All MIBs › HUAWEI-ETHERNET-OPTICMODULE-MIB
Organization: Huawei Technologies Co.,Ltd.
Last Updated: 2011-07-05
Category: Technology: Optical Transport, Vendor: Huawei
Description: Huawei Ethernet optical module MIB providing digital diagnostic monitoring for SFP/QSFP transceiver modules including Tx/Rx power and temperature.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is HUAWEI-ETHERNET-OPTICMODULE-MIB?
HUAWEI-ETHERNET-OPTICMODULE-MIB is a Huawei MIB module providing Digital Diagnostic Monitoring (DDM) data for SFP, SFP+, and QSFP Ethernet optical transceiver modules installed in Huawei switches and routers. It exposes real-time optical transceiver metrics including transmit and receive optical power, module temperature, and related operating parameters, along with module identification/inventory information. This is a hardware health-monitoring MIB in the truest sense: degrading Tx/Rx power or rising module temperature are classic early-warning signs of a failing transceiver or a degraded fiber connection, well before the link actually drops. It builds on the SFF-8472 industry DDM standard for transceiver diagnostics, exposed here through a Huawei-private SNMP object tree rather than the IETF ENTITY-SENSOR-MIB. It is deployed in Huawei carrier and enterprise switches/routers wherever pluggable optics are used, particularly on core and uplink ports where optical link quality is critical. Engineers can download the HUAWEI-ETHERNET-OPTICMODULE-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in HUAWEI-ETHERNET-OPTICMODULE-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Huawei switches
- Huawei routers with pluggable optical transceivers
Monitoring Examples
An administrator would poll the optical module objects per interface to read current Tx power, Rx power, and module temperature, comparing them against vendor-specified thresholds. A steadily declining Rx power reading on a core uplink transceiver would predict an impending link failure, prompting proactive replacement before an outage occurs. An abnormally high module temperature reading could indicate a cooling problem in the chassis or a marginal optic nearing end-of-life.
What Can Be Monitored
- transmit optical power (Tx)
- receive optical power (Rx)
- optical module temperature
- transceiver module identification/inventory
This MIB depends on
Related MIBs
Imported Objects
From HUAWEI-DEVICE-MIB
| hwFrameIndex | OBJECT-TYPE |
| hwPortDesc | OBJECT-TYPE |
| hwPortIndex | OBJECT-TYPE |
| hwSlotIndex | OBJECT-TYPE |
From HUAWEI-MIB
| huaweiMgmt | OBJECT-IDENTITY |
From IF-MIB
| InterfaceIndex | |
| ifIndex | OBJECT-TYPE |
From SNMPv2-SMI
| Integer32 | |
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-TYPE | |
| TimeTicks | |
| Unsigned32 |
From SNMPv2-TC
| MacAddress | |
| RowStatus | |
| TEXTUAL-CONVENTION | |
| TruthValue |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| hwEthernet | 1.3.6.1.4.1.2011.5.14 | This mib is used for managing Ethernet optics module. | ||
| hwOpticsModuleInformation | 1.3.6.1.4.1.2011.5.14.6 | |||
| hwOpticsModuleInformationTable | 1.3.6.1.4.1.2011.5.14.6.1 | not-accessible | Indicates the optical module table of an Ethernet port. It is used for querying the information about the optical module of an Ethernet port. The index of this table is ifIndex. | |
| hwOpticsModuleInformationEntry | 1.3.6.1.4.1.2011.5.14.6.1.1 | not-accessible | Indicates the optical module table of an Ethernet port. It is used for querying the information about the optical module of an Ethernet port. The index of this entry is ifIndex. | |
| INT hwOpticsMDIdentifier | 1.3.6.1.4.1.2011.5.14.6.1.1.1 | INTEGER | read-only | Indicate the identifier of optical module. Options: 1. unknown(1) -unknown the identifier of optical module 2. gbic(2) -the identifier of optical module is gbic 3. solderedToMotherboard(3) -the identifier of optical module is solderedToMotherboard 4. sfp(4) -the identifier of optical module is sfp 5. pin300XBI(5) -the identifier of optical module is pin300XBI 6. xenpak(6) -the identifier of optical module is xenpak 7. xfp(7) -the identifier of optical module is xfp 8. xff(8) -the identifier of optical module is xff 9. xfpe(9) -the identifier of optical module is xfpe 10. xpak(10) -the identifier of optical module is xpak 11. x2(11) -the identifier of optical module is x2 |
| INT hwOpticsMDExtID | 1.3.6.1.4.1.2011.5.14.6.1.1.2 | INTEGER | read-only | Indicate the extended type of optical module. Options: 1. notSpecifiedOrNotCompliant(1) -the extended type of optical module is notSpecifiedOrNotCompliant 2. moddef1(2) -the extended type of optical module is moddef1 3. moddef2(3) -the extended type of optical module is moddef2 4. moddef3(4) -the extended type of optical module is moddef3 5. bySerialIDOnly(5) -the extended type of optical module is bySerialIDOnly 6. moddef5(6) -the extended type of optical module is moddef5 7. moddef6(7) -the extended type of optical module is moddef6 8. moddef7(8) -the extended type of optical module is moddef7 |
| INT hwOpticsMDConnector | 1.3.6.1.4.1.2011.5.14.6.1.1.3 | INTEGER | read-only | Indicate the type of optical module connector. Options: 1. unknown(1) -unknown the type of optical module connector 2. sc(2) -the type of optical module connector is sc 3. copperConnector1(3) -the type of optical module connector is copperConnector1 4. copperConnector2(4) -the type of optical module connector is copperConnector2 5. bnctnc(5) -the type of optical module connector is bnctnc 6. coaxialHeaders(6) -the type of optical module connector is coaxialHeaders 7. fiberJack(7) -the type of optical module connector is fiberJack 8. lc(8) -the type of optical module connector is lc 9. mtrj(9) -the type of optical module connector is mtrj 10. mu(10) -the type of optical module connector is mu 11. sg(11) -the type of optical module connector is sg 12. opticalPigtail(12) -the type of optical module connector is opticalPigtail 13. hssdcii(13) -the type of optical module connector is hssdcii 14. copperPigtail(14) -the type of optical module connector is copperPigtail 15. vendorSpecific(15) -the type of optical module connector is vendorSpecific |
