All MIBs › H3C-POWER-ETH-EXT-MIB
Organization: Organization.
Last Updated: 2004-07-26
Category: Technology: PoE, Vendor: H3C/HH3C
Description: H3C MIB extending Power over Ethernet (PoE) management with H3C-specific port power statistics and configuration.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is H3C-POWER-ETH-EXT-MIB?
H3C-POWER-ETH-EXT-MIB is an H3C proprietary extension to the standard Power over Ethernet MIB, adding H3C-specific per-port power statistics and configuration beyond what POWER-ETHERNET-MIB defines. Because no module description or sample objects were available for this MIB, the specific object set cannot be enumerated with certainty, but by convention such extension MIBs typically expose per-port power draw, power budget/threshold configuration, and PoE port enable/priority settings. In a monitoring context this class of MIB is generally used to track hardware power-delivery health on switch ports — actual power consumed versus the port or system power budget, and whether a port has exceeded its allocated power or entered a fault/overload state. It depends on and extends the IETF POWER-ETHERNET-MIB (RFC 3621), inheriting its base PoE port table structure. It is deployed on H3C access switches that supply inline power to devices such as IP phones, wireless access points, and PoE-powered cameras. Engineers can download the H3C-POWER-ETH-EXT-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in H3C-POWER-ETH-EXT-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- H3C PoE-capable Ethernet switches
Monitoring Examples
No sample objects were provided for this module, so a concrete object-level polling scenario cannot be constructed without inventing names; in practice, however, an administrator would typically extend the standard pethPsePortTable with H3C-specific power-draw counters to detect a port nearing its power budget or a PSE reporting an overload condition. This MIB should be treated as a PoE power-monitoring extension pending direct inspection of its object tree for exact table and column names.
What Can Be Monitored
- per-port PoE power consumption
- PoE power budget utilization
- PoE port power state/faults
This MIB depends on
Related MIBs
Imported Objects
From HUAWEI-3COM-OID-MIB
| h3cCommon | OBJECT-IDENTITY |
From POWER-ETHERNET-MIB
| pethMainPseGroupIndex | OBJECT-TYPE |
| pethPsePortDetectionStatus | OBJECT-TYPE |
| pethPsePortGroupIndex | OBJECT-TYPE |
| pethPsePortIndex | OBJECT-TYPE |
From SNMPv2-CONF
| MODULE-COMPLIANCE | |
| OBJECT-GROUP |
From SNMPv2-SMI
| Integer32 | |
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-TYPE |
From SNMPv2-TC
| DisplayString | |
| RowStatus |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| h3cPowerEthernetExt | 1.3.6.1.4.1.2011.10.2.14 | Description. | ||
| h3cPsePortTable | 1.3.6.1.4.1.2011.10.2.14.1 | not-accessible | The indexing scheme is taken form that used by the IETF Power MIB. The same indexing scheme is used to give continuity in behaviour between that standard and this extensions definitioin. | |
| h3cPsePortEntry | 1.3.6.1.4.1.2011.10.2.14.1.1 | not-accessible | The pethPsePortGroupIndex is imported from the IETF Power MIB and uniquely identifies the group containing the port to which power ethernet PSE is connected. Group means (box in the stack, module in a rack). The pethPsePortPowerIndex is imported from the IETF Power MIB and uniquely identifies the power ethernet PSE port within group pethPseGroupIndex to which the power Ethernet PSE entry is connected. This value will match the local port number on a switch. | |
| STR h3cPsePortFaultDescription | 1.3.6.1.4.1.2011.10.2.14.1.1.2 | DisplayString | read-write | The object supports the fault category of the IETF Power MIB [1] pethPsePortDetectionStatus object. A textual description containing more information about the nature of this fault is provided by this object. Typically this will detail the precise PoE hardware state which is causing the pethPsePortDetectionStatus object to be in the 'fault' state. It is a DisplayString of up to 255 characters. |
