All MIBs › DELL-MM-MIB-SMIv2
Category: Domain: Server Hardware, Vendor: Dell
Description: Dell modular management MIB providing chassis and module inventory for Dell modular platforms.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is DELL-MM-MIB-SMIv2?
DELL-MM-MIB-SMIv2 is a Dell enterprise MIB associated with the Management Module (MM) of Dell's modular hardware platforms, such as blade chassis or modular switch/server enclosures. It is intended to expose chassis- and module-level inventory information, letting management tools enumerate the physical components installed in a modular enclosure. In principle a MIB of this kind would be used to monitor hardware presence and status of chassis slots, power supplies, and modules, but no concrete object or table names were available in this extract to confirm specific monitored parameters beyond general inventory. It would typically depend on or complement other Dell chassis-management MIBs for full environmental and power-supply telemetry. It is deployed in data centers running Dell modular blade or chassis-based platforms, where the management module provides centralized inventory and status reporting for the enclosure. Engineers can download the DELL-MM-MIB-SMIv2 file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in DELL-MM-MIB-SMIv2. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Dell modular chassis / blade enclosure management module
Monitoring Examples
No detailed sample objects were available in this extract beyond the module's general inventory purpose, so a concrete polling scenario with specific object names cannot be honestly constructed. Typically an MM MIB of this kind would be polled for chassis and module presence/inventory status.
What Can Be Monitored
- chassis inventory
- installed module inventory
This MIB depends on
Related MIBs
Imported Objects
From SNMPv2-CONF
| NOTIFICATION-GROUP | |
| OBJECT-GROUP |
From SNMPv2-SMI
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-TYPE | |
| enterprises |
From SNMPv2-TC
| DisplayString | |
| TEXTUAL-CONVENTION |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| dell | 1.3.6.1.4.1.674 | |||
| server3 | 1.3.6.1.4.1.674.10892 | |||
| dmmOutOfBandGroup | 1.3.6.1.4.1.674.10892.6 | |||
| dmmInformationGroup | 1.3.6.1.4.1.674.10892.6.1 | |||
| dmmProductInfoGroup | 1.3.6.1.4.1.674.10892.6.1.1 | |||
| STR dmmProductName | 1.3.6.1.4.1.674.10892.6.1.1.1 | DellString | read-only | This attribute defines the product name of a chassis management module. |
| STR dmmProductShortName | 1.3.6.1.4.1.674.10892.6.1.1.2 | DellString | read-only | This attribute defines the short product name of a chassis management module. |
| STR dmmProductDescription | 1.3.6.1.4.1.674.10892.6.1.1.3 | DellString | read-only | This attribute defines the product description of a chassis management module. |
| STR dmmProductManufacturer | 1.3.6.1.4.1.674.10892.6.1.1.4 | DellString | read-only | This attribute defines the product manufacturer of a chassis management module. |
| STR dmmProductVersion | 1.3.6.1.4.1.674.10892.6.1.1.5 | DellString | read-only | This attribute defines the product version of a chassis management module. |
