| OID symbolic | OID numeric | Type | Access | Description |
| hwUserLogMIB | 1.3.6.1.4.1.2011.5.25.18 | | | The HUAWEI-USERLOG-MIB contains objects to
manage configuration and monitor running state
for userlog feature.
For users who access network through NAT and BAS
equipments, their IP addresses are generally
unfixed, and so it is hard to exactly locate which
host a certain access comes from and which user
initiates it. This decreases the network security.
User log is designed to solve the problem. User log
can record Network Address Translation (NAT) flow
information, and login/ logout information and flow
information of Broadband Access Server (BAS) user,
thus enabling the administrator know address
information before NAT, access record of BAS user, etc.
Then, network activities and operations can be queried
and tracked, and network availability and security are
improved accordingly. |
| hwUserlogObjects | 1.3.6.1.4.1.2011.5.25.18.1 | | | |
| hwUserlogNatObjects | 1.3.6.1.4.1.2011.5.25.18.1.1 | | | |
| I32 hwUserlogNatVersion | 1.3.6.1.4.1.2011.5.25.18.1.1.1 | Integer32 | read-only | NAT LOG version. Currently only version 1 is developed. |
| I32 hwUserlogNatSyslog | 1.3.6.1.4.1.2011.5.25.18.1.1.2 | Integer32 | read-write | NAT LOG format.
If 1, LOG format is sysLog.
If 0, LOG format is UDP packet.
UDP packet is the default format and is recommended.
Syslog can be used in the case that log amount is not too large. |
| IP hwUserlogNatSourceIP | 1.3.6.1.4.1.2011.5.25.18.1.1.3 | IpAddress | read-write | The Source IP address of NAT LOG UDP packet.
By default, the source IP address of the UDP packet
is the IP address of the interface through which the
router outputs the user log packet.
On the user log server side, the source of log
information can be located rapidly through identifying
the source IP address of the log. You are recommended
to configure a loopback address or router ID to function
as the source IP address of the UDP packet. |
| I32 hwUserlogNatFlowBegin | 1.3.6.1.4.1.2011.5.25.18.1.1.4 | Integer32 | read-write | Log the NAT flow when it is created.
If 1, this function is enabled.
If 0, this function is disabled.
This function will be used when real-time monitor is required.
The default value 0 means this function is disabled. |
| I32 hwUserlogNatActiveTime | 1.3.6.1.4.1.2011.5.25.18.1.1.5 | Integer32 | read-write | The active time for long-time existed NAT flow.
Unit: minute. Range: 10 minutes ~ 120 minutes.
When setting it, NAT flow can be logged after an interval of active time.
This function will be used when real-time monitor is required.
The default value 0 means real-time monitor function is disabled. |
| hwUserlogNatSlotCfgInfoTable | 1.3.6.1.4.1.2011.5.25.18.1.1.6 | | not-accessible | A table of NAT LOG configuration information for the specified slot.
By default, user log function is disabled on the interface board.
Only after user log function is enabled, the other configurations
related to user log take effect. |
| hwUserlogNatSlotCfgInfoEntry | 1.3.6.1.4.1.2011.5.25.18.1.1.6.1 | | not-accessible | NAT LOG configuration information entry for a slot. |
| I32 hwUserlogNatCfgSlotNumber | 1.3.6.1.4.1.2011.5.25.18.1.1.6.1.1 | Integer32 | read-only | Slot number.
The object specifies which slot is configured with NAT LOG.
For NAT LOG, it is the slot of the egress interface
configured with NAT. |
| I32 hwUserlogNatEnable | 1.3.6.1.4.1.2011.5.25.18.1.1.6.1.2 | Integer32 | read-write | The NAT LOG feature status.
If 1, NAT LOG is enabled.
If 0, NAT LOG is disabled.
The default value 0 means NAT LOG is disabled. |
| I32 hwUserlogNatAclNumber | 1.3.6.1.4.1.2011.5.25.18.1.1.6.1.3 | Integer32 | read-write | Access-list number. Its range is 2000 ~ 3999.
The value 0 means no ACL is specified.
Only when NAT LOG is enabled, and ACL is configured.
Only NAT flow which match the ACL will be logged. |
| IP hwUserlogNatHostAddress | 1.3.6.1.4.1.2011.5.25.18.1.1.6.1.4 | IpAddress | read-write | The IP address of NAT LOG server.
If user log is output in UDP packet mode, user log
server must be configured and user log server address
must be specified correctly. Otherwise, user log
function cannot work normally.