| I32 h3cPsePortPeakPower | 1.3.6.1.4.1.2011.10.2.14.1.1.3 | Integer32 | read-write | The object specifies the peak power which has been consumed by the port. It is defined as the highest measured value of power in milliWatts that has been consumed by the port. Its value is only reset when link is lost, the port is PoE disabled or when it is manually reset by the user asspecified below. It is a read/write integer value with units of milliWatts. Writing a value of zero to this object resets its value to zero. Writing any other value to this object has no effect on its value and an error is returned. |
| I32 h3cPsePortAveragePower | 1.3.6.1.4.1.2011.10.2.14.1.1.4 | Integer32 | read-write | The object specifies the average power which has been consumed by the port. This object is a read/write integer value with units of milliWatts. Writing a value of zero to this object resets its value to zero. Writing any other value to this object has no effect on its value and an error is returned. |
| I32 h3cPsePortCurrentPower | 1.3.6.1.4.1.2011.10.2.14.1.1.5 | Integer32 | read-only | The object specifies the power currently being consumed by the port. It is a read only integer value with units of milliWatts. |
| I32 h3cPsePortPowerLimit | 1.3.6.1.4.1.2011.10.2.14.1.1.6 | Integer32 | read-write | The object specifies the power limit set for this port. The PSE will not supply more than this level of power to the specified port. It is a read/write integer value with units of milliWatts. |
| I32 h3cPsePortProfileIndex | 1.3.6.1.4.1.2011.10.2.14.1.1.7 | Integer32 | read-write | Indicates the power profile which is currently associated with this port. This object references the corresponding h3cPseProfileIndex object in the power profiles table. A value of zero is a special case and indicates that no power profile is currently associated with this port. When h3cPseProfileIndex is set to an index of existent profile, pethPsePortPowerPairs, pethPsePortPowerPriority, pethPsePortAdminEnable and h3cPsePortPowerLimit will be set to the same as corresponding value. PethPsePortPowerPairs, pethPsePortPowerPriority and pethPsePortAdminEnable are objects of rfc3621-Power-Ethernet.mib. |
| h3cMainPseTable | 1.3.6.1.4.1.2011.10.2.14.2 | not-accessible | Description. | |
| h3cMainPseEntry | 1.3.6.1.4.1.2011.10.2.14.2.1 | not-accessible | The pethMainPseGroupIndex is imported from the IETF Power MIB and uniquely identifies the group containing the port to which power ethernet PSE is connected. Group means (box in the stack, module in a rack) and the value 1 MUST be used for non-modular devices. | |
| I32 h3cMainPsePowerLimit | 1.3.6.1.4.1.2011.10.2.14.2.1.1 | Integer32 | read-write | The object specifies the power limit set for the unit as a whole. The PoE unit will already have a nominal power defined by the IETF Power MIB [1] pethMainPsePower object. This OPTIONAL object specifies a further limit to this nominal power value. This may be useful to control the thermals of the unit, or for internal testing purposes. One possible use for this object may be to lower the power consumption of the unit if one or more of the internal fans have broken. It is a read/write integer value with units of Watts (note - Watts is chosen instead of milliWatts here since the IETF Power MIB [1] measures unit based parameters, such as the pethMainPsePower object, in units of Watts). |
| I32 h3cMainPseAveragePower | 1.3.6.1.4.1.2011.10.2.14.2.1.2 | Integer32 | read-write | The object specifies the average power which has been consumed by the port. It is a read/write integer value with units of Watts (note - Watts is chosen instead of milliWatts here since the IETF Power MIB [1] measures unit based parameters, such as the pethMainPsePower object, in units of Watts). Writing a value of zero to this object resets its value to zero. Writing any other value to this object has no effect on its value and an error is returned. |
