CIENA-CES-MODULE-MIB :: cienaCesModuleProtectionModeHotNotification

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCIENA-CES-MODULE-MIBcienaCesModuleProtectionModeHotNotification

cienaCesModuleProtectionModeHotNotification

Module: CIENA-CES-MODULE-MIB

OID (symbolic): CIENA-CES-MODULE-MIB::cienaCesModuleProtectionModeHotNotification

OID (numeric): 1.3.6.1.4.1.1271.2.2.3.0.14

Node type: NOTIFICATION-TYPE

Description: This notification is sent when the protection mode of the system changes to hot. A HOT protection level is the highest level of protection. It implies that the secondary CTM is ready to assume the function of the primary CTM and a failure causing a failover would NOT be service impacting. The secondary CTM has been synchronized with the same software package, configuration files, etc such that it will return the same state as the previous primary CTM. The protection state of the primary CTM shall not transition from NONE to PROTECTED until the secondary CTM has completed the synchronization. In the case of a failure on the primary CTM, the secondary CTM will immediately assume primary status, finish its initialization and audit the PSLMs. All current established traffic patterns will be maintained with a minimal loss of traffic. Any unsaved configuration changes will NOT be lost on a failover as configuration changes are propagated to the secondary CTM configuration. To enable the device to send this notification: - cienaCesModuleAllModulesTrapState needs to be set to enabled. - cienaCesModuleProtectionModeTrapState needs to be set to enabled. The above values are set to enabled by default. Variable bindings include: cienaGlobalSeverity, cienaGlobalMacAddress, and cienaCesModuleSystemProtectionMode.

Examples

Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):

snmptrap -v2c -c public <manager> '' CIENA-CES-MODULE-MIB::cienaCesModuleProtectionModeHotNotification
snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.1271.2.2.3.0.14

Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):

snmptrapd -f -Lo -c /dev/null authCommunity log public

Example snmptrapd log entry:

zoo11-linux.zoo [UDP: [192.168.30.111]:54154->[192.168.30.10]:162]:
  DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (476656522) 55 days, 4:02:45.22
  SNMPv2-MIB::snmpTrapOID.0 = OID: CIENA-CES-MODULE-MIB::cienaCesModuleProtectionModeHotNotification

Start monitoring Ciena Carrier Ethernet switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-MODULE-MIB::cienaCesModuleProtectionModeHotNotification OID value, configure state conditions and alerts, and monitor any Ciena Carrier Ethernet switches from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.2cienaCesNotificationsCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.2.3cienaCesModuleMIBNotificationPrefixCIENA-CES-MODULE-MIB
1.3.6.1.4.1.1271.2.2.3.0cienaCesModuleMIBNotificationsCIENA-CES-MODULE-MIB
1.3.6.1.4.1.1271.2.2.3.0.14cienaCesModuleProtectionModeHotNotificationCIENA-CES-MODULE-MIB