All MIBs › GUDEADS-PDU8310-MIB
Organization: Gude Analog- und Digitalsysteme GmbH
Last Updated: 2007-03-05
Category: Domain: Power/UPS, Vendor: Gude
Description: Covers management of the Gude PDU8310, a high-density rack power distribution unit, including metering and outlet control.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is GUDEADS-PDU8310-MIB?
GUDEADS-PDU8310-MIB is Gude Analog- und Digitalsysteme's proprietary MIB for the PDU8310, a high-density rack-mounted power distribution unit with per-outlet metering and control. It exposes hardware power data down to the channel level, including current, voltage, active power, and accumulated active energy per outlet, plus per-channel on/off status and device configuration objects. This makes it a straightforward hardware power-health MIB: pdu8310Current, pdu8310Voltage, pdu8310ActivePowerChan, and pdu8310EnergyActive let an administrator watch real-time load and cumulative energy consumption, while pdu8310ChanStatus reveals whether an individual outlet is on, off, or tripped. It also defines trap destination configuration (pdu8310TrapIPTable/pdu8310TrapIPEntry, pdu8310TrapCtrl) and an events group for alerting, and is a self-contained vendor MIB with no strong dependency on other standard MIBs. It is deployed in data centers and equipment racks wherever Gude PDU8310 units provide metered, remotely switchable power distribution to rack-mounted servers and network gear, making GUDEADS-PDU8310-MIB SNMP monitoring a standard tool for tracking per-outlet load and energy use.
IPNetwork Monitor allows you to monitor SNMP objects defined in GUDEADS-PDU8310-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Gude PDU8310 rack power distribution unit
Monitoring Examples
An operator would poll pdu8310PowerTable/pdu8310PowerEntry, indexed by pdu8310PowerIndex, to read pdu8310Current, pdu8310Voltage, and pdu8310ActivePowerChan for each outlet, spotting an overloaded circuit when current climbs toward the PDU's rated limit. pdu8310EnergyActive gives cumulative energy draw useful for capacity planning or billing, while pdu8310ChanStatus confirms whether a given outlet is actually delivering power after a remote switch command. pdu8310TrapIPTable and pdu8310TrapCtrl would be checked when configuring where the PDU sends its power-fault event traps.
What Can Be Monitored
- per-outlet current and voltage
- per-outlet active power
- cumulative active energy
- outlet channel on/off status
- trap destination configuration
Imported Objects
From SNMPv2-CONF
| NOTIFICATION-GROUP | |
| OBJECT-GROUP |
From SNMPv2-SMI
| Integer32 | |
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-TYPE | |
| Unsigned32 | |
| enterprises |
OIDs
RFC description
Gude PDU8310 MIB for managing a high-density rack power distribution unit with metering and outlet control.
Start monitoring Gude PDU8310 rack power distribution unit with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.