All MIBs › IANA-MAU-MIB
Organization: IANA
Last Updated: 2024-04-02
Category: Network Interfaces, Textual Conventions and Registries
Description:
Defines dot3MauType object identities and textual conventions for Ethernet medium attachment unit (MAU) types used in the MAU-MIB.
Imported Objects
From SNMPv2-SMI
| MODULE-IDENTITY | |
| OBJECT-IDENTITY | |
| mib-2 |
From SNMPv2-TC
| TEXTUAL-CONVENTION |
What Is IANA-MAU-MIB?
IANA-MAU-MIB is an IETF/IANA-maintained companion module to the standard MAU-MIB, defining dot3MauType object identities and textual conventions (IANAifMauListBits, IANAifMauMediaAvailable, IANAifMauAutoNegCapBits, IANAifJackType) that enumerate Ethernet medium attachment unit (MAU) types, media availability states, auto-negotiation capability bits, and jack types. It contains no operational data objects itself; it exists purely to standardize the enumerated values used by the MAU-MIB's ifMauTypeListBits, ifMauMediaAvailable, ifMauAutoNegCapabilityBits/ifMauAutoNegCapAdvertisedBits/ifMauAutoNegCapReceivedBits, and ifJackType objects. Because it is a shared textual-convention module, it has no direct hardware/software status monitoring role of its own, but it underpins how the MAU-MIB reports physical-layer link type and auto-negotiation status across virtually all Ethernet-capable devices. It is a hard dependency of the standard MAU-MIB (RFC 4836) and any vendor MIB that reuses its conventions. It applies generically to any Ethernet interface hardware on any managed network device, since MAU type identification is a universal Ethernet management need. Engineers can download the IANA-MAU-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in IANA-MAU-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- vendor-neutral, standards-based MIB, not tied to a specific manufacturer
- any Ethernet-capable network device
Monitoring Examples
This is a textual-convention module with no runtime data objects (sample_objects is empty), so there is no concrete monitoring scenario against it directly; it is imported by the standard MAU-MIB to give meaning to values reported for objects like ifMauTypeListBits and ifJackType on real Ethernet interfaces.
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| dot3MauType | 1.3.6.1.2.1.26.4 | |||
| dot3MauTypeAUI | 1.3.6.1.2.1.26.4.1 | no internal MAU, view from AUI | ||
| dot3MauType10Base5 | 1.3.6.1.2.1.26.4.2 | thick coax MAU | ||
| dot3MauTypeFoirl | 1.3.6.1.2.1.26.4.3 | FOIRL MAU | ||
| dot3MauType10Base2 | 1.3.6.1.2.1.26.4.4 | thin coax MAU | ||
| dot3MauType10BaseT | 1.3.6.1.2.1.26.4.5 | UTP MAU. Note that it is strongly recommended that agents return either dot3MauType10BaseTHD or dot3MauType10BaseTFD if the duplex mode is known. However, management applications should be prepared to receive this MAU type value from older agent implementations. | ||
| dot3MauType10BaseFP | 1.3.6.1.2.1.26.4.6 | passive fiber MAU | ||
| dot3MauType10BaseFB | 1.3.6.1.2.1.26.4.7 | sync fiber MAU | ||
| dot3MauType10BaseFL | 1.3.6.1.2.1.26.4.8 | async fiber MAU. Note that it is strongly recommended that agents return either dot3MauType10BaseFLHD or dot3MauType10BaseFLFD if the duplex mode is known. However, management applications should be prepared to receive this MAU type value from older agent implementations. | ||
| dot3MauType10Broad36 | 1.3.6.1.2.1.26.4.9 | broadband DTE MAU. Note that 10BROAD36 MAUs can be attached to interfaces but not to repeaters. | ||
| dot3MauType10BaseTHD | 1.3.6.1.2.1.26.4.10 | UTP MAU, half duplex mode | ||
| dot3MauType10BaseTFD | 1.3.6.1.2.1.26.4.11 | UTP MAU, full duplex mode | ||
| dot3MauType10BaseFLHD | 1.3.6.1.2.1.26.4.12 | async fiber MAU, half duplex mode | ||
| dot3MauType10BaseFLFD | 1.3.6.1.2.1.26.4.13 | async fiber MAU, full duplex mode | ||
| dot3MauType100BaseT4 | 1.3.6.1.2.1.26.4.14 | 4 pair category 3 UTP | ||
| dot3MauType100BaseTXHD | 1.3.6.1.2.1.26.4.15 | 2 pair category 5 UTP, half duplex mode | ||
| dot3MauType100BaseTXFD | 1.3.6.1.2.1.26.4.16 | 2 pair category 5 UTP, full duplex mode | ||
| dot3MauType100BaseFXHD | 1.3.6.1.2.1.26.4.17 | X fiber over PMT, half duplex mode | ||
| dot3MauType100BaseFXFD | 1.3.6.1.2.1.26.4.18 | X fiber over PMT, full duplex mode | ||
