All MIBs › CM-PERFORMANCE-MIB › ocnStmHistoryLineOPT
ocnStmHistoryLineOPT
Module: CM-PERFORMANCE-MIB
OID (symbolic): CM-PERFORMANCE-MIB::ocnStmHistoryLineOPT
OID (numeric): 1.3.6.1.4.1.2544.1.12.5.1.47.1.6
Node type: OBJECT-TYPE
Type: Integer32
Access: read-only
Description:
Transmit Optical Power retrieved from the SFP.
What is ocnStmHistoryLineOPT?
This integer value represents the transmit optical power reading (in typically dBm units) that was measured and retrieved from the SFP transceiver during a performance monitoring interval. It records historical optical power data for trend analysis. Operators track this metric to monitor transceiver aging, detect optical power degradation, and plan maintenance.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.5.1.47.1.6 snmpwalk -v2c -c public <target> CM-PERFORMANCE-MIB::ocnStmHistoryLineOPT
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.5.1.47.1.6.1 snmpget -v2c -c public <target> CM-PERFORMANCE-MIB::ocnStmHistoryLineOPT.1
OID Breakdown
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | BIANCA-BRICK-PPP-MIB |
| 1.3.6 | dod | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1 | internet | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1.4 | private | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1.4.1 | enterprises | ANIROOT-MIB |
| 1.3.6.1.4.1.2544 | advaMIB | ADVA-MIB |
| 1.3.6.1.4.1.2544.1 | products | ADVA-MIB |
| 1.3.6.1.4.1.2544.1.12 | fsp150cm | ADVA-MIB |
| 1.3.6.1.4.1.2544.1.12.5 | cmPerformanceMIB | CM-PERFORMANCE-MIB |
| 1.3.6.1.4.1.2544.1.12.5.1 | cmPerfObjects | CM-PERFORMANCE-MIB |
| 1.3.6.1.4.1.2544.1.12.5.1.47 | ocnStmHistoryTable | CM-PERFORMANCE-MIB |
| 1.3.6.1.4.1.2544.1.12.5.1.47.1 | ocnStmHistoryEntry | CM-PERFORMANCE-MIB |
| 1.3.6.1.4.1.2544.1.12.5.1.47.1.6 | ocnStmHistoryLineOPT | CM-PERFORMANCE-MIB |