All MIBs › AXD301-SPVC-MIB › atmSoftPVpcRestart
atmSoftPVpcRestart
Module: AXD301-SPVC-MIB
OID (symbolic): AXD301-SPVC-MIB::atmSoftPVpcRestart
OID (numeric): 1.3.6.1.4.1.353.5.5.1.3.1.8
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description:
When the value is set to 'restart' the Soft PVCC is released if necessary and a new setup procedure is begun. As a result of this action, the atmSoftPVpcOperStatus object transitions to 'establishmentInProgress' (if not already in this state) and the atmSoftPVpcRetryFailures object is cleared
When the value is set to 'noop' no operation is performed. When read, the value 'noop' is returned.
What is atmSoftPVpcRestart?
A writable control that, when set to 'restart', releases the Soft PVPC if necessary and begins a new setup procedure, moving its operational status back to establishment in progress.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.353.5.5.1.3.1.8 snmpwalk -v2c -c public <target> AXD301-SPVC-MIB::atmSoftPVpcRestart
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.353.5.5.1.3.1.8.1 snmpget -v2c -c public <target> AXD301-SPVC-MIB::atmSoftPVpcRestart.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.353.5.5.1.3.1.8.1 i <value>
OID Breakdown
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | BIANCA-BRICK-PPP-MIB |
| 1.3.6 | dod | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1 | internet | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1.4 | private | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1.4.1 | enterprises | ANIROOT-MIB |
| 1.3.6.1.4.1.353 | atmForum | ATM-FORUM-SNMP-M4-MIB |
| 1.3.6.1.4.1.353.5 | atmForumNetworkManagement | ATM-FORUM-SNMP-M4-MIB |
| 1.3.6.1.4.1.353.5.5 | atmfSoftPvc | ATM-SOFT-PVC-MIB |
| 1.3.6.1.4.1.353.5.5.1 | atmSoftPvcMIB | ATM-SOFT-PVC-MIB |
| 1.3.6.1.4.1.353.5.5.1.3 | atmSoftPvcMIBConformance | ATM-SOFT-PVC-MIB |
| 1.3.6.1.4.1.353.5.5.1.3.1 | atmSoftPvcMIBCompliances | ATM-SOFT-PVC-MIB |
| 1.3.6.1.4.1.353.5.5.1.3.1.8 | atmSoftPVpcRestart | AXD301-SPVC-MIB |