| dot3MauType100BaseT2HD | 1.3.6.1.2.1.26.4.19 | 2 pair category 3 UTP, half duplex mode | ||
| dot3MauType100BaseT2FD | 1.3.6.1.2.1.26.4.20 | 2 pair category 3 UTP, full duplex mode | ||
| dot3MauType1000BaseXHD | 1.3.6.1.2.1.26.4.21 | PCS/PMA, unknown PMD, half duplex mode | ||
| dot3MauType1000BaseXFD | 1.3.6.1.2.1.26.4.22 | PCS/PMA, unknown PMD, full duplex mode | ||
| dot3MauType1000BaseLXHD | 1.3.6.1.2.1.26.4.23 | Fiber over long-wavelength laser, half duplex mode | ||
| dot3MauType1000BaseLXFD | 1.3.6.1.2.1.26.4.24 | Fiber over long-wavelength laser, full duplex mode | ||
| dot3MauType1000BaseSXHD | 1.3.6.1.2.1.26.4.25 | Fiber over short-wavelength laser, half duplex mode | ||
| dot3MauType1000BaseSXFD | 1.3.6.1.2.1.26.4.26 | Fiber over short-wavelength laser, full duplex mode | ||
| dot3MauType1000BaseCXHD | 1.3.6.1.2.1.26.4.27 | Copper over 150-Ohm balanced cable, half duplex mode | ||
| dot3MauType1000BaseCXFD | 1.3.6.1.2.1.26.4.28 | Copper over 150-Ohm balanced cable, full duplex mode | ||
| dot3MauType1000BaseTHD | 1.3.6.1.2.1.26.4.29 | Four-pair Category 5 UTP, half duplex mode | ||
| dot3MauType1000BaseTFD | 1.3.6.1.2.1.26.4.30 | Four-pair Category 5 UTP, full duplex mode | ||
| dot3MauType10GigBaseX | 1.3.6.1.2.1.26.4.31 | X PCS/PMA, unknown PMD. | ||
| dot3MauType10GigBaseLX4 | 1.3.6.1.2.1.26.4.32 | X fiber over WWDM optics | ||
| dot3MauType10GigBaseR | 1.3.6.1.2.1.26.4.33 | R PCS/PMA, unknown PMD. | ||
| dot3MauType10GigBaseER | 1.3.6.1.2.1.26.4.34 | R fiber over 1550 nm optics | ||
| dot3MauType10GigBaseLR | 1.3.6.1.2.1.26.4.35 | R fiber over 1310 nm optics | ||
| dot3MauType10GigBaseSR | 1.3.6.1.2.1.26.4.36 | R fiber over 850 nm optics | ||
| dot3MauType10GigBaseW | 1.3.6.1.2.1.26.4.37 | W PCS/PMA, unknown PMD. | ||
| dot3MauType10GigBaseEW | 1.3.6.1.2.1.26.4.38 | W fiber over 1550 nm optics | ||
| dot3MauType10GigBaseLW | 1.3.6.1.2.1.26.4.39 | W fiber over 1310 nm optics | ||
| dot3MauType10GigBaseSW | 1.3.6.1.2.1.26.4.40 | W fiber over 850 nm optics | ||
| dot3MauType10GigBaseCX4 | 1.3.6.1.2.1.26.4.41 | X copper over 8 pair 100-Ohm balanced cable | ||
| dot3MauType2BaseTL | 1.3.6.1.2.1.26.4.42 | Voice grade UTP copper, up to 2700m, optional PAF | ||
| dot3MauType10PassTS | 1.3.6.1.2.1.26.4.43 | Voice grade UTP copper, up to 750m, optional PAF | ||
| dot3MauType100BaseBX10D | 1.3.6.1.2.1.26.4.44 | One single-mode fiber OLT, long wavelength, 10km | ||
| dot3MauType100BaseBX10U | 1.3.6.1.2.1.26.4.45 | One single-mode fiber ONU, long wavelength, 10km | ||
| dot3MauType100BaseLX10 | 1.3.6.1.2.1.26.4.46 | Two single-mode fibers, long wavelength, 10km | ||
| dot3MauType1000BaseBX10D | 1.3.6.1.2.1.26.4.47 | One single-mode fiber OLT, long wavelength, 10km | ||
| dot3MauType1000BaseBX10U | 1.3.6.1.2.1.26.4.48 | One single-mode fiber ONU, long wavelength, 10km | ||
| dot3MauType1000BaseLX10 | 1.3.6.1.2.1.26.4.49 | Two sigle-mode fiber, long wavelength, 10km | ||
| dot3MauType1000BasePX10D | 1.3.6.1.2.1.26.4.50 | One single-mode fiber EPON OLT, 10km | ||
| dot3MauType1000BasePX10U | 1.3.6.1.2.1.26.4.51 | One single-mode fiber EPON ONU, 10km | ||
| dot3MauType1000BasePX20D | 1.3.6.1.2.1.26.4.52 | One single-mode fiber EPON OLT, 20km | ||
| dot3MauType1000BasePX20U | 1.3.6.1.2.1.26.4.53 | One single-mode fiber EPON ONU, 20km | ||
| dot3MauType10GbaseT | 1.3.6.1.2.1.26.4.54 | Four-pair Category 6A or better, full duplex mode only | ||
| dot3MauType10GbaseLRM | 1.3.6.1.2.1.26.4.55 | R multimode fiber over 1310 nm optics | ||
| dot3MauType1000baseKX | 1.3.6.1.2.1.26.4.56 | X backplane, full duplex mode only | ||
| dot3MauType10GbaseKX4 | 1.3.6.1.2.1.26.4.57 | 4 lane X backplane, full duplex mode only | ||
| dot3MauType10GbaseKR | 1.3.6.1.2.1.26.4.58 | R backplane, full duplex mode only | ||
| dot3MauType10G1GbasePRXD1 | 1.3.6.1.2.1.26.4.59 | One single-mode fiber asymmetric-rate EPON OLT, supporting low power budget (PRX10) | ||
| dot3MauType10G1GbasePRXD2 | 1.3.6.1.2.1.26.4.60 | One single-mode fiber asymmetric-rate EPON OLT, supporting medium power budget (PRX20) | ||
| dot3MauType10G1GbasePRXD3 | 1.3.6.1.2.1.26.4.61 | One single-mode fiber asymmetric-rate EPON OLT, supporting high power budget (PRX30) | ||
| dot3MauType10G1GbasePRXU1 | 1.3.6.1.2.1.26.4.62 | One single-mode fiber asymmetric-rate EPON ONU, supporting low power budget (PRX10) | ||
