1.3.6.1.4.1.2.6.159.201.4.2.12.1 | The power subsystem indicates low fuel. | ||
| NTF powerSubsystemOverCurrent | 1.3.6.1.4.1.2.6.159.201.4.2.12.2 | The power subsystem indicates over current. | ||
| NTF powerSubsystemOverPower | 1.3.6.1.4.1.2.6.159.201.4.2.12.3 | The power subsystem indicates over power. | ||
| NTF powerSubsystemRedundancy | 1.3.6.1.4.1.2.6.159.201.4.2.12.4 | The power subsystem indicates a redundancy. | ||
| powerSupply | 1.3.6.1.4.1.2.6.159.201.4.2.13 | |||
| NTF powerSupplyFailed | 1.3.6.1.4.1.2.6.159.201.4.2.13.1 | A power supply has failed. | ||
| NTF powerSupplyInserted | 1.3.6.1.4.1.2.6.159.201.4.2.13.2 | A power supply has been inserted. | ||
| NTF powerSupplyRemoved | 1.3.6.1.4.1.2.6.159.201.4.2.13.3 | A power supply has been removed. | ||
| server | 1.3.6.1.4.1.2.6.159.201.4.2.14 | |||
| serverPower | 1.3.6.1.4.1.2.6.159.201.4.2.14.1 | |||
| NTF serverPowerOff | 1.3.6.1.4.1.2.6.159.201.4.2.14.1.1 | The server has powered off. | ||
| NTF serverPowerOn | 1.3.6.1.4.1.2.6.159.201.4.2.14.1.2 | The server has powered on. | ||
| NTF serverPowerState | 1.3.6.1.4.1.2.6.159.201.4.2.14.2 | The server's power state has changed. | ||
| serviceProcessor | 1.3.6.1.4.1.2.6.159.201.4.2.15 | |||
| NTF serviceProcessorActive | 1.3.6.1.4.1.2.6.159.201.4.2.15.1 | A service processor is now active. | ||
| NTF serviceProcessorConfiguration | 1.3.6.1.4.1.2.6.159.201.4.2.15.2 | A service processor configuration has changed. | ||
| NTF serviceProcessorInserted | 1.3.6.1.4.1.2.6.159.201.4.2.15.3 | A service processor has been inserted. | ||
| NTF serviceProcessorLog | 1.3.6.1.4.1.2.6.159.201.4.2.15.4 | A service processor has generated a log. | ||
| NTF serviceProcessorNetworkStack | 1.3.6.1.4.1.2.6.159.201.4.2.15.5 | A service processor network stack has changed. | ||
| NTF serviceProcessorRedundancy | 1.3.6.1.4.1.2.6.159.201.4.2.15.6 | A service processor detected a redundancy. | ||
| NTF serviceProcessorRemoteLogin | 1.3.6.1.4.1.2.6.159.201.4.2.15.7 | A remove login was made into the service processor. | ||
| NTF serviceProcessorRemoved | 1.3.6.1.4.1.2.6.159.201.4.2.15.8 | A service processor has been removed. | ||
| NTF serviceProcessorRestart | 1.3.6.1.4.1.2.6.159.201.4.2.15.9 | A service processor has been restarted. | ||
| NTF serviceProcessorTest | 1.3.6.1.4.1.2.6.159.201.4.2.15.10 | A service processor test was issued. | ||
| smpExpansionModule | 1.3.6.1.4.1.2.6.159.201.4.2.16 | |||
| NTF smpExpansionModuleDisabled | 1.3.6.1.4.1.2.6.159.201.4.2.16.1 | An SMP expansion module has been disabled. | ||
| usb | 1.3.6.1.4.1.2.6.159.201.4.2.17 | |||
| NTF usbInserted | 1.3.6.1.4.1.2.6.159.201.4.2.17.1 | A USB device has been inserted. | ||
| NTF usbOwner | 1.3.6.1.4.1.2.6.159.201.4.2.17.2 | A USB device owner has changed. | ||
| NTF usbRemoved | 1.3.6.1.4.1.2.6.159.201.4.2.17.3 | A USB device has been removed. | ||
| vrm | 1.3.6.1.4.1.2.6.159.201.4.2.18 | |||
| NTF vrmFailed | 1.3.6.1.4.1.2.6.159.201.4.2.18.1 | The VRM has failed. | ||
| critical | 1.3.6.1.4.1.2.6.159.201.4.3 | |||
| NTF hardDiskDrive | 1.3.6.1.4.1.2.6.159.201.4.3.1 | A hard disk drive is in critical state. | ||
