All MIBs › AdaptecArrayController-MIB
Category: Fibre Channel and Storage, Vendor: Adaptec
Description: Manages Adaptec RAID array controllers, providing logical drive status, physical drive health, and rebuild progress monitoring.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is AdaptecArrayController-MIB?
AdaptecArrayController-MIB is Adaptec's enterprise MIB for managing its hardware RAID array controllers, used to track the health and configuration of disk arrays attached to a server. Per its short description it covers logical drive status, physical drive health, and RAID rebuild progress -- squarely a hardware-status MIB for storage subsystems. It is used specifically to monitor hardware status: detecting a failed or degraded physical disk, a logical volume that has dropped out of its optimal state, and tracking the percentage progress of an active RAID rebuild after a disk replacement. As a storage-controller MIB it typically sits alongside, and is polled together with, a host's standard hardware MIBs (e.g., Host Resources MIB) for a complete view of server health. It is deployed on servers fitted with Adaptec SCSI/SAS RAID controllers in data center and enterprise server environments. Engineers can download the AdaptecArrayController-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in AdaptecArrayController-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Adaptec RAID array controller
- server with Adaptec storage adapter
Monitoring Examples
A storage administrator would poll the logical-drive status table to confirm each array is in an optimal state rather than degraded or failed, and check the corresponding physical-drive health table to identify which physical disk triggered a degraded array. During a disk swap, the rebuild-progress object would be polled periodically to confirm the rebuild is advancing and estimate time to completion. No sample object names were provided in the source data, so exact table/leaf names are described generically based on the module's stated scope.
What Can Be Monitored
- logical drive status
- physical drive health/failure state
- RAID rebuild progress
- array configuration
This MIB depends on
Related MIBs
Imported Objects
From RFC-1212
| OBJECT-TYPE |
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| enterprises |
From RFC1213-MIB
| DisplayString |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| adaptec | 1.3.6.1.4.1.795 | |||
| products | 1.3.6.1.4.1.795.3 | |||
| adaptecArrayController | 1.3.6.1.4.1.795.3.5 | |||
| NTF aacDriveLetterChange | 1.3.6.1.4.1.795.3.5.0.1 | A Drive Letter Changed on controller $1 for container $2. | ||
| NTF aacFailoverChange | 1.3.6.1.4.1.795.3.5.0.2 | A change in failover assignments occured on controller $1. | ||
| NTF aacContainerStateChange | 1.3.6.1.4.1.795.3.5.0.3 | A container changed its state on controller $1. Container : $2. | ||
| NTF aacFileSystemChange | 1.3.6.1.4.1.795.3.5.0.4 | A file system change has occured on container $2 on controller $1. | ||
| NTF aacGeneralContainerFailure | 1.3.6.1.4.1.795.3.5.0.6 | An unknown error occured on container $2 on adapter $1. | ||
| NTF aacMirrorNotMirroring | 1.3.6.1.4.1.795.3.5.0.7 | The container $2 on controller $1 is no longer in the mirroring state. | ||
| NTF aacMirrorFailureNoSpace | 1.3.6.1.4.1.795.3.5.0.8 | A failover operation for controller $1 container $2 failed because there was not enough space available on the failover device. | ||
| NTF aacMirrorFailureNoUnmirror | 1.3.6.1.4.1.795.3.5.0.9 | The container $2 on controller $1 could not be unmirrored. | ||
