AT-GS950-24-MIB :: dot1wPktErrType

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsAT-GS950-24-MIBdot1wPktErrType

dot1wPktErrType

Module: AT-GS950-24-MIB

OID (symbolic): AT-GS950-24-MIB::dot1wPktErrType

OID (numeric): 1.3.6.1.4.1.207.1.4.167.119.2.4.1.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Type of invalid packet received in each of the port

What is dot1wPktErrType?

Identifies the type of invalid RSTP packet that was received on a port, providing context for packet error trap notifications. This read-only object helps diagnose protocol errors caused by malformed or unexpected RSTP frames.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.207.1.4.167.119.2.4.1.3
snmpwalk -v2c -c public <target> AT-GS950-24-MIB::dot1wPktErrType

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.207.1.4.167.119.2.4.1.3.1
snmpget -v2c -c public <target> AT-GS950-24-MIB::dot1wPktErrType.1

Start monitoring Allied Telesis smart switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the AT-GS950-24-MIB::dot1wPktErrType OID value, configure state conditions and alerts, and monitor any Allied Telesis smart switches from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.207alliedTelesynAT-RG600-MIB
1.3.6.1.4.1.207.1productsAT-SMI-MIB
1.3.6.1.4.1.207.1.4swhubAtiEdgeSwitch-MIB
Numeric OIDNameModule
1.3.6.1.4.1.207.1.4.167at_GS95024v3AT-GS950-24-MIB
1.3.6.1.4.1.207.1.4.167.119l2RstAT-GS950-24-MIB
1.3.6.1.4.1.207.1.4.167.119.2dot1wRstTrapsControlAT-GS950-24-MIB
1.3.6.1.4.1.207.1.4.167.119.2.4dot1wPortTrapNotificationTableAT-GS950-24-MIB
1.3.6.1.4.1.207.1.4.167.119.2.4.1dot1wPortTrapNotificationEntryAT-GS950-24-MIB
1.3.6.1.4.1.207.1.4.167.119.2.4.1.3dot1wPktErrTypeAT-GS950-24-MIB