| I32 h3cMainPsePeakPower | 1.3.6.1.4.1.2011.10.2.14.2.1.3 | Integer32 | read-write | The object specifies the peak power which has been consumed for PoE. It is defined as the highest measured value of power in milliWatts that has been consumed at any one point in time by the sum of the PoE ports. Its value is only reset when the unit is powered on or when it is manually reset by the user as specifiedbelow. It is a read/write integer value with units of Watts (note - Watts is chosen instead of milliWatts here since the IETF Power MIB [1] measures unit based parameters, such as the pethMainPsePower object, in units of Watts). Writing a value of zero to this object resets its value to zero. Writing any other value to this object has noeffect on its value and an error is returned. |
| I32 h3cMainGuaranteedPowerRemaining | 1.3.6.1.4.1.2011.10.2.14.2.1.4 | Integer32 | read-only | The object specifies the amount of power remaining in the guaranteed power pool. Each time a port is placed into guaranteed mode it reserves a set amount of power out of the total guaranteed power pool for the system. This intention of this object is to give the client of this MIB (whether that be the CLI or the Web interface or the end user) an indication of how many ports can still be placed into guaranteed mode. It is a read only integer value with units of Watts(note - Watts is chosen instead of milliWatts here since the IETF Power MIB [1] measures unit based parameters,such as the pethMainPsePower object, in units of Watts). |
| INT h3cMainPsePriorityMode | 1.3.6.1.4.1.2011.10.2.14.2.1.5 | INTEGER | read-write | Describes or controls the priority mode on slot which must be enabled firstly. When a new board is inserted, and the power is over-load, a value of disconnection(0) means that the power will stop supply to the low priority slot ; A value of non-disconnection(1) means that the slot still supply when a new board is inserted, and the power is over-load too. |
| INT h3cMainPseLegacy | 1.3.6.1.4.1.2011.10.2.14.2.1.6 | INTEGER | read-write | Describes or controls the legacy mode on slot which must be enabled firstly. Legacy mode: standard or nonstandard PD detection mode. |
| INT h3cMainPsePowerPriority | 1.3.6.1.4.1.2011.10.2.14.2.1.7 | INTEGER | read-write | Describes or controls the priority of the PSE. The priority will be used by the PSE policy to prevent from power overloading. If the priority of PSE is set to critical, the PSE will turn into guaranteed mode. The priority could be used by a control mechanism that prevents power overloading by disconnecting PSEs with lower power priority. PSEs that connect devices critical to the application should be set to higher priority. |
| INT h3cPseAutoDetectActive | 1.3.6.1.4.1.2011.10.2.14.3 | INTEGER | read-write | The object specifies whether the device auto-detection feature is active. If this object is set to Active, and a known powered device is detected, then the port will automatically switch to Auto-Guaranteed mode. This is a stackwide object (ie. it is not referenced by group index). |
| h3cPseComformance | 1.3.6.1.4.1.2011.10.2.14.4 | |||
| h3cPseCompliances | 1.3.6.1.4.1.2011.10.2.14.4.1 | |||
| h3cPseCompliance | 1.3.6.1.4.1.2011.10.2.14.4.1.1 | Description. | ||
| h3cPseGroup | 1.3.6.1.4.1.2011.10.2.14.4.2 | |||
| h3cPsePortGroup | 1.3.6.1.4.1.2011.10.2.14.4.2.1 | A collection of objects should be supported at the same time. | ||
| h3cMainPseGroup | 1.3.6.1.4.1.2011.10.2.14.4.2.2 | A collection of objects should be supported at the same time. | ||
| h3cPseScalarGroup | 1.3.6.1.4.1.2011.10.2.14.4.2.3 | A collection of scalar objects supported. | ||
| h3cPsePDNotificationGroup | 1.3.6.1.4.1.2011.10.2.14.4.2.4 | PD Change Notification. | ||
| h3cPseProfilesGroup | 1.3.6.1.4.1.2011.10.2.14.4.2.5 | A collection of objects should be supported at the same time. | ||
| h3cPOEPowerThresholdLimitGroup | 1.3.6.1.4.1.2011.10.2.14.4.2.6 | Power threshold limits group. | ||
| h3cPOEPowerSupInfoGroup | 1.3.6.1.4.1.2011.10.2.14.4.2.7 | The basic Power information group. | ||
