OID (symbolic): CM-PERFORMANCE-MIB::cmEthernetAccPortStatsTemp
OID (numeric): 1.3.6.1.4.1.2544.1.12.5.1.1.1.39
Node type: OBJECT-TYPE
Type: Integer32
Access: read-only
Description: The temperature of the physical layer when media type is fiber.
What is cmEthernetAccPortStatsTemp?
This read-only value reports the physical-layer temperature of the access port, applicable when the port's media type is fiber, per the description. Admins monitor this to catch a fiber transceiver running hot, which is often an early indicator of impending optical module failure. For example, if this temperature reading climbs well above the module's normal operating range, an admin would schedule replacement of that transceiver before it fails outright.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.5.1.1.1.39 snmpwalk -v2c -c public <target> CM-PERFORMANCE-MIB::cmEthernetAccPortStatsTemp
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.5.1.1.1.39.1 snmpget -v2c -c public <target> CM-PERFORMANCE-MIB::cmEthernetAccPortStatsTemp.1
Start monitoring ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CM-PERFORMANCE-MIB::cmEthernetAccPortStatsTemp OID value, configure state conditions and alerts, and monitor any ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform from a single console.
How to Use in IPNetwork Monitor
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.2544 | advaMIB | ADVA-MIB |
| 1.3.6.1.4.1.2544.1 | products | ADVA-MIB |
| 1.3.6.1.4.1.2544.1.12 | fsp150cm | ADVA-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2544.1.12.5 | cmPerformanceMIB | CM-PERFORMANCE-MIB |
| 1.3.6.1.4.1.2544.1.12.5.1 | cmPerfObjects | CM-PERFORMANCE-MIB |
| 1.3.6.1.4.1.2544.1.12.5.1.1 | cmEthernetAccPortStatsTable | CM-PERFORMANCE-MIB |
| 1.3.6.1.4.1.2544.1.12.5.1.1.1 | cmEthernetAccPortStatsEntry | CM-PERFORMANCE-MIB |
| 1.3.6.1.4.1.2544.1.12.5.1.1.1.39 | cmEthernetAccPortStatsTemp | CM-PERFORMANCE-MIB |