DOCS-RPHY-PTP-MIB :: docsRphyPtpCcapTimePropertiesCurrentUtcOffsetValid

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsDOCS-RPHY-PTP-MIBdocsRphyPtpCcapTimePropertiesCurrentUtcOffsetValid

docsRphyPtpCcapTimePropertiesCurrentUtcOffsetValid

Module: DOCS-RPHY-PTP-MIB

OID (symbolic): DOCS-RPHY-PTP-MIB::docsRphyPtpCcapTimePropertiesCurrentUtcOffsetValid

OID (numeric): 1.3.6.1.4.1.4491.2.1.32.1.2.4.1

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-only

Description: This attribute represents the value of currentUtcOffsetValid is TRUE if the currentUtcOffset is known to be correct.

What is docsRphyPtpCcapTimePropertiesCurrentUtcOffsetValid?

This OID is true when the currentUtcOffset value reported elsewhere in this table is known to be accurate. Admins check it before trusting the TAI-UTC offset for time calculations, since a false value means the offset shouldn't be relied on.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4491.2.1.32.1.2.4.1
snmpwalk -v2c -c public <target> DOCS-RPHY-PTP-MIB::docsRphyPtpCcapTimePropertiesCurrentUtcOffsetValid

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.4491.2.1.32.1.2.4.1.1
snmpget -v2c -c public <target> DOCS-RPHY-PTP-MIB::docsRphyPtpCcapTimePropertiesCurrentUtcOffsetValid.1

Start monitoring DOCSIS Remote PHY Device/CCAP Core (IEEE 1588 PTP clock sync, vendor-neutral CableLabs standard) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DOCS-RPHY-PTP-MIB::docsRphyPtpCcapTimePropertiesCurrentUtcOffsetValid OID value, configure state conditions and alerts, and monitor any DOCSIS Remote PHY Device/CCAP Core (IEEE 1588 PTP clock sync, vendor-neutral CableLabs standard) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.4491cableLabsCLAB-DEF-MIB
1.3.6.1.4.1.4491.2clabProjectCLAB-DEF-MIB
1.3.6.1.4.1.4491.2.1clabProjDocsisCLAB-DEF-MIB
Numeric OIDNameModule
1.3.6.1.4.1.4491.2.1.32docsRphyPtpMibDOCS-RPHY-PTP-MIB
1.3.6.1.4.1.4491.2.1.32.1docsRphyPtpObjectsDOCS-RPHY-PTP-MIB
1.3.6.1.4.1.4491.2.1.32.1.2docsRphyPtpCcapMibObjectsDOCS-RPHY-PTP-MIB
1.3.6.1.4.1.4491.2.1.32.1.2.4docsRphyPtpCcapTimePropertiesDOCS-RPHY-PTP-MIB
1.3.6.1.4.1.4491.2.1.32.1.2.4.1docsRphyPtpCcapTimePropertiesCurrentUtcOffsetValidDOCS-RPHY-PTP-MIB