| dot3MauType10G1GbasePRXU2 | 1.3.6.1.2.1.26.4.63 | One single-mode fiber asymmetric-rate EPON ONU, supporting medium power budget (PRX20) | ||
| dot3MauType10G1GbasePRXU3 | 1.3.6.1.2.1.26.4.64 | One single-mode fiber asymmetric-rate EPON ONU, supporting high power budget (PRX30) | ||
| dot3MauType10GbasePRD1 | 1.3.6.1.2.1.26.4.65 | One single-mode fiber symmetric-rate EPON OLT, supporting low power budget (PR10) | ||
| dot3MauType10GbasePRD2 | 1.3.6.1.2.1.26.4.66 | One single-mode fiber symmetric-rate EPON OLT, supporting medium power budget (PR20) | ||
| dot3MauType10GbasePRD3 | 1.3.6.1.2.1.26.4.67 | One single-mode fiber symmetric-rate EPON OLT, supporting high power budget (PR30) | ||
| dot3MauType10GbasePRU1 | 1.3.6.1.2.1.26.4.68 | One single-mode fiber symmetric-rate EPON ONU, supporting low and medium power budget (PR10 and PR20) | ||
| dot3MauType10GbasePRU3 | 1.3.6.1.2.1.26.4.69 | One single-mode fiber symmetric-rate EPON ONU, supporting high power budget (PR30) | ||
| dot3MauType40GbaseKR4 | 1.3.6.1.2.1.26.4.70 | 40GBASE-R PCS/PMA over an electrical backplane | ||
| dot3MauType40GbaseCR4 | 1.3.6.1.2.1.26.4.71 | 40GBASE-R PCS/PMA over 4 lane shielded copper balanced cable | ||
| dot3MauType40GbaseSR4 | 1.3.6.1.2.1.26.4.72 | 40GBASE-R PCS/PMA over 4 lane multimode fiber | ||
| dot3MauType40GbaseFR | 1.3.6.1.2.1.26.4.73 | 40GBASE-R PCS/PMA over single mode fiber | ||
| dot3MauType40GbaseLR4 | 1.3.6.1.2.1.26.4.74 | 40GBASE-R PCS/PMA over 4 WDM lane single mode fiber | ||
| dot3MauType100GbaseCR10 | 1.3.6.1.2.1.26.4.75 | 100GBASE-R PCS/PMA over 10 lane shielded copper balanced cable | ||
| dot3MauType100GbaseSR10 | 1.3.6.1.2.1.26.4.76 | 100GBASE-R PCS/PMA over 10 lane multimode fiber | ||
| dot3MauType100GbaseLR4 | 1.3.6.1.2.1.26.4.77 | 100GBASE-R PCS/PMA over 4 WDM lane single mode fiber, long reach | ||
| dot3MauType100GbaseER4 | 1.3.6.1.2.1.26.4.78 | 100GBASE-R PCS/PMA over 4 WDM lane single mode fiber PMD, extended reach | ||
| dot3MauType1000baseT1 | 1.3.6.1.2.1.26.4.79 | 1000BASE-T1 single balanced twisted-pair copper cabling PHY | ||
| dot3MauType1000basePX30D | 1.3.6.1.2.1.26.4.80 | One single-mode fiber EPON OLT, 20km, 1:32 split ratio | ||
| dot3MauType1000basePX30U | 1.3.6.1.2.1.26.4.81 | One single-mode fiber EPON ONU, 20km, 1:32 split ratio | ||
| dot3MauType1000basePX40D | 1.3.6.1.2.1.26.4.82 | One single-mode fiber EPON OLT, 20km, 1:64 split ratio | ||
| dot3MauType1000basePX40U | 1.3.6.1.2.1.26.4.83 | One single-mode fiber EPON ONU, 20km, 1:64 split ratio | ||
| dot3MauType10G1GbasePRXD4 | 1.3.6.1.2.1.26.4.84 | One single-mode fiber asymmetric-rate EPON OLT, supporting extended power budget (PRX40) | ||
| dot3MauType10G1GbasePRXU4 | 1.3.6.1.2.1.26.4.85 | One single-mode fiber asymmetric-rate EPON ONU, supporting extended power budget (PRX40) | ||
| dot3MauType10GbasePRD4 | 1.3.6.1.2.1.26.4.86 | One single-mode fiber symmetric-rate EPON OLT, supporting extended power budget (PR40) | ||
| dot3MauType10GbasePRU4 | 1.3.6.1.2.1.26.4.87 | One single-mode fiber symmetric-rate EPON ONU, supporting extended power budget (PR40) | ||
| dot3MauType25GbaseCR | 1.3.6.1.2.1.26.4.88 | 25GBASE-R PCS/PMA over shielded balanced copper cable | ||
| dot3MauType25GbaseCRS | 1.3.6.1.2.1.26.4.89 | 25GBASE-R PCS/PMA over shielded balanced copper cable without RS-FEC | ||
| dot3MauType25GbaseKR | 1.3.6.1.2.1.26.4.90 | 25GBASE-R PCS/PMA over an electrical backplane | ||
| dot3MauType25GbaseKRS | 1.3.6.1.2.1.26.4.91 | 25GBASE-R PCS/PMA over an electrical backplane without RS-FEC | ||
| dot3MauType25GbaseR | 1.3.6.1.2.1.26.4.92 | 25GBASE-R PCS/PMA over undefined PMD | ||
| dot3MauType25GbaseSR | 1.3.6.1.2.1.26.4.93 | 25GBASE-R PCS/PMA over multimode fiber | ||
| dot3MauType25GbaseT | 1.3.6.1.2.1.26.4.94 | Four-pair twisted-pair balanced copper cabling | ||
| dot3MauType40GbaseER4 | 1.3.6.1.2.1.26.4.95 | 40GBASE-R PCS/PMA over 4 WDM lane single mode fiber | ||
| dot3MauType40GbaseR | 1.3.6.1.2.1.26.4.96 | 40GBASE-R PCS as over undefined PMA/PMD | ||
| dot3MauType40GbaseT | 1.3.6.1.2.1.26.4.97 | Four-pair twisted-pair balanced copper cabling | ||
| dot3MauType100GbaseCR4 | 1.3.6.1.2.1.26.4.98 | 100GBASE-R PCS/PMA over 4 lane shielded copper balanced cable | ||