| STR dmmChassisServiceTag | 1.3.6.1.4.1.674.10892.6.1.1.6 | DellString | read-only | This attribute defines the Service Tag of the chassis. |
| STR dmmProductURL | 1.3.6.1.4.1.674.10892.6.1.1.7 | DellString | read-only | This attribute defines the out-of-band UI URL of a chassis management module. |
| STR dmmProductChassisAssetTag | 1.3.6.1.4.1.674.10892.6.1.1.8 | DellString | read-only | This attribute defines the Asset Tag of the chassis. |
| STR dmmProductChassisName | 1.3.6.1.4.1.674.10892.6.1.1.9 | DellString | read-only | This attribute defines the name of the chassis. |
| DEL dmmProductType | 1.3.6.1.4.1.674.10892.6.1.1.10 | DellMmType | read-only | This attribute defines type of a remote management module |
| STR dmmProductChassisDataCenter | 1.3.6.1.4.1.674.10892.6.1.1.11 | DellString | read-only | This attribute defines the Data Center locator of the chassis. |
| STR dmmProductChassisAisle | 1.3.6.1.4.1.674.10892.6.1.1.12 | DellString | read-only | This attribute defines the Aisle locator of the chassis. |
| STR dmmProductChassisRack | 1.3.6.1.4.1.674.10892.6.1.1.13 | DellString | read-only | This attribute defines the Rack locator of the chassis. |
| STR dmmProductChassisRackSlot | 1.3.6.1.4.1.674.10892.6.1.1.14 | DellString | read-only | This attribute defines the Rack Slot locator of the chassis. |
| STR dmmProductChassisModel | 1.3.6.1.4.1.674.10892.6.1.1.15 | DellString | read-only | This attribute defines the Model of the chassis. |
| STR dmmProductChassisExpressServiceCode | 1.3.6.1.4.1.674.10892.6.1.1.16 | DellString | read-only | This attribute defines the Express Service Code of the chassis. |
| INT dmmProductChassisSystemID | 1.3.6.1.4.1.674.10892.6.1.1.17 | INTEGER | read-only | This attribute defines the System ID of the chassis. |
| dmmFirmwareGroup | 1.3.6.1.4.1.674.10892.6.1.2 | |||
| STR dmmFirmwareVersion | 1.3.6.1.4.1.674.10892.6.1.2.1 | DellString | read-only | This attribute defines the firmware version of chassis management module 1. |
| STR dmmFirmwareVersion2 | 1.3.6.1.4.1.674.10892.6.1.2.2 | DellString | read-only | This attribute defines the firmware version of chassis management module 2. |
| dmmStatusGroup | 1.3.6.1.4.1.674.10892.6.2 | |||
| DEL dmmGlobalSystemStatus | 1.3.6.1.4.1.674.10892.6.2.1 | DellStatus | read-only | This attribute defines the overall chassis status being monitored by the chassis management module. |
| dmmChassisStatusGroup | 1.3.6.1.4.1.674.10892.6.3 | |||
| dmmStatusNowGroup | 1.3.6.1.4.1.674.10892.6.3.1 | |||
| DEL dmmIOMCurrStatus | 1.3.6.1.4.1.674.10892.6.3.1.1 | DellStatus | read-only | This attribute defines the IOM subsystem status being monitored by the chassis management module. |
| DEL dmmRedCurrStatus | 1.3.6.1.4.1.674.10892.6.3.1.2 | DellStatus | read-only | This attribute defines the Redundancy status being monitored by the chassis management module. |
| DEL dmmPowerCurrStatus | 1.3.6.1.4.1.674.10892.6.3.1.3 | DellStatus | read-only | This attribute defines the power subsystem health status being monitored by the chassis management module. |