| NTF multipleFanFailure | 1.3.6.1.4.1.2.6.159.201.4.3.2 | Multiple fans have failed. | ||
| powerFailure | 1.3.6.1.4.1.2.6.159.201.4.3.3 | |||
| NTF powerFailureEpow | 1.3.6.1.4.1.2.6.159.201.4.3.3.1 | There was a critical power failure as a result of an EPOW. | ||
| NTF powerFailureFailed | 1.3.6.1.4.1.2.6.159.201.4.3.3.2 | There was a critical power failure as a result of something failing. | ||
| NTF powerFailureRemoved | 1.3.6.1.4.1.2.6.159.201.4.3.3.3 | There was a critical power failure as a result of something removed. | ||
| NTF criticalTamper | 1.3.6.1.4.1.2.6.159.201.4.3.4 | Tampering with the system has caused a critical state. | ||
| criticalTemperature | 1.3.6.1.4.1.2.6.159.201.4.3.5 | |||
| NTF criticalTemperatureAmbient | 1.3.6.1.4.1.2.6.159.201.4.3.5.1 | The ambient temperature is in a critical state. | ||
| NTF criticalTemperaturePci | 1.3.6.1.4.1.2.6.159.201.4.3.5.2 | The PCI temperature is in a critical state. | ||
| NTF criticalTemperaturePlanar | 1.3.6.1.4.1.2.6.159.201.4.3.5.3 | The planar temperature is in a critical state. | ||
| criticalVoltage | 1.3.6.1.4.1.2.6.159.201.4.3.6 | |||
| criticalTwelveVolts | 1.3.6.1.4.1.2.6.159.201.4.3.6.1 | |||
| NTF criticalTwelveVoltsHigh | 1.3.6.1.4.1.2.6.159.201.4.3.6.1.1 | A critical state of 12V high has been detected. | ||
| NTF criticalTwelveVoltsLow | 1.3.6.1.4.1.2.6.159.201.4.3.6.1.2 | A critical state of 12V low has been detected. | ||
| NTF criticalTwelveVoltsFaultA | 1.3.6.1.4.1.2.6.159.201.4.3.6.2 | A critical state of 12V fault A has been detected. | ||
| NTF criticalTwelveVoltsFaultB | 1.3.6.1.4.1.2.6.159.201.4.3.6.3 | A critical state of 12V fault B has been detected. | ||
| NTF criticalTwelveVoltsFaultC | 1.3.6.1.4.1.2.6.159.201.4.3.6.4 | A critical state of 12V fault C has been detected. | ||
| NTF criticalTwelveVoltsFaultD | 1.3.6.1.4.1.2.6.159.201.4.3.6.5 | A critical state of 12V fault D has been detected. | ||
| criticalOneVolt | 1.3.6.1.4.1.2.6.159.201.4.3.6.6 | |||
| NTF criticalOneVoltHigh | 1.3.6.1.4.1.2.6.159.201.4.3.6.6.1 | A critical state of 1V high has been detected. | ||
| NTF criticalOneVoltLow | 1.3.6.1.4.1.2.6.159.201.4.3.6.6.2 | A critical state of 1V low has been detected. | ||
| criticalTwoVolts | 1.3.6.1.4.1.2.6.159.201.4.3.6.7 | |||
| NTF criticalTwoVoltsHigh | 1.3.6.1.4.1.2.6.159.201.4.3.6.7.1 | A critical state of 2V high has been detected. | ||
| NTF criticalTwoVoltsLow | 1.3.6.1.4.1.2.6.159.201.4.3.6.7.2 | A critical state of 2V low has been detected. | ||
| criticalThreeVolts | 1.3.6.1.4.1.2.6.159.201.4.3.6.8 | |||
| NTF criticalThreeVoltsHigh | 1.3.6.1.4.1.2.6.159.201.4.3.6.8.1 | A critical state of 3V high has been detected. | ||
| NTF criticalThreeVoltsLow | 1.3.6.1.4.1.2.6.159.201.4.3.6.8.2 | A critical state of 3V low has been detected. | ||
| criticalThreeVoltsPci | 1.3.6.1.4.1.2.6.159.201.4.3.6.9 | |||
| NTF criticalThreeVoltsPciHigh | 1.3.6.1.4.1.2.6.159.201.4.3.6.9.1 | A critical state of 3V high has been detected for the PCI. | ||