| NTF aacMirrorFailoverStarted | 1.3.6.1.4.1.795.3.5.0.10 | A mirror failover operation started on controller $1 for container $2. | ||
| NTF aacMirrorFailoverFailed | 1.3.6.1.4.1.795.3.5.0.11 | A failover operation on controller $1 failed for container $2. | ||
| NTF aacMirrorNoFailoverAssigned | 1.3.6.1.4.1.795.3.5.0.12 | There is no failover device assigned to container $2 on controller $1. | ||
| NTF aacMirrorDriveFailure | 1.3.6.1.4.1.795.3.5.0.13 | A drive that was part of the mirror set (container) $2 failed. This occurred on controller $1. | ||
| NTF aacRaidRebuildStart | 1.3.6.1.4.1.795.3.5.0.14 | A rebuild operation started on controller $1 for container $2. | ||
| NTF aacRaidRebuildRestart | 1.3.6.1.4.1.795.3.5.0.15 | A rebuild operation was restarted on controller $1 for container $2. | ||
| NTF aacRaidDriveFailure | 1.3.6.1.4.1.795.3.5.0.16 | A drive that was part of the RAID set (container) $2 failed. This occurred on controller $1. | ||
| NTF aacRaidNoFailover | 1.3.6.1.4.1.795.3.5.0.17 | There is no failover device assigned to container $2 on controller $1. | ||
| NTF aacRaidNoSpace | 1.3.6.1.4.1.795.3.5.0.18 | A failover operation for controller $1 container $2 failed because there is not enough space available on the failover device. | ||
| NTF aacSnapshotContainerAlmostFull | 1.3.6.1.4.1.795.3.5.0.19 | The snapshot container $2 on controller $1 is almost full. | ||
| NTF aacSnapshotContainerFull | 1.3.6.1.4.1.795.3.5.0.20 | The snapshot container $2 on controller $1 is full. | ||
| NTF aacRaidRebuildComplete | 1.3.6.1.4.1.795.3.5.0.21 | The rebuild operation on controller $1 for container $2 has completed. | ||
| NTF aacDeviceFailure | 1.3.6.1.4.1.795.3.5.0.22 | A device has failed. Controller $1. Bus $2. Id $3 Lun $4. | ||
| NTF aacControllerResume | 1.3.6.1.4.1.795.3.5.0.23 | The controller $1 resumed normal I/O operations. | ||
| NTF aacInterfaceUp | 1.3.6.1.4.1.795.3.5.0.24 | The AAC management interface is up. | ||
| NTF aacBatteryReconditionRequired | 1.3.6.1.4.1.795.3.5.0.25 | The controller $1 requires battery reconditioning. | ||
| NTF aacEnclosureGeneralError | 1.3.6.1.4.1.795.3.5.0.26 | An enclosure connected to controller $1 has reported an error. | ||
| NTF aacEnclosureFanError | 1.3.6.1.4.1.795.3.5.0.27 | An enclosure connected to controller $1 has reported a fan failure. | ||
| NTF aacEnclosurePowerSupplyError | 1.3.6.1.4.1.795.3.5.0.28 | An enclosure connected to controller $1 has reported a power supply failure. | ||
| NTF aacEnclosureTempAbnormal | 1.3.6.1.4.1.795.3.5.0.29 | An enclosure connected to controller $1 has reported an abnormal temperature reading. | ||
| NTF aacEnclosureTempOver | 1.3.6.1.4.1.795.3.5.0.30 | An enclosure connected to controller $1 has reported a temperature reading above the user threshold. | ||
| NTF aacBatteryDead | 1.3.6.1.4.1.795.3.5.0.31 | The battery connected to controller $1 is dead. | ||
| NTF aacBatteryImproving | 1.3.6.1.4.1.795.3.5.0.32 | The battery connected to controller $1 is improving. | ||
| NTF aacBatteryDegrading | 1.3.6.1.4.1.795.3.5.0.33 | The battery connected to controller $1 has lost charge. | ||
| NTF aacBatteryGood | 1.3.6.1.4.1.795.3.5.0.34 | The controller $1 reports that its battery is good. | ||
| NTF aacControllerPaused | 1.3.6.1.4.1.795.3.5.0.35 | The controller $1 has been paused. | ||
| NTF aacContainerCreated | 1.3.6.1.4.1.795.3.5.0.36 | Container $2 has been created on controller $1. | ||
| NTF aacContainerDeleted | 1.3.6.1.4.1.795.3.5.0.37 | Container $2 has been deleted on controller $1. | ||
