HH3C-DOT11-ACMT-MIB

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › HH3C-DOT11-ACMT-MIB

Organization: Hangzhou H3C Technologies Co., Ltd.

Last Updated: 2010-08-04

Category: Technology: Wireless, Vendor: H3C/HH3C

Description: Manages 802.11 WLAN AC (Access Controller) measurement and statistics objects on H3C wireless controllers.

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is HH3C-DOT11-ACMT-MIB?

HH3C-DOT11-ACMT-MIB provides measurement and statistics objects for the IEEE 802.11 wireless LAN access-controller (AC) relationship with access points (APs) and their tunnels on H3C wireless controllers, per the module's own glossary of AP/AC terminology. It exposes scalar and table-based load statistics such as the current AC operating mode, maximum permitted AP and station counts, currently connected AP and station counts, and per-interface AP/station load broken out by interface name. Its monitoring value is centered on wireless infrastructure capacity and load: an administrator can see how close the controller is to its AP or client capacity ceiling and identify which specific AC interface is carrying the heaviest AP/station load, reflecting the operational health of the wireless control-plane rather than a single hardware component. It explicitly cross-references the standard Entity MIB (entPhysicalIndex) for detailed physical AP/AC hardware information, showing a deliberate dependency on that standard for deeper inventory detail. It is deployed on H3C wireless access controllers managing fleets of access points in enterprise or campus WLAN deployments, and the HH3C-DOT11-ACMT-MIB MIB is the reference used to poll these wireless capacity metrics.

IPNetwork Monitor allows you to monitor SNMP objects defined in HH3C-DOT11-ACMT-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • H3C wireless access controller (AC)
  • H3C-managed 802.11 access points

Monitoring Examples

An administrator would poll hh3cDot11APConnectCount and hh3cDot11StationConnectCount against hh3cDot11MaxAPNumPermitted and hh3cDot11MaxStationNumPermitted to see how close the AC is to its licensed or hardware capacity limits. The hh3cDot11ACIFLoadInfoTable, keyed by hh3cDot11ACIfIndex, exposes hh3cDot11ACIfApNum and hh3cDot11ACIfStaNum per hh3cDot11ACIfName, letting an operator spot a single tunnel interface carrying a disproportionate share of APs or stations. An hh3cDot11ACIfApNum approaching the AC-wide maximum on one interface while others are lightly loaded would suggest AP load-balancing across AC interfaces needs rebalancing.

What Can Be Monitored

  • current AC operating mode
  • maximum AP/station capacity
  • currently connected AP count
  • currently connected station count
  • per-interface AP and station load
  • master AP count
Imported Objects

From HH3C-DOT11-REF-MIB

Hh3cDot11MACModeType
Hh3cDot11ObjectIDType
Hh3cDot11TunnelSecSchemType
hh3cDot11MODULE-IDENTITY

From IANAifType-MIB

IANAifType

From SNMPv2-SMI

Counter32
Counter64
Integer32
IpAddress
MODULE-IDENTITY
NOTIFICATION-TYPE
OBJECT-TYPE
TimeTicks

How to Use in IPNetwork Monitor

Example using hh3cDot11AcUploadFrameCnt OID:

Select an H3C wireless access controller (AC capacity/AP-station load) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type hh3cDot11AcUploadFrameCnt into the Find box to locate it in the OID tree, then select it and click OK. Represents the number of frames that AP sends to AC through LWAPP tunnel. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter64-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.
OIDs

RFC description

Wireless access controller management including CAPWAP tunnel configuration and statistics.

Start monitoring H3C wireless access controller (AC capacity/AP-station load) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download HH3C-DOT11-ACMT-MIB