| h3cPOEPowerDCOutStateGroup | 1.3.6.1.4.1.2011.10.2.14.4.2.8 | The DC out power state group. | ||
| h3cPOEPowerDCOutInfoGroup | 1.3.6.1.4.1.2011.10.2.14.4.2.9 | The power AC input switch information group | ||
| h3cPOEPowerACSwitchStateModuleGroup | 1.3.6.1.4.1.2011.10.2.14.4.2.10 | PD Change Notification. | ||
| h3cPOEPowerInCurStateGroup | 1.3.6.1.4.1.2011.10.2.14.4.2.11 | PD Change Notification. | ||
| h3cPOEPowerAlarmStateGroup | 1.3.6.1.4.1.2011.10.2.14.4.2.12 | PD Change Notification. | ||
| I32 h3cPsePowerMaxValue | 1.3.6.1.4.1.2011.10.2.14.5 | Integer32 | read-write | The object specifies the max poe power for lanswitch. The value should between the power currently and the max power. |
| h3cpseportNotification | 1.3.6.1.4.1.2011.10.2.14.6 | |||
| NTF h3cpsePDChangeNotification | 1.3.6.1.4.1.2011.10.2.14.6.1 | This notification indicates if PD has been inserted or pulled out. | ||
| NTF h3cPOEDisconnectNotification | 1.3.6.1.4.1.2011.10.2.14.6.2 | This notification indicates the POE power module does not disconnect. | ||
| NTF h3cPOEInputErrorNotification | 1.3.6.1.4.1.2011.10.2.14.6.3 | This notification indicates the POE power module input error. | ||
| NTF h3cPOEOutputErrorNotification | 1.3.6.1.4.1.2011.10.2.14.6.4 | This notification indicates the POE power module output error. | ||
| NTF h3cPOEOverVoltageNotification | 1.3.6.1.4.1.2011.10.2.14.6.5 | This notification indicates the POE power module overruns the voltage limit. | ||
| NTF h3cPOEOverTempNotification | 1.3.6.1.4.1.2011.10.2.14.6.6 | This notification indicates the POE power module overruns the temperature limit. | ||
| NTF h3cPOEFanErrorNotification | 1.3.6.1.4.1.2011.10.2.14.6.7 | This notification indicates the POE power module fan error. | ||
| NTF h3cPOEModuleShutdownNotification | 1.3.6.1.4.1.2011.10.2.14.6.8 | This notification indicates the POE power module is closed. | ||
| NTF h3cPOECurRestrictedNotification | 1.3.6.1.4.1.2011.10.2.14.6.9 | This notification indicates the POE power module current is restricted. | ||
| NTF h3cPOEACSwitchNotification | 1.3.6.1.4.1.2011.10.2.14.6.10 | This notification indicates the AC input switch alarm of this POE power. | ||
| NTF h3cPOEACInCurANotification | 1.3.6.1.4.1.2011.10.2.14.6.11 | This notification indicates the AC input current A alarm state of this POE power. | ||
| NTF h3cPOEACInCurBNotification | 1.3.6.1.4.1.2011.10.2.14.6.12 | This notification indicates the AC input current B alarm state of this POE power. | ||
| NTF h3cPOEACInCurCNotification | 1.3.6.1.4.1.2011.10.2.14.6.13 | This notification indicates the AC input current C alarm state of this POE power. | ||
| NTF h3cPOEACSwitchVolABNotification | 1.3.6.1.4.1.2011.10.2.14.6.14 | This notification indicates the AC input voltage AB alarm state of this POE power. | ||
| NTF h3cPOEACSwitchVolBCNotification | 1.3.6.1.4.1.2011.10.2.14.6.15 | This notification indicates the AC input voltage BC alarm state of this POE power. | ||
| NTF h3cPOEACSwitchVolCANotification | 1.3.6.1.4.1.2011.10.2.14.6.16 | This notification indicates the AC input voltage CA alarm state of this POE power. | ||
| NTF h3cPOEDCOutVolNotification | 1.3.6.1.4.1.2011.10.2.14.6.17 | This notification indicates the DC output alarm of this POE power. | ||
| NTF h3cPOEShutdownNotification | 1.3.6.1.4.1.2011.10.2.14.6.18 | This notification indicates the whole POE power has been shutdown. | ||
| h3cPseProfilesTable | 1.3.6.1.4.1.2011.10.2.14.7 | not-accessible | A table of objects representing a set of power profiles. Power profiles can be applied to PoE ports, which have the effect of automatically setting the priority, power limit and PoE enable MIB objects to the values specified in the power profile. | |
| h3cPseProfilesEntry | 1.3.6.1.4.1.2011.10.2.14.7.1 | not-accessible | A set of objects that display and control the Main power of a PSE. | |
| I32 h3cPseProfileIndex | 1.3.6.1.4.1.2011.10.2.14.7.1.1 | Integer32 | not-accessible | The index of the profile. This uniquely allow the profile to be identified. |