| DEL dmmFanCurrStatus | 1.3.6.1.4.1.674.10892.6.3.1.4 | DellStatus | read-only | This attribute defines the Fan subsystem health status being monitored by the chassis management module. |
| DEL dmmBladeCurrStatus | 1.3.6.1.4.1.674.10892.6.3.1.5 | DellStatus | read-only | This attribute defines the Blade subsystem health status being monitored by the chassis management module. |
| DEL dmmTempCurrStatus | 1.3.6.1.4.1.674.10892.6.3.1.6 | DellStatus | read-only | This attribute defines the Temp Sensor subsystem health status being monitored by the chassis management module. |
| DEL dmmMMCurrStatus | 1.3.6.1.4.1.674.10892.6.3.1.7 | DellStatus | read-only | This attribute defines the health status being monitored by the chassis management module. |
| DEL dmmChassisFrontPanelAmbientTemperature | 1.3.6.1.4.1.674.10892.6.3.1.8 | DellTemperatureReading | read-only | This attribute defines the ambient temperature reading (in degrees Celsius) for the chassis front panel module. |
| dmmChassisPowerGroup | 1.3.6.1.4.1.674.10892.6.4 | |||
| dmmPowerTable | 1.3.6.1.4.1.674.10892.6.4.1 | not-accessible | This object defines the power table. | |
| dmmPowerTableEntry | 1.3.6.1.4.1.674.10892.6.4.1.1 | not-accessible | This object defines the power table entry. | |
| DEL dmmPowerChassisIndex | 1.3.6.1.4.1.674.10892.6.4.1.1.1 | DellPowerIndexRange | read-only | This attribute defines the index (one-based) of the associated chassis. |
| DEL dmmPowerIdlePower | 1.3.6.1.4.1.674.10892.6.4.1.1.2 | DellPowerReading | read-only | This attribute defines the power (in Watts) required by the chassis infrastructure, plus the sum of the minimum power requirements for all currently powered-on servers. |
| DEL dmmPowerKWhCumulative | 1.3.6.1.4.1.674.10892.6.4.1.1.3 | DellPowerReading | read-only | This attribute defines the cumulative chassis power usage (in KWh) since last reset. |
| DEL dmmPowerKWhCumulativeTime | 1.3.6.1.4.1.674.10892.6.4.1.1.4 | DellTimestamp | read-only | This attribute defines the timestamp of the most recent chassis power accumulator reset. |
| DEL dmmPowerWattsPeakUsage | 1.3.6.1.4.1.674.10892.6.4.1.1.5 | DellPowerReading | read-only | This attribute defines the chassis peak power usage (in Watts) since last reset. |
| DEL dmmPowerWattsPeakTime | 1.3.6.1.4.1.674.10892.6.4.1.1.6 | DellTimestamp | read-only | This attribute defines the timestamp of the most recent chassis peak power usage. |
| DEL dmmPowerWattsMinUsage | 1.3.6.1.4.1.674.10892.6.4.1.1.7 | DellPowerReading | read-only | This attribute defines the chassis mimimum power usage (in Watts) since last reset. |
| DEL dmmPowerWattsMinTime | 1.3.6.1.4.1.674.10892.6.4.1.1.8 | DellTimestamp | read-only | This attribute defines the timestamp of the most recent chassis minimum power usage. |
| DEL dmmPowerWattsReading | 1.3.6.1.4.1.674.10892.6.4.1.1.9 | DellPowerReading | read-only | This attribute defines the instantaneous chassis power usage (in Watts). |
| dmmPSUTable | 1.3.6.1.4.1.674.10892.6.4.2 | not-accessible | This object defines the PSU table. | |
| dmmPSUTableEntry | 1.3.6.1.4.1.674.10892.6.4.2.1 | not-accessible | This object defines the PSU table entry. | |
