CISCO-ITP-GSCCP-MIB :: cgsccpInstTotalMsgs

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-ITP-GSCCP-MIBcgsccpInstTotalMsgs

cgsccpInstTotalMsgs

Module: CISCO-ITP-GSCCP-MIB

OID (symbolic): CISCO-ITP-GSCCP-MIB::cgsccpInstTotalMsgs

OID (numeric): 1.3.6.1.4.1.9.9.335.1.2.1.1.1

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: This counter is incremented every time a message is handled from a local or remote subsystem(Q752/9.3).

What is cgsccpInstTotalMsgs?

This read-only counter tracks the total number of messages handled to or from any local or remote subsystem, per Q.752/9.3.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.335.1.2.1.1.1
snmpwalk -v2c -c public <target> CISCO-ITP-GSCCP-MIB::cgsccpInstTotalMsgs

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.335.1.2.1.1.1.1
snmpget -v2c -c public <target> CISCO-ITP-GSCCP-MIB::cgsccpInstTotalMsgs.1

Start monitoring Cisco IP Transfer Point (ITP) SS7 signaling gateway (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-ITP-GSCCP-MIB::cgsccpInstTotalMsgs OID value, configure state conditions and alerts, and monitor any Cisco IP Transfer Point (ITP) SS7 signaling gateway (legacy) from a single console.

How to Use in IPNetwork Monitor

Select a Cisco IP Transfer Point (ITP) SS7 signaling gateway (legacy) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type cgsccpInstTotalMsgs into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. This counter is incremented every time a message is handled from a local or remote subsystem(Q752/9.3). On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline (in packets), since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9.9.335ciscoGsccpMIBCISCO-ITP-GSCCP-MIB
1.3.6.1.4.1.9.9.335.1ciscoGsccpMIBObjectsCISCO-ITP-GSCCP-MIB
1.3.6.1.4.1.9.9.335.1.2cgsccpInstCISCO-ITP-GSCCP-MIB
1.3.6.1.4.1.9.9.335.1.2.1cgsccpInstTableCISCO-ITP-GSCCP-MIB
1.3.6.1.4.1.9.9.335.1.2.1.1cgsccpInstTableEntryCISCO-ITP-GSCCP-MIB
1.3.6.1.4.1.9.9.335.1.2.1.1.1cgsccpInstTotalMsgsCISCO-ITP-GSCCP-MIB