| STR h3cPseProfileName | 1.3.6.1.4.1.2011.10.2.14.7.1.2 | DisplayString | read-create | Assigns the profile a name with which the settings can be assiciated with. For example, 'NBX Phone'. |
| INT h3cPseProfilePowerMode | 1.3.6.1.4.1.2011.10.2.14.7.1.3 | INTEGER | read-create | The power mode associated with this power profile. There are two possible power modes as follows: powerDisabled, powerEnabled. When a power profile is applied to a PSE port, this value dictates the settings of the ports pethPsePortPowerPriority and pethPsePortAdminEnable objects. |
| I32 h3cPseProfilePowerLimit | 1.3.6.1.4.1.2011.10.2.14.7.1.4 | Integer32 | read-create | The power limit to be applied to the ports h3cPsePortPowerLimit object when the profile is applied to the PSE port. Expressed in milliWatts. |
| INT h3cPseProfilePriority | 1.3.6.1.4.1.2011.10.2.14.7.1.5 | INTEGER | read-create | This object controls the priority of the port from the point of view of a power management algorithm. The priority that is set by this variable could be used by a control mechanism that prevents over current situations by disconnecting first ports with lower power priority. Ports that connect devices critical to the operation of the network - like the E911 telephones ports - should be set to higher priority. |
| INT h3cPseProfilePairs | 1.3.6.1.4.1.2011.10.2.14.7.1.6 | INTEGER | read-create | Describes or controls the pairs in use. If the value of pethPsePortPowerPairsControl is true, this object is writable. A value of signal(1) means that the signal pairs only are in use. A value of spare(2) means that the spare pairs only are in use. |
| I32 h3cPseProfileApplyNum | 1.3.6.1.4.1.2011.10.2.14.7.1.7 | Integer32 | read-only | The number of this profile which has been applied. If h3cPseProfileApplyNum is not zero, user can't change the current line. |
| ROW h3cPseProfileRowStatus | 1.3.6.1.4.1.2011.10.2.14.7.1.8 | RowStatus | read-create | The status of this classifier. If h3cPseProfileApplyNum is not zero, user can't delete the current line. |
| h3cPOEPowerObjects | 1.3.6.1.4.1.2011.10.2.14.8 | |||
| h3cPOEThresholdLimitObjs | 1.3.6.1.4.1.2011.10.2.14.8.1 | |||
| OCT h3cPOEThresholdACMimimum | 1.3.6.1.4.1.2011.10.2.14.8.1.1 | OCTET STRING | read-write | Input threshold AC minimum. It is a read-write node. The value of this node is 'OCTET STRING', it is used to describe a float value. So this string should fit the following rule: 1. This string should be terminated by '\0'; 2. Every characters should be number or radix point; 3. The radix point should occur only once, and it should not be the first or the last character of the string. The value of this node should be smaller than 264.0V and larger than 90.0V. And it should be smaller than the h3cPOEThresholdACMaximum. |
| OCT h3cPOEThresholdACMaximum | 1.3.6.1.4.1.2011.10.2.14.8.1.2 | OCTET STRING | read-write | Input threshold AC maximum. It is a read-write node. The value of this node is 'OCTET STRING', it is used to describe a float value. So this string should fit the following rule: 1. This string should be terminated by '\0'; 2. Every characters should be number or radix point; 3. The radix point should occur only once, and it should not be the first or the last character of the string. It should be smaller than 264.0V and larger than 90.0V. And it should be larger than the h3cPOEThresholdACMinimum. |
| OCT h3cPOEThresholdDCMinimum | 1.3.6.1.4.1.2011.10.2.14.8.1.3 | OCTET STRING | read-write | Input threshold DC minimum. It is a read-write node. The value of this node is 'OCTET STRING', it is used to describe a float value. So this string should fit the following rule: 1. This string should be terminated by '\0'; 2. Every characters should be number or radix point; 3. The radix point should occur only once, and it should not be the first or the last character of the string. It should be smaller than 47.0V and larger than 45.0V. |