The address of the destination server must be a valid
unicast address rather than a loop address or multicast
address. In principle, it should be the address of the
user log server that can communicate normally. |
| I32 hwUserlogNatUdpPort | 1.3.6.1.4.1.2011.5.25.18.1.1.6.1.5 | Integer32 | read-write | The UDP Port Number of NAT LOG server. Its range is 1 ~ 65535.
In order to avoid confliction with general UDP port numbers,
you are recommended to use the UDP port number above 1024. |
| hwUserlogNatSlotRunInfoTable | 1.3.6.1.4.1.2011.5.25.18.1.1.7 | | not-accessible | A table of NAT LOG running information for the specified slot. |
| hwUserlogNatSlotRunInfoEntry | 1.3.6.1.4.1.2011.5.25.18.1.1.7.1 | | not-accessible | NAT LOG running information entry for a slot. |
| I32 hwUserlogNatRunSlotNumber | 1.3.6.1.4.1.2011.5.25.18.1.1.7.1.1 | Integer32 | read-only | Slot number.
The object specifies on which slot the NAT LOG statistics are calculated. |
| C32 hwUserlogNatTotalEntriesEx | 1.3.6.1.4.1.2011.5.25.18.1.1.7.1.2 | Counter32 | read-only | The total number of NAT flow entries which are logged. |
| C32 hwUserlogNatTotalPackets | 1.3.6.1.4.1.2011.5.25.18.1.1.7.1.3 | Counter32 | read-only | The total number of NAT LOG UDP packets generated by the device. |
| C32 hwUserlogNatFailedEntries | 1.3.6.1.4.1.2011.5.25.18.1.1.7.1.4 | Counter32 | read-only | The total number of NAT flow entries failed in outputting. |
| C32 hwUserlogNatFailedPackets | 1.3.6.1.4.1.2011.5.25.18.1.1.7.1.5 | Counter32 | read-only | The total number of NAT LOG UDP packets failed in outputting. |
| I32 hwUserlogNatClearRunStat | 1.3.6.1.4.1.2011.5.25.18.1.1.7.1.6 | Integer32 | read-write | Clears the running statistics for NAT LOG. Its access is write-only.
If 1, the running statistics for NAT LOG is resetted.
Other value is invalid. |
| hwUserlogFlowObjects | 1.3.6.1.4.1.2011.5.25.18.1.2 | | | |
| I32 hwUserlogFlowVersion | 1.3.6.1.4.1.2011.5.25.18.1.2.1 | Integer32 | read-only | BAS FLOW LOG version. Currently only version 1 is developed. |
| I32 hwUserlogFlowSyslog | 1.3.6.1.4.1.2011.5.25.18.1.2.2 | Integer32 | read-write | BAS FLOW LOG format.
If 1, LOG format is sysLog.
If 0, LOG format is UDP packet.
UDP packet is the default format, and is recommended.
Syslog can be used in the case that log amount is not
too large. |
| IP hwUserlogFlowSourceIP | 1.3.6.1.4.1.2011.5.25.18.1.2.3 | IpAddress | read-write | The Source IP address of BAS FLOW LOG UDP packet.
By default, the source IP address of the UDP packet
is the IP address of the interface through which the
router outputs the user log packet.
On the user log server side, the source of log
information can be located rapidly through identifying
the source IP address of the log. You are recommended
to configure a loopback address or router ID to function
as the source IP address of the UDP packet. |
| I32 hwUserlogFlowFlowBegin | 1.3.6.1.4.1.2011.5.25.18.1.2.4 | Integer32 | read-write | Log the BAS flow when it is created.
If 1, this function is enabled.
If 0, this function is disabled.
This function will be used when real-time monitor is required.
The default value 0 means this function is disabled. |
| I32 hwUserlogFlowActiveTime | 1.3.6.1.4.1.2011.5.25.18.1.2.5 | Integer32 | read-write | The active time for long-time existed BAS flow.
Its unit is minute. Its range is 10 minutes ~ 120 minutes.
When setting it, BAS flow can be logged after an internal of active time.
This function will be used when real-time monitor is required.
The default value 0 means real-time monitor function
is disabled. |
| hwUserlogFlowSlotCfgInfoTable | 1.3.6.1.4.1.2011.5.25.18.1.2.6 | | not-accessible | A table of BAS FLOW LOG configuration information for the specified slot.
By default, user log function is disabled on the interface board.
Only after user log function is enabled, the other configurations
related to user log take effect. |
| hwUserlogFlowSlotCfgInfoEntry | 1.3.6.1.4.1.2011.5.25.18.1.2.6.1 | | not-accessible | BAS FLOW LOG configuration information entry for a slot. |
| I32 hwUserlogFlowCfgSlotNumber | 1.3.6.1.4.1.2011.5.25.18.1.2.6.1.1 | Integer32 | read-only | Slot number.
