GUDEADS-PDU8110-MIB

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › GUDEADS-PDU8110-MIB

Organization: Gude Analog- und Digitalsysteme GmbH

Last Updated: 2007-03-05

Category: Domain: Power/UPS, Vendor: Gude

Description: Gude PDU8110 MIB for monitoring a managed rack PDU including per-outlet current, power, and switching control.

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is GUDEADS-PDU8110-MIB?

This is a vendor-specific MIB from Gude Analog- und Digitalsysteme for its PDU8110 series of network-managed rack power distribution units (PDUs). It exposes per-outlet and overall power metrics, sensor readings, and outlet switching controls, alongside a table for configuring trap destinations. Administrators use it to monitor hardware status directly: per-channel current and active power draw, channel on/off/switching state, and connected environmental sensor values (such as temperature or humidity probes attached to the PDU), which together reveal overload conditions, failing outlets, or environmental excursions in the rack. It is a self-contained proprietary MIB with no unusual dependency beyond standard SNMP conventions (SNMPv2-SMI, TRAP-TYPE). It is typically deployed in data center and server room racks, where GUDEADS-PDU8110-MIB SNMP monitoring gives the PDU8110 remote power monitoring and outlet-level control for connected equipment.

IPNetwork Monitor allows you to monitor SNMP objects defined in GUDEADS-PDU8110-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • Gude PDU8110 rack power distribution unit (managed PDU)

Monitoring Examples

An operator polls pdu8110PowerTable/pdu8110PowerEntry entries indexed by pdu8110PowerIndex to read pdu8110Current and pdu8110ActivePowerChan for each pdu8110PowerChan, catching a channel whose current draw creeps toward the PDU's rated limit before a breaker trips. The pdu8110ChanStatus object shows whether an individual outlet is switched on, off, or in a fault state, letting an admin confirm a remote power-cycle command took effect. The pdu8110SensorTable (pdu8110SensorEntry/pdu8110SensorIndex) reports attached environmental sensor readings, while pdu8110TrapIPTable/pdu8110TrapIPEntry configures which management stations receive SNMP traps for these events.

What Can Be Monitored

  • per-outlet current
  • per-outlet active power
  • outlet switch/channel status
  • environmental sensor readings
  • trap destination configuration
Imported Objects

From SNMPv2-CONF

NOTIFICATION-GROUP
OBJECT-GROUP

From SNMPv2-SMI

Integer32
MODULE-IDENTITY
NOTIFICATION-TYPE
OBJECT-TYPE
Unsigned32
enterprises
OIDs

RFC description

Monitors power distribution unit channels on Gude Analog- und Digitalsysteme PDU8110 including current measurements.

Start monitoring Gude PDU8110 rack power distribution unit with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download GUDEADS-PDU8110-MIB