All MIBs › FD-PERFORMANCE-MIB › onuUniThresholdLo
onuUniThresholdLo
Module: FD-PERFORMANCE-MIB
OID (symbolic): FD-PERFORMANCE-MIB::onuUniThresholdLo
OID (numeric): 1.3.6.1.4.1.34592.1.3.5.1.3.1.2
Node type: OBJECT-TYPE
Type: Counter32
Access: read-write
Description:
What is onuUniThresholdLo?
A read-write alarm floor for this ONU's UNI (subscriber-facing) port, set per performance-counter type (the row's statsId selects which counter -- octets, frames, CRC errors, dropped frames, bandwidth, etc.); an admin tunes this value so the agent raises an alarm when the selected counter's rate goes below it. The DESCRIPTION in this source MIB is just a placeholder (blank or the literal word "Description.") for this and nearly every other object here, so this reading is inferred from the object name, its table index, and standard EPON/GPON terminology.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.34592.1.3.5.1.3.1.2 snmpwalk -v2c -c public <target> FD-PERFORMANCE-MIB::onuUniThresholdLo
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.34592.1.3.5.1.3.1.2.1 snmpget -v2c -c public <target> FD-PERFORMANCE-MIB::onuUniThresholdLo.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.34592.1.3.5.1.3.1.2.1 i <value>
Start monitoring C-Data FD-series OLT/ONU (performance monitoring) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the FD-PERFORMANCE-MIB::onuUniThresholdLo OID value, configure state conditions and alerts, and monitor any C-Data FD-series OLT/ONU (performance monitoring) from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.34592 | vendor | CDATA-COMMON-SMI |
| 1.3.6.1.4.1.34592.1 | ipProduct | CDATA-COMMON-SMI |
| 1.3.6.1.4.1.34592.1.3 | epon | CDATA-COMMON-SMI |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.34592.1.3.5 | performance | FD-PERFORMANCE-MIB |
| 1.3.6.1.4.1.34592.1.3.5.1 | alarmThreshHold | FD-PERFORMANCE-MIB |
| 1.3.6.1.4.1.34592.1.3.5.1.3 | onuUniThresholdTable | FD-PERFORMANCE-MIB |
| 1.3.6.1.4.1.34592.1.3.5.1.3.1 | onuUniThresholdEntry | FD-PERFORMANCE-MIB |
| 1.3.6.1.4.1.34592.1.3.5.1.3.1.2 | onuUniThresholdLo | FD-PERFORMANCE-MIB |