All MIBs › HP-ICF-8023-RPTR › hpRptrEntityName
hpRptrEntityName
Module: HP-ICF-8023-RPTR
OID (symbolic): HP-ICF-8023-RPTR::hpRptrEntityName
OID (numeric): 1.3.6.1.4.1.11.2.14.11.2.1.1.1
Node type: OBJECT-TYPE
Type: DisplayString
Access: read-only
Description: ********* THIS OBJECT IS DEPRECATED *********
The local name of this repeater. This is the same value as hpicfEntityName in the case where there is Distributed Management Protocol to access this device.
For SNMPv1, this name is appended to the agent community name to obtain a community name to use to specify that the agent should proxy to this repeater. For example, if this agent has a community with a community name of 'public', and the value of this object is 'repeater1', the community 'public/repeater1' will specify that the agent should proxy to the public community of the repeater1 box to obtain management information about this repeater.
If an agent receives a management request where the localEntity is not specified, it will default to the local repeater on which this agent is executing.
This object has been deprecated. Since it is a scalar, it does not scale to systems containing multiple repeater segments. In addition, it is only considered useful in systems supporting the Distributed Management Chain, which has also been deprecated.
What is hpRptrEntityName?
This deprecated read-only string (0-15 bytes) held the repeater's local name, historically appended to the SNMPv1 community string (e.g. 'public/repeater1') so an agent knew which repeater to proxy management requests to; it's obsolete now that Distributed Management Protocol chaining is no longer used.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.2.1.1.1 snmpwalk -v2c -c public <target> HP-ICF-8023-RPTR::hpRptrEntityName
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.2.1.1.1.1 snmpget -v2c -c public <target> HP-ICF-8023-RPTR::hpRptrEntityName.1
Start monitoring HP repeater/hub hardware with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HP-ICF-8023-RPTR::hpRptrEntityName OID value, configure state conditions and alerts, and monitor any HP repeater/hub hardware from a single console.
OID Breakdown
Upper-level ancestors (13 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.11 | hp | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2 | nm | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2.14 | icf | CONFIG-MIB |
| 1.3.6.1.4.1.11.2.14.11 | hpicfObjects | CONFIG-MIB |
| 1.3.6.1.4.1.11.2.14.11.2 | hpicfRepeater | HP-ICF |
| 1.3.6.1.4.1.11.2.14.11.2.1 | hpRptrBasic | HP-ICF |
| 1.3.6.1.4.1.11.2.14.11.2.1.1 | hpRptrBasicGlobal | HP-ICF |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.11.2.14.11.2.1.1.1 | hpRptrEntityName | HP-ICF-8023-RPTR |