| dot3MauType100GbaseKR4 | 1.3.6.1.2.1.26.4.99 | 100GBASE-R PCS/PMA over an electrical backplane | ||
| dot3MauType100GbaseKP4 | 1.3.6.1.2.1.26.4.100 | 100GBASE-P PCS/PMA over an electrical backplane PMD | ||
| dot3MauType100GbaseR | 1.3.6.1.2.1.26.4.101 | 100GBASE-R Multi-lane PCS over undefined PMA/PMD | ||
| dot3MauType100GbaseSR4 | 1.3.6.1.2.1.26.4.102 | 100GBASE-R PCS/PMA over 4 lane multimode fiber | ||
| dot3MauType2p5GigT | 1.3.6.1.2.1.26.4.103 | 2.5GBASE-T Four-pair twisted-pair balanced copper cabling PHY | ||
| dot3MauType5GigT | 1.3.6.1.2.1.26.4.104 | 5GBASE-T Four-pair twisted-pair balanced copper cabling PHY | ||
| dot3MauType100baseT1 | 1.3.6.1.2.1.26.4.105 | 100BASE-T1 Single balanced twisted-pair copper cabling PHY | ||
| dot3MauType1000baseRHA | 1.3.6.1.2.1.26.4.106 | 1000BASE-RHA Plastic optical fiber PHY | ||
| dot3MauType1000baseRHB | 1.3.6.1.2.1.26.4.107 | 1000BASE-RHB Plastic optical fiber PHY | ||
| dot3MauType1000baseRHC | 1.3.6.1.2.1.26.4.108 | 1000BASE-RHC Plastic optical fiber PHY | ||
| dot3MauType2p5GbaseKX | 1.3.6.1.2.1.26.4.109 | 2.5GBASE-X PMD over an electrical backplane | ||
| dot3MauType2p5GbaseX | 1.3.6.1.2.1.26.4.110 | 2.5GBASE-X PCS/PMA over undefined PMD | ||
| dot3MauType5GbaseKR | 1.3.6.1.2.1.26.4.111 | 5GBASE-KR PMD over an electrical backplane | ||
| dot3MauType5GbaseR | 1.3.6.1.2.1.26.4.112 | 5GBASE-R PCS/PMA over undefined PMD | ||
| dot3MauType10GpassXR | 1.3.6.1.2.1.26.4.113 | Coax cable distribution network PHY continuous downstream/burst mode upstream PHY | ||
| dot3MauType25GbaseLR | 1.3.6.1.2.1.26.4.114 | 25GBASE-R PCS/PMA over single-mode fiber PMD, with long reach | ||
| dot3MauType25GbaseER | 1.3.6.1.2.1.26.4.115 | 25GBASE-R PCS/PMA over single-mode fiber PMD, with extended reach | ||
| dot3MauType50GbaseR | 1.3.6.1.2.1.26.4.116 | 50GBASE-R Multi-lane PCS over undefined PMA/PMD | ||
| dot3MauType50GbaseCR | 1.3.6.1.2.1.26.4.117 | 50GBASE-R PCS/PMA over shielded copper balanced cable PMD | ||
| dot3MauType50GbaseKR | 1.3.6.1.2.1.26.4.118 | 50GBASE-R PCS/PMA over an electrical backplane PMD | ||
| dot3MauType50GbaseSR | 1.3.6.1.2.1.26.4.119 | 50GBASE-R PCS/PMA over multimode fiber PMD | ||
| dot3MauType50GbaseFR | 1.3.6.1.2.1.26.4.120 | 50GBASE-R PCS/PMA over single mode fiber PMD with reach up to at least 2 km | ||
| dot3MauType50GbaseLR | 1.3.6.1.2.1.26.4.121 | 50GBASE-R PCS/PMA over single mode fiber PMD with reach up to at least 10 km | ||
| dot3MauType50GbaseER | 1.3.6.1.2.1.26.4.122 | 50GBASE-R PCS/PMA over single-mode fiber PMD with reach up to at least 40 km | ||
| dot3MauType100GbaseCR2 | 1.3.6.1.2.1.26.4.123 | 100GBASE-R PCS/PMA over 2 lane shielded copper balanced cable PMD | ||
| dot3MauType100GbaseKR2 | 1.3.6.1.2.1.26.4.124 | 100GBASE-R PCS/PMA over an electrical backplane PMD | ||
| dot3MauType100GbaseSR2 | 1.3.6.1.2.1.26.4.125 | 100GBASE-R PCS/PMA over 2 lane multimode fiber PMD | ||
| dot3MauType100GbaseDR | 1.3.6.1.2.1.26.4.126 | 100GBASE-R PCS/PMA over single mode fiber PMD | ||
| dot3MauType200GbaseR | 1.3.6.1.2.1.26.4.127 | 200GBASE-R Multi-lane PCS over undefined PMA/PMD | ||
| dot3MauType200GbaseDR4 | 1.3.6.1.2.1.26.4.128 | 200GBASE-R PCS/PMA over 4-lane single-mode fiber PMD | ||
| dot3MauType200GbaseFR4 | 1.3.6.1.2.1.26.4.129 | 200GBASE-R PCS/PMA over 4 WDM lane single-mode fiber PMD with reach up to at least 2 km | ||
| dot3MauType200GbaseLR4 | 1.3.6.1.2.1.26.4.130 | 200GBASE-R PCS/PMA over 4 WDM lane single-mode fiber PMD with reach up to at least 10 km | ||
| dot3MauType200GbaseCR4 | 1.3.6.1.2.1.26.4.131 | 200GBASE-R PCS/PMA over 4 lane shielded copper balanced cable PMD | ||
| dot3MauType200GbaseKR4 | 1.3.6.1.2.1.26.4.132 | 200GBASE-R PCS/PMA over an electrical backplane PMD | ||
| dot3MauType200GbaseSR4 | 1.3.6.1.2.1.26.4.133 | 200GBASE-R PCS/PMA over 4 lane multimode fiber PMD | ||
| dot3MauType200GbaseER4 | 1.3.6.1.2.1.26.4.134 | 200GBASE-R PCS/PMA over 4 WDM lane single-mode fiber PMD with reach up to at least 40 km | ||
| dot3MauType400GbaseR | 1.3.6.1.2.1.26.4.135 | 400GBASE-R Multi-lane PCS over undefined PMA/PMD | ||
| dot3MauType400GbaseSR16 | 1.3.6.1.2.1.26.4.136 | 400GBASE-R PCS/PMA over 16-lane multimode fiber PMD | ||