| NTF aacDeviceFailurePredictionThresholdExceeded | 1.3.6.1.4.1.795.3.5.0.38 | A device reported that its Failure Prediction Threshold had been exceeded. Controller $1. Bus $2. Id $3 Lun $4. | ||
| NTF aacDeviceFailurePredictionTest | 1.3.6.1.4.1.795.3.5.0.39 | A Failure Prediction Threshold test occured. Controller $1. Bus $2. Id $3. Lun $4. | ||
| NTF aacDeviceWarning | 1.3.6.1.4.1.795.3.5.0.40 | A Device issued a warning. Controller $1. Bus $2. Id $3 Lun $4. | ||
| NTF aacDeviceTemperatureWarning | 1.3.6.1.4.1.795.3.5.0.41 | A Device issued a abnormal temperature warning. Controller $1. Bus $2. Id $3 Lun $4. | ||
| NTF aacDeviceDegradedWarning | 1.3.6.1.4.1.795.3.5.0.42 | A device reported that its status is degraded. Controller $1. Bus $2. Id $3 Lun $4. | ||
| NTF aacDeviceFailurePredictionConfigurationChanged | 1.3.6.1.4.1.795.3.5.0.43 | The failure prediction configuration changed for a device. Controller $1. Bus $2. Id $3 Lun $4. | ||
| STR adaptecArrayControllerSoftwareVersion | 1.3.6.1.4.1.795.3.5.1 | DisplayString | read-only | Version information for the Adaptec Array Controller Software Suite. |
| INT adaptecArrayControllerAdapterNumber | 1.3.6.1.4.1.795.3.5.2 | INTEGER | read-only | The Number of Adaptec Array Controllers present in the system. |
| adaptecArrayControllerAdapterTable | 1.3.6.1.4.1.795.3.5.3 | not-accessible | A list of Adaptec Array Controller entries. The number of entries is given by AdaptecArrayControllerAdapterNumber. | |
| adaptecArrayControllerAdapterEntry | 1.3.6.1.4.1.795.3.5.3.1 | not-accessible | Descriptive and Status Information for an Adaptec Array Controller. | |
| INT adaptecArrayControllerAdapterIndex | 1.3.6.1.4.1.795.3.5.3.1.1 | INTEGER | read-only | A unique index into the AdaptecArrayControllerAdapterTable. This ranges between 1 and the value of AdaptecArrayControllerAdapterNumber. |
| STR adaptecArrayControllerAdapterDescription | 1.3.6.1.4.1.795.3.5.3.1.2 | DisplayString | read-only | The Adaptec Array Controller description for this adapter. |
| STR adaptecArrayControllerAdapterType | 1.3.6.1.4.1.795.3.5.3.1.3 | DisplayString | read-only | The model name of this Adaptec Array Controller. |
| STR adaptecArrayControllerAdapterVersion | 1.3.6.1.4.1.795.3.5.3.1.4 | DisplayString | read-only | The hardware and software version string for this Adaptec Array Controller. |
| INT adaptecArrayControllerAdapterChannelCount | 1.3.6.1.4.1.795.3.5.3.1.5 | INTEGER | read-only | The number of channels supported by this Adaptec Array Controller. |
| INT adaptecArrayControllerAdapterStatus | 1.3.6.1.4.1.795.3.5.3.1.6 | INTEGER | read-only | The status of the controller. This status reflects the status of all containers and devices connected to the controller. |
| STR adaptecArrayControllerAdapterBiosVersion | 1.3.6.1.4.1.795.3.5.3.1.7 | DisplayString | read-only | The BIOS software version. |
| STR adaptecArrayControllerAdapterKernelVersion | 1.3.6.1.4.1.795.3.5.3.1.8 | DisplayString | read-only | The kernel software version. |
| STR adaptecArrayControllerAdapterMonitorVersion | 1.3.6.1.4.1.795.3.5.3.1.9 | DisplayString | read-only | The monitor software version. |
| STR adaptecArrayControllerAdapterHardwareVersion | 1.3.6.1.4.1.795.3.5.3.1.10 | DisplayString | read-only | The hardware version of the controller. |
| INT adaptecArrayControllerAdapterTotalMemory | 1.3.6.1.4.1.795.3.5.3.1.11 | INTEGER | read-only | The total amount of memory present in the controller expressed in bytes. |
| INT adaptecArrayControllerAdapterProgramMemory | 1.3.6.1.4.1.795.3.5.3.1.12 | INTEGER | read-only | The total amount of program memory present in the controller expressed in bytes. |