| NTF criticalThreeVoltsPciLow | 1.3.6.1.4.1.2.6.159.201.4.3.6.9.2 | A critical state of 3V low has been detected for the PCI. | ||
| criticalThreeVoltsStandby | 1.3.6.1.4.1.2.6.159.201.4.3.6.10 | |||
| NTF criticalThreeVoltsStandbyHigh | 1.3.6.1.4.1.2.6.159.201.4.3.6.10.1 | A critical state of 3V standby high has been detected. | ||
| NTF criticalThreeVoltsStandbyLow | 1.3.6.1.4.1.2.6.159.201.4.3.6.10.2 | A critical state of 3V standby low has been detected. | ||
| criticalFiveVolts | 1.3.6.1.4.1.2.6.159.201.4.3.6.11 | |||
| NTF criticalFiveVoltsHigh | 1.3.6.1.4.1.2.6.159.201.4.3.6.11.1 | A critical state of 5V high has been detected. | ||
| NTF criticalFiveVoltsLow | 1.3.6.1.4.1.2.6.159.201.4.3.6.11.2 | A critical state of 5V low has been detected. | ||
| criticalFiveVoltsFault | 1.3.6.1.4.1.2.6.159.201.4.3.6.12 | |||
| NTF criticalFiveVoltsFaultHigh | 1.3.6.1.4.1.2.6.159.201.4.3.6.12.1 | A critical state of 5V fault high has been detected. | ||
| NTF criticalFiveVoltsFaultLow | 1.3.6.1.4.1.2.6.159.201.4.3.6.12.2 | A critical state of 5V fault low has been detected. | ||
| criticalFiveVoltsPci | 1.3.6.1.4.1.2.6.159.201.4.3.6.13 | |||
| NTF criticalFiveVoltsPciHigh | 1.3.6.1.4.1.2.6.159.201.4.3.6.13.1 | A critical state of 5V high has been detected for the PCI. | ||
| NTF criticalFiveVoltsPciLow | 1.3.6.1.4.1.2.6.159.201.4.3.6.13.2 | A critical state of 5V low has been detected for the PCI. | ||
| criticalFiveVoltsStandby | 1.3.6.1.4.1.2.6.159.201.4.3.6.14 | |||
| NTF criticalFiveVoltsStandbyHigh | 1.3.6.1.4.1.2.6.159.201.4.3.6.14.1 | A critical state of 5V standby high has been detected. | ||
| NTF criticalFiveVoltsStandbyLow | 1.3.6.1.4.1.2.6.159.201.4.3.6.14.2 | A critical state of 5V standby low has been detected. | ||
| criticalNTwelveVolts | 1.3.6.1.4.1.2.6.159.201.4.3.6.15 | |||
| NTF criticalNTwelveVoltsHigh | 1.3.6.1.4.1.2.6.159.201.4.3.6.15.1 | A critical state of negative 12V high has been detected. | ||
| NTF criticalNTwelveVoltsLow | 1.3.6.1.4.1.2.6.159.201.4.3.6.15.2 | A critical state of negative 12V low has been detected. | ||
| NTF voltageRegulatorModuleFailure | 1.3.6.1.4.1.2.6.159.201.4.3.7 | The voltage regulator module has failed. | ||
| deployment | 1.3.6.1.4.1.2.6.159.201.4.4 | |||
| NTF deploymentBoot | 1.3.6.1.4.1.2.6.159.201.4.4.1 | Deployment has generated a boot event. | ||
| NTF deploymentLoader | 1.3.6.1.4.1.2.6.159.201.4.4.2 | Deployment has generated a loader event. | ||
| NTF deploymentOs | 1.3.6.1.4.1.2.6.159.201.4.4.3 | Deployment has generated an operating system event. | ||
| NTF deploymentPost | 1.3.6.1.4.1.2.6.159.201.4.4.4 | Deployment has generated a POST event. | ||
| environmental | 1.3.6.1.4.1.2.6.159.201.4.5 | |||
| NTF environmentalTemperature | 1.3.6.1.4.1.2.6.159.201.4.5.1 | The environmental temperature has changed. | ||
| NTF environmentalVoltage | 1.3.6.1.4.1.2.6.159.201.4.5.2 | The environmental voltage has changed. | ||
| nonCritical | 1.3.6.1.4.1.2.6.159.201.4.6 | |||
| nonCriticalFan | 1.3.6.1.4.1.2.6.159.201.4.6.1 | |||
| NTF nonCriticalFanRemoved | 1.3.6.1.4.1.2.6.159.201.4.6.1.1 | A fan has been removed. | ||