| dot3MauType400GbaseDR4 | 1.3.6.1.2.1.26.4.137 | 400GBASE-R PCS/PMA over 4-lane single-mode fiber PMD | ||
| dot3MauType400GbaseFR8 | 1.3.6.1.2.1.26.4.138 | 400GBASE-R PCS/PMA over 8 WDM lane single-mode fiber PMD with reach up to at least 2 km | ||
| dot3MauType400GbaseLR8 | 1.3.6.1.2.1.26.4.139 | 400GBASE-R PCS/PMA over 8 WDM lane single-mode fiber PMD with reach up to at least 10 km | ||
| dot3MauType400GbaseER8 | 1.3.6.1.2.1.26.4.140 | 400GBASE-R PCS/PMA over 8 WDM lane single-mode fiber PMD with reach up to at least 40 km | ||
| dot3MauType10baseT1L | 1.3.6.1.2.1.26.4.141 | 10BASE-T1L Single balanced pair PHY | ||
| dot3MauType10baseT1SHD | 1.3.6.1.2.1.26.4.142 | 10BASE-T1S Single balanced pair PHY, half duplex mode | ||
| dot3MauType10baseT1SMD | 1.3.6.1.2.1.26.4.143 | 10BASE-T1S Single balanced pair PHY, multidrop mode | ||
| dot3MauType10baseT1SFD | 1.3.6.1.2.1.26.4.144 | 10BASE-T1S Single balanced pair PHY, full duplex mode | ||
| dot3MauType100GbaseFR1 | 1.3.6.1.2.1.26.4.145 | 100GBASE-R PCS/PMA over single-mode fiber PMD with reach up to at least 2 km | ||
| dot3MauType100GbaseLR1 | 1.3.6.1.2.1.26.4.146 | 100GBASE-R PCS/PMA over single-mode fiber PMD with reach up to at least 10 km | ||
| dot3MauType400GbaseFR4 | 1.3.6.1.2.1.26.4.147 | 400GBASE-R PCS/PMA over 4 WDM lane single-mode fiber PMD with reach up to at least 2 km | ||
| dot3MauType400GbaseLR46 | 1.3.6.1.2.1.26.4.148 | 400GBASE-R PCS/PMA over 4 WDM lane single-mode fiber PMD with reach up to at least 6 km | ||
| dot3MauType400GbaseSR8 | 1.3.6.1.2.1.26.4.149 | 400GBASE-R PCS/PMA over 8-lane multimode fiber PMD as specified in Clause 138 | ||
| dot3MauType400GbaseSR4p2 | 1.3.6.1.2.1.26.4.150 | 400GBASE-R PCS/PMA over 8-lane multimode fiber PMD as specified in Clause 150 | ||
| dot3MauType2p5GbaseT1 | 1.3.6.1.2.1.26.4.151 | Single balanced pair of conductors PHY as specified in Clause 149 | ||
| dot3MauType5GbaseT1 | 1.3.6.1.2.1.26.4.152 | Single balanced pair of conductors PHY as specified in Clause 149 | ||
| dot3MauType10GbaseT1 | 1.3.6.1.2.1.26.4.153 | Single balanced pair of conductors PHY as specified in Clause 149 | ||
| dot3MauType25G10GbasePQGD2 | 1.3.6.1.2.1.26.4.154 | One single mode fiber, 1 x 25.78125 GBd continuous transmission / 1 x 10.3125 GBd burst mode reception, medium power class, as specified in Clause 141 | ||
| dot3MauType25G10GbasePQGD3 | 1.3.6.1.2.1.26.4.155 | One single mode fiber, 1 x 25.78125 GBd continuous transmission / 1 x 10.3125 GBd burst mode reception, high power class, as specified in Clause 141 | ||
| dot3MauType25G10GbasePQGU2 | 1.3.6.1.2.1.26.4.156 | One single mode fiber, 1 x 25.78125 GBd continuous reception / 1 x 10.3125 GBd burst mode transmission, medium power class, as specified in Clause 141 | ||
| dot3MauType25G10GbasePQGU3 | 1.3.6.1.2.1.26.4.157 | One single mode fiber, 1 x 25.78125 GBd continuous reception / 1 x 10.3125 GBd burst mode transmission, high power class, as specified in Clause 141 | ||
| dot3MauType25G10GbasePQXD2 | 1.3.6.1.2.1.26.4.158 | One single mode fiber, 1 x 25.78125 GBd continuous transmission / 1 x 10.3125 GBd burst mode reception, medium power class, as specified in Clause 141 | ||
| dot3MauType25G10GbasePQXD3 | 1.3.6.1.2.1.26.4.159 | One single mode fiber, 1 x 25.78125 GBd continuous transmission / 1 x 10.3125 GBd burst mode reception, high power class, as specified in Clause 141 | ||
| dot3MauType25G10GbasePQXU2 | 1.3.6.1.2.1.26.4.160 | One single mode fiber, 1 x 25.78125 GBd continuous reception / 1 x 10.3125 GBd burst mode transmission, medium power class, as specified in Clause 141 | ||
| dot3MauType25G10GbasePQXU3 | 1.3.6.1.2.1.26.4.161 | One single mode fiber, 1 x 25.78125 GBd continuous reception / 1 x 10.3125 GBd burst mode transmission, high power class, as specified in Clause 141 | ||
| dot3MauType25GbasePQGD2 | 1.3.6.1.2.1.26.4.162 | One single mode fiber, 1 x 25.78125 GBd continuous transmission / 1 x 25.78125 GBd burst mode reception, medium power class, as specified in Clause 141 | ||
| dot3MauType25GbasePQGD3 | 1.3.6.1.2.1.26.4.163 | One single mode fiber, 1 x 25.78125 GBd continuous transmission / 1 x 25.78125 GBd burst mode reception, high power class, as specified in Clause 141 | ||
