DOCS-RPHY-MIB :: docsRphyRpdIfPhysEntityContainedIn

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › DOCS-RPHY-MIB › docsRphyRpdIfPhysEntityContainedIn

docsRphyRpdIfPhysEntityContainedIn

Module: DOCS-RPHY-MIB

OID (symbolic): DOCS-RPHY-MIB::docsRphyRpdIfPhysEntityContainedIn

OID (numeric): 1.3.6.1.4.1.4491.2.1.30.1.2.1.1.4

Node type: OBJECT-TYPE

Type: PhysicalIndexOrZero

Access: read-only

Description: The value of docsRphyRpdIfPhysEntityIndex for the physical entity that 'contains' this physical entity. A value of zero indicates this physical entity is not contained in any other physical entity. Note that the set of 'containment' relationships define a strict hierarchy; that is, recursion is not allowed.

In the event that a physical entity is contained by more than one physical entity (e.g., double-wide modules), this object should identify the containing entity with the lowest value of docsRphyRpdIfPhysEntityIndex.

What is docsRphyRpdIfPhysEntityContainedIn?

Reports the index of the physical entity that contains this one (e.g., the chassis containing a module), with 0 meaning it is not contained in anything. Management tools walk this chain across the RPD's physical inventory table to reconstruct the containment hierarchy, such as which chassis a given sensor or port physically belongs to.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4491.2.1.30.1.2.1.1.4
snmpwalk -v2c -c public <target> DOCS-RPHY-MIB::docsRphyRpdIfPhysEntityContainedIn

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.4491.2.1.30.1.2.1.1.4.1
snmpget -v2c -c public <target> DOCS-RPHY-MIB::docsRphyRpdIfPhysEntityContainedIn.1

Start monitoring DOCSIS Remote PHY Device (RPD), cable HFC access node (vendor-neutral CableLabs standard) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DOCS-RPHY-MIB::docsRphyRpdIfPhysEntityContainedIn OID value, configure state conditions and alerts, and monitor any DOCSIS Remote PHY Device (RPD), cable HFC access node (vendor-neutral CableLabs standard) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.4491cableLabsCLAB-DEF-MIB
1.3.6.1.4.1.4491.2clabProjectCLAB-DEF-MIB
1.3.6.1.4.1.4491.2.1clabProjDocsisCLAB-DEF-MIB
Numeric OIDNameModule
1.3.6.1.4.1.4491.2.1.30docsRphyMibDOCS-RPHY-MIB
1.3.6.1.4.1.4491.2.1.30.1docsRphyObjectsDOCS-RPHY-MIB
1.3.6.1.4.1.4491.2.1.30.1.2docsRphyRpdIfMibObjectsDOCS-RPHY-MIB
1.3.6.1.4.1.4491.2.1.30.1.2.1docsRphyRpdIfPhysEntityTableDOCS-RPHY-MIB
1.3.6.1.4.1.4491.2.1.30.1.2.1.1docsRphyRpdIfPhysEntityEntryDOCS-RPHY-MIB
1.3.6.1.4.1.4491.2.1.30.1.2.1.1.4docsRphyRpdIfPhysEntityContainedInDOCS-RPHY-MIB