| DEL dmmPSUChassisIndex | 1.3.6.1.4.1.674.10892.6.4.2.1.1 | DellPowerIndexRange | read-only | This attribute defines the index (one-based) of the associated chassis. |
| DEL dmmPSUIndex | 1.3.6.1.4.1.674.10892.6.4.2.1.2 | DellPSUIndexRange | read-only | This attribute defines the index (one-based) of the associated PSU. |
| STR dmmPSULocation | 1.3.6.1.4.1.674.10892.6.4.2.1.3 | DellString | read-only | This attribute defines the location of the PSU. |
| STR dmmPSUState | 1.3.6.1.4.1.674.10892.6.4.2.1.4 | DellString | read-only | This attribute defines the enabled state of of the PSU. |
| STR dmmPSUType | 1.3.6.1.4.1.674.10892.6.4.2.1.5 | DellString | read-only | This attribute defines the type of the PSU. |
| DEL dmmPSUCapacity | 1.3.6.1.4.1.674.10892.6.4.2.1.6 | DellPowerReading | read-only | This attribute defines the capacity in watts of the PSU. |
| DEL dmmPSUVoltage | 1.3.6.1.4.1.674.10892.6.4.2.1.7 | DellPowerReading | read-only | This attribute defines the input voltage of the PSU. |
| DEL dmmPSUCurrStatus | 1.3.6.1.4.1.674.10892.6.4.2.1.8 | DellStatus | read-only | This attribute defines the current status of the PSU. |
| dmmChassisAlert2Group | 1.3.6.1.4.1.674.10892.6.5 | |||
| NTF alert2FanFailure | 1.3.6.1.4.1.674.10892.6.5.0.2153 | Fan failure. | ||
| NTF alert2FanWarning | 1.3.6.1.4.1.674.10892.6.5.0.2154 | Fan warning. | ||
| NTF alert2FanInformation | 1.3.6.1.4.1.674.10892.6.5.0.2155 | Fan information. | ||
| NTF alert2TemperatureProbeFailure | 1.3.6.1.4.1.674.10892.6.5.0.2161 | Temperature sensor has detected a failure value. | ||
| NTF alert2TemperatureProbeWarning | 1.3.6.1.4.1.674.10892.6.5.0.2162 | Temperature sensor has detected a warning value. | ||
| NTF alert2TemperatureProbeNormal | 1.3.6.1.4.1.674.10892.6.5.0.2163 | Temperature sensor value is within range. | ||
| NTF alert2VoltageProbeFailure | 1.3.6.1.4.1.674.10892.6.5.0.2169 | Voltage sensor has detected a failure value. | ||
| NTF alert2VoltageProbeWarning | 1.3.6.1.4.1.674.10892.6.5.0.2170 | Voltage sensor has detected a warning value. | ||
| NTF alert2VoltageProbeNormal | 1.3.6.1.4.1.674.10892.6.5.0.2171 | Voltage sensor reading is within range. | ||
| NTF alert2AmperageProbeFailure | 1.3.6.1.4.1.674.10892.6.5.0.2177 | Current sensor has detected a failure value. | ||
| NTF alert2AmperageProbeWarning | 1.3.6.1.4.1.674.10892.6.5.0.2178 | Current sensor has detected a warning value. | ||
| NTF alert2AmperageProbeNormal | 1.3.6.1.4.1.674.10892.6.5.0.2179 | Current sensor reading is within range. | ||
| NTF alert2PowerSupplyFailure | 1.3.6.1.4.1.674.10892.6.5.0.2185 | Power supply has detected a failure. | ||
| NTF alert2PowerSupplyWarning | 1.3.6.1.4.1.674.10892.6.5.0.2186 | Power supply has detected a warning. | ||
| NTF alert2PowerSupplyNormal | 1.3.6.1.4.1.674.10892.6.5.0.2187 | Power supply has returned to normal. | ||
| NTF alert2BatteryFailure | 1.3.6.1.4.1.674.10892.6.5.0.2225 | Battery has failed or battery is absent. | ||
| NTF alert2BatteryWarning | 1.3.6.1.4.1.674.10892.6.5.0.2226 | Battery is low. | ||
| NTF alert2BatteryNormal | 1.3.6.1.4.1.674.10892.6.5.0.2227 | Battery state has returned to normal; or battery presence had been detected. | ||