| INT hwOpticsMDEncoding | 1.3.6.1.4.1.2011.5.14.6.1.1.4 | INTEGER | read-only | Indicate the encoding mechanism. Options: 1. unspecified(1) -the encoding mechanism is unspecified 2. encodingMethod8B10B(2) -the encoding mechanism is encodingMethod8B10B 3. encodingMethod4B5B(3) -the encoding mechanism is encodingMethod4B5B 4. nrz(4) -the encoding mechanism is nrz 5. manchester(5) -the encoding mechanism is manchester 6. sONETScrambled(6) -the encoding mechanism is sONETScrambled 7. encodingMethod64B66B(7) -the encoding mechanism is encodingMethod64B66B |
| I32 hwOpticsMDBrNominal | 1.3.6.1.4.1.2011.5.14.6.1.1.5 | Integer32 | read-only | Nominal bit rate. Unit: 100 MBits/sec |
| I32 hwOpticsMDLength9Micronkm | 1.3.6.1.4.1.2011.5.14.6.1.1.6 | Integer32 | read-only | Indicate the link length that is supported by the transceiver while operating in compliance with the applicable standards using 9 micron Single-mode Fiber. The maximum value is 255, which means that the transceiver supports a link length greater than 25.4 km. Unit: km |
| I32 hwOpticsMDLength9Micron | 1.3.6.1.4.1.2011.5.14.6.1.1.7 | Integer32 | read-only | Indicate the link length that is supported by the transceiver while operating in compliance with the applicable standards using 9 micron Single-mode Fiber. The maximum value is 255, which means that the transceiver supports a link length greater than 254 km. Unit: 100m |
| I32 hwOpticsMDLength50Micron | 1.3.6.1.4.1.2011.5.14.6.1.1.8 | Integer32 | read-only | Indicate link length that is supported by the transceiver while operating in compliance with applicable standards using 50 micron multi-mode OM2 [500MHz*km] fiber. The maximum value is 255, which means that the transceiver supports a link length greater than 2.54 km. Unit: 10m |
| I32 hwOpticsMDLength62Micron5 | 1.3.6.1.4.1.2011.5.14.6.1.1.9 | Integer32 | read-only | Indicate link length that is supported by the transceiver while operating in compliance with applicable standards using 62.5 micron multi-mode OM1 [200 MHz*km] fiber. The maximum value is 255, which means that the transceiver supports a link length greater than 2.54 km. Unit: 10m |
| I32 hwOpticsMDLengthCopper | 1.3.6.1.4.1.2011.5.14.6.1.1.10 | Integer32 | read-only | Indicate Link length supported for copper. Unit: 1m |
| OCT hwOpticsMDVendorName | 1.3.6.1.4.1.2011.5.14.6.1.1.11 | OCTET STRING | read-only | Indicate the vendor name of a optical module. |
| I32 hwOpticsMDVendorOUI | 1.3.6.1.4.1.2011.5.14.6.1.1.12 | Integer32 | read-only | Indicate the vendor IEEE company ID of a optical module. |
| OCT hwOpticsMDVendorPN | 1.3.6.1.4.1.2011.5.14.6.1.1.13 | OCTET STRING | read-only | Indicate the part number of a optical module provided by vendor. |
| OCT hwOpticsMDVendorRev | 1.3.6.1.4.1.2011.5.14.6.1.1.14 | OCTET STRING | read-only | Indicate the revision level for part number provided by vendor. |
| I32 hwOpticsMDWaveLength | 1.3.6.1.4.1.2011.5.14.6.1.1.15 | Integer32 | read-only | The laser wavelength. |
| I32 hwOpticsMDCcBase | 1.3.6.1.4.1.2011.5.14.6.1.1.16 | Integer32 | read-only | The check code for base ID fields(one byte). |
| INT hwOpticsMDOptions | 1.3.6.1.4.1.2011.5.14.6.1.1.17 | INTEGER | read-only | Options: 1. rateSelect(1) -RATE-SELECT is implemented 2. txDisableAndTheSerialOutputDisabled(2) -TX-DISABLE is implemented and disables the serial output. 3. txFault(3) -TX-FAULT signal implemented. 4. signalLossAndInvertedFromStandard(4) -Loss of Signal implemented, signal inverted from standard definition in SFP MSA. 5. signalLossAndAsDefined(5) -Loss of Signal implemented, signal as defined in SFP MSA |
| I32 hwOpticsMDBrMax | 1.3.6.1.4.1.2011.5.14.6.1.1.18 | Integer32 | read-only | The upper bit rate margin. |
| I32 hwOpticsMDBrMin | 1.3.6.1.4.1.2011.5.14.6.1.1.19 | Integer32 | read-only | The lower bit rate margin. |
| OCT hwOpticsMDVendorSN | 1.3.6.1.4.1.2011.5.14.6.1.1.20 | OCTET STRING | read-only | The serial number of a optical module provided by vendor. |
| OCT hwOpticsMDDateCode | 1.3.6.1.4.1.2011.5.14.6.1.1.21 | OCTET STRING | read-only | The date code of a optical module. |
| INT hwOpticsMDDiagnosticMonitoringType | 1.3.6.1.4.1.2011.5.14.6.1.1.22 | INTEGER | read-only | Indicate the diagnostic monitoring type. Options: 1. internallyCalibrated(1) -the diagnostic monitoring type is internallyCalibrated 2. externallyCalibrated(2) -the diagnostic monitoring type is externallyCalibrated 3. invalid(-1) -invalid value |
| INT hwOpticsMDEnhancedOptions | 1.3.6.1.4.1.2011.5.14.6.1.1.23 | INTEGER | read-only | Indicate enhanced Options. Options: 1. forAllMonitoredQuantities(1) -optional Alarm/warning flags implemented for all monitored quantities 2. txDisable(2) -optional Soft TX-DISABLE control and monitoring implemented 3. txFault(3) -optional Soft TX-FAULT monitoring implemented 4. rxLOS(4) -optional Soft RX-LOS monitoring implemented 5. rateSelect(5) -optional Soft RATE-SELECT control and monitoring implemented 6. invalid(-1) -invalid value |
| INT hwOpticsMDSFF8472Compliance | 1.3.6.1.4.1.2011.5.14.6.1.1.24 | INTEGER | read-only | Indicate the SFF-8472 standard. Options: 1. undefined(1) -not included or undefined. 2. includesSFF8472V93(2) -includes functionality described in Rev 9.3 SFF-8472. 3. includesSFF8472V95(3) -includes functionality described in Rev 9.5 SFF-8472. 4. includesSFF8472V102(4) -includes functionality described in Rev 10.2 SFF-8472. 5. tbd(5) -to be determined. |
| I32 hwOpticsMDCcExt | 1.3.6.1.4.1.2011.5.14.6.1.1.25 | Integer32 | read-only | Check code for the Extended ID Fields. |
| OCT hwOpticsMDVendorSpecific | 1.3.6.1.4.1.2011.5.14.6.1.1.26 | OCTET STRING | read-only | Vendor of Optical module specific information. |
| OCT hwOpticsMDCLEICode | 1.3.6.1.4.1.2011.5.14.6.1.1.27 | OCTET STRING | read-only | CLEI code supported by eSFP. Length is 10 bytes. |
| INT hwOpticsMDInfoRemote | 1.3.6.1.4.1.2011.5.14.6.1.1.28 | INTEGER | read-only | Indicates the operation is performed on a remote optical module. Options: 1. remote(1) -the operation is performed on a remote optical module 2. invalid(-1) -invalid value |
| hwOpticsModuleTransceiverTable | 1.3.6.1.4.1.2011.5.14.6.2 | not-accessible | This table used for querying the information about the optical transceiver of an Ethernet port. The index of this table is ifindex. | |
| hwOpticsModuleTransceiverEntry | 1.3.6.1.4.1.2011.5.14.6.2.1 | not-accessible | This table used for querying the information about the optical transceiver of an Ethernet port. The index of this entry is ifindex. | |
