All MIBs › AXD301-SPVC-MIB › atmScheduledSPVpcEntry
atmScheduledSPVpcEntry
Module: AXD301-SPVC-MIB
OID (symbolic): AXD301-SPVC-MIB::atmScheduledSPVpcEntry
OID (numeric): 1.3.6.1.4.1.193.183.11.1.1.1
Node type: OBJECT-TYPE
Access: not-accessible
Description:
Each entry in this table represents a scheduled Soft Permanent Virtual Path Connection (SPVPC) originating at a switch interface. The atmScheduledSPVpcLeafReference object must be set to 1 since point-to-multipoint Soft PVPC's are not supported.
When a timeout for the timer value defined in atmScheduledSPVpcOperationTime occurs, the operation indicated in atmScheduledSPVpcOperationIndicator will be performed. If the scheduled operation succeeds, the spvcScheduledConnectionEvent will be sent and the row will be destroyed. If the scheduled operation fails, the spvcScheduledConnectionAlarm will be sent and atmScheduledSPVpcOperStatus will be set to failedAtTimeout.
OID Breakdown
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | BIANCA-BRICK-PPP-MIB |
| 1.3.6 | dod | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1 | internet | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1.4 | private | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1.4.1 | enterprises | ANIROOT-MIB |
| 1.3.6.1.4.1.193 | ericsson | ANS-COMMON-MIB |
| 1.3.6.1.4.1.193.183 | ats | Axd301Comm-OMS |
| 1.3.6.1.4.1.193.183.11 | spvc | AXD301-SPVC-MIB |
| 1.3.6.1.4.1.193.183.11.1 | spvcMIBObjects | AXD301-SPVC-MIB |
| 1.3.6.1.4.1.193.183.11.1.1 | atmScheduledSPVpcTable | AXD301-SPVC-MIB |
| 1.3.6.1.4.1.193.183.11.1.1.1 | atmScheduledSPVpcEntry | AXD301-SPVC-MIB |