| NTF alert2LinkStatusFailure | 1.3.6.1.4.1.674.10892.6.5.0.2249 | Link status failure or critical event. | ||
| NTF alert2LinkStatusWarning | 1.3.6.1.4.1.674.10892.6.5.0.2250 | Link status warning. | ||
| NTF alert2LinkStatusInformation | 1.3.6.1.4.1.674.10892.6.5.0.2251 | Link status information. | ||
| NTF alert2PowerUsageFailure | 1.3.6.1.4.1.674.10892.6.5.0.2273 | Power usage failure. | ||
| NTF alert2PowerUsageWarning | 1.3.6.1.4.1.674.10892.6.5.0.2274 | Power usage warning. | ||
| NTF alert2PowerUsageInformation | 1.3.6.1.4.1.674.10892.6.5.0.2275 | Power usage information. | ||
| NTF alert2HardwareConfigurationFailure | 1.3.6.1.4.1.674.10892.6.5.0.2329 | Hardware configuration failure or critical event. | ||
| NTF alert2HardwareConfigurationWarning | 1.3.6.1.4.1.674.10892.6.5.0.2330 | Hardware configuration warning. | ||
| NTF alert2HardwareConfigurationInformation | 1.3.6.1.4.1.674.10892.6.5.0.2331 | Hardware configuration information. | ||
| NTF alert2SoftwareConfigurationFailure | 1.3.6.1.4.1.674.10892.6.5.0.2337 | Software configuration failure. | ||
| NTF alert2SoftwareConfigurationWarning | 1.3.6.1.4.1.674.10892.6.5.0.2338 | Software configuration warning. | ||
| NTF alert2SoftwareConfigurationInformation | 1.3.6.1.4.1.674.10892.6.5.0.2339 | Software configuration information. | ||
| NTF alert2SystemEventLogFailure | 1.3.6.1.4.1.674.10892.6.5.0.2377 | System Event Log failure or critical event. | ||
| NTF alert2SystemEventLogWarning | 1.3.6.1.4.1.674.10892.6.5.0.2378 | System Event Log warning. | ||
| NTF alert2SystemEventLogInformation | 1.3.6.1.4.1.674.10892.6.5.0.2379 | System Event Log information. | ||
| NTF alert2SecurityFailure | 1.3.6.1.4.1.674.10892.6.5.0.2385 | Security failure or critical event. | ||
| NTF alert2SecurityWarning | 1.3.6.1.4.1.674.10892.6.5.0.2386 | Security warning. | ||
| NTF alert2SecurityInformation | 1.3.6.1.4.1.674.10892.6.5.0.2387 | Security information. | ||
| NTF alert2CableFailure | 1.3.6.1.4.1.674.10892.6.5.0.2393 | Cable failure. | ||
| NTF alert2PowerSupplyAbsent | 1.3.6.1.4.1.674.10892.6.5.0.2465 | Power supply is absent. | ||
| NTF alert2RedundancyLost | 1.3.6.1.4.1.674.10892.6.5.0.2473 | Redundancy is lost. | ||
| NTF alert2RedundancyDegraded | 1.3.6.1.4.1.674.10892.6.5.0.2474 | Redundancy is degraded. | ||
| NTF alert2RedundancyInformation | 1.3.6.1.4.1.674.10892.6.5.0.2475 | Redundancy information. | ||
| NTF alert2CMCFailure | 1.3.6.1.4.1.674.10892.6.5.0.2545 | Chassis Management Module detected an error. | ||
| NTF alert2CMCWarning | 1.3.6.1.4.1.674.10892.6.5.0.2546 | Chassis Management Module detected a warning. | ||
| NTF alert2IOVirtualizationFailure | 1.3.6.1.4.1.674.10892.6.5.0.2553 | IO Virtualization failure or critical event. | ||
| NTF alert2IOVirtualizationWarning | 1.3.6.1.4.1.674.10892.6.5.0.2554 | IO Virtualization warning. | ||
| NTF alert2IOVirtualizationInformation | 1.3.6.1.4.1.674.10892.6.5.0.2555 | IO Virtualization information. | ||
| NTF alert2StorageManagementFailure | 1.3.6.1.4.1.674.10892.6.5.0.4177 | Storage Management has detected a device independent error condition. There is no global status change associated with this trap. | ||
