AT-GS950-8-MIB :: dot1qStaticMcastPort

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsAT-GS950-8-MIBdot1qStaticMcastPort

dot1qStaticMcastPort

Module: AT-GS950-8-MIB

OID (symbolic): AT-GS950-8-MIB::dot1qStaticMcastPort

OID (numeric): 1.3.6.1.4.1.207.1.4.165.116.7.1.3.4.1.1

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Indicates whether the port is a member or a forbidden member in the static multicast entry. 'addMember' - to add the port in the egress member-list. 'addForbidden' - to add the port in the forbidden member-list. 'delMember' - to remove the port from the egress member-list. 'delForbidden' - to remove the port from the forbidden member-list.

What is dot1qStaticMcastPort?

Controls whether a specific port is added to or removed from the egress member list or forbidden member list for a static multicast entry. This determines which ports are permitted or explicitly denied from receiving frames destined for the associated multicast address.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.207.1.4.165.116.7.1.3.4.1.1
snmpwalk -v2c -c public <target> AT-GS950-8-MIB::dot1qStaticMcastPort

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.207.1.4.165.116.7.1.3.4.1.1.1
snmpget -v2c -c public <target> AT-GS950-8-MIB::dot1qStaticMcastPort.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.207.1.4.165.116.7.1.3.4.1.1.1 i <value>

Start monitoring Allied Telesis AT-GS950 switch series with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the AT-GS950-8-MIB::dot1qStaticMcastPort OID value, configure state conditions and alerts, and monitor any Allied Telesis AT-GS950 switch series from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.207alliedTelesynAT-RG600-MIB
1.3.6.1.4.1.207.1productsAT-SMI-MIB
1.3.6.1.4.1.207.1.4swhubAtiEdgeSwitch-MIB
Numeric OIDNameModule
1.3.6.1.4.1.207.1.4.165at_GS9508v2AT-GS950-8-MIB
1.3.6.1.4.1.207.1.4.165.116l2BridgeAT-GS950-8-MIB
1.3.6.1.4.1.207.1.4.165.116.7dot1qQBridgeAT-GS950-8-MIB
1.3.6.1.4.1.207.1.4.165.116.7.1dot1qMIBObjectsAT-GS950-8-MIB
1.3.6.1.4.1.207.1.4.165.116.7.1.3dot1qStaticAT-GS950-8-MIB
1.3.6.1.4.1.207.1.4.165.116.7.1.3.4dot1qStaticMcastPortTableAT-GS950-8-MIB
1.3.6.1.4.1.207.1.4.165.116.7.1.3.4.1dot1qStaticMcastPortEntryAT-GS950-8-MIB
1.3.6.1.4.1.207.1.4.165.116.7.1.3.4.1.1dot1qStaticMcastPortAT-GS950-8-MIB