| INT hwOpticsMDInfinibandComplianceCodes | 1.3.6.1.4.1.2011.5.14.6.2.1.1 | INTEGER | read-only | Infiniband transceiver type. Options: 1. sx(1) -infiniband transceiver type is sx 2. lx(2) -infiniband transceiver type is lx 3. copperActive(3) -infiniband transceiver type is copperActive 4. copperPassive(4) -infiniband transceiver type is copperPassive 5. invalid(-1) -invalid value |
| INT hwOpticsMDSONETcomplianceCodes | 1.3.6.1.4.1.2011.5.14.6.2.1.2 | INTEGER | read-only | SONET transceiver type. Options: 1. oC48LongReach(1) -SONET transceiver type is oC48LongReach 2. oC48IntermediateReach(2) -SONET transceiver type is oC48IntermediateReach 3. oC48ShortReach(3) -SONET transceiver type is oC48ShortReach 4. oC12SingleModeLongReach(4) -SONET transceiver type is oC12SingleModeLongReach 5. oC12SingleModeIntermediateReach(5) -SONET transceiver type is oC12SingleModeIntermediateReach 6. oC12MultiModeShortReach(6) -SONET transceiver type is oC12MultiModeShortReach 7. oC3SingleModeLongReach(7) -SONET transceiver type is oC3SingleModeLongReach 8. oC3SingleModeIntermediateReach(8) -SONET transceiver type is oC3SingleModeIntermediateReach 9. oC3MultiModeShortReach(9) -SONET transceiver type is oC3MultiModeShortReach 10. invalid(-1) -invalid value |
| INT hwOpticsMDGEComplianceCodes | 1.3.6.1.4.1.2011.5.14.6.2.1.3 | INTEGER | read-only | Ethernet transceiver type. Options: 1. en1000BASET(1) -Ethernet transceiver type is 1000BASE-T 2. en1000BASECX(2) -Ethernet transceiver type is 1000BASE-CX 3. en1000BASELX(3) -Ethernet transceiver type is 1000BASE-LX 4. en1000BASESX(4) -Ethernet transceiver type is 1000BASE-SX 5. enMULTILX(5) -Ethernet transceiver type is 100BASE-LX&1000BASE-LX 6. en100BASELX(6) -Ethernet transceiver type is 100BASE-LX 7. en100BASEFX(7) -Ethernet transceiver type is 100BASE-FX 8. en1000BASEBX(8) -Ethernet transceiver type is 1000BASE-BX 9. en1000BASEPX(9) -Ethernet transceiver type is 1000BASE-PX 10. en10GBASELRM(10) -Ethernet transceiver type is 10GBASE-LRM 11. en10GBASELR(11) -Ethernet transceiver type is 10GBASE-LR 12. en10GBASESR(12) -Ethernet transceiver type is 10GBASE-SR 13. en100BASEBX(13) -Ethernet transceiver type is 100BASE-BX |
| INT hwOpticsMDLinkLength | 1.3.6.1.4.1.2011.5.14.6.2.1.4 | INTEGER | read-only | Fibre Channel link length. Options: 1. veryLongDistance(1) -fibre channel link length is veryLongDistance 2. shortDistance(2) -fibre channel link length is shortDistance 3. intermediateDistance(3) -fibre channel link length is intermediateDistance 4. longDistance(4) -fibre channel link length is longDistance 5. invalid(-1) -invalid value |
| INT hwOpticsMDTransmitterTechnology | 1.3.6.1.4.1.2011.5.14.6.2.1.5 | INTEGER | read-only | Fibre Channel transmitter technology. Options: 1. longwaveLaser(1) -fibre channel transmitter technology is longwaveLaser 2. electricalInterenclosure(2) -fibre channel transmitter technology is electricalInterenclosure 3. shortwaveLaser(3) -fibre channel transmitter technology is shortwaveLaser 4. invalid(-1) -invalid value |
| INT hwOpticsMDTransmissionMedia | 1.3.6.1.4.1.2011.5.14.6.2.1.6 | INTEGER | read-only | Fibre Channel transmission media. Options: 1. twinAxialPair(1) -fibre channel transmission media is twinAxialPair 2. shieldedTwistedPair(2) -fibre channel transmission media is shieldedTwistedPair 3. miniatureCoax(3) -fibre channel transmission media is miniatureCoax 4. videoCoax(4) -fibre channel transmission media is videoCoax 5. multiMode62m5(5) -fibre channel transmission media is multiMode62m5 6. multiMode50m(6) -fibre channel transmission media is multiMode50m 7. singleMode(7) -fibre channel transmission media is singleMode 8. invalid(-1) -invalid value |
| INT hwOpticsMDSpeed | 1.3.6.1.4.1.2011.5.14.6.2.1.7 | INTEGER | read-only | Fibre Channel speed. Options: 1. speed400MBytesPerSec(1) -fibre channel speed is 400 MBits/s 2. speed200MBytesPerSec(2) -fibre channel speed is 200 MBits/s 3. speed100MBytesPerSec(3) -fibre channel speed is 100 MBits/s 4. invalid(-1) -invalid value |
| INT hwOpticsMDTransceiverRemote | 1.3.6.1.4.1.2011.5.14.6.2.1.8 | INTEGER | read-only | Indicates the operation is performed on a remote optical module. Options: 1. remote(1) -the operation is performed on a remote optical module 2. invalid(-1) -invalid value |
| hw10GEOpticsModuleInformationTable | 1.3.6.1.4.1.2011.5.14.6.3 | not-accessible | Indicates the 10GE optical module information table of an Ethernet port. It is used for querying the information about the 10GE optical module of an Ethernet port. The index of this table is ifindex. | |
| hw10GEOpticsModuleInformationEntry | 1.3.6.1.4.1.2011.5.14.6.3.1 | not-accessible | Indicates the 10GE optical module information table of an Ethernet port. It is used for querying the information about the 10GE optical module of an Ethernet port. The index of this entry is ifindex. | |
| INT hw10GEOpticsMDIdentifier | 1.3.6.1.4.1.2011.5.14.6.3.1.1 | INTEGER | read-only | Indicate the identifier of 10GE optical module. Options: 1. unknown(0) -unknown identifier of 10GE optical module 2. gbic(1) -the identifier of 10GE optical module is gbic 3. solderedToMotherBoard(2) -the identifier of 10GE optical module is solderedToMotherBoard 4. sfp(3) -the identifier of 10GE optical module is sfp 5. pin300XBI(4) -the identifier of 10GE optical module is pin300XBI 6. xenpak(5) -the identifier of 10GE optical module is xenpak 7. xfp(6) -the identifier of 10GE optical module is xfp 8. xff(7) -the identifier of 10GE optical module is xff 9. xfep(8) -the identifier of 10GE optical module is xfep 10. xpak(9) -the identifier of 10GE optical module is xpak 11. x2(10) -the identifier of 10GE optical module is x2 |
| INT hw10GEOpticsMDExtCLEICode | 1.3.6.1.4.1.2011.5.14.6.3.1.2 | INTEGER | read-only | Extended identifier: CLEI Options: 1. nonExtCLEICode(0) -no CLEI code present in Table 02h 2. extCLEICode(1) -CLEI code present in Table 02h |
| INT hw10GEOpticsMDExtTXRefClock | 1.3.6.1.4.1.2011.5.14.6.3.1.3 | INTEGER | read-only | Extended identifier: TX Ref Clock Options: 1. nonExtTXRefClock(0) -tx Ref Clock Input Not Required 2. extTXRefClock(1) -tx Ref Clock Input Required |
| INT hw10GEOpticsMDExtCDRFunc | 1.3.6.1.4.1.2011.5.14.6.3.1.4 | INTEGER | read-only | Extended identifier: CDR function Options: 1. nonExtCDRFunc(0) -no CDR version of XFP 2. extCDRFunc(1) -module with CDR function |