| NTF alert2StorageManagementWarning | 1.3.6.1.4.1.674.10892.6.5.0.4178 | Storage Management has detected a device independent warning condition. There is no global status change associated with this trap. | ||
| NTF alert2StorageManagementInformation | 1.3.6.1.4.1.674.10892.6.5.0.4179 | Storage Management information. There is no global status change associated with this trap. | ||
| NTF alert2StorageFanFailure | 1.3.6.1.4.1.674.10892.6.5.0.4201 | Storage Fan failure. | ||
| NTF alert2StorageFanWarning | 1.3.6.1.4.1.674.10892.6.5.0.4202 | Storage Fan warning. | ||
| NTF alert2StorageFanInformation | 1.3.6.1.4.1.674.10892.6.5.0.4203 | Storage Fan information. | ||
| NTF alert2StorageTemperatureProbeFailure | 1.3.6.1.4.1.674.10892.6.5.0.4209 | Storage Temperature probe failure. | ||
| NTF alert2StorageTemperatureProbeWarning | 1.3.6.1.4.1.674.10892.6.5.0.4210 | Storage Temperature probe warning. | ||
| NTF alert2StorageTemperatureProbeInformation | 1.3.6.1.4.1.674.10892.6.5.0.4211 | Storage Temperature probe information. | ||
| NTF alert2StoragePowerSupplyFailure | 1.3.6.1.4.1.674.10892.6.5.0.4233 | Storage Power supply failure. | ||
| NTF alert2StoragePowerSupplyWarning | 1.3.6.1.4.1.674.10892.6.5.0.4234 | Storage Power supply warning. | ||
| NTF alert2StoragePowerSupplyInformation | 1.3.6.1.4.1.674.10892.6.5.0.4235 | Storage Power supply information. | ||
| NTF alert2StorageBatteryFailure | 1.3.6.1.4.1.674.10892.6.5.0.4273 | Storage Battery failure. | ||
| NTF alert2StorageBatteryWarning | 1.3.6.1.4.1.674.10892.6.5.0.4274 | Storage Battery warning. | ||
| NTF alert2StorageBatteryInformation | 1.3.6.1.4.1.674.10892.6.5.0.4275 | Storage Battery information. | ||
| NTF alert2StorageControllerFailure | 1.3.6.1.4.1.674.10892.6.5.0.4329 | Storage Controller failure. | ||
| NTF alert2StorageControllerWarning | 1.3.6.1.4.1.674.10892.6.5.0.4330 | Storage Controller warning. | ||
| NTF alert2StorageControllerInformation | 1.3.6.1.4.1.674.10892.6.5.0.4331 | Storage Controller information. | ||
| NTF alert2StorageEnclosureFailure | 1.3.6.1.4.1.674.10892.6.5.0.4337 | Storage Enclosure failure. | ||
| NTF alert2StorageEnclosureWarning | 1.3.6.1.4.1.674.10892.6.5.0.4338 | Storage Enclosure warning. | ||
| NTF alert2StorageEnclosureInformation | 1.3.6.1.4.1.674.10892.6.5.0.4339 | Storage Enclosure information. | ||
| NTF alert2StoragePhysicalDiskFailure | 1.3.6.1.4.1.674.10892.6.5.0.4345 | Storage Physical disk failure. | ||
| NTF alert2StoragePhysicalDiskWarning | 1.3.6.1.4.1.674.10892.6.5.0.4346 | Storage Physical disk warning. | ||
| NTF alert2StoragePhysicalDiskInformation | 1.3.6.1.4.1.674.10892.6.5.0.4347 | Storage Physical disk information. | ||
| NTF alert2StorageVirtualDiskFailure | 1.3.6.1.4.1.674.10892.6.5.0.4353 | Storage Virtual disk failure. | ||
| NTF alert2StorageVirtualDiskWarning | 1.3.6.1.4.1.674.10892.6.5.0.4354 | Storage Virtual disk warning. | ||
| NTF alert2StorageVirtualDiskInformation | 1.3.6.1.4.1.674.10892.6.5.0.4355 | Storage Virtual disk information. | ||
| NTF alert2StorageSecurityFailure | 1.3.6.1.4.1.674.10892.6.5.0.4433 | Storage Security failure or critical event. | ||
| NTF alert2StorageSecurityWarning | 1.3.6.1.4.1.674.10892.6.5.0.4434 | Storage Security warning. | ||
