CM-PERFORMANCE-MIB :: cmFlowPointStatsFBCD

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCM-PERFORMANCE-MIBcmFlowPointStatsFBCD

cmFlowPointStatsFBCD

Module: CM-PERFORMANCE-MIB

OID (symbolic): CM-PERFORMANCE-MIB::cmFlowPointStatsFBCD

OID (numeric): 1.3.6.1.4.1.2544.1.12.5.1.25.1.22

Node type: OBJECT-TYPE

Type: PerfCounter64

Access: read-only

Description: The number of Frame with Destination MAC BroadCast dropped in ingress FP.

What is cmFlowPointStatsFBCD?

This OID counts how many network frames with broadcast destination addresses were discarded at the ingress flow point. A high count indicates the device is filtering or dropping broadcast traffic that may not be needed downstream. An operator checks this metric to verify that broadcast suppression policies are working and to estimate bandwidth saved.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.5.1.25.1.22
snmpwalk -v2c -c public <target> CM-PERFORMANCE-MIB::cmFlowPointStatsFBCD

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.5.1.25.1.22.1
snmpget -v2c -c public <target> CM-PERFORMANCE-MIB::cmFlowPointStatsFBCD.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> cmFlowPointStatsFBCD.1

Start monitoring ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CM-PERFORMANCE-MIB::cmFlowPointStatsFBCD OID value, configure state conditions and alerts, and monitor any ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.12fsp150cmADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.12.5cmPerformanceMIBCM-PERFORMANCE-MIB
1.3.6.1.4.1.2544.1.12.5.1cmPerfObjectsCM-PERFORMANCE-MIB
1.3.6.1.4.1.2544.1.12.5.1.25cmFlowPointStatsTableCM-PERFORMANCE-MIB
1.3.6.1.4.1.2544.1.12.5.1.25.1cmFlowPointStatsEntryCM-PERFORMANCE-MIB
1.3.6.1.4.1.2544.1.12.5.1.25.1.22cmFlowPointStatsFBCDCM-PERFORMANCE-MIB