| OID symbolic | OID numeric | Type | Access | Description |
| broadsoft | 1.3.6.1.4.1.6431 | | | This is the System Management Information structure for the
Broadsoft enterprise. |
| broadworks | 1.3.6.1.4.1.6431.1 | | | |
| STR bwActiveSoftwareVersion | 1.3.6.1.4.1.6431.1.1.2.1.3 | DisplayString | read-only | Gives the version of the active software version. An operator can change the active software version by setting this field. |
| INT bwAdminState | 1.3.6.1.4.1.6431.1.1.2.1.4 | INTEGER | read-write | Server admin state. 0- Lock, 1- Locking, 2- Unlock, 3- ShuttingDown, 4- Stopped, 5- Forced Lock |
| INT bwAlarmThresholdControl | 1.3.6.1.4.1.6431.1.1.3.3.1.1.11 | INTEGER | read-write | This scalar controls the life cycle of the threshold. Setting this threshold to create(3) using an unused index creates a row with the specified index. Setting it with an already used index has no effect. Setting this threshold to delete(2) removes the entry. |
| bwAlarmThresholdEntry | 1.3.6.1.4.1.6431.1.1.3.3.1.1 | | not-accessible | This row contains information on a particular alarm threshold |
| U32 bwAlarmThresholdIndex | 1.3.6.1.4.1.6431.1.1.3.3.1.1.1 | Unsigned32 | read-only | This integer represents the index of an alarm threshold in the system |
| I32 bwAlarmThresholdMaxNumTrapsPerTimePeriod | 1.3.6.1.4.1.6431.1.1.3.3.1.1.3 | Integer32 | read-write | The maximum number of traps that the system outputs per sliding time period. If set to 0 (zero), the alarm is suppressed and the system does not output any trap for this alarm filter. |
| INT bwAlarmThresholdMinimumSeverity | 1.3.6.1.4.1.6431.1.1.3.3.1.1.10 | INTEGER | read-write | This is the minimum alarm severity under which alarms start to be discarded. |
| STR bwAlarmThresholdName | 1.3.6.1.4.1.6431.1.1.3.3.1.1.2 | DisplayString | read-write | The name of an alarm or DEFAULT if the threshold applies to all alarms in the system |
| I32 bwAlarmThresholdProblemTextVarNum1 | 1.3.6.1.4.1.6431.1.1.3.3.1.1.5 | Integer32 | read-write | To further refine a threshold, specify the position number of the variable data within the alarm problem text (1, 2, 3, etc.) that together with the alarm name, define the actual threshold. For example, if the alarm has five problem text variables: 1-deviceName, 2-deviceAddress, 3-devicePort, 4-errorType, 5-errorCode, and if the alarm threshold is to limit the number of traps for a given deviceName, devicePort, and errorType, then bwAlarmThresholdProblemTextVarNum1 should be set to 1, bwAlarmThresholdProblemTextVarNum2 should be set to 3, and bwAlarmThresholdProblemTextVarNum3 should be set to 4. To ignore filtering based on problem text variables, set to 0 (zero). |
| I32 bwAlarmThresholdProblemTextVarNum2 | 1.3.6.1.4.1.6431.1.1.3.3.1.1.6 | Integer32 | read-write | To further refine a threshold, specify the position number of the variable data within the alarm problem text (1, 2, 3, etc.) that together with the alarm name, define the actual threshold. For example, if the alarm has five problem text variables: 1-deviceName, 2-deviceAddress, 3-devicePort, 4-errorType, 5-errorCode, and if the alarm threshold is to limit the number of traps for a given deviceName, devicePort, and errorType, then bwAlarmThresholdProblemTextVarNum1 should be set to 1, bwAlarmThresholdProblemTextVarNum2 should be set to 3, and bwAlarmThresholdProblemTextVarNum3 should be set to 4. To ignore filtering based on problem text variables, set to 0 (zero). |