| INT adaptecArrayControllerAdapterBufferMemory | 1.3.6.1.4.1.795.3.5.3.1.13 | INTEGER | read-only | The total amount of buffer memory present in the controller expressed in bytes. |
| adaptecArrayControllerContainerTable | 1.3.6.1.4.1.795.3.5.4 | not-accessible | A list of Adaptec Array Controller Container Entries. There will one entry in this table for each container on the host. | |
| adaptecArrayControllerContainerEntry | 1.3.6.1.4.1.795.3.5.4.1 | not-accessible | Descriptive and status information for containers hosted by Adaptec Array Controller. | |
| INT adaptecArrayControllerContIndex | 1.3.6.1.4.1.795.3.5.4.1.1 | INTEGER | read-only | An internal index used to identify this container. |
| INT adaptecArrayControllerContAdapterIndex | 1.3.6.1.4.1.795.3.5.4.1.2 | INTEGER | read-only | An index into the AdaptecArrayControllerAdapterTable that specified the AAC Controller to which this container belongs. |
| INT adaptecArrayControllerContNumber | 1.3.6.1.4.1.795.3.5.4.1.3 | INTEGER | read-only | An AAC container ID. |
| INT adaptecArrayControllerContSize | 1.3.6.1.4.1.795.3.5.4.1.4 | INTEGER | read-only | The size of the container in megabytes. |
| STR adaptecArrayControllerContMountPoint | 1.3.6.1.4.1.795.3.5.4.1.5 | DisplayString | read-only | A string representing drive letters and mount points for the container. |
| STR adaptecArrayControllerContType | 1.3.6.1.4.1.795.3.5.4.1.6 | DisplayString | read-only | A string representing the container type. |
| STR adaptecArrayControllerContUsage | 1.3.6.1.4.1.795.3.5.4.1.7 | DisplayString | read-only | A string representing the container's usage. |
| INT adaptecArrayControllerContStatus | 1.3.6.1.4.1.795.3.5.4.1.8 | INTEGER | read-only | The current status of the container. If a container with a redundant container type is no longer redundant, its status will be marked as nonCritical. If the container is no longer on-line, its status will be marked as critical. |
| INT adaptecArrayControllerContStripeSize | 1.3.6.1.4.1.795.3.5.4.1.9 | INTEGER | read-only | The stripe or chunk size of the container in bytes. |
| adaptecArrayControllerDeviceTable | 1.3.6.1.4.1.795.3.5.5 | not-accessible | A list of devices that are attached to Adaptec Array Controllers that are connected to this host. | |
| adaptecArrayControllerDeviceEntry | 1.3.6.1.4.1.795.3.5.5.1 | not-accessible | Descriptive and status information for devices connected to Adaptec Array Controllers. | |
| INT adaptecArrayControllerDevIndex | 1.3.6.1.4.1.795.3.5.5.1.1 | INTEGER | read-only | An internally used identifier. |
| INT adaptecArrayControllerDevAdapterIndex | 1.3.6.1.4.1.795.3.5.5.1.2 | INTEGER | read-only | An index into the AdaptecArrayControllerAdapterTable that specified the AAC Controller to which this container belongs. |
| INT adaptecArrayControllerDevChannelId | 1.3.6.1.4.1.795.3.5.5.1.3 | INTEGER | read-only | The channel that the device is connected to. |
| INT adaptecArrayControllerDevId | 1.3.6.1.4.1.795.3.5.5.1.4 | INTEGER | read-only | The Device ID. |
| INT adaptecArrayControllerDevLogicalNumber | 1.3.6.1.4.1.795.3.5.5.1.5 | INTEGER | read-only | The Logical Device ID. |
| INT adaptecArrayControllerDevType | 1.3.6.1.4.1.795.3.5.5.1.6 | INTEGER | read-only | The Device Type. |
| STR adaptecArrayControllerDevVendor | 1.3.6.1.4.1.795.3.5.5.1.7 | DisplayString | read-only | The Device Vendor. |
| STR adaptecArrayControllerDevProduct | 1.3.6.1.4.1.795.3.5.5.1.8 | DisplayString | read-only | The Product Identifier. |
| STR adaptecArrayControllerDevRevision | 1.3.6.1.4.1.795.3.5.5.1.9 | DisplayString | read-only | The Product Revision. |
