All MIBs › AT-GS950-24-MIB › dot1dRegenUserPriority
dot1dRegenUserPriority
Module: AT-GS950-24-MIB
OID (symbolic): AT-GS950-24-MIB::dot1dRegenUserPriority
OID (numeric): 1.3.6.1.4.1.207.1.4.167.116.6.1.2.2.1.2
Node type: OBJECT-TYPE
Type: Integer32
Access: read-write
Description: The Regenerated User Priority that the incoming User
Priority is mapped to for this port.
The value of this object MUST be retained across reinitializations of the management system.
What is dot1dRegenUserPriority?
Defines the remapped (regenerated) priority value that an incoming user priority is translated to on this port. This allows the bridge to reclassify ingress frame priorities before forwarding, and the mapping persists across reboots.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.207.1.4.167.116.6.1.2.2.1.2 snmpwalk -v2c -c public <target> AT-GS950-24-MIB::dot1dRegenUserPriority
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.207.1.4.167.116.6.1.2.2.1.2.1 snmpget -v2c -c public <target> AT-GS950-24-MIB::dot1dRegenUserPriority.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.207.1.4.167.116.6.1.2.2.1.2.1 i <value>
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> dot1dRegenUserPriority.1
Start monitoring Allied Telesis smart switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the AT-GS950-24-MIB::dot1dRegenUserPriority OID value, configure state conditions and alerts, and monitor any Allied Telesis smart switches from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.207 | alliedTelesyn | AT-RG600-MIB |
| 1.3.6.1.4.1.207.1 | products | AT-SMI-MIB |
| 1.3.6.1.4.1.207.1.4 | swhub | AtiEdgeSwitch-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.207.1.4.167 | at_GS95024v3 | AT-GS950-24-MIB |
| 1.3.6.1.4.1.207.1.4.167.116 | l2Bridge | AT-GS950-24-MIB |
| 1.3.6.1.4.1.207.1.4.167.116.6 | dot1dPBridge | AT-GS950-24-MIB |
| 1.3.6.1.4.1.207.1.4.167.116.6.1 | dot1dMIBObjects | AT-GS950-24-MIB |
| 1.3.6.1.4.1.207.1.4.167.116.6.1.2 | dot1dPriority | AT-GS950-24-MIB |
| 1.3.6.1.4.1.207.1.4.167.116.6.1.2.2 | dot1dUserPriorityRegenTable | AT-GS950-24-MIB |
| 1.3.6.1.4.1.207.1.4.167.116.6.1.2.2.1 | dot1dUserPriorityRegenEntry | AT-GS950-24-MIB |
| 1.3.6.1.4.1.207.1.4.167.116.6.1.2.2.1.2 | dot1dRegenUserPriority | AT-GS950-24-MIB |