| INT hw10GEOpticsMDExtPowerLevel | 1.3.6.1.4.1.2011.5.14.6.3.1.5 | INTEGER | read-only | Extended identifier: Power Level Options: 1. extPowerLevel1(0) -power Level 1 Module (1.5 W max. power dissipation.) 2. extPowerLevel2(1) -power Level 2 Module (2.5W Max) 3. extPowerLevel3(2) -power Level 3 Module (3.5W max. power dissipation.) 4. extPowerLevel4(3) -power Level 4 Module (>3.5W max. power dissipation.) |
| INT hw10GEOpticsMDConnector | 1.3.6.1.4.1.2011.5.14.6.3.1.6 | INTEGER | read-only | Indicate the type of 10GE optical module connector. Options: 1. unknown(0) -unknown the type of 10GE optical module connector 2. sc(1) -the type of 10GE optical module connector is sc 3. style1Connector(2) -the type of 10GE optical module connector is style1Connector 4. style2Connector(3) -the type of 10GE optical module connector is style2Connector 5. bnctnc(4) -the type of 10GE optical module connector is bnctnc 6. channelCoaxial(5) -the type of 10GE optical module connector is channelCoaxial 7. fiberJack(6) -the type of 10GE optical module connector is fiberJack 8. lc(7) -the type of 10GE optical module connector is lc 9. mtrj(8) -the type of 10GE optical module connector is mtrj 10. mu(9) -the type of 10GE optical module connector is mu 11. sg(10) -the type of 10GE optical module connector is sg 12. opticalPigtail(11) -the type of 10GE optical module connector is opticalPigtail 13. hssdc(20) -the type of 10GE optical module connector is hssdc 14. copperPigtail(21) -the type of 10GE optical module connector is copperPigtail |
| INT hw10GEOpticsMDEthComplianceBaseEW | 1.3.6.1.4.1.2011.5.14.6.3.1.7 | INTEGER | read-only | Indicate 10GBASE-EW support or not. Options: 1. nonEthComplianceBaseEW(0) -not support 10GBASE-EW 2. ethComplianceBaseEW(1) -support 10GBASE-EW |
| INT hw10GEOpticsMDEthComplianceBaseLW | 1.3.6.1.4.1.2011.5.14.6.3.1.8 | INTEGER | read-only | Indicate 10GBASE-LW support or not. Options: 1. nonEthComplianceBaseLW(0) -not support 10GBASE-LW 2. ethComplianceBaseLW(1) -support 10GBASE-LW |
| INT hw10GEOpticsMDEthComplianceBaseSW | 1.3.6.1.4.1.2011.5.14.6.3.1.9 | INTEGER | read-only | Indicate 10GBASE-SW support or not. Options: 1. nonEthComplianceBaseSW(0) -not support 10GBASE-SW 2. ethComplianceBaseSW(1) -support 10GBASE-SW |
| INT hw10GEOpticsMDEthComplianceBaseLRM | 1.3.6.1.4.1.2011.5.14.6.3.1.10 | INTEGER | read-only | Indicate 10GBASE-LRM support or not. Options: 1. nonEthComplianceBaseLRM(0) -not support 10GBASE-LRM 2. ethComplianceBaseLRM(1) -support 10GBASE-LRM |
| INT hw10GEOpticsMDEthComplianceBaseER | 1.3.6.1.4.1.2011.5.14.6.3.1.11 | INTEGER | read-only | Indicate 10GBASE-ER support or not. Options: 1. nonEthComplianceBaseER(0) -not support 10GBASE-ER 2. ethComplianceBaseER(1) -support 10GBASE-ER |
| INT hw10GEOpticsMDEthComplianceBaseLR | 1.3.6.1.4.1.2011.5.14.6.3.1.12 | INTEGER | read-only | Indicate 10GBASE-LR support or not. Options: 1. nonEthComplianceBaseLR(0) -not support 10GBASE-LR 2. ethComplianceBaseLR(1) -support 10GBASE-LR |
| INT hw10GEOpticsMDEthComplianceBaseSR | 1.3.6.1.4.1.2011.5.14.6.3.1.13 | INTEGER | read-only | Indicate 10GBASE-SR support or not. Options: 1. nonEthComplianceBaseSR(0) -not support 10GBASE-SR 2. ethComplianceBaseSR(1) -support 10GBASE-SR |
| INT hw10GEOpticsMDFibreCompliance | 1.3.6.1.4.1.2011.5.14.6.3.1.14 | INTEGER | read-only | Indicate 10 Gigabit Fibre Channel Compliance type. Options: 1. fibreComplianceInter1300FP(16) -intermediate Reach 1300 nm FP 2. fibreComplianceExtended1550(32) -extended reach 1550 nm 3. fibreComplianceSM1200(64) -1200-SM-LL-L 4. fibreComplianceMX1200(128) -1200-MX-SN-I 5. invalid(-1) -invalid value |
| INT hw10GEOpticsMDLowerSpeedLink | 1.3.6.1.4.1.2011.5.14.6.3.1.15 | INTEGER | read-only | Indicate Lower Speed Links type. Options: 1. lowerSpeedLinkOC48LR(2) -lower speed links type is OC48LR 2. lowerSpeedLinkOC48IR(4) -lower speed links type is OC48IR 3. lowerSpeedLinkOC48SR(8) -lower speed links type is OC48SR 4. lowerSpeedLinkFCSMF(16) -lower speed links type is FCSMF 5. lowerSpeedLinkFCMMF(32) -lower speed links type is FCMMF 6. lowerSpeedLinkLXSMF(64) -lower speed links type is LXSMF 7. lowerSpeedLinkSXMMF(128) -lower speed links type is SXMMF 8. invalid(-1) -invalid value |
| INT hw10GEOpticsMDSONETSDHCodesI64point5 | 1.3.6.1.4.1.2011.5.14.6.3.1.16 | INTEGER | read-only | Indicate SONET/SDH Codes I-64.5 support or not. Options: 1. notSupport(0) -not Support I-64.5 2. support(1) -support I-64.5 |
| INT hw10GEOpticsMDSONETSDHCodesI64point3 | 1.3.6.1.4.1.2011.5.14.6.3.1.17 | INTEGER | read-only | Indicate SONET/SDH Codes I-64.3 support or not. Options: 1. notSupport(0) -not Support I-64.3 2. support(1) -support I-64.3 |
| INT hw10GEOpticsMDSONETSDHCodesI64point2 | 1.3.6.1.4.1.2011.5.14.6.3.1.18 | INTEGER | read-only | Indicate SONET/SDH Codes I-64.2 support or not. Options: 1. notSupport(0) -not Support I-64.2 2. support(1) -support I-64.2 |
| INT hw10GEOpticsMDSONETSDHCodesI64point2r | 1.3.6.1.4.1.2011.5.14.6.3.1.19 | INTEGER | read-only | Indicate SONET/SDH Codes I-64.2r support or not. Options: 1. notSupport(0) -not support I-64.2r 2. support(1) -support I-64.2r |
| INT hw10GEOpticsMDSONETSDHCodesI64point1 | 1.3.6.1.4.1.2011.5.14.6.3.1.20 | INTEGER | read-only | Indicate SONET/SDH Codes I-64.1 support or not. Options: 1. notSupport(0) -not support I-64.1 2. support(1) -support I-64.1 |
| INT hw10GEOpticsMDSONETSDHCodesI64point1r | 1.3.6.1.4.1.2011.5.14.6.3.1.21 | INTEGER | read-only | Indicate SONET/SDH Codes I-64.1r support or not. Options: 1. notSupport(0) -not support I-64.1r 2. support(1) -support I-64.1r |
| INT hw10GEOpticsMDSONETSDHCodesS64point5b | 1.3.6.1.4.1.2011.5.14.6.3.1.22 | INTEGER | read-only | Indicate SONET/SDH Codes S-64.5b support or not. Options: 1. notSupport(0) -not support S-64.5b 2. support(1) -support S-64.5b |
| INT hw10GEOpticsMDSONETSDHCodesS64point5a | 1.3.6.1.4.1.2011.5.14.6.3.1.23 | INTEGER | read-only | Indicate SONET/SDH Codes S-64.5a support or not. Options: 1. notSupport(0) -not support S-64.5a 2. support(1) -support S-64.5a |
| INT hw10GEOpticsMDSONETSDHCodesS64point3b | 1.3.6.1.4.1.2011.5.14.6.3.1.24 | INTEGER | read-only | Indicate SONET/SDH Codes S-64.3b support or not. Options: 1. notSupport(0) -not support S-64.3b 2. support(1) -support S-64.3b |
| INT hw10GEOpticsMDSONETSDHCodesS64point3a | 1.3.6.1.4.1.2011.5.14.6.3.1.25 | INTEGER | read-only | Indicate SONET/SDH Codes S-64.3a support or not. Options: 1. notSupport(0) -not support S-64.3a 2. support(1) -support S-64.3a |
