CPQHSV110V3-MIB :: sCellEventTrap6D

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CPQHSV110V3-MIB › sCellEventTrap6D

sCellEventTrap6D

Module: CPQHSV110V3-MIB

OID (symbolic): CPQHSV110V3-MIB::sCellEventTrap6D

OID (numeric): 1.3.6.1.4.1.232.0.13601549

Node type: NOTIFICATION-TYPE

Description: Severity: Normal -- informational in nature. The location of a physical disk drive previously reported as unknown is now known. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerpId field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the alPa field. The missingPort and missingCerpId fields are unused. The location of the physical disk drive is contained in the rackNum, denclNum, and bay fields. Note that the content of the rackNum field will not be valid until a future release. Note also that in this case the content of fedClass, alPa and numTimes fields are undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerpId field. The location of an available drive enclosure is determined by the content of the enclosures.denclNum field as follows:

  • If enclosures.denclNum is less than 99, the location is as indicated by the content of the enclosures.rackNum and enclosures.denclNum fields.
  • If enclosures.denclNum is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rackNum field is undefined in this case.
  • If enclosures.denclNum is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rackNum and enclosures.denclNum fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate.
Note that the content of the enclosures.rackNum field will not be valid until a future release.

Examples

Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):

snmptrap -v2c -c public <manager> '' CPQHSV110V3-MIB::sCellEventTrap6D
snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.232.0.13601549

Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):

snmptrapd -f -Lo -c /dev/null authCommunity log public

Example snmptrapd log entry:

zoo11-linux.zoo [UDP: [192.168.30.111]:62128->[192.168.30.10]:162]:
  DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (229364400) 26 days, 13:07:24.00
  SNMPv2-MIB::snmpTrapOID.0 = OID: CPQHSV110V3-MIB::sCellEventTrap6D

SNMPv3 example:

snmptrap -v3 -l authPriv -u snmpv3user -a SHA -A "AuthPass1" -x AES -X "PrivPass1" <manager> '' CPQHSV110V3-MIB::sCellEventTrap6D

Start monitoring HP StorageWorks HSV110 (EVA) array controller with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQHSV110V3-MIB::sCellEventTrap6D OID value, configure state conditions and alerts, and monitor any HP StorageWorks HSV110 (EVA) array controller from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.232compaqCOMPAQ-ID-REC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.232.0.13601549sCellEventTrap6DCPQHSV110V3-MIB