| I32 bwAlarmThresholdProblemTextVarNum3 | 1.3.6.1.4.1.6431.1.1.3.3.1.1.7 | Integer32 | read-write | To further refine a threshold, specify the position number of the variable data within the alarm problem text (1, 2, 3, etc.) that together with the alarm name, define the actual threshold. For example, if the alarm has five problem text variables: 1-deviceName, 2-deviceAddress, 3-devicePort, 4-errorType, 5-errorCode, and if the alarm threshold is to limit the number of traps for a given deviceName, devicePort, and errorType, then bwAlarmThresholdProblemTextVarNum1 should be set to 1, bwAlarmThresholdProblemTextVarNum2 should be set to 3, and bwAlarmThresholdProblemTextVarNum3 should be set to 4. To ignore filtering based on problem text variables, set to 0 (zero). |
| I32 bwAlarmThresholdProblemTextVarNum4 | 1.3.6.1.4.1.6431.1.1.3.3.1.1.8 | Integer32 | read-write | To further refine a threshold, specify the position number of the variable data within the alarm problem text (1, 2, 3, etc.) that together with the alarm name, define the actual threshold. For example, if the alarm has five problem text variables: 1-deviceName, 2-deviceAddress, 3-devicePort, 4-errorType, 5-errorCode, and if the alarm threshold is to limit the number of traps for a given deviceName, devicePort, and errorType, then bwAlarmThresholdProblemTextVarNum1 should be set to 1, bwAlarmThresholdProblemTextVarNum2 should be set to 3, and bwAlarmThresholdProblemTextVarNum3 should be set to 4. To ignore filtering based on problem text variables, set to 0 (zero). |
| I32 bwAlarmThresholdProblemTextVarNum5 | 1.3.6.1.4.1.6431.1.1.3.3.1.1.9 | Integer32 | read-write | To further refine a threshold, specify the position number of the variable data within the alarm problem text (1, 2, 3, etc.) that together with the alarm name, define the actual threshold. For example, if the alarm has five problem text variables: 1-deviceName, 2-deviceAddress, 3-devicePort, 4-errorType, 5-errorCode, and if the alarm threshold is to limit the number of traps for a given deviceName, devicePort, and errorType, then bwAlarmThresholdProblemTextVarNum1 should be set to 1, bwAlarmThresholdProblemTextVarNum2 should be set to 3, and bwAlarmThresholdProblemTextVarNum3 should be set to 4. To ignore filtering based on problem text variables, set to 0 (zero). |
| bwAlarmThresholdTable | 1.3.6.1.4.1.6431.1.1.3.3.1 | | not-accessible | Table of all the thresholds set against alarms in the system |
| I32 bwAlarmThresholdTimePeriodInSeconds | 1.3.6.1.4.1.6431.1.1.3.3.1.1.4 | Integer32 | read-write | The time period used for threshold calculation, in seconds. |
| INT bwCounterThresholdControl | 1.3.6.1.4.1.6431.1.1.3.1.1.1.8 | INTEGER | read-write | This scalar controls the life cycle of the threshold. Setting this counter to create(3) using an unused index creates a row with the specified index. Setting it with an already used index has no effect. Setting this counter to delete(2) removes the entry. |