| INT adaptecArrayControllerDevBlocks | 1.3.6.1.4.1.795.3.5.5.1.10 | INTEGER | read-only | The Number of Blocks on the Device. |
| INT adaptecArrayControllerDevBytesPerBlock | 1.3.6.1.4.1.795.3.5.5.1.11 | INTEGER | read-only | The Number of Bytes Per Block on the Device. |
| STR adaptecArrayControllerDevUsage | 1.3.6.1.4.1.795.3.5.5.1.12 | DisplayString | read-only | The manner of usage by the Adaptec Array Controller. |
| INT adaptecArrayControllerDevStatus | 1.3.6.1.4.1.795.3.5.5.1.13 | INTEGER | read-only | The status of the device. |
| adaptecArrayControllerContainerToDeviceTable | 1.3.6.1.4.1.795.3.5.6 | not-accessible | A table used to correlate physical devices to containers. | |
| adaptecArrayControllerContainerToDeviceEntry | 1.3.6.1.4.1.795.3.5.6.1 | not-accessible | Each record of this type represents a row in a table that is used to list the physical devices that are used to make up a container. Each row includes an index into the container table to indicate the container that is being described, an index into the device table to show the device that is used by the container, and information about the size of the physical partition on the device. | |
| INT adaptecArrayControllerContainerToDeviceIndex | 1.3.6.1.4.1.795.3.5.6.1.1 | INTEGER | read-only | A unique index into the adaptecArrayControllerContainerToDeviceTable that can be used to identify each row in the table. |
| INT adaptecArrayControllerCDAdapterIndex | 1.3.6.1.4.1.795.3.5.6.1.2 | INTEGER | read-only | An index into the adapterArrayControllerTable indicating the controller hosting the container being described. |
| INT adaptecArrayControllerContainerIndex | 1.3.6.1.4.1.795.3.5.6.1.3 | INTEGER | read-only | An index into the adaptecArrayControllerContainerEntry table indicating the container being described. |
| INT adaptecArrayControllerDeviceIndex | 1.3.6.1.4.1.795.3.5.6.1.4 | INTEGER | read-only | An index into the AdaptecArrayControllerDeviceEntry table indicating the device on which a piece of the container resides. |
| INT adaptecArrayControllerPartitionOffsetLSW | 1.3.6.1.4.1.795.3.5.6.1.5 | INTEGER | read-only | The least significant 32 bits of the offset into the physical disk to the start of the partition that is used by the referenced container. |
| INT adaptecArrayControllerPartitionOffsetMSW | 1.3.6.1.4.1.795.3.5.6.1.6 | INTEGER | read-only | The most significant 32 bits of the offset into the physical disk to the start of the partition that is used by the referenced container. |
| INT adaptecArrayControllerPartitionSizeLSW | 1.3.6.1.4.1.795.3.5.6.1.7 | INTEGER | read-only | The least significant 32 bits of the size of partition on the device used by the referenced container. |
| INT adaptecArrayControllerPartitionSizeMSW | 1.3.6.1.4.1.795.3.5.6.1.8 | INTEGER | read-only | The most significant 32 bits of the size of partition on the device used by the referenced container. |
| adaptecArrayControllerEnclosureTable | 1.3.6.1.4.1.795.3.5.20 | not-accessible | A list of enclosures that are attached to Adaptec Array Controllers on this host. | |
| adaptecArrayControllerEnclosureEntry | 1.3.6.1.4.1.795.3.5.20.1 | not-accessible | Descriptive and status information for enclosures connected to Adaptec Array Controllers. | |
| INT adaptecArrayControllerEnclosureIndex | 1.3.6.1.4.1.795.3.5.20.1.1 | INTEGER | read-only | Index into the Enclosure table. |
| INT adaptecArrayControllerEnclosureAdapterIndex | 1.3.6.1.4.1.795.3.5.20.1.2 | INTEGER | read-only | An index into the AdaptecArrayControllerAdapterTable that specifies the AAC Controller to which this enclosure belongs. |