| dot3MauType25GbasePQGU2 | 1.3.6.1.2.1.26.4.164 | One single mode fiber, 1 x 25.78125 GBd continuous reception / 1 x 25.78125 GBd burst mode transmission, medium power class, as specified in Clause 141 | ||
| dot3MauType25GbasePQGU3 | 1.3.6.1.2.1.26.4.165 | One single mode fiber, 1 x 25.78125 GBd continuous reception / 1 x 25.78125 GBd burst mode transmission, high power class, as specified in Clause 141 | ||
| dot3MauType25GbasePQXD2 | 1.3.6.1.2.1.26.4.166 | One single mode fiber, 1 x 25.78125 GBd continuous transmission / 1 x 25.78125 GBd burst mode reception, medium power class, as specified in Clause 141 | ||
| dot3MauType25GbasePQXD3 | 1.3.6.1.2.1.26.4.167 | One single mode fiber, 1 x 25.78125 GBd continuous transmission / 1 x 25.78125 GBd burst mode reception, high power class, as specified in Clause 141 | ||
| dot3MauType25GbasePQXU2 | 1.3.6.1.2.1.26.4.168 | One single mode fiber, 1 x 25.78125 GBd continuous reception / 1 x 25.78125 GBd burst mode transmission, medium power class, as specified in Clause 141 | ||
| dot3MauType25GbasePQXU3 | 1.3.6.1.2.1.26.4.169 | One single mode fiber, 1 x 25.78125 GBd continuous reception / 1 x 25.78125 GBd burst mode transmission, high power class, as specified in Clause 141 | ||
| dot3MauType50G10GbasePQGD2 | 1.3.6.1.2.1.26.4.170 | One single mode fiber, 2 x 25.78125 GBd continuous transmission / 1 x 10.3125 GBd burst mode reception, medium power class, as specified in Clause 141 | ||
| dot3MauType50G10GbasePQGD3 | 1.3.6.1.2.1.26.4.171 | One single mode fiber, 2 x 25.78125 GBd continuous transmission / 1 x 10.3125 GBd burst mode reception, high power class, as specified in Clause 141 | ||
| dot3MauType50G10GbasePQGU2 | 1.3.6.1.2.1.26.4.172 | One single mode fiber, 2 x 25.78125 GBd continuous reception / 1 x 10.3125 GBd burst mode transmission, medium power class, as specified in Clause 141 | ||
| dot3MauType50G10GbasePQGU3 | 1.3.6.1.2.1.26.4.173 | One single mode fiber, 2 x 25.78125 GBd continuous reception / 1 x 10.3125 GBd burst mode transmission, high power class, as specified in Clause 141 | ||
| dot3MauType50G10GbasePQXD2 | 1.3.6.1.2.1.26.4.174 | One single mode fiber, 2 x 25.78125 GBd continuous transmission / 1 x 10.3125 GBd burst mode reception, medium power class, as specified in Clause 141 | ||
| dot3MauType50G10GbasePQXD3 | 1.3.6.1.2.1.26.4.175 | One single mode fiber, 2 x 25.78125 GBd continuous transmission / 1 x 10.3125 GBd burst mode reception, high power class, as specified in Clause 141 | ||
| dot3MauType50G10GbasePQXU2 | 1.3.6.1.2.1.26.4.176 | One single mode fiber, 2 x 25.78125 GBd continuous reception / 1 x 10.3125 GBd burst mode transmission, medium power class, as specified in Clause 141 | ||
| dot3MauType50G10GbasePQXU3 | 1.3.6.1.2.1.26.4.177 | One single mode fiber, 2 x 25.78125 GBd continuous reception / 1 x 10.3125 GBd burst mode transmission, high power class, as specified in Clause 141 | ||
| dot3MauType50G25GbasePQGD2 | 1.3.6.1.2.1.26.4.178 | One single mode fiber, 2 x 25.78125 GBd continuous transmission / 1 x 25.78125 GBd burst mode reception, medium power class, as specified in Clause 141 | ||
| dot3MauType50G25GbasePQGD3 | 1.3.6.1.2.1.26.4.179 | One single mode fiber, 2 x 25.78125 GBd continuous transmission / 1 x 25.78125 GBd burst mode reception, high power class, as specified in Clause 141 | ||
| dot3MauType50G25GbasePQGU2 | 1.3.6.1.2.1.26.4.180 | One single mode fiber, 2 x 25.78125 GBd continuous reception / 1 x 25.78125 GBd burst mode transmission, medium power class, as specified in Clause 141 | ||
| dot3MauType50G25GbasePQGU3 | 1.3.6.1.2.1.26.4.181 | One single mode fiber, 2 x 25.78125 GBd continuous reception / 1 x 25.78125 GBd burst mode transmission, high power class, as specified in Clause 141 | ||
| dot3MauType50G25GbasePQXD2 | 1.3.6.1.2.1.26.4.182 | One single mode fiber, 2 x 25.78125 GBd continuous transmission / 1 x 25.78125 GBd burst mode reception, medium power class, as specified in Clause 141 | ||
| dot3MauType50G25GbasePQXD3 | 1.3.6.1.2.1.26.4.183 | One single mode fiber, 2 x 25.78125 GBd continuous transmission / 1 x 25.78125 GBd burst mode reception, high power class, as specified in Clause 141 | ||
| dot3MauType50G25GbasePQXU2 | 1.3.6.1.2.1.26.4.184 | One single mode fiber, 2 x 25.78125 GBd continuous reception / 1 x 25.78125 GBd burst mode transmission, medium power class, as specified in Clause 141 | ||