| G32 bwCounterThresholdCurrentValue | 1.3.6.1.4.1.6431.1.1.3.1.1.1.6 | Gauge32 | read-only | The threshold value at which the next alarm will be generated |
| STR bwCounterThresholdDescription | 1.3.6.1.4.1.6431.1.1.3.1.1.1.2 | DisplayString | read-write | A description for this threshold. |
| bwCounterThresholdEntry | 1.3.6.1.4.1.6431.1.1.3.1.1.1 | | not-accessible | This row contains information on a particular counter threshold |
| U32 bwCounterThresholdIndex | 1.3.6.1.4.1.6431.1.1.3.1.1.1.1 | Unsigned32 | read-only | This integer represents the index of a counter threshold in the system |
| I32 bwCounterThresholdInitialValue | 1.3.6.1.4.1.6431.1.1.3.1.1.1.4 | Integer32 | read-write | The initial counter threshold value |
| STR bwCounterThresholdName | 1.3.6.1.4.1.6431.1.1.3.1.1.1.3 | DisplayString | read-write | The name of a counter. |
| I32 bwCounterThresholdOffsetValue | 1.3.6.1.4.1.6431.1.1.3.1.1.1.5 | Integer32 | read-write | The offset to be added to the current threshold value once an alarm has been sent |
| INT bwCounterThresholdSeverity | 1.3.6.1.4.1.6431.1.1.3.1.1.1.7 | INTEGER | read-write | The severity of the alarm to be sent |
| bwCounterThresholdTable | 1.3.6.1.4.1.6431.1.1.3.1.1 | | not-accessible | Table of all the thresholds set against counters in the system |
| INT bwGaugeThresholdControl | 1.3.6.1.4.1.6431.1.1.3.2.1.1.7 | INTEGER | read-write | This scalar controls the life cycle of the threshold. Setting this gauge to delete(2) removes the entry. |
| STR bwGaugeThresholdDescription | 1.3.6.1.4.1.6431.1.1.3.2.1.1.2 | DisplayString | read-write | A description for this threshold. |
| bwGaugeThresholdEntry | 1.3.6.1.4.1.6431.1.1.3.2.1.1 | | not-accessible | This row contains information on a particular gauge threshold |
| U32 bwGaugeThresholdIndex | 1.3.6.1.4.1.6431.1.1.3.2.1.1.1 | Unsigned32 | read-only | This integer represents the index of a gauge threshold in the system |
| STR bwGaugeThresholdName | 1.3.6.1.4.1.6431.1.1.3.2.1.1.3 | DisplayString | read-write | The name of a gauge. |
| I32 bwGaugeThresholdNotifyHigh | 1.3.6.1.4.1.6431.1.1.3.2.1.1.5 | Integer32 | read-write | The gauge value at which an alarm will be generated when the gauge value reaches or crosses the NotifyLow level in a falling direction. Subsequent similar crossings of the NotifyLow level will not generate an alarm until the gauge has reached or crossed the corresponding NotifyHigh level. |
| I32 bwGaugeThresholdNotifyLow | 1.3.6.1.4.1.6431.1.1.3.2.1.1.4 | Integer32 | read-write | The gauge value at which an alarm will be generated when the gauge value reaches or crosses the NotifyHigh level in a rising direction. Subsequent similar crossings of the NotifyHigh level will not generate an alarm until the gauge has reached or crossed the corresponding NotifyLow level. |
| INT bwGaugeThresholdSeverity | 1.3.6.1.4.1.6431.1.1.3.2.1.1.6 | INTEGER | read-write | The severity of the alarm to be sent |