| NTF redundantPower | 1.3.6.1.4.1.2.6.159.201.4.6.2 | The system is now running on redundant power. | ||
| NTF singleFanFailure | 1.3.6.1.4.1.2.6.159.201.4.6.3 | A single fan has failed. | ||
| nonCriticalTemperature | 1.3.6.1.4.1.2.6.159.201.4.6.4 | |||
| NTF nonCriticalTemperatureAmbient | 1.3.6.1.4.1.2.6.159.201.4.6.4.1 | The ambient temperature is in a non critical state. | ||
| NTF nonCriticalTemperaturePci | 1.3.6.1.4.1.2.6.159.201.4.6.4.2 | The PCI temperature is in a non critical state. | ||
| NTF nonCriticalTemperaturePlanar | 1.3.6.1.4.1.2.6.159.201.4.6.4.3 | The planar temperature is in a non critical state. | ||
| nonCriticalVoltage | 1.3.6.1.4.1.2.6.159.201.4.6.5 | |||
| nonCriticalTwelveVolts | 1.3.6.1.4.1.2.6.159.201.4.6.5.1 | |||
| NTF nonCriticalTwelveVoltsHigh | 1.3.6.1.4.1.2.6.159.201.4.6.5.1.1 | A non-critical state of 12V high has been detected. | ||
| NTF nonCriticalTwelveVoltsLow | 1.3.6.1.4.1.2.6.159.201.4.6.5.1.2 | A non-critical state of 12V low has been detected. | ||
| nonCriticalOneVolt | 1.3.6.1.4.1.2.6.159.201.4.6.5.2 | |||
| NTF nonCriticalOneVoltHigh | 1.3.6.1.4.1.2.6.159.201.4.6.5.2.1 | A non-critical state of 1V high has been detected. | ||
| NTF nonCriticalOneVoltLow | 1.3.6.1.4.1.2.6.159.201.4.6.5.2.2 | A non-critical state of 1V low has been detected. | ||
| nonCriticalTwoVolts | 1.3.6.1.4.1.2.6.159.201.4.6.5.3 | |||
| NTF nonCriticalTwoVoltsHigh | 1.3.6.1.4.1.2.6.159.201.4.6.5.3.1 | A non-critical state of 2V high has been detected. | ||
| NTF nonCriticalTwoVoltsLow | 1.3.6.1.4.1.2.6.159.201.4.6.5.3.2 | A non-critical state of 2V low has been detected. | ||
| nonCriticalThreeVolts | 1.3.6.1.4.1.2.6.159.201.4.6.5.4 | |||
| NTF nonCriticalThreeVoltsHigh | 1.3.6.1.4.1.2.6.159.201.4.6.5.4.1 | A non-critical state of 3V high has been detected. | ||
| NTF nonCriticalThreeVoltsLow | 1.3.6.1.4.1.2.6.159.201.4.6.5.4.2 | A non-critical state of 3V low has been detected. | ||
| nonCriticalThreeVoltsPci | 1.3.6.1.4.1.2.6.159.201.4.6.5.5 | |||
| NTF nonCriticalThreeVoltsPciHigh | 1.3.6.1.4.1.2.6.159.201.4.6.5.5.1 | A non-critical state of 3V high has been detected for the PCI. | ||
| NTF nonCriticalThreeVoltsPciLow | 1.3.6.1.4.1.2.6.159.201.4.6.5.5.2 | A non-critical state of 3V low has been detected for the PCI. | ||
| nonCriticalThreeVoltsStandby | 1.3.6.1.4.1.2.6.159.201.4.6.5.6 | |||
| NTF nonCriticalThreeVoltsStandbyHigh | 1.3.6.1.4.1.2.6.159.201.4.6.5.6.1 | A non-critical state of 3V standby high has been detected. | ||
| NTF nonCriticalThreeVoltsStandbyLow | 1.3.6.1.4.1.2.6.159.201.4.6.5.6.2 | A non-critical state of 3V standby low has been detected. | ||
| nonCriticalFiveVolts | 1.3.6.1.4.1.2.6.159.201.4.6.5.7 | |||
| NTF nonCriticalFiveVoltsHigh | 1.3.6.1.4.1.2.6.159.201.4.6.5.7.1 | A non-critical state of 5V high has been detected. | ||
| NTF nonCriticalFiveVoltsLow | 1.3.6.1.4.1.2.6.159.201.4.6.5.7.2 | A non-critical state of 5V low has been detected. | ||
| nonCriticalFiveVoltsPci | 1.3.6.1.4.1.2.6.159.201.4.6.5.8 | |||
| NTF nonCriticalFiveVoltsPciHigh | 1.3.6.1.4.1.2.6.159.201.4.6.5.8.1 | A non-critical state of 5V high has been detected for the PCI. | ||