| INT hw10GEOpticsMDSONETSDHCodesS64point2b | 1.3.6.1.4.1.2011.5.14.6.3.1.26 | INTEGER | read-only | Indicate SONET/SDH Codes S-64.2b support or not. Options: 1. notSupport(0) -not support S-64.2b 2. support(1) -support S-64.2b |
| INT hw10GEOpticsMDSONETSDHCodesS64point2a | 1.3.6.1.4.1.2011.5.14.6.3.1.27 | INTEGER | read-only | Indicate SONET/SDH Codes S-64.2a support or not. Options: 1. notSupport(0) -not support S-64.2a 2. support(1) -support S-64.2a |
| INT hw10GEOpticsMDSONETSDHCodesS64point1 | 1.3.6.1.4.1.2011.5.14.6.3.1.28 | INTEGER | read-only | Indicate SONET/SDH Codes S-64.1 support or not. Options: 1. notSupport(0) -not support S-64.1 2. support(1) -support S-64.1 |
| INT hw10GEOpticsMDSONETSDHCodesG959P1L1 | 1.3.6.1.4.1.2011.5.14.6.3.1.29 | INTEGER | read-only | Indicate SONET/SDH Codes G.959.1 P1L1-2D2 support or not. Options: 1. notSupport(0) -not support G.959.1 P1L1-2D2 2. support(1) -support G.959.1 P1L1-2D2 |
| INT hw10GEOpticsMDSONETSDHCodesL64point3 | 1.3.6.1.4.1.2011.5.14.6.3.1.30 | INTEGER | read-only | Indicate SONET/SDH Codes L-64.3 support or not. Options: 1. notSupport(0) -not support L-64.3 2. support(1) -support L-64.3 |
| INT hw10GEOpticsMDSONETSDHCodesL64point2c | 1.3.6.1.4.1.2011.5.14.6.3.1.31 | INTEGER | read-only | Indicate SONET/SDH Codes L-64.2c support or not. Options: 1. notSupport(0) -not support L-64.2c 2. support(1) -support L-64.2c |
| INT hw10GEOpticsMDSONETSDHCodesL64point2b | 1.3.6.1.4.1.2011.5.14.6.3.1.32 | INTEGER | read-only | Indicate SONET/SDH Codes L-64.2b support or not. Options: 1. notSupport(0) -not support L-64.2b 2. support(1) -support L-64.2b |
| INT hw10GEOpticsMDSONETSDHCodesL64point2a | 1.3.6.1.4.1.2011.5.14.6.3.1.33 | INTEGER | read-only | Indicate SONET/SDH Codes L-64.2a support or not. Options: 1. notSupport(0) -not support L-64.2a 2. support(1) -support L-64.2a |
| INT hw10GEOpticsMDSONETSDHCodesL64point1 | 1.3.6.1.4.1.2011.5.14.6.3.1.34 | INTEGER | read-only | Indicate SONET/SDH Codes L-64.1 support or not. Options: 1. notSupport(0) -not support L-64.1 2. support(1) -support L-64.1 |
| INT hw10GEOpticsMDSONETSDHCodesV64point3 | 1.3.6.1.4.1.2011.5.14.6.3.1.35 | INTEGER | read-only | Indicate SONET/SDH Codes V-64.3 support or not. Options: 1. notSupport(0) -not support V-64.3 2. support(1) -support V-64.3 |
| INT hw10GEOpticsMDSONETSDHCodesV64point2b | 1.3.6.1.4.1.2011.5.14.6.3.1.36 | INTEGER | read-only | Indicate SONET/SDH Codes V-64.2b support or not. Options: 1. notSupport(0) -not support V-64.2b 2. support(1) -support V-64.2b |
| INT hw10GEOpticsMDSONETSDHCodesV64point2a | 1.3.6.1.4.1.2011.5.14.6.3.1.37 | INTEGER | read-only | Indicate SONET/SDH Codes V-64.2a support or not. Options: 1. notSupport(0) -not support V-64.2a 2. support(1) -support V-64.2a |
| INT hw10GEOpticsMDEncodingRZ | 1.3.6.1.4.1.2011.5.14.6.3.1.38 | INTEGER | read-only | Indicate encoding mechanism RZ support or not. Options: 1. nonEncodingRZ(0) -not support RZ 2. encodingRZ(1) -support RZ |
| INT hw10GEOpticsMDEncodingNRZ | 1.3.6.1.4.1.2011.5.14.6.3.1.39 | INTEGER | read-only | Indicate encoding mechanism NRZ support or not. Options: 1. nonEncodingNRZ(0) -not support NRZ 2. encodingNRZ(1) -support NRZ |
| INT hw10GEOpticsMDEncodingSONET | 1.3.6.1.4.1.2011.5.14.6.3.1.40 | INTEGER | read-only | Indicate encoding mechanism SONET support or not. Options: 1. nonEncodingSONET(0) -not support SONET 2. encodingSONET(1) -support SONET |
| INT hw10GEOpticsMDEncoding8B10B | 1.3.6.1.4.1.2011.5.14.6.3.1.41 | INTEGER | read-only | Indicate encoding mechanism 8B10B support or not. Options: 1. nonEncoding8B10B(0) -not support 8B10B 2. encoding8B10B(1) -support 8B10B |
| INT hw10GEOpticsMDEncoding64B | 1.3.6.1.4.1.2011.5.14.6.3.1.42 | INTEGER | read-only | Indicate encoding mechanism 64B/66B support or not. Options: 1. nonEncoding64B(0) -not support 64B/66B 2. encoding64B(1) -support 64B/66B |
| I32 hw10GEOpticsMDBrMin | 1.3.6.1.4.1.2011.5.14.6.3.1.43 | Integer32 | read-only | Minimum bit rate. Unit: 100 MBits/s |
| I32 hw10GEOpticsMDBrMax | 1.3.6.1.4.1.2011.5.14.6.3.1.44 | Integer32 | read-only | Maximum bit rate. Unit: 100 MBits/s |
| I32 hw10GEOpticsMDSupportLenSMF | 1.3.6.1.4.1.2011.5.14.6.3.1.45 | Integer32 | read-only | Indicate the link length that is supported by the transceiver with the applicable standards using Single-mode Fiber. |
| I32 hw10GEOpticsMDSupportLenE50um | 1.3.6.1.4.1.2011.5.14.6.3.1.46 | Integer32 | read-only | Indicate the link length that is supported by the transceiver with the applicable standards using 2000MHz*km (850nm) extended bandwidth 50 micron core multimode fiber. Unit: 2m |
| I32 hw10GEOpticsMDSupportLen50um | 1.3.6.1.4.1.2011.5.14.6.3.1.47 | Integer32 | read-only | This value specifies the link length that is supported by the transceiver with the applicable standards using 500MHz*km (850 and 1310nm) 50 micron core multimode fiber. Unit: 1m |
| I32 hw10GEOpticsMDSupportLen62p5um | 1.3.6.1.4.1.2011.5.14.6.3.1.48 | Integer32 | read-only | This value specifies the link length that is supported by the transceiver with the applicable standards using 200MHz*km (850 nm)/500 MHz*km (1310 nm) 62.5 micron core multimode fiber. Unit: 1m |
| I32 hw10GEOpticsMDSupportLenCopper | 1.3.6.1.4.1.2011.5.14.6.3.1.49 | Integer32 | read-only | Indicate the minimum link length that is supported by the transceiver with copper cable. Unit: 1m |
| INT hw10GEOpticsMDTransmitterSupport | 1.3.6.1.4.1.2011.5.14.6.3.1.50 | INTEGER | read-only | Indicate the transmitter support tunable or not. Options: 1. nonTunable(0) -transmitter not support tunable 2. tunable(1) -transmitter support tunable |
| INT hw10GEOpticsMDDetector | 1.3.6.1.4.1.2011.5.14.6.3.1.51 | INTEGER | read-only | Indicate the Detector is enable or not. Options: 1. nonDetector(0) -detector is disable 2. detector(1) -detector is enable |
| INT hw10GEOpticsMDCooledTransmitterDevice | 1.3.6.1.4.1.2011.5.14.6.3.1.52 | INTEGER | read-only | Indicate the Cooled transmitter is enable or not. Options: 1. nonSupport(0) -cooled transmitter is disable 2. support(1) -cooled transmitter is enable |
| INT hw10GEOpticsMDWavelengthControl | 1.3.6.1.4.1.2011.5.14.6.3.1.53 | INTEGER | read-only | Indicate the wavelength control support or not. Options: 1. nonSupport(0) -wavelength control not support 2. support(1) -wavelength control support |