The ojects specifies which slot is configured with BAS FLOW LOG. |
| I32 hwUserlogFlowEnable | 1.3.6.1.4.1.2011.5.25.18.1.2.6.1.2 | Integer32 | read-write | The BAS FLOW LOG feature status.
If 1, BAS FLOW LOG is enabled.
If 0, BAS FLOW LOG is disabled.
The default value 0 means BAS FLOW LOG is disabled. |
| I32 hwUserlogFlowAclNumber | 1.3.6.1.4.1.2011.5.25.18.1.2.6.1.3 | Integer32 | read-write | Access-list number. Its range is 2000 ~ 3999.
The value 0 means no ACL is specified.
Only when BAS FLOW LOG is enabled, the ACL be configured.
Only BAS flow which match the ACL will be logged. |
| IP hwUserlogFlowHostAddress | 1.3.6.1.4.1.2011.5.25.18.1.2.6.1.4 | IpAddress | read-write | The IP address of BAS FLOW LOG server.
If user log is output in UDP packet mode, user log
server must be configured and user log server address
must be specified correctly. Otherwise, user log
function cannot work normally.
The address of the destination server must be a valid
unicast address rather than a loop address or multicast
address. In principle, it should be the address of the
user log server that can communicate normally. |
| I32 hwUserlogFlowUdpPort | 1.3.6.1.4.1.2011.5.25.18.1.2.6.1.5 | Integer32 | read-write | The UDP Port Number of BAS FLOW LOG server. Its range is 1 ~ 65535.
In order to avoid confliction with general UDP port numbers,
you are recommended to use the UDP port number above 1024. |
| hwUserlogFlowSlotRunInfoTable | 1.3.6.1.4.1.2011.5.25.18.1.2.7 | | not-accessible | A table of BAS FLOW LOG running information for the specified slot. |
| hwUserlogFlowSlotRunInfoEntry | 1.3.6.1.4.1.2011.5.25.18.1.2.7.1 | | not-accessible | Running Information Entry for a slot. |
| I32 hwUserlogFlowRunSlotNumber | 1.3.6.1.4.1.2011.5.25.18.1.2.7.1.1 | Integer32 | read-only | Slot number.
The object specifies on which slot the BAS FLOW LOG statistics are calculated. |
| C32 hwUserlogFlowTotalEntries | 1.3.6.1.4.1.2011.5.25.18.1.2.7.1.2 | Counter32 | read-only | The total number of BAS FLOW Entries which are logged. |
| C32 hwUserlogFlowTotalPackets | 1.3.6.1.4.1.2011.5.25.18.1.2.7.1.3 | Counter32 | read-only | The total number of FLOW LOG UDP packet generated by the device. |
| C32 hwUserlogFlowFailedEntries | 1.3.6.1.4.1.2011.5.25.18.1.2.7.1.4 | Counter32 | read-only | The total number of BAS FLOW entries failed in outputting. |
| C32 hwUserlogFlowFailedPackets | 1.3.6.1.4.1.2011.5.25.18.1.2.7.1.5 | Counter32 | read-only | The total number of BAS FLOW LOG UDP packet failed in outputting. |
| I32 hwUserlogFlowClearRunStat | 1.3.6.1.4.1.2011.5.25.18.1.2.7.1.6 | Integer32 | read-write | Clears the running statistics for FLOW LOG. Its access is write-only.
If 1, the running statistics for FLOW LOG is resetted.
Other value is invalid. |
| hwUserlogAccessObjects | 1.3.6.1.4.1.2011.5.25.18.1.3 | | | |
| I32 hwUserlogAccessVersion | 1.3.6.1.4.1.2011.5.25.18.1.3.1 | Integer32 | read-only | BAS ACCESS LOG version. Currently only version 1 is developed. |
| I32 hwUserlogAccessSyslog | 1.3.6.1.4.1.2011.5.25.18.1.3.2 | Integer32 | read-write | BAS ACCESS LOG format.
If 1, LOG format is sysLog;
If 0, LOG format is UDP packet.
UDP packet is the default format, and is recommended.
Syslog can be used in the case that log amount is not too large. |
| IP hwUserlogAccessSourceIP | 1.3.6.1.4.1.2011.5.25.18.1.3.3 | IpAddress | read-write | The Source IP address of BAS ACCESS LOG UDP packet.
By default, the source IP address of the UDP packet
is the IP address of the interface through which the
router outputs the user log packet.