| OCT h3cPOEThresholdDCMaximum | 1.3.6.1.4.1.2011.10.2.14.8.1.4 | OCTET STRING | read-write | Input threshold DC maximum. It is a read-write node. The value of this node is 'OCTET STRING', it is used to describe a float value. So this string should fit the following rule: 1. This string should be terminated by '\0'; 2. Every characters should be number or radix point; 3. The radix point should occur only once, and it should not be the first or the last character of the string. It should be smaller than 57.0V and larger than 55.0V. |
| h3cPOESupModuleInfoObjs | 1.3.6.1.4.1.2011.10.2.14.8.2 | |||
| OCT h3cPOEPowerType | 1.3.6.1.4.1.2011.10.2.14.8.2.1 | OCTET STRING | read-only | The type of the power. |
| I32 h3cPOEPowerModuleNum | 1.3.6.1.4.1.2011.10.2.14.8.2.2 | Integer32 | read-only | The number of the power modules. |
| OCT h3cPOESupervisionModuleName | 1.3.6.1.4.1.2011.10.2.14.8.2.3 | OCTET STRING | read-only | The object specifies the Supervision Module name on this POE power. |
| I32 h3cPOESMMajorVersion | 1.3.6.1.4.1.2011.10.2.14.8.2.4 | Integer32 | read-only | The object specifies the high byte of the monitor module version. |
| I32 h3cPOESMMinorVersion | 1.3.6.1.4.1.2011.10.2.14.8.2.5 | Integer32 | read-only | The object specifies the low byte of the monitor module version. |
| OCT h3cPOESMFactorName | 1.3.6.1.4.1.2011.10.2.14.8.2.6 | OCTET STRING | read-only | The object specifies the name of the manufactor. |
| h3cPOEModuleInfoTable | 1.3.6.1.4.1.2011.10.2.14.8.2.7 | not-accessible | The table of the module information on this POE power. | |
| h3cPOEModuleInfoEntry | 1.3.6.1.4.1.2011.10.2.14.8.2.7.1 | not-accessible | The entry of the module information on this POE power. | |
| I32 h3cPOEModuleIndex | 1.3.6.1.4.1.2011.10.2.14.8.2.7.1.1 | Integer32 | accessible-for-notify | The index of the current module on this POE power. It is also the index of h3cPOEModuleInfoTable. The range of this node is from 1 to h3cPOEPowerModuleNum. |
| I32 h3cPOEModuleID | 1.3.6.1.4.1.2011.10.2.14.8.2.7.1.2 | Integer32 | read-only | The ID of the current module on this POE power. |
| I32 h3cPOEModuleInfoPower | 1.3.6.1.4.1.2011.10.2.14.8.2.7.1.3 | Integer32 | read-only | The power of the current module on this POE power. |
| OCT h3cPOEModuleHardVerInfo | 1.3.6.1.4.1.2011.10.2.14.8.2.7.1.4 | OCTET STRING | read-only | The hardware version information of the current module on this POE power. |
| h3cPOEDCOutStateObjects | 1.3.6.1.4.1.2011.10.2.14.8.3 | |||
| I32 h3cPOEDCOutStateModuleNum | 1.3.6.1.4.1.2011.10.2.14.8.3.1 | Integer32 | read-only | The module number on this POE power. It is the maximum of the h3cPOEDCOutStateIndex. |
| h3cPOEDCOutStateTable | 1.3.6.1.4.1.2011.10.2.14.8.3.2 | not-accessible | The table of DC output power state on this POE power. | |
| h3cPOEDCOutStateEntry | 1.3.6.1.4.1.2011.10.2.14.8.3.2.1 | not-accessible | The entry of the DC output power state on this POE power. | |
| I32 h3cPOEDCOutStateIndex | 1.3.6.1.4.1.2011.10.2.14.8.3.2.1.1 | Integer32 | accessible-for-notify | The index of the DC output power state on this POE power. The range of this node is from 1 to h3cPOEDCOutStateModuleNum. |
| DCA h3cPOEDCOutDCVolAlarm | 1.3.6.1.4.1.2011.10.2.14.8.3.2.1.2 | DCAlarmState | read-only | The DC output alarm of the DC output power state on this POE power. The value of this node will be the following values: normal (1), underLimit (2), aboveLimit (3), fuseBroken (4), switchOff (5), otherError (6). |
| h3cPOEDCOutInfoObjects | 1.3.6.1.4.1.2011.10.2.14.8.4 | |||
| I32 h3cPOEDCOutCurNum | 1.3.6.1.4.1.2011.10.2.14.8.4.1 | Integer32 | read-only | The number of DC output current on this POE power. It is the maximum of h3cPOEDCOutInfoIndex. |
| h3cPOEDCOutInfoTable | 1.3.6.1.4.1.2011.10.2.14.8.4.2 | not-accessible | The table of the DC output information on this POE power. | |
| h3cPOEDCOutInfoEntry | 1.3.6.1.4.1.2011.10.2.14.8.4.2.1 | not-accessible | The entry of the DC output information on this POE power. | |
| I32 h3cPOEDCOutInfoIndex | 1.3.6.1.4.1.2011.10.2.14.8.4.2.1.1 | Integer32 | accessible-for-notify | The index of the DC output information on this POE POWER. The range of this node is from 1 to h3cPOEDCOutCurNum. |
