BDFB-MIB :: bdfbTotalBusCurrent

MIB Reference — IPNetwork Monitor · Updated September 21, 2026

All MIBs › BDFB-MIB › bdfbTotalBusCurrent

bdfbTotalBusCurrent

Module: BDFB-MIB

OID (symbolic): BDFB-MIB::bdfbTotalBusCurrent

OID (numeric): 1.3.6.1.4.1.885.5.2.1.2

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Ttotal Bus Current.

What is bdfbTotalBusCurrent?

This OID tracks the total current drawn from the main bus. High values indicate heavy power consumption. Example: a value of 150 indicates 150 amperes total current is flowing from the bus.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.885.5.2.1.2
snmpwalk -v2c -c public <target> BDFB-MIB::bdfbTotalBusCurrent

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.885.5.2.1.2.1
snmpget -v2c -c public <target> BDFB-MIB::bdfbTotalBusCurrent.1

Start monitoring Emerson/ESNA mini-BDFB DC power distribution units with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BDFB-MIB::bdfbTotalBusCurrent OID value, configure state conditions and alerts, and monitor any Emerson/ESNA mini-BDFB DC power distribution units from a single console.

How to Use in IPNetwork Monitor

Select an Emerson/ESNA mini-BDFB DC power distribution unit as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type bdfbTotalBusCurrent into the Find box to locate it in the OID tree, then select it and click OK. It reports the ttotal Bus Current. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if the value drifts significantly from its normal baseline, since an unexpected change often points to a real underlying issue. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.885emersonESNABDFB-MIB
1.3.6.1.4.1.885.5bdfbMIBBDFB-MIB
1.3.6.1.4.1.885.5.2bdfbStatusBDFB-MIB
1.3.6.1.4.1.885.5.2.1bdfbMeasurementBDFB-MIB
1.3.6.1.4.1.885.5.2.1.2bdfbTotalBusCurrentBDFB-MIB