CM-PERFORMANCE-MIB :: cmFlowPointHistoryFBCD

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCM-PERFORMANCE-MIBcmFlowPointHistoryFBCD

cmFlowPointHistoryFBCD

Module: CM-PERFORMANCE-MIB

OID (symbolic): CM-PERFORMANCE-MIB::cmFlowPointHistoryFBCD

OID (numeric): 1.3.6.1.4.1.2544.1.12.5.1.26.1.22

Node type: OBJECT-TYPE

Type: PerfCounter64

Access: read-only

Description: The number of Frame with Destination MAC BroadCast dropped in ingress FP.

What is cmFlowPointHistoryFBCD?

This read-only PerfCounter64 counts frames addressed to the broadcast MAC that were dropped on ingress at this flow point during the history bin. It helps an administrator spot broadcast storms or overly aggressive broadcast rate-limiting on the ingress side of the flow point, since legitimate ARP or DHCP broadcasts should rarely be dropped in normal operation. For instance, if end users on a VLAN report intermittent ARP failures, comparing spikes in cmFlowPointHistoryFBCD against the time of the complaint can confirm broadcast frames were being discarded rather than lost elsewhere.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.5.1.26.1.22
snmpwalk -v2c -c public <target> CM-PERFORMANCE-MIB::cmFlowPointHistoryFBCD

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.5.1.26.1.22.1
snmpget -v2c -c public <target> CM-PERFORMANCE-MIB::cmFlowPointHistoryFBCD.1

Start monitoring ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CM-PERFORMANCE-MIB::cmFlowPointHistoryFBCD OID value, configure state conditions and alerts, and monitor any ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.12fsp150cmADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.12.5cmPerformanceMIBCM-PERFORMANCE-MIB
1.3.6.1.4.1.2544.1.12.5.1cmPerfObjectsCM-PERFORMANCE-MIB
1.3.6.1.4.1.2544.1.12.5.1.26cmFlowPointHistoryTableCM-PERFORMANCE-MIB
1.3.6.1.4.1.2544.1.12.5.1.26.1cmFlowPointHistoryEntryCM-PERFORMANCE-MIB
1.3.6.1.4.1.2544.1.12.5.1.26.1.22cmFlowPointHistoryFBCDCM-PERFORMANCE-MIB