| INT adaptecArrayControllerEnclosureProcessorId | 1.3.6.1.4.1.795.3.5.20.1.3 | INTEGER | read-only | The enclosure processor ID assigned on a per adapter basis. |
| INT adaptecArrayControllerEnclosureType | 1.3.6.1.4.1.795.3.5.20.1.4 | INTEGER | read-only | Standard adhered to for this enclosure. |
| INT adaptecArrayControllerEnclosureNumberFans | 1.3.6.1.4.1.795.3.5.20.1.5 | INTEGER | read-only | Number of fans for this enclosure. |
| INT adaptecArrayControllerEnclosureNumberPowerSupplies | 1.3.6.1.4.1.795.3.5.20.1.6 | INTEGER | read-only | Number of power supplies for this enclosure. |
| INT adaptecArrayControllerEnclosureNumberSlots | 1.3.6.1.4.1.795.3.5.20.1.7 | INTEGER | read-only | Number of slots for this enclosure. |
| INT adaptecArrayControllerEnclosureDoorLock | 1.3.6.1.4.1.795.3.5.20.1.8 | INTEGER | read-only | Whether or not this enclosure has a host controllable door lock. |
| INT adaptecArrayControllerEnclosureNumberTemperatureSensors | 1.3.6.1.4.1.795.3.5.20.1.9 | INTEGER | read-only | Number of temperature sensors for this enclosure. |
| INT adaptecArrayControllerEnclosureSpeaker | 1.3.6.1.4.1.795.3.5.20.1.10 | INTEGER | read-only | Whether or not this enclosure has a speaker installed. |
| INT adaptecArrayControllerEnclosureBootTimeDiagnostic | 1.3.6.1.4.1.795.3.5.20.1.11 | INTEGER | read-only | Boot time diagnostic value for this enclosure. |
| STR adaptecArrayControllerEnclosureVendor | 1.3.6.1.4.1.795.3.5.20.1.12 | DisplayString | read-only | Vendor (from SCSI Inquiry) for this enclosure. |
| STR adaptecArrayControllerEnclosureProduct | 1.3.6.1.4.1.795.3.5.20.1.13 | DisplayString | read-only | Product (from SCSI Inquiry) for this enclosure. |
| STR adaptecArrayControllerEnclosureRevision | 1.3.6.1.4.1.795.3.5.20.1.14 | DisplayString | read-only | Revision (from SCSI Inquiry) for this enclosure. |
| INT adaptecArrayControllerEnclosureIdLow | 1.3.6.1.4.1.795.3.5.20.1.15 | INTEGER | read-only | Unique ID number for this enclosure (least significant bits) (from SCSI Inquiry). |
| INT adaptecArrayControllerEnclosureIdHigh | 1.3.6.1.4.1.795.3.5.20.1.16 | INTEGER | read-only | Unique Id number for this enclosure (most significant bits) (from SCSI Inquiry). |
| STR adaptecArrayControllerEnclosureStandardRevision | 1.3.6.1.4.1.795.3.5.20.1.17 | DisplayString | read-only | Revision of standard adhered to for this enclosure (from SCSI Inquiry). |
| INT adaptecArrayControllerEnclosurePowerOnTime | 1.3.6.1.4.1.795.3.5.20.1.18 | INTEGER | read-only | Total number of power on minutes for this enclosure. |
| INT adaptecArrayControllerEnclosurePowerCycles | 1.3.6.1.4.1.795.3.5.20.1.19 | INTEGER | read-only | Total number of power cycles for this enclosure. |
| INT adaptecArrayControllerEnclosureSpeakerStatus | 1.3.6.1.4.1.795.3.5.20.1.20 | INTEGER | read-only | Speaker status (on/off only) for this enclosure. |
| INT adaptecArrayControllerEnclosureOverTemperature | 1.3.6.1.4.1.795.3.5.20.1.21 | INTEGER | read-only | Indicates whether internal temperature for this enclosure exceeds normal. |
| adaptecArrayControllerEnclosureFanTable | 1.3.6.1.4.1.795.3.5.21 | not-accessible | A list of enclosure fans and their status. | |
| adaptecArrayControllerEnclosureFanEntry | 1.3.6.1.4.1.795.3.5.21.1 | not-accessible | Status information for enclosure fans. | |
| INT adaptecArrayControllerEnclosureFanIndex | 1.3.6.1.4.1.795.3.5.21.1.1 | INTEGER | read-only | Index into the enclosure fan table. |
| INT adaptecArrayControllerEnclosureFanEnclosureIndex | 1.3.6.1.4.1.795.3.5.21.1.2 | INTEGER | read-only | Index into the enclosure table specifying which enclosure contains this fan. |
