BroadworksMaintenance :: bwAlarmThresholdProblemTextVarNum5

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsBroadworksMaintenancebwAlarmThresholdProblemTextVarNum5

bwAlarmThresholdProblemTextVarNum5

Module: BroadworksMaintenance

OID (symbolic): BroadworksMaintenance::bwAlarmThresholdProblemTextVarNum5

OID (numeric): 1.3.6.1.4.1.6431.1.1.3.3.1.1.9

Node type: OBJECT-TYPE

Type: Integer32

Access: read-write

Description: To further refine a threshold, specify the position number of the variable data within the alarm problem text (1, 2, 3, etc.) that together with the alarm name, define the actual threshold. For example, if the alarm has five problem text variables: 1-deviceName, 2-deviceAddress, 3-devicePort, 4-errorType, 5-errorCode, and if the alarm threshold is to limit the number of traps for a given deviceName, devicePort, and errorType, then bwAlarmThresholdProblemTextVarNum1 should be set to 1, bwAlarmThresholdProblemTextVarNum2 should be set to 3, and bwAlarmThresholdProblemTextVarNum3 should be set to 4. To ignore filtering based on problem text variables, set to 0 (zero).

What is bwAlarmThresholdProblemTextVarNum5?

Holds the position, within the alarm's problem-text variable list, of a fifth variable used (together with the alarm name) to further narrow which occurrences this threshold applies to. A value of 0 disables filtering on this variable slot.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6431.1.1.3.3.1.1.9
snmpwalk -v2c -c public <target> BroadworksMaintenance::bwAlarmThresholdProblemTextVarNum5

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.6431.1.1.3.3.1.1.9.1
snmpget -v2c -c public <target> BroadworksMaintenance::bwAlarmThresholdProblemTextVarNum5.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.6431.1.1.3.3.1.1.9.1 i <value>

Start monitoring BroadSoft BroadWorks VoIP application server with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BroadworksMaintenance::bwAlarmThresholdProblemTextVarNum5 OID value, configure state conditions and alerts, and monitor any BroadSoft BroadWorks VoIP application server from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6431broadsoftBroadworksFault
1.3.6.1.4.1.6431.1broadworksBroadworksFault
1.3.6.1.4.1.6431.1.1commonBroadworksFault
Numeric OIDNameModule
1.3.6.1.4.1.6431.1.1.3thresholdsBroadworksMaintenance
1.3.6.1.4.1.6431.1.1.3.3thAlarmModuleBroadworksMaintenance
1.3.6.1.4.1.6431.1.1.3.3.1bwAlarmThresholdTableBroadworksMaintenance
1.3.6.1.4.1.6431.1.1.3.3.1.1bwAlarmThresholdEntryBroadworksMaintenance
1.3.6.1.4.1.6431.1.1.3.3.1.1.9bwAlarmThresholdProblemTextVarNum5BroadworksMaintenance