All MIBs › Axd301Eva-OMS
Organization: Ericsson
Last Updated: 1999-01-01
Category: ATM
Description:
Monitors event and alarm objects within the Ericsson AXD 301 OMS management subsystem.
Imported Objects
From Axd301Comm-OMS
| ats | MODULE-IDENTITY |
From SNMPv2-SMI
| Counter32 | |
| Integer32 | |
| MODULE-IDENTITY | |
| OBJECT-TYPE |
From SNMPv2-TC
| DateAndTime | |
| DisplayString | |
| TEXTUAL-CONVENTION |
What Is Axd301Eva-OMS?
Axd301Eva-OMS is an Ericsson proprietary MIB (extending Axd301Comm-OMS) defining a minimal event/alarm stub for the Ericsson AXD301 ATM switch platform. Its objects cover the alarm-sending entity, an event index/time, and current alarm class, cause, severity, free-text information, fault ID, and X.733 (ITU-T standard alarm reporting) cause code. As a notification/status MIB it lets a management station decode an AXD301 alarm's standardized X.733 cause alongside vendor-specific detail. It is deployed on the Ericsson AXD301 ATM switch platform. Engineers can download the Axd301Eva-OMS file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in Axd301Eva-OMS. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
What Can Be Monitored
- alarm class, cause, and X.733 standardized cause code
Supported Devices
- Ericsson AXD301 ATM switch platform
Monitoring Examples
A management station decodes currentAlarmX733Cause alongside currentAlarmInformation to classify an AXD301 alarm using the standard X.733 taxonomy for correlation with other network elements.
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| axd301Eva | 1.3.6.1.4.1.193.183.3 | Ericsson AXD301 Event/Alarm OMS stub. | ||
| STR eventSender | 1.3.6.1.4.1.193.183.3.1 | DisplayString | read-only | Event sender identifier. |
| I32 eventIndex | 1.3.6.1.4.1.193.183.3.2 | Integer32 | read-only | Event index. |
| DAT eventTime | 1.3.6.1.4.1.193.183.3.3 | DateAndTime | read-only | Event timestamp. |
| I32 currentAlarmClass | 1.3.6.1.4.1.193.183.3.4 | Integer32 | read-only | Alarm class. |
| I32 currentAlarmCause | 1.3.6.1.4.1.193.183.3.5 | Integer32 | read-only | Alarm cause. |
| I32 currentAlarmSeverity | 1.3.6.1.4.1.193.183.3.6 | Integer32 | read-only | Alarm severity. |
| STR currentAlarmInformation | 1.3.6.1.4.1.193.183.3.7 | DisplayString | read-only | Alarm information. |
| I32 currentAlarmFaultId | 1.3.6.1.4.1.193.183.3.8 | Integer32 | read-only | Alarm fault ID. |
| I32 currentAlarmX733Cause | 1.3.6.1.4.1.193.183.3.9 | Integer32 | read-only | X.733 alarm cause. |
RFC description
Ericsson AXD301 event and alarm management stub for SPVC alarm severity and fault cause tracking.
Start monitoring Ericsson AXD 301 ATM switch (legacy) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.