ERICSSON-ALARM-MIB :: eriAlarmCleared

MIB Reference — IPNetwork Monitor · Updated September 21, 2026

All MIBs › ERICSSON-ALARM-MIB › eriAlarmCleared

eriAlarmCleared

Module: ERICSSON-ALARM-MIB

OID (symbolic): ERICSSON-ALARM-MIB::eriAlarmCleared

OID (numeric): 1.3.6.1.4.1.193.183.4.2.0.7

Node type: NOTIFICATION-TYPE

Description: This notification is sent when a resource detects a cleared alarm state. The combination of ManagedObject and MajorType/MinorType is always unique and shall be used by management systems to correlate alarm and alarm clear. The corresponding row in the alarm table will be deleted, (eriAlarmActiveAlarmTable). The sequence number will increase for every notification and can be used to detect lost notifications. A management system should be prepared for appending text to additional text, indicated by the eriAlarmNObjMoreAdditionalText varbind, and sent with eriAlarmAppendInfo. (Note do not confuse this with a change of additional text).

A management system should also be prepared to receive a resource ID (OID) identifying the alarming resource if the system sending the notification can provide that information. In that case, eriAlarmNObjResourceId will be set to 'true' and the resource ID will be sent in an eriAlarmAppendInfo notification.

A management system should also be prepared to receive a resource ID (OID) identifying the alarming resource if the system sending the notification can provide that information. In that case, eriAlarmNObjResourceId will be set to 'true' and the resource ID will be sent in an eriAlarmAppendInfo notification.

Examples

Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):

snmptrap -v2c -c public <manager> '' ERICSSON-ALARM-MIB::eriAlarmCleared
snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.193.183.4.2.0.7

Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):

snmptrapd -f -Lo -c /dev/null authCommunity log public

Example snmptrapd log entry:

zoo11-linux.zoo [UDP: [192.168.30.111]:51278->[192.168.30.10]:162]:
  DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (490774606) 56 days, 19:15:46.06
  SNMPv2-MIB::snmpTrapOID.0 = OID: ERICSSON-ALARM-MIB::eriAlarmCleared

Start monitoring Ericsson telecom network element (radio/core/transport, enterprise-wide alarm MIB) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ERICSSON-ALARM-MIB::eriAlarmCleared OID value, configure state conditions and alerts, and monitor any Ericsson telecom network element (radio/core/transport, enterprise-wide alarm MIB) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.193ericssonANS-COMMON-MIB
1.3.6.1.4.1.193.183atsAxd301Comm-OMS
1.3.6.1.4.1.193.183.4axd301PchAXD301-PCH-MIB
1.3.6.1.4.1.193.183.4.2atmVclVpiAXD301-PCH-MIB
Numeric OIDNameModule
1.3.6.1.4.1.193.183.4.2.0eriAlarmNotifsPrefixERICSSON-ALARM-MIB
1.3.6.1.4.1.193.183.4.2.0.7eriAlarmClearedERICSSON-ALARM-MIB