| NTF alert2StorageSecurityInformation | 1.3.6.1.4.1.674.10892.6.5.0.4435 | Storage Security information. | ||
| NTF alert2SoftwareChangeUpdateWarning | 1.3.6.1.4.1.674.10892.6.5.0.6314 | Software change update warning. | ||
| NTF alert2PowerSupplyAuditFailure | 1.3.6.1.4.1.674.10892.6.5.0.8329 | Power Supply audit failure or critical event. | ||
| NTF alert2PowerSupplyAuditWarning | 1.3.6.1.4.1.674.10892.6.5.0.8330 | Power Supply audit warning. | ||
| NTF alert2SoftwareChangeAuditFailure | 1.3.6.1.4.1.674.10892.6.5.0.8361 | Software change audit failure or critical event. | ||
| NTF alert2PowerUsageAuditFailure | 1.3.6.1.4.1.674.10892.6.5.0.8417 | Power usage audit failure or critical event. | ||
| NTF alert2PowerUsageAuditWarning | 1.3.6.1.4.1.674.10892.6.5.0.8418 | Power usage audit warning. | ||
| NTF alert2PowerUsageAuditInformation | 1.3.6.1.4.1.674.10892.6.5.0.8419 | Power usage audit information. | ||
| NTF alert2LicenseFailure | 1.3.6.1.4.1.674.10892.6.5.0.8513 | License failure. | ||
| NTF alert2LicenseWarning | 1.3.6.1.4.1.674.10892.6.5.0.8514 | License warning. | ||
| NTF alert2LicenseInformation | 1.3.6.1.4.1.674.10892.6.5.0.8515 | License information. | ||
| NTF alert2PCIDeviceAuditWarning | 1.3.6.1.4.1.674.10892.6.5.0.8562 | PCI device audit warning. | ||
| NTF alert2CMCAuditFailure | 1.3.6.1.4.1.674.10892.6.5.0.8689 | Chassis Management Module audit failure or critical event. | ||
| NTF alert2CMCAuditWarning | 1.3.6.1.4.1.674.10892.6.5.0.8690 | Chassis Management Module audit warning. | ||
| NTF alert2CMCAuditInformation | 1.3.6.1.4.1.674.10892.6.5.0.8691 | Chassis Management Module audit information. | ||
| NTF alert2IOVirtualizationAuditWarning | 1.3.6.1.4.1.674.10892.6.5.0.8698 | IO Virtualization audit warning. | ||
| NTF alert2CMCTestTrap | 1.3.6.1.4.1.674.10892.6.5.0.10395 | Test trap generated in response to a user request. | ||
| NTF alert2SWCConfigurationFailure | 1.3.6.1.4.1.674.10892.6.5.0.10529 | Software configuration failure. | ||
| NTF alert2SWCConfigurationWarning | 1.3.6.1.4.1.674.10892.6.5.0.10530 | Software configuration warning. | ||
| NTF alert2PCIDeviceConfigurationInformation | 1.3.6.1.4.1.674.10892.6.5.0.10611 | PCI device configuration information. | ||
| NTF alert2IOVConfigurationWarning | 1.3.6.1.4.1.674.10892.6.5.0.10746 | IO Virtualization configuration warning. | ||
| NTF alert2IOVConfigurationInformation | 1.3.6.1.4.1.674.10892.6.5.0.10747 | IO Virtualization configuration information. | ||
| dmmChassisAlert2Variables | 1.3.6.1.4.1.674.10892.6.5.1 | |||
| STR dmmCA2MessageID | 1.3.6.1.4.1.674.10892.6.5.1.1 | DisplayString | read-only | Message ID of the alert. |
| STR dmmCA2Message | 1.3.6.1.4.1.674.10892.6.5.1.2 | DellString | read-only | Message describing the alert. |
| STR dmmCA2MessageArgs | 1.3.6.1.4.1.674.10892.6.5.1.3 | DellString | read-only | Concatenated set of strings representing any message arguments that were used to construct the alert message. Each message argument string is enclosed in double quotes, and there is a comma after the ending double quote of each message argument string, except the last one. Any double quotes found within a message argument string were preprocessed and changed to single quotes. |