| INT adaptecArrayControllerEnclosureFanStatus | 1.3.6.1.4.1.795.3.5.21.1.3 | INTEGER | read-only | Status of this fan. |
| adaptecArrayControllerEnclosurePowerSupplyTable | 1.3.6.1.4.1.795.3.5.22 | not-accessible | A list of enclosure power supplies and their status. | |
| adaptecArrayControllerEnclosurePowerSupplyEntry | 1.3.6.1.4.1.795.3.5.22.1 | not-accessible | Status information for enclosure power supplies. | |
| INT adaptecArrayControllerEnclosurePowerSupplyIndex | 1.3.6.1.4.1.795.3.5.22.1.1 | INTEGER | read-only | Index into the enclosure power supply table. |
| INT adaptecArrayControllerEnclosurePowerSupplyEnclosureIndex | 1.3.6.1.4.1.795.3.5.22.1.2 | INTEGER | read-only | Index into the enclosure table specifying which enclosure contains this power supply. |
| INT adaptecArrayControllerEnclosurePowerSupplyStatus | 1.3.6.1.4.1.795.3.5.22.1.3 | INTEGER | read-only | Status of this power supply. |
| adaptecArrayControllerEnclosureDoorLockTable | 1.3.6.1.4.1.795.3.5.23 | not-accessible | A list of enclosure door locks and their status. | |
| adaptecArrayControllerEnclosureDoorLockEntry | 1.3.6.1.4.1.795.3.5.23.1 | not-accessible | Status information for enclosure door locks. | |
| INT adaptecArrayControllerEnclosureDoorLockIndex | 1.3.6.1.4.1.795.3.5.23.1.1 | INTEGER | read-only | Index into the enclosure door lock table. |
| INT adaptecArrayControllerEnclosureDoorLockEnclosureIndex | 1.3.6.1.4.1.795.3.5.23.1.2 | INTEGER | read-only | Index into the enclosure table specifying which enclosure contains this door lock. |
| INT adaptecArrayControllerEnclosureDoorLockSlot | 1.3.6.1.4.1.795.3.5.23.1.3 | INTEGER | read-only | Specifies the slot number for this door lock. |
| INT adaptecArrayControllerEnclosureDoorLockStatus | 1.3.6.1.4.1.795.3.5.23.1.4 | INTEGER | read-only | Status of this door lock. |
| adaptecArrayControllerEnclosureTemperatureSensorTable | 1.3.6.1.4.1.795.3.5.24 | not-accessible | A list of enclosure temperature sensors and their status. | |
| adaptecArrayControllerEnclosureTemperatureSensorEntry | 1.3.6.1.4.1.795.3.5.24.1 | not-accessible | Status information for enclosure temperature sensors. | |
| INT adaptecArrayControllerEnclosureTemperatureSensorIndex | 1.3.6.1.4.1.795.3.5.24.1.1 | INTEGER | read-only | Index into the enclosure temperature sensor table. |
| INT adaptecArrayControllerEnclosureTemperatureSensorEnclosureIndex | 1.3.6.1.4.1.795.3.5.24.1.2 | INTEGER | read-only | Index into the enclosure table specifying which enclosure contains this temperature sensor. |
| INT adaptecArrayControllerEnclosureTemperatureSensorOverTemperature | 1.3.6.1.4.1.795.3.5.24.1.3 | INTEGER | read-only | Specifies whether this temperature sensor has detected an over temperature condition. |
| INT adaptecArrayControllerEnclosureTemperatureSensorDegrees | 1.3.6.1.4.1.795.3.5.24.1.4 | INTEGER | read-only | Temperature registered by this sensor in degrees Fahrenheit. |
| adaptecArrayControllerEnclosureScsiIdTable | 1.3.6.1.4.1.795.3.5.25 | not-accessible | A list of enclosure SCSI Ids by slot. | |
| adaptecArrayControllerEnclosureScsiIdEntry | 1.3.6.1.4.1.795.3.5.25.1 | not-accessible | Scsi Id information for enclosure slots. | |
| INT adaptecArrayControllerEnclosureScsiIdIndex | 1.3.6.1.4.1.795.3.5.25.1.1 | INTEGER | read-only | Index into the enclosure Scsi Id table. |
| INT adaptecArrayControllerEnclosureScsiIdEnclosureIndex | 1.3.6.1.4.1.795.3.5.25.1.2 | INTEGER | read-only | Index into the enclosure table specifying which enclosure contains this slot. |
