All MIBs › AT-GS950-24-MIB › dot1sCistPortOperEdgeStatus
dot1sCistPortOperEdgeStatus
Module: AT-GS950-24-MIB
OID (symbolic): AT-GS950-24-MIB::dot1sCistPortOperEdgeStatus
OID (numeric): 1.3.6.1.4.1.207.1.4.167.118.1.6.1.10
Node type: OBJECT-TYPE
Type: TruthValue
Access: read-only
Description: The operational value of the Edge Port parameter. The object is initialized to the value of dot1sCistPortAdminEdgeStatus and is set FALSE on reception of a BPDU.
What is dot1sCistPortOperEdgeStatus?
Reports the current operational edge-port status of a spanning tree port, initialized from the administrative setting but automatically set to FALSE when a BPDU is received. This indicates whether the port is currently behaving as an edge port in practice.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.207.1.4.167.118.1.6.1.10 snmpwalk -v2c -c public <target> AT-GS950-24-MIB::dot1sCistPortOperEdgeStatus
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.207.1.4.167.118.1.6.1.10.1 snmpget -v2c -c public <target> AT-GS950-24-MIB::dot1sCistPortOperEdgeStatus.1
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> dot1sCistPortOperEdgeStatus.1
Start monitoring Allied Telesis smart switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the AT-GS950-24-MIB::dot1sCistPortOperEdgeStatus OID value, configure state conditions and alerts, and monitor any Allied Telesis smart switches from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.207 | alliedTelesyn | AT-RG600-MIB |
| 1.3.6.1.4.1.207.1 | products | AT-SMI-MIB |
| 1.3.6.1.4.1.207.1.4 | swhub | AtiEdgeSwitch-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.207.1.4.167 | at_GS95024v3 | AT-GS950-24-MIB |
| 1.3.6.1.4.1.207.1.4.167.118 | l2Mst | AT-GS950-24-MIB |
| 1.3.6.1.4.1.207.1.4.167.118.1 | dot1sMst | AT-GS950-24-MIB |
| 1.3.6.1.4.1.207.1.4.167.118.1.6 | dot1sCistPortTable | AT-GS950-24-MIB |
| 1.3.6.1.4.1.207.1.4.167.118.1.6.1 | dot1sCistPortEntry | AT-GS950-24-MIB |
| 1.3.6.1.4.1.207.1.4.167.118.1.6.1.10 | dot1sCistPortOperEdgeStatus | AT-GS950-24-MIB |