CM-PERFORMANCE-MIB :: ocnStmStatsLineFarEndESs

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCM-PERFORMANCE-MIBocnStmStatsLineFarEndESs

ocnStmStatsLineFarEndESs

Module: CM-PERFORMANCE-MIB

OID (symbolic): CM-PERFORMANCE-MIB::ocnStmStatsLineFarEndESs

OID (numeric): 1.3.6.1.4.1.2544.1.12.5.1.46.1.15

Node type: OBJECT-TYPE

Type: PerfCounter64

Access: read-only

Description: The counter associated with the number of Far End Errored Seconds encountered by a SONET/SDH Section in the current bin.

What is ocnStmStatsLineFarEndESs?

This read-only PerfCounter64 counts Far End Errored Seconds encountered by the SONET/SDH transport in the current bin, per its own description, reflecting error seconds reported back from the remote end of the link. It lets an administrator distinguish a problem on the remote side of the circuit from one on the local receive path, since far-end and near-end error counters can diverge. For example, high ocnStmStatsLineFarEndESs alongside a clean local ocnStmStatsLineESs would point troubleshooting toward the remote site's transmitter or its local fiber plant.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.5.1.46.1.15
snmpwalk -v2c -c public <target> CM-PERFORMANCE-MIB::ocnStmStatsLineFarEndESs

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.5.1.46.1.15.1
snmpget -v2c -c public <target> CM-PERFORMANCE-MIB::ocnStmStatsLineFarEndESs.1

Start monitoring ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CM-PERFORMANCE-MIB::ocnStmStatsLineFarEndESs OID value, configure state conditions and alerts, and monitor any ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.12fsp150cmADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.12.5cmPerformanceMIBCM-PERFORMANCE-MIB
1.3.6.1.4.1.2544.1.12.5.1cmPerfObjectsCM-PERFORMANCE-MIB
1.3.6.1.4.1.2544.1.12.5.1.46ocnStmStatsTableCM-PERFORMANCE-MIB
1.3.6.1.4.1.2544.1.12.5.1.46.1ocnStmStatsEntryCM-PERFORMANCE-MIB
1.3.6.1.4.1.2544.1.12.5.1.46.1.15ocnStmStatsLineFarEndESsCM-PERFORMANCE-MIB