| NTF nonCriticalFiveVoltsPciLow | 1.3.6.1.4.1.2.6.159.201.4.6.5.8.2 | A non-critical state of 5V low has been detected for the PCI. | ||
| nonCriticalFiveVoltsStandby | 1.3.6.1.4.1.2.6.159.201.4.6.5.9 | |||
| NTF nonCriticalFiveVoltsStandbyHigh | 1.3.6.1.4.1.2.6.159.201.4.6.5.9.1 | A non-critical state of 5V standby high has been detected. | ||
| NTF nonCriticalFiveVoltsStandbyLow | 1.3.6.1.4.1.2.6.159.201.4.6.5.9.2 | A non-critical state of 5V standby low has been detected. | ||
| nonCriticalNTwelveVolts | 1.3.6.1.4.1.2.6.159.201.4.6.5.10 | |||
| NTF nonCriticalNTwelveVoltsHigh | 1.3.6.1.4.1.2.6.159.201.4.6.5.10.1 | A non-critical state of negative 12V high has been detected. | ||
| NTF nonCriticalNTwelveVoltsLow | 1.3.6.1.4.1.2.6.159.201.4.6.5.10.2 | A non-critical state of negative 12V low has been detected. | ||
| platform | 1.3.6.1.4.1.2.6.159.201.4.7 | |||
| scalableNode | 1.3.6.1.4.1.2.6.159.201.4.7.1 | |||
| scalableNodeMode | 1.3.6.1.4.1.2.6.159.201.4.7.1.1 | |||
| NTF scalableNodeModeNullOrUnknown | 1.3.6.1.4.1.2.6.159.201.4.7.1.1.1 | The scalable node is in a null or unknown mode. | ||
| NTF scalableNodeModePrimary | 1.3.6.1.4.1.2.6.159.201.4.7.1.1.2 | The scalable node is in primary mode. | ||
| NTF scalableNodeModeSecondary | 1.3.6.1.4.1.2.6.159.201.4.7.1.1.3 | The scalable node is in secondary mode. | ||
| NTF scalableNodeModeStandalone | 1.3.6.1.4.1.2.6.159.201.4.7.1.1.4 | The scalable node is now in standalone mode. | ||
| scalableNodeStandalone | 1.3.6.1.4.1.2.6.159.201.4.7.1.2 | |||
| standaloneMode | 1.3.6.1.4.1.2.6.159.201.4.7.1.2.1 | |||
| NTF primary | 1.3.6.1.4.1.2.6.159.201.4.7.1.2.1.1 | The scalable node is now in standalone primary mode. | ||
| reset | 1.3.6.1.4.1.2.6.159.201.4.7.1.2.1.2 | |||
| NTF resetPrimary | 1.3.6.1.4.1.2.6.159.201.4.7.1.2.1.2.1 | The scalable node is now in standalone primary reset mode. | ||
| NTF resetSecondary | 1.3.6.1.4.1.2.6.159.201.4.7.1.2.1.2.2 | The scalable node is now in standalone primary secondary mode. | ||
| NTF secondary | 1.3.6.1.4.1.2.6.159.201.4.7.1.2.1.3 | The scalable node is now in standalone secondary mode. | ||
| scalablePartition | 1.3.6.1.4.1.2.6.159.201.4.7.2 | |||
| NTF scalablePartitionAlert | 1.3.6.1.4.1.2.6.159.201.4.7.2.1 | The scalabel partition has generated an alert. | ||
| scalablePartitionState | 1.3.6.1.4.1.2.6.159.201.4.7.2.2 | |||
| NTF scalablePartitionNullOrUnknown | 1.3.6.1.4.1.2.6.159.201.4.7.2.2.1 | The scalable partition state is 'null or unknown'. | ||
| NTF scalablePartitionPoweredOff | 1.3.6.1.4.1.2.6.159.201.4.7.2.2.2 | The scalable partition state is 'powered off'. | ||
| NTF scalablePartitionPoweringOn | 1.3.6.1.4.1.2.6.159.201.4.7.2.2.3 | The scalable partition state is 'powering on'. | ||
| NTF scalablePartitionResetting | 1.3.6.1.4.1.2.6.159.201.4.7.2.2.4 | The scalable partition state is 'resetting'. | ||
| NTF scalablePartitionShuttingDown | 1.3.6.1.4.1.2.6.159.201.4.7.2.2.5 | The scalable partition state is 'shutting down'. | ||
| system | 1.3.6.1.4.1.2.6.159.201.4.8 | |||
