All MIBs › CIENA-CES-MGMT-INTERFACE-MIB › cienaCesInetMgmtInterfaceDomain
cienaCesInetMgmtInterfaceDomain
Module: CIENA-CES-MGMT-INTERFACE-MIB
OID (symbolic): CIENA-CES-MGMT-INTERFACE-MIB::cienaCesInetMgmtInterfaceDomain
OID (numeric): 1.3.6.1.4.1.1271.2.1.27.1.1.1.1.8
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Specifies the management interface domain.
What is cienaCesInetMgmtInterfaceDomain?
This object specifies which management domain the interface belongs to: unknown(1), a virtual switch partition vs(2), or a VLAN vlan(3). It matters because it changes how the paired cienaCesInetMgmtInterfaceDomainId value should be read downstream, and on a multi-tenant Ciena box it tells the admin whether this management path is scoped to an isolated virtual switch or riding a shared VLAN. For example, a value of vlan(3) on a shared physical management port means the interface's traffic is actually isolated into a specific VLAN for out-of-band access rather than being tied to a virtual switch partition.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.27.1.1.1.1.8 snmpwalk -v2c -c public <target> CIENA-CES-MGMT-INTERFACE-MIB::cienaCesInetMgmtInterfaceDomain
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.27.1.1.1.1.8.1 snmpget -v2c -c public <target> CIENA-CES-MGMT-INTERFACE-MIB::cienaCesInetMgmtInterfaceDomain.1
Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-MGMT-INTERFACE-MIB::cienaCesInetMgmtInterfaceDomain OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.1271 | ciena | CIENA-SMI |
| 1.3.6.1.4.1.1271.2 | cienaCes | CIENA-SMI |
| 1.3.6.1.4.1.1271.2.1 | cienaCesConfig | CIENA-SMI |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.1271.2.1.27 | cienaCesMgmtInterfaceMIB | CIENA-CES-MGMT-INTERFACE-MIB |
| 1.3.6.1.4.1.1271.2.1.27.1 | cienaCesMgmtInterfaceMIBObjects | CIENA-CES-MGMT-INTERFACE-MIB |
| 1.3.6.1.4.1.1271.2.1.27.1.1 | cienaCesMgmtInterface | CIENA-CES-MGMT-INTERFACE-MIB |
| 1.3.6.1.4.1.1271.2.1.27.1.1.1 | cienaCesInetMgmtInterfaceTable | CIENA-CES-MGMT-INTERFACE-MIB |
| 1.3.6.1.4.1.1271.2.1.27.1.1.1.1 | cienaCesInetMgmtInterfaceEntry | CIENA-CES-MGMT-INTERFACE-MIB |
| 1.3.6.1.4.1.1271.2.1.27.1.1.1.1.8 | cienaCesInetMgmtInterfaceDomain | CIENA-CES-MGMT-INTERFACE-MIB |