| dot3MauType50G25GbasePQXU3 | 1.3.6.1.2.1.26.4.185 | One single mode fiber, 2 x 25.78125 GBd continuous reception / 1 x 25.78125 GBd burst mode transmission, high power class, as specified in Clause 141 | ||
| dot3MauType50GbasePQGD2 | 1.3.6.1.2.1.26.4.186 | One single mode fiber, 2 x 25.78125 GBd continuous transmission / 2 x 25.78125 GBd burst mode reception, medium power class, as specified in Clause 141 | ||
| dot3MauType50GbasePQGD3 | 1.3.6.1.2.1.26.4.187 | One single mode fiber, 2 x 25.78125 GBd continuous transmission / 2 x 25.78125 GBd burst mode reception, high power class, as specified in Clause 141 | ||
| dot3MauType50GbasePQGU2 | 1.3.6.1.2.1.26.4.188 | One single mode fiber, 2 x 25.78125 GBd continuous reception / 2 x 25.78125 GBd burst mode transmission, medium power class, as specified in Clause 141 | ||
| dot3MauType50GbasePQGU3 | 1.3.6.1.2.1.26.4.189 | One single mode fiber, 2 x 25.78125 GBd continuous reception / 2 x 25.78125 GBd burst mode transmission, high power class, as specified in Clause 141 | ||
| dot3MauType50GbasePQXD2 | 1.3.6.1.2.1.26.4.190 | One single mode fiber, 2 x 25.78125 GBd continuous transmission / 2 x 25.78125 GBd burst mode reception, medium power class, as specified in Clause 141 | ||
| dot3MauType50GbasePQXD3 | 1.3.6.1.2.1.26.4.191 | One single mode fiber, 2 x 25.78125 GBd continuous transmission / 2 x 25.78125 GBd burst mode reception, high power class, as specified in Clause 141 | ||
| dot3MauType50GbasePQXU2 | 1.3.6.1.2.1.26.4.192 | One single mode fiber, 2 x 25.78125 GBd continuous reception / 2 x 25.78125 GBd burst mode transmission, medium power class, as specified in Clause 141 | ||
| dot3MauType50GbasePQXU3 | 1.3.6.1.2.1.26.4.193 | One single mode fiber, 2 x 25.78125 GBd continuous reception / 2 x 25.78125 GBd burst mode transmission, high power class, as specified in Clause 141 | ||
| dot3MauType100GbaseZR | 1.3.6.1.2.1.26.4.194 | 100GBASE-R PCS/100GBASE-ZR PMA over a PMD with reach up to at least 80 km as specified in Clause 154 | ||
| dot3MauType10GbaseBR10D | 1.3.6.1.2.1.26.4.195 | One single-mode fiber OLT PHY supporting a distance of at least 10 km as specified in Clause 158 | ||
| dot3MauType10GbaseBR10U | 1.3.6.1.2.1.26.4.196 | One single-mode fiber ONU PHY supporting a distance of at least 10 km as specified in Clause 158 | ||
| dot3MauType10GbaseBR20D | 1.3.6.1.2.1.26.4.197 | One single-mode fiber OLT PHY supporting a distance of at least 20 km as specified in Clause 158 | ||
| dot3MauType10GbaseBR20U | 1.3.6.1.2.1.26.4.198 | One single-mode fiber ONU PHY supporting a distance of at least 20 km as specified in Clause 158 | ||
| dot3MauType10GbaseBR40D | 1.3.6.1.2.1.26.4.199 | One single-mode fiber OLT PHY supporting a distance of at least 40 km as specified in Clause 158 | ||
| dot3MauType10GbaseBR40U | 1.3.6.1.2.1.26.4.200 | One single-mode fiber ONU PHY supporting a distance of at least 40 km as specified in Clause 158 | ||
| dot3MauType25GbaseBR10D | 1.3.6.1.2.1.26.4.201 | One single-mode fiber OLT PHY supporting a distance of at least 10 km as specified in Clause 159 | ||
| dot3MauType25GbaseBR10U | 1.3.6.1.2.1.26.4.202 | One single-mode fiber ONU PHY supporting a distance of at least 10 km as specified in Clause 159 | ||
| dot3MauType25GbaseBR20D | 1.3.6.1.2.1.26.4.203 | One single-mode fiber OLT PHY supporting a distance of at least 20 km as specified in Clause 159 | ||
| dot3MauType25GbaseBR20U | 1.3.6.1.2.1.26.4.204 | One single-mode fiber ONU PHY supporting a distance of at least 20 km as specified in Clause 159 | ||
| dot3MauType25GbaseBR40D | 1.3.6.1.2.1.26.4.205 | One single-mode fiber OLT PHY supporting a distance of at least 40 km as specified in Clause 159 | ||
| dot3MauType25GbaseBR40U | 1.3.6.1.2.1.26.4.206 | One single-mode fiber ONU PHY supporting a distance of at least 40 km as specified in Clause 159 | ||
| dot3MauType50GbaseBR10D | 1.3.6.1.2.1.26.4.207 | One single-mode fiber OLT PHY supporting a distance of at least 10 km as specified in Clause 160 | ||
| dot3MauType50GbaseBR10U | 1.3.6.1.2.1.26.4.208 | One single-mode fiber ONU PHY supporting a distance of at least 10 km as specified in Clause 160 | ||