| bwGaugeThresholdTable | 1.3.6.1.4.1.6431.1.1.3.2.1 | | not-accessible | Table of all the thresholds set against gauges in the system |
| INT bwManagedObjectsAdminState | 1.3.6.1.4.1.6431.1.1.2.3.1.1.5 | INTEGER | read-write | The administrative state of a managed object controlled by BroadWorks. 0- Lock, 1- locking, 2- Unlock |
| bwManagedObjectsEntry | 1.3.6.1.4.1.6431.1.1.2.3.1.1 | | not-accessible | This row contains information on a particular sub-managed object |
| U32 bwManagedObjectsIndex | 1.3.6.1.4.1.6431.1.1.2.3.1.1.1 | Unsigned32 | read-only | This integer represents the a managed object index in the system |
| STR bwManagedObjectsName | 1.3.6.1.4.1.6431.1.1.2.3.1.1.2 | DisplayString | read-only | The name of a managed object controlled by BroadWorks |
| INT bwManagedObjectsOperationalState | 1.3.6.1.4.1.6431.1.1.2.3.1.1.6 | INTEGER | read-only | The operational state of a managed object controlled by BroadWorks. 0- Enabled, 1- Disabled |
| STR bwManagedObjectsProtocol | 1.3.6.1.4.1.6431.1.1.2.3.1.1.3 | DisplayString | read-only | The protocol supported by a managed object controlled by BroadWorks |
| bwManagedObjectsTable | 1.3.6.1.4.1.6431.1.1.2.3.1 | | not-accessible | Table of all sub-managed objects under BroadWorks control |
| STR bwManagedObjectsType | 1.3.6.1.4.1.6431.1.1.2.3.1.1.4 | DisplayString | read-only | The type of a managed object controlled by BroadWorks |
| bwMoBasicCompliance | 1.3.6.1.4.1.6431.1.1.20.2.1 | | | BroadWorks Common managed object MIB compliance |
| bwMoDeviceGroup | 1.3.6.1.4.1.6431.1.1.20.1.3 | | | This group defines the counters used to manage the access or network devices monitored by this managed object. |
| bwMoReserveGroup | 1.3.6.1.4.1.6431.1.1.20.1.10 | | | MIB reserved section. |
| bwMoServerGroup | 1.3.6.1.4.1.6431.1.1.20.1.1 | | | This group defines managed object server attributes. |
| bwMoSoftwareVersionsGroup | 1.3.6.1.4.1.6431.1.1.20.1.2 | | | This group defines the software version attributes for the managed object. |
| bwMoThresholdsGroup | 1.3.6.1.4.1.6431.1.1.20.1.4 | | | This group defines the threshold control for this managed object. |
| bwMtcMibCompliancy | 1.3.6.1.4.1.6431.1.1.20.2 | | | |
| bwMtcMibConformance | 1.3.6.1.4.1.6431.1.1.20 | | | |
| bwMtcMibGroups | 1.3.6.1.4.1.6431.1.1.20.1 | | | |
| INT bwOperationalState | 1.3.6.1.4.1.6431.1.1.2.1.5 | INTEGER | read-only | Server operational state. 0- Enabled, 1- Disabled |
| INT bwRedundancyType | 1.3.6.1.4.1.6431.1.1.2.1.2 | INTEGER | read-only | Gives the broadworks server redundancy type: { Primary | Secondary | NotRedundant } |
| INT bwReservedScalar | 1.3.6.1.4.1.6431.1.1.10.1 | INTEGER | read-only | This is a reserved counter |
| INT bwResetServer | 1.3.6.1.4.1.6431.1.1.2.1.6 | INTEGER | read-write | Remotely reset the BroadWorks server. The reset action kicks in when the counter is set to 1. |
| STR bwRevertBackupLocation | 1.3.6.1.4.1.6431.1.1.2.1.9 | DisplayString | read-write | Gives the location of the backup file to use if using the revert option of the reset command. |
| STR bwServerType | 1.3.6.1.4.1.6431.1.1.2.1.1 | DisplayString | read-only | Gives the broadworks server type: { Application Server | Network Server | Media Server | Relay Server } |
