CISCO-GSLB-HEALTH-MON-MIB :: cghMonKalSentProbes

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-GSLB-HEALTH-MON-MIBcghMonKalSentProbes

cghMonKalSentProbes

Module: CISCO-GSLB-HEALTH-MON-MIB

OID (symbolic): CISCO-GSLB-HEALTH-MON-MIB::cghMonKalSentProbes

OID (numeric): 1.3.6.1.4.1.9.9.600.1.4.3.1.2

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: This object specifies the total number of keepalive probes sent to the remote device, identified by cgdAnswerAddress. This value of this object is sum of cghMonKalPositiveProbes & cghMonKalNegativeProbes

What is cghMonKalSentProbes?

Counts the total keepalive probes sent to a remote answer device, equal to the sum of positive and negative probe counts.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.600.1.4.3.1.2
snmpwalk -v2c -c public <target> CISCO-GSLB-HEALTH-MON-MIB::cghMonKalSentProbes

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.600.1.4.3.1.2.1
snmpget -v2c -c public <target> CISCO-GSLB-HEALTH-MON-MIB::cghMonKalSentProbes.1

Start monitoring Cisco Global Site Selector (GSS) / GSLB devices with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-GSLB-HEALTH-MON-MIB::cghMonKalSentProbes OID value, configure state conditions and alerts, and monitor any Cisco Global Site Selector (GSS) / GSLB devices from a single console.

How to Use in IPNetwork Monitor

Select a Cisco Global Site Selector (GSS) / GSLB device as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type cghMonKalSentProbes into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. This object specifies the total number of keepalive probes sent to the remote device, identified by cgdAnswerAddress. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline (in probes), since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9.9.600ciscoGslbHealthMonMIBCISCO-GSLB-HEALTH-MON-MIB
1.3.6.1.4.1.9.9.600.1ciscoGslbHealthMonMIBObjectsCISCO-GSLB-HEALTH-MON-MIB
1.3.6.1.4.1.9.9.600.1.4cghMonKalCISCO-GSLB-HEALTH-MON-MIB
1.3.6.1.4.1.9.9.600.1.4.3cghMonKalStatsTableCISCO-GSLB-HEALTH-MON-MIB
1.3.6.1.4.1.9.9.600.1.4.3.1cghMonKalStatsEntryCISCO-GSLB-HEALTH-MON-MIB
1.3.6.1.4.1.9.9.600.1.4.3.1.2cghMonKalSentProbesCISCO-GSLB-HEALTH-MON-MIB