| NTF bootFailure | 1.3.6.1.4.1.2.6.159.201.4.8.1 | The system indicated a boot failure. | ||
| fuelGauge | 1.3.6.1.4.1.2.6.159.201.4.8.2 | |||
| NTF fuelGaugeLowFuel | 1.3.6.1.4.1.2.6.159.201.4.8.2.1 | The fuel gauge indicates low fuel. | ||
| NTF fuelGaugeNotRedundant | 1.3.6.1.4.1.2.6.159.201.4.8.2.2 | The fuel gauge indicates not redundant. | ||
| NTF fuelGaugeOverCurrent | 1.3.6.1.4.1.2.6.159.201.4.8.2.3 | The fuel gauge indicates over current. | ||
| NTF systemLoaderTimeout | 1.3.6.1.4.1.2.6.159.201.4.8.3 | The system loader has timed out. | ||
| NTF systemOsTimeout | 1.3.6.1.4.1.2.6.159.201.4.8.4 | The operating system has timed out. | ||
| systemPfa | 1.3.6.1.4.1.2.6.159.201.4.8.5 | |||
| NTF fanSystemPfa | 1.3.6.1.4.1.2.6.159.201.4.8.5.1 | The fan system has generated a PFA. | ||
| NTF systemPostTimeout | 1.3.6.1.4.1.2.6.159.201.4.8.6 | The POST has timed out. | ||
| NTF systemPowerOff | 1.3.6.1.4.1.2.6.159.201.4.8.7 | The sytsem has powered off. | ||
| NTF systemPowerOn | 1.3.6.1.4.1.2.6.159.201.4.8.8 | The sytsem has powered on. | ||
| NTF systemRedundantPower | 1.3.6.1.4.1.2.6.159.201.4.8.9 | The system is running on redundant power. | ||
| NTF systemTamper | 1.3.6.1.4.1.2.6.159.201.4.8.10 | The system has been tampered with. | ||
| NTF unknown | 1.3.6.1.4.1.2.6.159.201.4.9 | The system is in an unknown state. | ||
| petFamily | 1.3.6.1.4.1.2.6.159.201.5 | |||
| petFamilyEventDetails | 1.3.6.1.4.1.2.6.159.201.5.1 | |||
| OCT allVariableBindings | 1.3.6.1.4.1.2.6.159.201.5.1.1 | OCTET STRING | read-only | All of the variable bindings for this PET trap. |
| OCT entity | 1.3.6.1.4.1.2.6.159.201.5.1.2 | OCTET STRING | read-only | The entity of this PET event. |
| OCT entityInstance | 1.3.6.1.4.1.2.6.159.201.5.1.3 | OCTET STRING | read-only | The entity instance of this PET event. |
| OCT petEventData | 1.3.6.1.4.1.2.6.159.201.5.1.4 | OCTET STRING | read-only | The event data of this PET event. |
| OCT petEventSeverity | 1.3.6.1.4.1.2.6.159.201.5.1.5 | OCTET STRING | read-only | The severity of this PET event. |
| OCT petEventSourceType | 1.3.6.1.4.1.2.6.159.201.5.1.6 | OCTET STRING | read-only | The source type of this PET event. |
| OCT petEventType | 1.3.6.1.4.1.2.6.159.201.5.1.7 | OCTET STRING | read-only | The type of the PET event. |
| OCT guid | 1.3.6.1.4.1.2.6.159.201.5.1.8 | OCTET STRING | read-only | The GUID for this PET event. |
| OCT languageCode | 1.3.6.1.4.1.2.6.159.201.5.1.9 | OCTET STRING | read-only | The language code for this PET event. |
| STR localTimeStamp | 1.3.6.1.4.1.2.6.159.201.5.1.10 | DisplayString | read-only | The local time stamp of this PET event. |
| STR manufacturerId | 1.3.6.1.4.1.2.6.159.201.5.1.11 | DisplayString | read-only | The manufacturer ID for the source of the PET event. |
| OCT oemCustomField | 1.3.6.1.4.1.2.6.159.201.5.1.12 | OCTET STRING | read-only | The value for the OEM customer field of this PET event. |
| OCT offset | 1.3.6.1.4.1.2.6.159.201.5.1.13 | OCTET STRING | read-only | The offset for this PET event. |
| OCT sensorDevice | 1.3.6.1.4.1.2.6.159.201.5.1.14 | OCTET STRING | read-only | The sensor device for this PET event. |
