DOCS-RPHY-MIB :: docsRphyRpdDevCapabRpdUcdProcTime

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › DOCS-RPHY-MIB › docsRphyRpdDevCapabRpdUcdProcTime

docsRphyRpdDevCapabRpdUcdProcTime

Module: DOCS-RPHY-MIB

OID (symbolic): DOCS-RPHY-MIB::docsRphyRpdDevCapabRpdUcdProcTime

OID (numeric): 1.3.6.1.4.1.4491.2.1.30.1.1.5.1.29

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-only

Description: This attribute indicates the minimum interval needed by the RPD to process a UCD message received via GCP. This interval is equivalent to CM UCD processing time defined in MULPIv3.1 but its duration can be longer. The maximum value of the RPD UCD Processing time is 50000 usec. The minimum value RPD UCD Processing time is equal to CM UCD processing time (1500 usec for each changed SC-QAM channel or 2000 usec for each changed upstream OFDMA channel) defined in MULPIv3.1.

What is docsRphyRpdDevCapabRpdUcdProcTime?

Reports the minimum time, in the stated units, this RPD needs to process a UCD (Upstream Channel Descriptor) message received via GCP, analogous to cable-modem UCD processing time but potentially longer (up to 50,000 microseconds). The CCAP Core uses this value to schedule sufficient guard time after sending a UCD change before resuming normal upstream scheduling on this RPD.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4491.2.1.30.1.1.5.1.29
snmpwalk -v2c -c public <target> DOCS-RPHY-MIB::docsRphyRpdDevCapabRpdUcdProcTime

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.4491.2.1.30.1.1.5.1.29.1
snmpget -v2c -c public <target> DOCS-RPHY-MIB::docsRphyRpdDevCapabRpdUcdProcTime.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> docsRphyRpdDevCapabRpdUcdProcTime.1

Start monitoring DOCSIS Remote PHY Device (RPD), cable HFC access node (vendor-neutral CableLabs standard) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DOCS-RPHY-MIB::docsRphyRpdDevCapabRpdUcdProcTime OID value, configure state conditions and alerts, and monitor any DOCSIS Remote PHY Device (RPD), cable HFC access node (vendor-neutral CableLabs standard) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.4491cableLabsCLAB-DEF-MIB
1.3.6.1.4.1.4491.2clabProjectCLAB-DEF-MIB
1.3.6.1.4.1.4491.2.1clabProjDocsisCLAB-DEF-MIB
Numeric OIDNameModule
1.3.6.1.4.1.4491.2.1.30docsRphyMibDOCS-RPHY-MIB
1.3.6.1.4.1.4491.2.1.30.1docsRphyObjectsDOCS-RPHY-MIB
1.3.6.1.4.1.4491.2.1.30.1.1docsRphyRpdDevMibObjectsDOCS-RPHY-MIB
1.3.6.1.4.1.4491.2.1.30.1.1.5docsRphyRpdDevCapabilitiesTableDOCS-RPHY-MIB
1.3.6.1.4.1.4491.2.1.30.1.1.5.1docsRphyRpdDevCapabilitiesEntryDOCS-RPHY-MIB
1.3.6.1.4.1.4491.2.1.30.1.1.5.1.29docsRphyRpdDevCapabRpdUcdProcTimeDOCS-RPHY-MIB