| OCT h3cPOEDCOutVol | 1.3.6.1.4.1.2011.10.2.14.8.4.2.1.2 | OCTET STRING | read-only | The DC output voltage of the current DC output on this POE power. |
| OCT h3cPOEDCOutInfoLoadCur | 1.3.6.1.4.1.2011.10.2.14.8.4.2.1.3 | OCTET STRING | read-only | The total load current of the current DC output on this POE power. |
| h3cPOEACSwitchStateModuleObjs | 1.3.6.1.4.1.2011.10.2.14.8.5 | |||
| I32 h3cPOEACSwitchStateModuleNum | 1.3.6.1.4.1.2011.10.2.14.8.5.1 | Integer32 | read-only | The number of the AC swtich state module on this POE power. It is the maximum of h3cPOEACSwitchStateIndex. |
| h3cPOEACSwitchStateTable | 1.3.6.1.4.1.2011.10.2.14.8.5.2 | not-accessible | The table of the AC switch state on this POE power. | |
| h3cPOEACSwitchStateEntry | 1.3.6.1.4.1.2011.10.2.14.8.5.2.1 | not-accessible | The entry of the AC switch state on this POE power. | |
| I32 h3cPOEACSwitchStateIndex | 1.3.6.1.4.1.2011.10.2.14.8.5.2.1.1 | Integer32 | accessible-for-notify | The index of the AC switch state on this POE power. The range of this node is from 1 to h3cPOEACSwitchStateModuleNum. |
| SWI h3cPOEACSwitchState | 1.3.6.1.4.1.2011.10.2.14.8.5.2.1.2 | SwitchState | read-only | The AC switch state on this POE power. The value of this node will be one of the following values: on (1), off (2), highVoltInput (3), lowVoltInput (4) |
| h3cPOEInCurStateObjects | 1.3.6.1.4.1.2011.10.2.14.8.6 | |||
| I32 h3cPOEInCurStateModuleNum | 1.3.6.1.4.1.2011.10.2.14.8.6.1 | Integer32 | read-only | The DC input current state of the module on this POE power. It is the maximum of the h3cPOESwitchStateVolExIndex. |
| ACA h3cPOEInCurAState | 1.3.6.1.4.1.2011.10.2.14.8.6.2 | ACAlarmState | read-only | The current A state in the DC input on this POE power. normal (1), underLimit (2), aboveLimit (3), lackPhrase (4), fuseBroken (5), switchOff (6), otherError (7). |
| ACA h3cPOEInCurBState | 1.3.6.1.4.1.2011.10.2.14.8.6.3 | ACAlarmState | read-only | The current B state in the DC input on this POE power. The value of this node will be one of the following values: normal (1), underLimit (2), aboveLimit (3), lackPhrase (4), fuseBroken (5), switchOff (6), otherError (7). |
| ACA h3cPOEInCurCState | 1.3.6.1.4.1.2011.10.2.14.8.6.4 | ACAlarmState | read-only | The current C state in the DC input on this POE power. The value of this node will be one of the following values: normal (1), underLimit (2), aboveLimit (3), lackPhrase (4), fuseBroken (5), switchOff (6), otherError (7). |
| h3cPOESwitchStateVolExTable | 1.3.6.1.4.1.2011.10.2.14.8.6.5 | not-accessible | All alarm status of the VOL status. The value of this node will be one of the following values: normal (1), underLimit (2), aboveLimit (3), lackPhrase (4), fuseBroken (5), switchOff (6), otherError (7). | |
| h3cPOESwitchStateVolExEntry | 1.3.6.1.4.1.2011.10.2.14.8.6.5.1 | not-accessible | The h3cPOESwitchStateVolExIndex will match the number of the VOL status. | |
| I32 h3cPOESwitchStateVolExIndex | 1.3.6.1.4.1.2011.10.2.14.8.6.5.1.1 | Integer32 | accessible-for-notify | The object species the index of the VOL status. The range of this node is from 1 to h3cPOEInCurStateModuleNum. |
| ACA h3cPOESwitchStateInVolAB | 1.3.6.1.4.1.2011.10.2.14.8.6.5.1.2 | ACAlarmState | read-only | The object specifies the VOL AB alarm in each VOL status. The value of this node will be one of the following values: normal (1), underLimit (2), aboveLimit (3), lackPhrase (4), fuseBroken (5), switchOff (6), otherError (7). |
| ACA h3cPOESwitchStateInVolBC | 1.3.6.1.4.1.2011.10.2.14.8.6.5.1.3 | ACAlarmState | read-only | The object specifies the VOL BC alarm in each VOL status. The value of this node will be one of the following values: normal (1), underLimit (2), aboveLimit (3), lackPhrase (4), fuseBroken (5), switchOff (6), otherError (7). |