On the user log server side, the source of log
information can be located rapidly through identifying
the source IP address of the log. You are recommended
to configure a loopback address or router ID to function
as the source IP address of the UDP packet. |
| hwUserlogAccessSlotCfgInfoTable | 1.3.6.1.4.1.2011.5.25.18.1.3.4 | | not-accessible | A table of BAS ACCESS LOG configuration information for the specified slot. |
| hwUserlogAccessSlotCfgInfoEntry | 1.3.6.1.4.1.2011.5.25.18.1.3.4.1 | | not-accessible | BAS ACCESS LOG configuration information entry for a slot. |
| I32 hwUserlogAccessCfgSlotNumber | 1.3.6.1.4.1.2011.5.25.18.1.3.4.1.1 | Integer32 | read-only | Slot number.
The object specifies which slot is configured with BAS ACCESS LOG. |
| I32 hwUserlogAccessEnable | 1.3.6.1.4.1.2011.5.25.18.1.3.4.1.2 | Integer32 | read-write | The BAS ACCESS LOG feature status.
If 1, BAS ACCESS LOG is enabled.
If 0, BAS ACCESS LOG is disabled.
The default value 0 means BAS ACCESS LOG is disabled. |
| IP hwUserlogAccessHostAddress | 1.3.6.1.4.1.2011.5.25.18.1.3.4.1.3 | IpAddress | read-write | The IP address of BAS ACCESS LOG server.
If user log is output in UDP packet mode, user log
server must be configured and user log server address
must be specified correctly. Otherwise, user log
function cannot work normally.
The address of the destination server must be a valid
unicast address rather than a loop address or multicast
address. In principle, it should be the address of the
user log server that can communicate normally. |
| I32 hwUserlogAccessUdpPort | 1.3.6.1.4.1.2011.5.25.18.1.3.4.1.4 | Integer32 | read-write | The UDP Port Number of BAS ACCESS LOG server. Its range is 1 ~ 65535.
In order to avoid confliction with general UDP port numbers,
you are recommended to use the UDP port number above 1024. |
| hwUserlogAccessSlotRunInfoTable | 1.3.6.1.4.1.2011.5.25.18.1.3.5 | | not-accessible | A table of BAS ACCESS LOG running information
for the specified slot. |
| hwUserlogAccessSlotRunInfoEntry | 1.3.6.1.4.1.2011.5.25.18.1.3.5.1 | | not-accessible | Running Information Entry for a slot. |
| I32 hwUserlogAccessRunSlotNumber | 1.3.6.1.4.1.2011.5.25.18.1.3.5.1.1 | Integer32 | read-only | Slot number.
The object specifies on which slot the BAS ACCESS LOG statistics
are calculated. |
| C32 hwUserlogAccessTotalEntries | 1.3.6.1.4.1.2011.5.25.18.1.3.5.1.2 | Counter32 | read-only | The total number of BAS ACCESS records which are logged. |
| C32 hwUserlogAccessTotalPackets | 1.3.6.1.4.1.2011.5.25.18.1.3.5.1.3 | Counter32 | read-only | The total number of ACCESS LOG UDP packet generated by the router. |
| C32 hwUserlogAccessFailedEntries | 1.3.6.1.4.1.2011.5.25.18.1.3.5.1.4 | Counter32 | read-only | The total number of BAS ACCESS entries failed in outputting. |
| C32 hwUserlogAccessFailedPackets | 1.3.6.1.4.1.2011.5.25.18.1.3.5.1.5 | Counter32 | read-only | The total number of BAS ACCESS LOG UDP packet failed in outputting. |
| I32 hwUserlogAccessClearRunStat | 1.3.6.1.4.1.2011.5.25.18.1.3.5.1.6 | Integer32 | read-write | Clear the running statistics for ACCESS LOG. Its access is write-only.
If 1, the running statistics for ACCESS LOG is resetted,
the other value is invalid. |
| hwUserlogNotifications | 1.3.6.1.4.1.2011.5.25.18.2 | | | |
| hwUserlogConformance | 1.3.6.1.4.1.2011.5.25.18.3 | | | |
| hwUserlogCompliances | 1.3.6.1.4.1.2011.5.25.18.3.1 | | | |
| hwUserlogCompliance | 1.3.6.1.4.1.2011.5.25.18.3.1.1 | | | The compliance statement for entities which
implement the Huawei Userlog mib. |
| hwUserlogGroups | 1.3.6.1.4.1.2011.5.25.18.3.2 | | | |
| hwUserlogMandatoryGroup | 1.3.6.1.4.1.2011.5.25.18.3.2.1 | | | A collection of objects providing mandatory Userlog information. |
| hwUserlogConfigGroup | 1.3.6.1.4.1.2011.5.25.18.3.2.2 | | | All configurable parameters of Userlog feature. |
| hwUserlogInfoGroup | 1.3.6.1.4.1.2011.5.25.18.3.2.3 | | | All running information of Userlog feature. |