| STR bwSoftwarePatchBundle | 1.3.6.1.4.1.6431.1.1.2.2.3.1.8 | DisplayString | read-only | Patch Bundle name of the patch. |
| bwSoftwarePatchEntry | 1.3.6.1.4.1.6431.1.1.2.2.3.1 | | not-accessible | This row contains information on a particular braodworks patch installed on the server |
| INT bwSoftwarePatchHistNewState | 1.3.6.1.4.1.6431.1.1.2.2.5.1.4 | INTEGER | read-only | The new state of the patch. |
| bwSoftwarePatchHistoryEntry | 1.3.6.1.4.1.6431.1.1.2.2.5.1 | | not-accessible | Entry of the patch history table containing history of operations applied to patches. |
| U32 bwSoftwarePatchHistoryIndex | 1.3.6.1.4.1.6431.1.1.2.2.5.1.1 | Unsigned32 | read-only | This integer an index of a patch operation history. |
| bwSoftwarePatchHistoryTable | 1.3.6.1.4.1.6431.1.1.2.2.5 | | not-accessible | This table contains information about all operation performed on patches. |
| STR bwSoftwarePatchHistPatchName | 1.3.6.1.4.1.6431.1.1.2.2.5.1.2 | DisplayString | read-only | The name of the patch against which the operation was applied. |
| STR bwSoftwarePatchHistTimeStamp | 1.3.6.1.4.1.6431.1.1.2.2.5.1.3 | DisplayString | read-only | The time stamp of the patch operation. |
| bwSoftwarePatchImpactedFileEntry | 1.3.6.1.4.1.6431.1.1.2.2.6.1 | | not-accessible | Entry of the patch impacted file table containing information about files modified by patches. |
| STR bwSoftwarePatchImpactedFileFileName | 1.3.6.1.4.1.6431.1.1.2.2.6.1.3 | DisplayString | read-only | The name of an impacted file. |
| U32 bwSoftwarePatchImpactedFileIndex | 1.3.6.1.4.1.6431.1.1.2.2.6.1.1 | Unsigned32 | read-only | This integer an index of an impacted file/patch name. |
| STR bwSoftwarePatchImpactedFilePatchName | 1.3.6.1.4.1.6431.1.1.2.2.6.1.2 | DisplayString | read-only | The name of the patch. |
| bwSoftwarePatchImpactedFileTable | 1.3.6.1.4.1.6431.1.1.2.2.6 | | not-accessible | This table contains information about files modified by the patches applied on the system. |
| U32 bwSoftwarePatchIndex | 1.3.6.1.4.1.6431.1.1.2.2.3.1.1 | Unsigned32 | read-only | This integer an index of a patch installed in the system |
| STR bwSoftwarePatchInstallDate | 1.3.6.1.4.1.6431.1.1.2.2.3.1.5 | DisplayString | read-only | This field was obsoleted in BroadWorks release 14.0. |
| STR bwSoftwarePatchName | 1.3.6.1.4.1.6431.1.1.2.2.3.1.3 | DisplayString | read-only | Patch name. |
| INT bwSoftwarePatchOperation | 1.3.6.1.4.1.6431.1.1.2.2.3.1.7 | INTEGER | read-write | This field was obsoleted in BroadWorks release 14.0. |
| INT bwSoftwarePatchState | 1.3.6.1.4.1.6431.1.1.2.2.3.1.6 | INTEGER | read-only | The state of the patch. |
| bwSoftwarePatchTable | 1.3.6.1.4.1.6431.1.1.2.2.3 | | not-accessible | This table has an entry per service packs installed for each sofware versions |
| STR bwSoftwarePatchType | 1.3.6.1.4.1.6431.1.1.2.2.3.1.4 | DisplayString | read-only | Patch type.
This field was obsoleted in BroadWorks release 14.0. |
| STR bwSoftwarePatchVersionName | 1.3.6.1.4.1.6431.1.1.2.2.3.1.2 | DisplayString | read-only | The name of a software load for which this patch applies.
