GMPLS-TE-STD-MIB :: gmplsTunnelCHopExplicitReverseLabelPtr

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › GMPLS-TE-STD-MIB › gmplsTunnelCHopExplicitReverseLabelPtr

gmplsTunnelCHopExplicitReverseLabelPtr

Module: GMPLS-TE-STD-MIB

OID (symbolic): GMPLS-TE-STD-MIB::gmplsTunnelCHopExplicitReverseLabelPtr

OID (numeric): 1.3.6.1.2.1.10.166.13.2.4.1.5

Node type: OBJECT-TYPE

Type: RowPointer

Access: read-only

Description: If the gmplsTunnelCHopLabelStatuses object indicates that a Reverse Label is present, this object contains a pointer to a row in another MIB table (such as the gmplsLabelTable of GMPLS-LABEL-STD-MIB) that contains the label to use on this hop in the reverse direction.

If the gmplsTunnelCHopLabelStatuses object indicates that a Reverse Label is present and this object contains the value zeroDotZero, then the label to use on this hop is found in the gmplsTunnelCHopExplicitReverseLabel object.

What is gmplsTunnelCHopExplicitReverseLabelPtr?

Points to a row in another MIB table (such as gmplsLabelTable in GMPLS-LABEL-STD-MIB) holding the reverse-direction label the path-computation engine assigned to this computed hop; if zeroDotZero, the label is found instead in gmplsTunnelCHopExplicitReverseLabel.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.2.1.10.166.13.2.4.1.5
snmpwalk -v2c -c public <target> GMPLS-TE-STD-MIB::gmplsTunnelCHopExplicitReverseLabelPtr

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.2.1.10.166.13.2.4.1.5.1
snmpget -v2c -c public <target> GMPLS-TE-STD-MIB::gmplsTunnelCHopExplicitReverseLabelPtr.1

Start monitoring Vendor-neutral GMPLS-capable optical/packet transport router or switch, any manufacturer (Traffic Engineering, RFC 4802) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the GMPLS-TE-STD-MIB::gmplsTunnelCHopExplicitReverseLabelPtr OID value, configure state conditions and alerts, and monitor any Vendor-neutral GMPLS-capable optical/packet transport router or switch, any manufacturer (Traffic Engineering, RFC 4802) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.2mgmtAPERTUS-NPG-MIB
1.3.6.1.2.1mib_2AXON-MIB
1.3.6.1.2.1.10transmissionCHECKPOINT-MIB-2
1.3.6.1.2.1.10.166mplsStdMIBMPLS-TC-PRIV-STDEXT-MIB
Numeric OIDNameModule
1.3.6.1.2.1.10.166.13gmplsTeStdMIBGMPLS-TE-STD-MIB
1.3.6.1.2.1.10.166.13.2gmplsTeObjectsGMPLS-TE-STD-MIB
1.3.6.1.2.1.10.166.13.2.4gmplsTunnelCHopTableGMPLS-TE-STD-MIB
1.3.6.1.2.1.10.166.13.2.4.1gmplsTunnelCHopEntryGMPLS-TE-STD-MIB
1.3.6.1.2.1.10.166.13.2.4.1.5gmplsTunnelCHopExplicitReverseLabelPtrGMPLS-TE-STD-MIB