| DEL dmmCA2AlertStatus | 1.3.6.1.4.1.674.10892.6.5.1.4 | DellStatus | read-only | Status of the alert. |
| STR dmmCA2FQDD | 1.3.6.1.4.1.674.10892.6.5.1.5 | DisplayString | read-only | Fully qualified device descriptor of device causing the alert. |
| dmmGenericAlertGroup | 1.3.6.1.4.1.674.10892.6.6 | |||
| NTF alertGenericCritical | 1.3.6.1.4.1.674.10892.6.6.0.100 | MM generic critical system alert. | ||
| NTF alertGenericWarning | 1.3.6.1.4.1.674.10892.6.6.0.200 | MM generic warning system alert. | ||
| NTF alertGenericNormal | 1.3.6.1.4.1.674.10892.6.6.0.300 | MM generic normal system alert. | ||
| NTF alertGenericInformational | 1.3.6.1.4.1.674.10892.6.6.0.400 | MM generic information system alert. | ||
| NTF alertGenericTestTrapEvent | 1.3.6.1.4.1.674.10892.6.6.0.500 | MM Generated a test trap event in response to a user request. | ||
| dmmGenericAlertVariables | 1.3.6.1.4.1.674.10892.6.6.1 | |||
| STR dmmDeviceServiceTag | 1.3.6.1.4.1.674.10892.6.6.1.1 | DellString | read-only | Service tag of the device. |
| conformanceGroup | 1.3.6.1.4.1.674.10892.6.7 | |||
| conformanceMIBGroups | 1.3.6.1.4.1.674.10892.6.7.1 | |||
| dmmProductInfoObjGroup | 1.3.6.1.4.1.674.10892.6.7.1.1 | A collection of objects providing information about the chassis management module. | ||
| dmmFirmwareObjGroup | 1.3.6.1.4.1.674.10892.6.7.1.2 | A collection of objects providing information about the chassis firmware version. | ||
| dmmStatusObjGroup | 1.3.6.1.4.1.674.10892.6.7.1.3 | Object is providing information about the overall chassis status. | ||
| dmmStatusNowObjGroup | 1.3.6.1.4.1.674.10892.6.7.1.4 | A collection of objects providing information about the chassis subsystem status. | ||
| dmmChassisPowerObjGroup | 1.3.6.1.4.1.674.10892.6.7.1.5 | A collection of objects providing information about the chassis Power. | ||
| dmmPowerTableObjEntry | 1.3.6.1.4.1.674.10892.6.7.1.6 | A collection of objects providing information about the chassis Power Information. | ||
| dmmPSUTableObjEntry | 1.3.6.1.4.1.674.10892.6.7.1.7 | A collection of objects providing information about the chassis Power Supply. | ||
| dmmChassisAlert2VariablesObj | 1.3.6.1.4.1.674.10892.6.7.1.8 | A collection of objects providing information about the chassis Alerts. | ||
| dmmGenericAlertVariablesObj | 1.3.6.1.4.1.674.10892.6.7.1.9 | A collection of objects providing information about the chassis Alerts. | ||
| conformanceMIBnotificationGroup | 1.3.6.1.4.1.674.10892.6.7.2 | |||
| dmmChassisAlert2NotificationGroup | 1.3.6.1.4.1.674.10892.6.7.2.1 | The two notifications which an SNMPv2 entity is required to implement. | ||
| dmmGenericAlertNotificationGroup | 1.3.6.1.4.1.674.10892.6.7.2.2 | The two notifications which an SNMPv2 entity is required to implement. |
RFC description
Manages Dell Management Module (MM) in modular chassis systems, providing monitoring for power supplies, status, and physical components.
Start monitoring Dell modular chassis/blade enclosure management module with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.