CPQHSV400V11-MIB :: sCellEventTrap_0c_7e

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CPQHSV400V11-MIB › sCellEventTrap_0c_7e

sCellEventTrap_0c_7e

Module: CPQHSV400V11-MIB

OID (symbolic): CPQHSV400V11-MIB::sCellEventTrap_0c_7e

OID (numeric): 1.3.6.1.4.1.232.0.13603198

Node type: NOTIFICATION-TYPE

Description: Severity: Critical -- failure or failure imminent. The Data Replication Path between this Storage System and the Peer Storage System has closed because the connection has been logged out.

Examples

Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):

snmptrap -v2c -c public <manager> '' CPQHSV400V11-MIB::sCellEventTrap_0c_7e
snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.232.0.13603198

Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):

snmptrapd -f -Lo -c /dev/null authCommunity log public

Example snmptrapd log entry:

zoo11-linux.zoo [UDP: [192.168.30.111]:56380->[192.168.30.10]:162]:
  DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (141275708) 16 days, 8:25:57.08
  SNMPv2-MIB::snmpTrapOID.0 = OID: CPQHSV400V11-MIB::sCellEventTrap_0c_7e

Start monitoring Compaq/HP StorageWorks HSV400 SAN array controller with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQHSV400V11-MIB::sCellEventTrap_0c_7e OID value, configure state conditions and alerts, and monitor any Compaq/HP StorageWorks HSV400 SAN array controller from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.232compaqCOMPAQ-ID-REC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.232.0.13603198sCellEventTrap_0c_7eCPQHSV400V11-MIB