| INT hw10GEOpticsMDTransmitterTechnologySupport | 1.3.6.1.4.1.2011.5.14.6.3.1.54 | INTEGER | read-only | Indicate the transmitter technology type. Options: 1. vCSEL850(0) -the transmitter technology type is vCSEL850 2. vCSEL1310(1) -the transmitter technology type is vCSEL1310 3. vCSEL1550(2) -the transmitter technology type is vCSEL1550 4. fP1310(3) -the transmitter technology type is fP1310 5. dFB1310(4) -the transmitter technology type is dFB1310 6. dFB1550(5) -the transmitter technology type is dFB1550 7. eML1310(6) -the transmitter technology type is eML1310 8. eML1550(7) -the transmitter technology type is eML1550 9. cOPPER(8) -the transmitter technology type is cOPPER |
| OCT hw10GEOpticsMDVendorName | 1.3.6.1.4.1.2011.5.14.6.3.1.55 | OCTET STRING | read-only | Indicate the vendor name of a 10GE optical module. |
| INT hw10GEOpticsMDSupportXFIMode | 1.3.6.1.4.1.2011.5.14.6.3.1.56 | INTEGER | read-only | Indicate the XFI loopback mode support or not. Options: 1. nonSupportXFIMode(0) -the XFI loopback mode not support 2. supportXFIMode(1) -the XFI loopback mode support |
| INT hw10GEOpticsMDSupportLinesideMode | 1.3.6.1.4.1.2011.5.14.6.3.1.57 | INTEGER | read-only | Indicate the Lineside loopback mode support or not. Options: 1. nonSupportLinesideMode(0) -lineside loopback mode not support 2. supportLinesideMode(1) -lineside loopback mode support |
| INT hw10GEOpticsMDMaxBitRateSupportedByCDR | 1.3.6.1.4.1.2011.5.14.6.3.1.58 | INTEGER | read-only | Indicate which rate is supported by the CDR. Options: 1. maxBitRateSupportedByCDR11p1(1) -CDR support for 11.1 Gb/s 2. maxBitRateSupportedByCDR10p7(3) -CDR support for 10.7 Gb/s 3. maxBitRateSupportedByCDR10p5(7) -CDR support for 10.5 Gb/s 4. maxBitRateSupportedByCDR10p3(15) -CDR support for 10.3 Gb/s 5. maxBitRateSupportedByCDR9p95(31) -CDR support for 9.95 Gb/s 6. invalid(-1) -invalid value |
| I32 hw10GEOpticsMDVendorOUI | 1.3.6.1.4.1.2011.5.14.6.3.1.59 | Integer32 | read-only | Indicate the vendor IEEE company ID of a 10GE optical module. |
| OCT hw10GEOpticsMDVendorPN | 1.3.6.1.4.1.2011.5.14.6.3.1.60 | OCTET STRING | read-only | Indicate the part number of a 10GE optical module provided by vendor. |
| OCT hw10GEOpticsMDVendorRev | 1.3.6.1.4.1.2011.5.14.6.3.1.61 | OCTET STRING | read-only | Indicate the revision level for part number provided by vendor. |
| I32 hw10GEOpticsMDWavelength | 1.3.6.1.4.1.2011.5.14.6.3.1.62 | Integer32 | read-only | The laser wavelength. |
| I32 hw10GEOpticsMDWaveTolerance | 1.3.6.1.4.1.2011.5.14.6.3.1.63 | Integer32 | read-only | The guaranteed +/- range of transmitter output wavelength under all normal operating conditions. |
| I32 hw10GEOpticsMDMaxCaseTemperature | 1.3.6.1.4.1.2011.5.14.6.3.1.64 | Integer32 | read-only | Maximum Case Temperature in Degrees C. |
| I32 hw10GEOpticsMDCcbase | 1.3.6.1.4.1.2011.5.14.6.3.1.65 | Integer32 | read-only | Cc-base. |
| I32 hw10GEOpticsMDMaxDissipation | 1.3.6.1.4.1.2011.5.14.6.3.1.66 | Integer32 | read-only | Maximum Power Dissipation. Max power is 8 bit value * 20 mW. |
| I32 hw10GEOpticsMDMaxDissipationPowerDownMode | 1.3.6.1.4.1.2011.5.14.6.3.1.67 | Integer32 | read-only | Maximum Total Power Dissipation in Power Down Mode. Max Power is 8 bit value * 10 mW. |
| I32 hw10GEOpticsMDMaximum5P0VSupply | 1.3.6.1.4.1.2011.5.14.6.3.1.68 | Integer32 | read-only | Maximum current required by +5V Supply. |
| I32 hw10GEOpticsMDMaximum3P3VSupply | 1.3.6.1.4.1.2011.5.14.6.3.1.69 | Integer32 | read-only | Maximum current required by +3.3V Supply. |
| I32 hw10GEOpticsMDMaximum1P8VSupply | 1.3.6.1.4.1.2011.5.14.6.3.1.70 | Integer32 | read-only | Maximum current required by +1.8V Supply. |
| I32 hw10GEOpticsMDMaximum5P2VSupply | 1.3.6.1.4.1.2011.5.14.6.3.1.71 | Integer32 | read-only | Maximum current required by -5.2V Supply. |
| OCT hw10GEOpticsMDVendorSN | 1.3.6.1.4.1.2011.5.14.6.3.1.72 | OCTET STRING | read-only | The serial number of a 10GE optical module provided by vendor. |
| OCT hw10GEOpticsMDDateCode | 1.3.6.1.4.1.2011.5.14.6.3.1.73 | OCTET STRING | read-only | The date code of a 10GE optical module. |
| INT hw10GEOpticsMDDiagnoMonitorPowerMeasure | 1.3.6.1.4.1.2011.5.14.6.3.1.74 | INTEGER | read-only | Received power measurement type. Options: 1. supportOMA(0) -OMA 2. supportAveragePower(1) -AveragePower |
| INT hw10GEOpticsMDDiagnoMonitorTypeFECBER | 1.3.6.1.4.1.2011.5.14.6.3.1.75 | INTEGER | read-only | Module Respond to FEC BER. Options: 1. nonSupportBER(0) -no BER Support 2. supportBER(1) -BER Support |
| INT hw10GEOpticsMDEnhancedOptions | 1.3.6.1.4.1.2011.5.14.6.3.1.76 | INTEGER | read-only | Indicate enhanced Options. Options: 1. cmu(0) -enhanced options is cmu 2. rateSelect(2) -enhanced options is rateSelect 3. fec(4) -enhanced options is fec 4. vpsby(8) -enhanced options is vpsby 5. rxLOS(16) -enhanced options is rxLOS 6. txFault(32) -enhanced options is txFault 7. txDisable(64) -enhanced options is txDisable 8. alarmFLGIM(128) -enhanced options is alarmFLGIM |
| INT hw10GEOpticsMDAuxInputOne | 1.3.6.1.4.1.2011.5.14.6.3.1.77 | INTEGER | read-only | Indicate which quantity is monitored by each auxiliary A/D channel one. Options: 1. auxInputType1(0) -Auxiliary monitoring not implemented 2. auxInputType2(1) -APD Bias Voltage 3. auxInputType4(3) -TEC Current (mA) 4. auxInputType5(4) -Laser Temperature 5. auxInputType6(5) -Laser Wavelength 6. auxInputType7(6) -+5V Supply Voltage 7. auxInputType8(7) -+3.3V Supply Voltage 8. auxInputType9(8) -+1.8V Supply Voltage 9. auxInputType10(9) --5.2V Supply Voltage 10. auxInputType11(10) -+5V Supply Current 11. auxInputType14(13) -+3.3V Supply Current 12. auxInputType15(14) -+1.8V Supply Current 13. auxInputType16(15) --5.2V Supply Current |
| INT hw10GEOpticsMDAuxInputTwo | 1.3.6.1.4.1.2011.5.14.6.3.1.78 | INTEGER | read-only | Indicate which quantity is monitored by each auxiliary A/D channel two. Options: 1. auxInputType1(0) -Auxiliary monitoring not implemented 2. auxInputType2(1) -APD Bias Voltage 3. auxInputType4(3) -TEC Current (mA) 4. auxInputType5(4) -Laser Temperature 5. auxInputType6(5) -Laser Wavelength 6. auxInputType7(6) -+5V Supply Voltage 7. auxInputType8(7) -+3.3V Supply Voltage 8. auxInputType9(8) -+1.8V Supply Voltage 9. auxInputType10(9) --5.2V Supply Voltage 10. auxInputType11(10) -+5V Supply Current 11. auxInputType14(13) -+3.3V Supply Current 12. auxInputType15(14) -+1.8V Supply Current 13. auxInputType16(15) --5.2V Supply Current |