| OCT sensorNumber | 1.3.6.1.4.1.2.6.159.201.5.1.15 | OCTET STRING | read-only | The sensor number for this PET event. |
| OCT sensorType | 1.3.6.1.4.1.2.6.159.201.5.1.16 | OCTET STRING | read-only | The sensor type for this PET event. |
| I32 sequenceId | 1.3.6.1.4.1.2.6.159.201.5.1.17 | Integer32 | read-only | The sequence ID for this PET event. |
| I32 systemId | 1.3.6.1.4.1.2.6.159.201.5.1.18 | Integer32 | read-only | The system ID for this PET event. |
| OCT trapSourceType | 1.3.6.1.4.1.2.6.159.201.5.1.19 | OCTET STRING | read-only | The trap source type for this PET event. |
| I32 utcOffset | 1.3.6.1.4.1.2.6.159.201.5.1.20 | Integer32 | read-only | The UTC offset for this PET event. |
| petEnvironmental | 1.3.6.1.4.1.2.6.159.201.5.2 | |||
| petEnvironmentalSensor | 1.3.6.1.4.1.2.6.159.201.5.2.1 | |||
| NTF sensorCaseIntrusion | 1.3.6.1.4.1.2.6.159.201.5.2.1.1 | A sensor has detected a case intrusion. | ||
| NTF sensorCurrent | 1.3.6.1.4.1.2.6.159.201.5.2.1.2 | A sensor has detected a current change. | ||
| NTF sensorFan | 1.3.6.1.4.1.2.6.159.201.5.2.1.3 | A sensor has detected a fan change. | ||
| NTF sensorPowerSupply | 1.3.6.1.4.1.2.6.159.201.5.2.1.4 | A sensor has detected a power supply change. | ||
| NTF sensorTemperature | 1.3.6.1.4.1.2.6.159.201.5.2.1.5 | A sensor has detected a temperature change. | ||
| NTF sensorVoltage | 1.3.6.1.4.1.2.6.159.201.5.2.1.6 | A sensor has detected a voltage change. | ||
| firmware | 1.3.6.1.4.1.2.6.159.201.5.3 | |||
| bios | 1.3.6.1.4.1.2.6.159.201.5.3.1 | |||
| NTF progress | 1.3.6.1.4.1.2.6.159.201.5.3.1.1 | The progress of the BIOS has changed. | ||
| hardware | 1.3.6.1.4.1.2.6.159.201.5.4 | |||
| NTF cableInterconnect | 1.3.6.1.4.1.2.6.159.201.5.4.1 | The cable/interconnect hardware has generated an event. | ||
| NTF drivebay | 1.3.6.1.4.1.2.6.159.201.5.4.2 | The monitor drivebay hardware has generated an event. | ||
| NTF moduleBoard | 1.3.6.1.4.1.2.6.159.201.5.4.3 | The monitor module/board hardware has generated an event. | ||
| NTF monitorAsicIc | 1.3.6.1.4.1.2.6.159.201.5.4.4 | The monitor ASIC/IC hardware has generated an event. | ||
| NTF network | 1.3.6.1.4.1.2.6.159.201.5.4.5 | The network hardware has generated an event. | ||
| NTF watchdog1 | 1.3.6.1.4.1.2.6.159.201.5.4.6 | The hardware has generated a watchdog 1 event. | ||
| NTF watchdog2 | 1.3.6.1.4.1.2.6.159.201.5.4.7 | The hardware has generated a watchdog 2 event. | ||
| petFamilySystem | 1.3.6.1.4.1.2.6.159.201.5.5 | |||
| petFamilySystemOs | 1.3.6.1.4.1.2.6.159.201.5.5.1 | |||
| NTF petFamilySystemOsBoot | 1.3.6.1.4.1.2.6.159.201.5.5.1.1 | The operating system on the host has booted. | ||
| petFamilySystemOsOperation | 1.3.6.1.4.1.2.6.159.201.5.5.1.2 | |||
| NTF heartbeat | 1.3.6.1.4.1.2.6.159.201.5.5.1.2.1 | The operating system has generated a heartbeat event. | ||
| storageFamily | 1.3.6.1.4.1.2.6.159.201.6 | |||
| serveRaidController | 1.3.6.1.4.1.2.6.159.201.6.1 | |||
| physicalDrive | 1.3.6.1.4.1.2.6.159.201.6.1.1 | |||
| NTF vendorUnsupported | 1.3.6.1.4.1.2.6.159.201.6.1.1.1 | The vendor for this physical drive is unsupported. | ||