| ACA h3cPOESwitchStateInVolCA | 1.3.6.1.4.1.2011.10.2.14.8.6.5.1.4 | ACAlarmState | read-only | The object specifies the VOL CA alarm in each VOL status. The value of this node will be one of the following values: normal (1), underLimit (2), aboveLimit (3), lackPhrase (4), fuseBroken (5), switchOff (6), otherError (7). |
| h3cPOEAlarmStateObjects | 1.3.6.1.4.1.2011.10.2.14.8.7 | |||
| I32 h3cPOEAlarmStateModuleNum | 1.3.6.1.4.1.2011.10.2.14.8.7.1 | Integer32 | read-only | The object specifies the number of the power modules in alarm state. |
| h3cPOEAlarmStateInfoTable | 1.3.6.1.4.1.2011.10.2.14.8.7.2 | not-accessible | All alarm states in the POE power modules. | |
| h3cPOEAlarmStateInfoEntry | 1.3.6.1.4.1.2011.10.2.14.8.7.2.1 | not-accessible | The h3cPOEAlarmModuleInfoIndex will match the number of the power module. | |
| I32 h3cPOEAlarmModuleInfoIndex | 1.3.6.1.4.1.2011.10.2.14.8.7.2.1.1 | Integer32 | accessible-for-notify | The index specifies the index of the H3cPOEAlarmStateInfoEntry table. The range of this node is from 1 to h3cPOEAlarmStateModuleNum. |
| MOD h3cPOEModuleDisconnect | 1.3.6.1.4.1.2011.10.2.14.8.7.2.1.2 | ModuleAlarmState | read-only | The node specifies the alarm state: The module does not link. The value of this node is one of the following values: normal (1), alarm (2). |
| MOD h3cPOEModuleInputError | 1.3.6.1.4.1.2011.10.2.14.8.7.2.1.3 | ModuleAlarmState | read-only | The node specifies the alarm state: Input error. The value of this node is one of the following values: normal (1), alarm (2). |
| MOD h3cPOEModuleOutputError | 1.3.6.1.4.1.2011.10.2.14.8.7.2.1.4 | ModuleAlarmState | read-only | The node specifies the alarm state: Output error. The value of this node is one of the following values: normal (1), alarm (2). |
| MOD h3cPOEModuleOverVoltage | 1.3.6.1.4.1.2011.10.2.14.8.7.2.1.5 | ModuleAlarmState | read-only | The node specifies the alarm state: The voltage is too high. The value of this node is one of the following values: normal (1), alarm (2). |
| MOD h3cPOEModuleOverTemp | 1.3.6.1.4.1.2011.10.2.14.8.7.2.1.6 | ModuleAlarmState | read-only | The node specifies the alarm state: The temperature is too high. The value of this node is one of the following values: normal (1), alarm (2). |
| MOD h3cPOEModuleFanError | 1.3.6.1.4.1.2011.10.2.14.8.7.2.1.7 | ModuleAlarmState | read-only | The node specifies the alarm state: The fan error. The value of this node is one of the following values: normal (1), alarm (2). |
| MOD h3cPOEModuleShutdown | 1.3.6.1.4.1.2011.10.2.14.8.7.2.1.8 | ModuleAlarmState | read-only | The node specifies the alarm state: The module is shutdown. The value of this node is one of the following values: normal (1), alarm (2). |
| MOD h3cPOEModuleCurRestricted | 1.3.6.1.4.1.2011.10.2.14.8.7.2.1.9 | ModuleAlarmState | read-only | The node specifies the alarm state: The module limit the current. The value of this node is one of the following values: normal (1), alarm (2). |
| INT h3cPsePolicyMode | 1.3.6.1.4.1.2011.10.2.14.9 | INTEGER | read-write | The PSE policy only applies to the situation that when a new board (PSE) is inserted, and the power is overload. A value of priority(2) means that the power will stop supplying to the low priority PSE. About PSE priority, please refer to h3cMainPsePowerPriority. A value of disabled(1) means that the power will stop supplying to the new inserted PSE. The default value of this object is disabled(1). |
| INT h3cPDPolicyMode | 1.3.6.1.4.1.2011.10.2.14.10 | INTEGER | read-write | The PD policy only applies to the situation that when a new PD is inserted, and the power of PSE is overload. A value of priority(2) means that the power will stop supplying to the low priority port PD. About port priority, please refer to pethPsePortPowerPriority. A value of disabled(1) means that the slot stop supplying to the new inserted PD. The default value of this object is disabled(1). |
RFC description
Power over Ethernet (PoE) extension for H3C/Huawei switches with port and PSE management.
Start monitoring H3C PoE-capable Ethernet switch (extended per-port power reporting) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.