ATEN-SN0116A-SMI

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › ATEN-SN0116A-SMI

Category: SNMP Framework, Vendor: ATEN

Description: Defines the OID sub-tree structure for ATEN SN0116A serial console server MIB objects.

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is ATEN-SN0116A-SMI?

ATEN-SN0116A-SMI defines the OID sub-tree and managed objects for the ATEN SN0116A, a serial (RS-232) console server/port server product used for out-of-band access to other equipment's serial consoles. It exposes objects for RS-232 port configuration and user/session configuration, along with firmware version tracking and port alert notifications. Its monitoring value spans both software and hardware/status dimensions: administrators track imageCurrentVersion/imageNewVersion to know if a firmware upgrade is available or pending, watch active session objects to see who is connected to which serial port, and rely on portAlert traps to learn about a serial line fault or unexpected disconnect on a managed port. It depends on the ATEN-SMI root module for its OID placement in the ATEN enterprise tree. It is deployed in data centers and equipment racks where administrators need remote serial console access to routers, switches, or other gear via the SN0116A's RS-232 ports. Engineers can download the ATEN-SN0116A-SMI file directly to load it into their MIB browser.

IPNetwork Monitor allows you to monitor SNMP objects defined in ATEN-SN0116A-SMI. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • ATEN SN0116A serial console/port server

Monitoring Examples

An administrator would poll the rs232 port configuration objects to confirm baud rate/settings for each serial port, check the session table to see which usrcfg-defined user currently holds an active session on a given port, and compare imageCurrentVersion against imageNewVersion to know if firmware is out of date. A portAlert trap firing on a specific RS-232 port would indicate the connected device's console cable was unplugged or the line lost carrier detect.

What Can Be Monitored

  • RS-232 port configuration
  • active console sessions per port
  • user account configuration
  • current vs. available firmware version
  • port alert/fault trap events
Imported Objects

From ATEN-PRODUCTS-MIB

sn3101OBJECT-IDENTITY
OIDs

RFC description

ATEN serial network device (SN0116A) configuration and session management.