| I32 hw10GEOpticsMDCCEXT | 1.3.6.1.4.1.2011.5.14.6.3.1.79 | Integer32 | read-only | CC-EXT |
| OCT hw10GEOpticsMDVendorSpecific | 1.3.6.1.4.1.2011.5.14.6.3.1.80 | OCTET STRING | read-only | Vendor of 10GE Optical module specific information. |
| hwOpticsDdmInformationTable | 1.3.6.1.4.1.2011.5.14.6.4 | not-accessible | Indicates the optical module diagnose information table of an Ethernet port. It is used for querying the diagnose information about the optical module of an Ethernet port. The index of this table is ifindex. | |
| hwOpticsDdmInformationEntry | 1.3.6.1.4.1.2011.5.14.6.4.1 | not-accessible | Indicates the optical module diagnose information table of an Ethernet port. It is used for querying the diagnose information about the optical module of an Ethernet port. The index of this entry is ifindex. | |
| I32 hwOpticsTemperature | 1.3.6.1.4.1.2011.5.14.6.4.1.1 | Integer32 | read-only | Temperature. Unit: 0.000001C |
| I32 hwOpticsSupplyVoltage | 1.3.6.1.4.1.2011.5.14.6.4.1.2 | Integer32 | read-only | Supply voltage. Unit: 0.000001V |
| I32 hwOpticsTxBiasCurrent | 1.3.6.1.4.1.2011.5.14.6.4.1.3 | Integer32 | read-only | Transmitted bias current. Unit: 0.000001A |
| I32 hwOpticsTxPower | 1.3.6.1.4.1.2011.5.14.6.4.1.4 | Integer32 | read-only | Transmitted power. Unit: 0.000001dBm |
| I32 hwOpticsRxPower | 1.3.6.1.4.1.2011.5.14.6.4.1.5 | Integer32 | read-only | Received power. Unit: 0.000001dBm |
| INT hwOpticsMDDdmInfoRemote | 1.3.6.1.4.1.2011.5.14.6.4.1.6 | INTEGER | read-only | Indicates the operation is performed on a remote optical module. Options: 1. remote(1) -the operation is performed on a remote optical module 2. invalid(-1) -invalid value |
| hwOpticsPowerThresholdTable | 1.3.6.1.4.1.2011.5.14.6.5 | not-accessible | Indicates the optical power threshold table of an Ethernet port. It is used for querying, setting, and clearing the optical power threshold of an Ethernet port. After the power threshold is set, the power threshold alarming function of the optical port is enabled. When the optical power is lower than the lower threshold or higher than the upper threshold, an alarm is reported. The index of this table is ifindex. | |
| hwOpticsPowerThresholdEntry | 1.3.6.1.4.1.2011.5.14.6.5.1 | not-accessible | Indicates the optical power threshold table of an Ethernet port. It is used for querying, setting, and clearing the optical power threshold of an Ethernet port. After the power threshold is set, the power threshold alarming function of the optical port is enabled. When the optical power is lower than the lower threshold or higher than the upper threshold, an alarm is reported. The index of this entry is ifindex. | |
| I32 hwOpticsPowerThresholdValue | 1.3.6.1.4.1.2011.5.14.6.5.1.1 | Integer32 | read-write | TX optical power lower limit threshold value. Unit: 0.000001dBm |
| INT hwOpticsPowerThresholdSwitch | 1.3.6.1.4.1.2011.5.14.6.5.1.2 | INTEGER | read-write | Optical power threshold value Switch. Options: 1. on(1) -set optical power threshold value 2. off(2) -clear optical power threshold value 3. invalid(-1) -invalid value Default: off(2) |
| I32 hwOpticsPowerTxUpperThresholdValue | 1.3.6.1.4.1.2011.5.14.6.5.1.3 | Integer32 | read-write | TX optical power upper limit threshold value. Unit: 0.000001dBm |
| I32 hwOpticsPowerRxUpperThresholdValue | 1.3.6.1.4.1.2011.5.14.6.5.1.4 | Integer32 | read-write | RX optical power upper limit threshold value. Unit: 0.000001dBm |
| I32 hwOpticsPowerRxLowerThresholdValue | 1.3.6.1.4.1.2011.5.14.6.5.1.5 | Integer32 | read-write | RX optical power lower limit threshold value. Unit: 0.000001dBm |
| I32 hwOpticsTemperatureLowerThresholdValue | 1.3.6.1.4.1.2011.5.14.6.5.1.6 | Integer32 | read-write | Optical temperature lower limit threshold value. Unit: 0.01C |
| I32 hwOpticsTemperatureUpperThresholdValue | 1.3.6.1.4.1.2011.5.14.6.5.1.7 | Integer32 | read-write | Optical temperature upper limit threshold value. Unit: 0.01C |
| INT hwOpticsTemperatureThresholdSwitch | 1.3.6.1.4.1.2011.5.14.6.5.1.8 | INTEGER | read-write | Optical temperature threshold value Switch. Options: 1. on(1) -set optical temparature threshold value 2. off(2) -clear optical temperature threshold value 3. invalid(-1) -invalid value Default: off(2) |
| I32 hwOpticsVoltageLowerThresholdValue | 1.3.6.1.4.1.2011.5.14.6.5.1.9 | Integer32 | read-write | Optical voltage lower limit threshold value. Unit: 0.01V |
| I32 hwOpticsVoltageUpperThresholdValue | 1.3.6.1.4.1.2011.5.14.6.5.1.10 | Integer32 | read-write | Optical voltage upper limit threshold value. Unit: 0.01V |
| INT hwOpticsVoltageThresholdSwitch | 1.3.6.1.4.1.2011.5.14.6.5.1.11 | INTEGER | read-write | Optical voltage threshold value Switch. Options: 1. on(1) -set optical voltage threshold value 2. off(2) -clear optical voltage threshold value 3. invalid(-1) -invalid value Default: off(2) |
| I32 hwOpticsCurrentLowerThresholdValue | 1.3.6.1.4.1.2011.5.14.6.5.1.12 | Integer32 | read-write | Optical current lower limit threshold value. Unit: mA |
| I32 hwOpticsCurrentUpperThresholdValue | 1.3.6.1.4.1.2011.5.14.6.5.1.13 | Integer32 | read-write | Optical current upper limit threshold value. Unit: mA |
| INT hwOpticsCurrentThresholdSwitch | 1.3.6.1.4.1.2011.5.14.6.5.1.14 | INTEGER | read-write | Optical current threshold value Switch. Options: 1. on(1) -set optical current threshold value 2. off(2) -clear optical current threshold value 3. invalid(-1) -invalid value Default: off(2) |
| hwOpticsModuleTraps | 1.3.6.1.4.1.2011.5.14.6.6 | |||
| hwOpticsCommonTraps | 1.3.6.1.4.1.2011.5.14.6.6.1 | |||
| hwOpticsCommonTrapsPrefix | 1.3.6.1.4.1.2011.5.14.6.6.1.0 | |||
| hwOpticsAlarmTraps | 1.3.6.1.4.1.2011.5.14.6.6.2 | |||
| hwOpticsAlarmTrapsPrefix | 1.3.6.1.4.1.2011.5.14.6.6.2.0 | |||
| NTF hwOpticsTransceiverFaultyAlarmTrap | 1.3.6.1.4.1.2011.5.14.6.6.2.0.1 | This trap will send when the optical transceiver is faulty. | ||
| NTF hwOpticsPowerOutOfRangeAlarmTrap | 1.3.6.1.4.1.2011.5.14.6.6.2.0.2 | This trap will send when the Tx power of the Ethernet optical port is out of the range. | ||
| NTF hwOpticsPortTemperatureHighAlarmTrap | 1.3.6.1.4.1.2011.5.14.6.6.2.0.3 | This trap will send when the temperature of the Ethernet optical port is too high. | ||