| state | 1.3.6.1.4.1.2.6.159.201.6.1.2 | |||
| NTF notFound | 1.3.6.1.4.1.2.6.159.201.6.1.2.1 | No controllers were found in this system. | ||
| directorTrapsConformance | 1.3.6.1.4.1.2.6.159.201.100 | |||
| directorTrapsGroups | 1.3.6.1.4.1.2.6.159.201.100.1 | |||
| directorTrapsGroup | 1.3.6.1.4.1.2.6.159.201.100.1.1 | The objects group for objects defined in this module. | ||
| directorNotificationsGroup | 1.3.6.1.4.1.2.6.159.201.100.1.2 | The notification group for notifications defined in this module. | ||
| directorTrapsCompliances | 1.3.6.1.4.1.2.6.159.201.100.2 | |||
| directorTrapsCompliance | 1.3.6.1.4.1.2.6.159.201.100.2.1 | The compliance statement for this module. | ||
| description | 1.3.6.1.4.1.2.6.159.202 | |||
| STR trapType | 1.3.6.1.4.1.2.6.159.202.1 | SnmpAdminString | read-only | The type of the event. |
| STR trapSeverity | 1.3.6.1.4.1.2.6.159.202.2 | SnmpAdminString | read-only | The severity of the event. |
| STR trapSenderName | 1.3.6.1.4.1.2.6.159.202.3 | SnmpAdminString | read-only | The system name from which the event was sent. |
| STR trapManagedObjectName | 1.3.6.1.4.1.2.6.159.202.4 | SnmpAdminString | read-only | The system name for which the event was generated. |
| STR trapText | 1.3.6.1.4.1.2.6.159.202.5 | SnmpAdminString | read-only | Text associated with the event. |
| STR trapCategory | 1.3.6.1.4.1.2.6.159.202.6 | SnmpAdminString | read-only | The category of the event. |
| details | 1.3.6.1.4.1.2.6.159.9696 | |||
| OCT char | 1.3.6.1.4.1.2.6.159.9696.1 | OCTET STRING | read-only | Eight bit unsigned event detail. |
| I32 short | 1.3.6.1.4.1.2.6.159.9696.2 | Integer32 | read-only | Sixteen bit signed event detail. |
| I32 int | 1.3.6.1.4.1.2.6.159.9696.3 | Integer32 | read-only | Thirty-two bit signed event detail. |
| STR long | 1.3.6.1.4.1.2.6.159.9696.4 | DisplayString | read-only | Sixty-four bit signed event detail. |
| T/F boolean | 1.3.6.1.4.1.2.6.159.9696.5 | TruthValue | read-only | Thirty-two bit unsigned event detail. |
| STR float | 1.3.6.1.4.1.2.6.159.9696.6 | DisplayString | read-only | Thirty-two bit decimal pointed event detail. |
| STR double | 1.3.6.1.4.1.2.6.159.9696.7 | DisplayString | read-only | Sixty-four bit decimal pointed event detail. |
| STR octet | 1.3.6.1.4.1.2.6.159.9696.8 | DisplayString | read-only | A string of bytes holding an event detail. |
| STR string | 1.3.6.1.4.1.2.6.159.9696.9 | SnmpAdminString | read-only | A string of unicode chars (normal text) holding an event detail. |
| STR dateTime | 1.3.6.1.4.1.2.6.159.9696.10 | DisplayString | read-only | Date and time since 1/1970 as an event detail. |
| STR uniChar | 1.3.6.1.4.1.2.6.159.9696.11 | DisplayString | read-only | A unicode char holding an event detail. |
| STR byte | 1.3.6.1.4.1.2.6.159.9696.12 | DisplayString | read-only | One byte holding an event detail. |
RFC description
Provides IBM Director event-to-trap conversion for system management and alerting.
Start monitoring System managed by IBM Director (Event Action Plan threshold alerts) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.