| dot3MauType50GbaseBR20D | 1.3.6.1.2.1.26.4.209 | One single-mode fiber OLT PHY supporting a distance of at least 20 km as specified in Clause 160 | ||
| dot3MauType50GbaseBR20U | 1.3.6.1.2.1.26.4.210 | One single-mode fiber ONU PHY supporting a distance of at least 20 km as specified in Clause 160 | ||
| dot3MauType50GbaseBR40D | 1.3.6.1.2.1.26.4.211 | One single-mode fiber OLT PHY supporting a distance of at least 40 km as specified in Clause 160 | ||
| dot3MauType50GbaseBR40U | 1.3.6.1.2.1.26.4.212 | One single-mode fiber ONU PHY supporting a distance of at least 40 km as specified in Clause 160 | ||
| dot3MauType2p5GbaseAU | 1.3.6.1.2.1.26.4.213 | Glass optical fiber PHY as specified in Clause 166 | ||
| dot3MauType5GbaseAU | 1.3.6.1.2.1.26.4.214 | Glass optical fiber PHY as specified in Clause 166 | ||
| dot3MauType10GbaseAU | 1.3.6.1.2.1.26.4.215 | Glass optical fiber PHY as specified in Clause 166 | ||
| dot3MauType25GbaseAU | 1.3.6.1.2.1.26.4.216 | Glass optical fiber PHY as specified in Clause 166 | ||
| dot3MauType50GbaseAU | 1.3.6.1.2.1.26.4.217 | Glass optical fiber PHY as specified in Clause 166 | ||
| dot3MauType25GbaseT1 | 1.3.6.1.2.1.26.4.218 | Single balanced pair of conductors PHY as specified in Clause 165 | ||
| dot3MauType400GbaseDR42 | 1.3.6.1.2.1.26.4.219 | 400GBASE-R PCS/PMA over 4 single-mode fibers in each direction PMD with reach up to at least 2 km as specified in Clause 124 | ||
| dot3MauType800GbaseCR8 | 1.3.6.1.2.1.26.4.220 | 800GBASE-R PCS/PMA over 8-lane shielded balanced copper cable PMD as specified in Clause 162 | ||
| dot3MauType800GbaseDR8 | 1.3.6.1.2.1.26.4.221 | 800GBASE-R PCS/PMA over 8 single-mode fibers in each direction PMD with reach up to at least 500 m as specified in Clause 124 | ||
| dot3MauType800GbaseDR82 | 1.3.6.1.2.1.26.4.222 | 800GBASE-R PCS/PMA over 8 single-mode fibers in each direction PMD with reach up to at least 2 km as specified in Clause 124 | ||
| dot3MauType800GbaseKR8 | 1.3.6.1.2.1.26.4.223 | 800GBASE-R PCS/PMA over an electrical backplane PMD as specified in Clause 163 | ||
| dot3MauType800GbaseR | 1.3.6.1.2.1.26.4.224 | Multi-lane PCS as specified in Clause 172 over undefined PMA/PMD | ||
| dot3MauType800GbaseSR8 | 1.3.6.1.2.1.26.4.225 | 800GBASE-R PCS/PMA over 8 multimode fibers in each direction PMD with reach up to at least 100 m as specified in Clause 167 | ||
| dot3MauType800GbaseVR8 | 1.3.6.1.2.1.26.4.226 | 800GBASE-R PCS/PMA over 8 multimode fibers in each direction PMD with reach up to at least 50 m as specified in Clause 167 | ||
| ianaMauMIB | 1.3.6.1.2.1.154 | This MIB module defines dot3MauType OBJECT-IDENTITIES and IANAifMauListBits, IANAifMauMediaAvailable, IANAifMauAutoNegCapBits, and IANAifJackType TEXTUAL-CONVENTIONs, specifying enumerated values of the ifMauTypeListBits, ifMauMediaAvailable / rpMauMediaAvailable, ifMauAutoNegCapabilityBits / ifMauAutoNegCapAdvertisedBits / ifMauAutoNegCapReceivedBits and ifJackType / rpJackType objects respectively, defined in the MAU-MIB. It is intended that each new MAU type, Media Availability state, Auto Negotiation capability and/or Jack type defined by the IEEE 802.3 working group and approved for publication in a revision of IEEE Std 802.3 will be added to this MIB module, provided that it is suitable for being managed by the base objects in the MAU-MIB. An Expert Review, as defined in RFC 2434 [RFC2434], is REQUIRED for such additions. The following reference is used throughout this MIB module: [IEEE802.3] refers to IEEE Std 802.3-2022: 'IEEE Standard for Ethernet'. This reference should be updated as appropriate when new MAU types, Media Availability states, Auto Negotiation capabilities, and/or Jack types are added to this MIB module. Copyright (C) The IETF Trust (2007). The initial version of this MIB module was published in RFC 4836; for full legal notices see the RFC itself. Supplementary information may be available at: http://www.ietf.org/copyrights/ianamib.html |
RFC description
IANA standard MIB defining MAU (Medium Attachment Unit) types and textual conventions for IEEE 802.3 Ethernet physical layer devices (RFC 4836).
Start monitoring Vendor-neutral IANA/IETF standard (any Ethernet-capable network device) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.