| hwOpticsSmartSFPExtModuleInformationTable | 1.3.6.1.4.1.2011.5.14.6.7 | not-accessible | Indicates the extended information table of a smart SFP optical module. It is used for querying the extend information about a smart SFP optical module and setting loopback of a smart SFP optical module. This operation can be performed on both local and remote optical modules. When this operation is performed on a remote optical module, the hwOpticsSmartSFPExtModuleInfoRemote leaf is required. The index of this table is ifIndex. | |
| hwOpticsSmartSFPExtModuleInformationEntry | 1.3.6.1.4.1.2011.5.14.6.7.1 | not-accessible | Indicates the extended information table of a smart SFP optical module. It is used for querying the extend information about a smart SFP optical module and setting loopback of a smart SFP optical module. This operation can be performed on both local and remote optical modules. When this operation is performed on a remote optical module, the hwOpticsSmartSFPExtModuleInfoRemote leaf is required. The index of this entry is ifIndex. | |
| INT hwOpticsSmartSFPIdentifier | 1.3.6.1.4.1.2011.5.14.6.7.1.1 | INTEGER | read-only | Indicates the type of a smart SFP optical module. Options: 1. smartSFPI(1) -The optical module is a smart SFP I optical module 2. smartSFPII(2) -The optical module is a smart SFP II optical module 3. unknowType(3) -Unknown or unspecified type |
| I32 hwOpticsSmartSFPProtocolVersion | 1.3.6.1.4.1.2011.5.14.6.7.1.2 | Integer32 | read-only | Indicates the protocol version of a smart SFP optical module. Range: -1, 0-255. -1 is the invalid value. |
| I32 hwOpticsSmartSFPSSFPEnhancedOption | 1.3.6.1.4.1.2011.5.14.6.7.1.3 | Integer32 | read-only | Indicates the enhanced options of a smart SFP optical module. Range: -1, 0-65535. -1 is the invalid value. |
| U32 hwOpticsSmartSFPPassword | 1.3.6.1.4.1.2011.5.14.6.7.1.4 | Unsigned32 | read-only | Indicates the password of a smart SFP optical module. |
| INT hwOpticsSmartSFPRemoteControllable | 1.3.6.1.4.1.2011.5.14.6.7.1.5 | INTEGER | read-only | Indicates whether the remote smart SFP optical module can control the local optical module. Options: 1. disable(1) -disable, control command from remote optical module will be ignored 2. enable(2) -enable 3. invalid(-1) -invalid value |
| INT hwOpticsSmartSFPSubCarrierControl | 1.3.6.1.4.1.2011.5.14.6.7.1.6 | INTEGER | read-only | Indicates sub-carrier control of a smart SFP optical module, that is, whether the local smart SFP optical module can send signals to the remote optical module. Options: 1. disable(1) -disable 2. enable(2) -enable 3. invalid(-1) -invalid value |
| INT hwOpticsSmartSFPSubCarrierlinkStatus | 1.3.6.1.4.1.2011.5.14.6.7.1.7 | INTEGER | read-only | Indicates the sub-carrier status of a smart SFP optical module. Options: 1. down(1) -linked down 2. rxUp(2) -linked up in RX only 3. up(3) -linked up in both RX and TX direction 4. invalid(-1) -invalid value |
| INT hwOpticsSmartSFPLocalLoopback | 1.3.6.1.4.1.2011.5.14.6.7.1.8 | INTEGER | read-write | Indicates the loopback control of a local smart SFP optical module. Options: 1. noloop(1) -no loop 2. remote(2) -local outward loop back 3. local(3) -local inward loop back 4. invalid(-1) -invalid value |
| INT hwOpticsSmartSFPRemoteLoopback | 1.3.6.1.4.1.2011.5.14.6.7.1.9 | INTEGER | read-write | Indicates the loopback control of a remote smart SFP optical module. Options: 1. noloop(1) -no loop 2. remote(2) -remote outward loop back 3. invalid(-1) -invalid value |
| INT hwOpticsSmartSFPDyingGaspStatus | 1.3.6.1.4.1.2011.5.14.6.7.1.10 | INTEGER | read-write | Indicates the dying-gasp status of a remote smart SFP optical module. Options: 1. poweron(1) -remote normal power 2. poweroff(2) -remote Dying-Gasp asserted 3. invalid(-1) -invalid value |
| INT hwOpticsSmartSFPLocalRXOutputControl | 1.3.6.1.4.1.2011.5.14.6.7.1.11 | INTEGER | read-write | Indicates the local output control of a smart SFP optical module. Options: 1. disable(1) -disable 2. enable(2) -enable 3. disableRxLos(3) -disable when LOS asserted 4. invalid(-1) -invalid value |
| INT hwOpticsSmartSFPPilottoneControl | 1.3.6.1.4.1.2011.5.14.6.7.1.12 | INTEGER | read-write | Indicates control of outputting attenuation signals by a smart SFP optical module. Options: 1. disable(1) -disable 2. enable(2) -enable 3. invalid(-1) -invalid value |
| INT hwOpticsSmartSFPPilottoneStatus | 1.3.6.1.4.1.2011.5.14.6.7.1.13 | INTEGER | read-write | Indicates the carrier loopback detection status of a smart SFP optical module. Options: 1. noSignal(1) -no signal 2. toneDetected(2) -tone detected 3. invalid(-1) -invalid value |
| I32 hwOpticsSmartSFPLoopbackdeviceloss | 1.3.6.1.4.1.2011.5.14.6.7.1.14 | Integer32 | read-only | Indicates the optical attenuation of a remote loopback device. Range: -1, 0-25500. -1 is the invalid value. Unit: 0.01db |
| I32 hwOpticsSmartSFPRoundtripfiberloss | 1.3.6.1.4.1.2011.5.14.6.7.1.15 | Integer32 | read-only | Indicates the optical attenuation of an optical path. Range: -1, 0-25500. -1 is the invalid value. Unit: 0.01db |
| INT hwOpticsSmartSFPExtModuleInfoRemote | 1.3.6.1.4.1.2011.5.14.6.7.1.16 | INTEGER | read-only | Indicates the operation is performed on a remote optical module. Options: 1. remote(1) -the operation is performed on a remote optical module 2. invalid(-1) -invalid value |
| hwOpticsSmartSFPConfigTable | 1.3.6.1.4.1.2011.5.14.6.8 | not-accessible | Indicates the configured parameter table of a smart SFP optical module. It is used for querying and setting the configured parameters of a smart SFP optical module. This table supports only the smart SFP 2 optical module. The index of this table is ifIndex. | |
| hwOpticsSmartSFPConfigEntry | 1.3.6.1.4.1.2011.5.14.6.8.1 | not-accessible | Indicates the configured parameter table of a smart SFP optical module. It is used for querying and setting the configured parameters of a smart SFP optical module. This table supports only the smart SFP 2 optical module. The index of this entry is ifIndex. | |
| I32 hwOpticsSmartSFPIILoopOpticloss | 1.3.6.1.4.1.2011.5.14.6.8.1.1 | Integer32 | read-write | Indicates the optical attenuation of a remote loopback device. Unit: 0.01db. Range: -1, 0-25500. -1 is the invalid value. Default: 14000. |
RFC description
Ethernet optical module monitoring including SFP/XFP transceivers and optical performance metrics.
Start monitoring Huawei switch or router with pluggable optical transceivers (SFP/SFP+/QSFP DDM) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.