This field was obsoleted in BroadWorks release 14.0. |
| bwSoftwareThirdPartyEntry | 1.3.6.1.4.1.6431.1.1.2.2.4.1 | | not-accessible | This row contains information on an installed 3rd party software version |
| U32 bwSoftwareThirdPartyIndex | 1.3.6.1.4.1.6431.1.1.2.2.4.1.1 | Unsigned32 | read-only | This integer represents the a group index in the system |
| STR bwSoftwareThirdPartyName | 1.3.6.1.4.1.6431.1.1.2.2.4.1.2 | DisplayString | read-only | The name of a software load for which this service pack applies |
| INT bwSoftwareThirdPartyStatus | 1.3.6.1.4.1.6431.1.1.2.2.4.1.4 | INTEGER | read-only | The status of a 3rd party software version. |
| bwSoftwareThirdPartyTable | 1.3.6.1.4.1.6431.1.1.2.2.4 | | not-accessible | This table has an entry for third party software version used by the BroadWorks server |
| STR bwSoftwareThirdPartyVersion | 1.3.6.1.4.1.6431.1.1.2.2.4.1.3 | DisplayString | read-only | A 3rd party software version id |
| bwSoftwareVersionEntry | 1.3.6.1.4.1.6431.1.1.2.2.2.1 | | not-accessible | This row contains information on a particular braodworks software version installed on the server |
| U32 bwSoftwareVersionIndex | 1.3.6.1.4.1.6431.1.1.2.2.2.1.1 | Unsigned32 | read-only | This integer represents the a group index in the system |
| STR bwSoftwareVersionInstallDate | 1.3.6.1.4.1.6431.1.1.2.2.2.1.3 | DisplayString | read-only | Installation date for this software version. |
| STR bwSoftwareVersionName | 1.3.6.1.4.1.6431.1.1.2.2.2.1.2 | DisplayString | read-only | The name of a software load installed on the server. |
| INT bwSoftwareVersionStatus | 1.3.6.1.4.1.6431.1.1.2.2.2.1.4 | INTEGER | read-only | The status of a software version. |
| bwSoftwareVersionTable | 1.3.6.1.4.1.6431.1.1.2.2.2 | | not-accessible | This table has an entry per software version installed on the server |
| bwSubComponentEntry | 1.3.6.1.4.1.6431.1.1.2.1.7.1 | | not-accessible | This row contains information about a software component in the system |
| U32 bwSubComponentIndex | 1.3.6.1.4.1.6431.1.1.2.1.7.1.1 | Unsigned32 | read-only | This integer represents the a software component index in the system |
| STR bwSubComponentInfo | 1.3.6.1.4.1.6431.1.1.2.1.7.1.3 | DisplayString | read-only | Displays status information about the component |
| STR bwSubComponentName | 1.3.6.1.4.1.6431.1.1.2.1.7.1.2 | DisplayString | read-only | The name of an exposed subcomponent |
| bwSubComponentTable | 1.3.6.1.4.1.6431.1.1.2.1.7 | | not-accessible | This table exposes some key BroadWorks server sub components. It may or may not be empty depending on the server |
| STR bwTargetSoftwareVersion | 1.3.6.1.4.1.6431.1.1.2.1.8 | DisplayString | read-write | Gives the target software version. If the server is reset, the active server software version will be updated. |
| INT bwUpdateSoftwareVersionTable | 1.3.6.1.4.1.6431.1.1.2.2.1 | INTEGER | read-write | This counter is used to reload the installed software table. To do so, just set this register to 1 (reload) |
| common | 1.3.6.1.4.1.6431.1.1 | | | |
| managedObjects | 1.3.6.1.4.1.6431.1.1.2 | | | |
| moDeviceModule | 1.3.6.1.4.1.6431.1.1.2.3 | | | |
| moServerModule | 1.3.6.1.4.1.6431.1.1.2.1 | | | |
| moSoftwareVersionModule | 1.3.6.1.4.1.6431.1.1.2.2 | | | |
| reservedModule | 1.3.6.1.4.1.6431.1.1.10 | | | |
| thAlarmModule | 1.3.6.1.4.1.6431.1.1.3.3 | | | |
| thCounterModule | 1.3.6.1.4.1.6431.1.1.3.1 | | | |
| thGaugeModule | 1.3.6.1.4.1.6431.1.1.3.2 | | | |
| thresholds | 1.3.6.1.4.1.6431.1.1.3 | | | |