| INT adaptecArrayControllerEnclosureScsiIdSlot | 1.3.6.1.4.1.795.3.5.25.1.3 | INTEGER | read-only | Specifies the slot number for this Scsi Id. |
| INT adaptecArrayControllerEnclosureChannelId | 1.3.6.1.4.1.795.3.5.25.1.4 | INTEGER | read-only | Channel Id of device in this slot. |
| INT adaptecArrayControllerEnclosureScsiId | 1.3.6.1.4.1.795.3.5.25.1.5 | INTEGER | read-only | SCSI Id of device in this slot. |
| INT adaptecArrayControllerEnclosureLunId | 1.3.6.1.4.1.795.3.5.25.1.6 | INTEGER | read-only | Logical Unit Id of device in this slot. |
| adaptecArrayControllerEnclosureDeviceInsertionTable | 1.3.6.1.4.1.795.3.5.26 | not-accessible | A list of enclosure device insertion counts by slot. | |
| adaptecArrayControllerEnclosureDeviceInsertionEntry | 1.3.6.1.4.1.795.3.5.26.1 | not-accessible | Count information for enclosure device insertions. | |
| INT adaptecArrayControllerEnclosureDeviceInsertionIndex | 1.3.6.1.4.1.795.3.5.26.1.1 | INTEGER | read-only | Index into the enclosure device insertion lock table. |
| INT adaptecArrayControllerEnclosureDeviceInsertionEnclosureIndex | 1.3.6.1.4.1.795.3.5.26.1.2 | INTEGER | read-only | Index into the enclosure table specifying which enclosure contains this slot. |
| INT adaptecArrayControllerEnclosureDeviceInsertionSlot | 1.3.6.1.4.1.795.3.5.26.1.3 | INTEGER | read-only | Specifies the slot number for this device insertion count. |
| INT adaptecArrayControllerEnclosureDeviceInsertions | 1.3.6.1.4.1.795.3.5.26.1.4 | INTEGER | read-only | Number of device insertions for this slot. |
| adaptecArrayControllerEnclosureSlotStatusTable | 1.3.6.1.4.1.795.3.5.27 | not-accessible | A list of enclosure statuses by slot. | |
| adaptecArrayControllerEnclosureSlotStatusEntry | 1.3.6.1.4.1.795.3.5.27.1 | not-accessible | Status information for enclosure slots. | |
| INT adaptecArrayControllerEnclosureSlotStatusIndex | 1.3.6.1.4.1.795.3.5.27.1.1 | INTEGER | read-only | Index into the enclosure slot status table. |
| INT adaptecArrayControllerEnclosureSlotStatusEnclosureIndex | 1.3.6.1.4.1.795.3.5.27.1.2 | INTEGER | read-only | Index into the enclosure table specifying which enclosure contains this slot. |
| INT adaptecArrayControllerEnclosureSlotStatusSlot | 1.3.6.1.4.1.795.3.5.27.1.3 | INTEGER | read-only | Specifies the slot number for this slot. |
| INT adaptecArrayControllerEnclosureSlotStatus | 1.3.6.1.4.1.795.3.5.27.1.4 | INTEGER | read-only | Status of this slot. |
| adaptecArrayControllerTraps | 1.3.6.1.4.1.795.3.5.9000 | |||
| STR aacControllerId | 1.3.6.1.4.1.795.3.5.9000.1 | DisplayString | not-accessible | Controller ID for this trap. |
| INT aacContainerId | 1.3.6.1.4.1.795.3.5.9000.2 | INTEGER | not-accessible | Container ID for this trap. |
| INT aacBusId | 1.3.6.1.4.1.795.3.5.9000.3 | INTEGER | not-accessible | Bus ID for device referred to by this trap. |
| INT aacScsiId | 1.3.6.1.4.1.795.3.5.9000.4 | INTEGER | not-accessible | SCSI ID for device referred to by this trap. |
| INT aacLunId | 1.3.6.1.4.1.795.3.5.9000.5 | INTEGER | not-accessible | SCSI LUN ID for device referred to by this trap. |
| INT aacEnclosureProcessorId | 1.3.6.1.4.1.795.3.5.9000.6 | INTEGER | not-accessible | Enclosure processor ID for enclosure referred to by this trap. |
| INT aacComponentUnitId | 1.3.6.1.4.1.795.3.5.9000.7 | INTEGER | not-accessible | Component unit ID for enclosure referred to by this trap. |
RFC description
Adaptec vendor-private MIB for Adaptec RAID array controllers; manages disk arrays, physical drives, and battery status.
Start monitoring Adaptec RAID array controllers with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.