AT-ENVMON-MIB :: envMonVoltageCurrent

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › AT-ENVMON-MIB › envMonVoltageCurrent

envMonVoltageCurrent

Module: AT-ENVMON-MIB

OID (symbolic): AT-ENVMON-MIB::envMonVoltageCurrent

OID (numeric): 1.3.6.1.4.1.207.8.4.4.3.10.2.1.4

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The current reading of this voltage rail in millivolts.

What is envMonVoltageCurrent?

This read-only integer reports the measured voltage on this rail in millivolts. It reflects real-time power supply health. A value of 12000 means 12.0 volts; a value of 11800 means 11.8 volts (slightly low).

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.207.8.4.4.3.10.2.1.4
snmpwalk -v2c -c public <target> AT-ENVMON-MIB::envMonVoltageCurrent

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.207.8.4.4.3.10.2.1.4.1
snmpget -v2c -c public <target> AT-ENVMON-MIB::envMonVoltageCurrent.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> envMonVoltageCurrent.1

Start monitoring Allied Telesis managed switches and routers with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the AT-ENVMON-MIB::envMonVoltageCurrent OID value, configure state conditions and alerts, and monitor any Allied Telesis managed switches and routers from a single console.

How to Use in IPNetwork Monitor

Select an Allied Telesis managed switch or router as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type envMonVoltageCurrent into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The current reading of this voltage rail in millivolts. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if the reading drifts outside the range expected for healthy operation, since an unexpected voltage swing often points to a power-supply or wiring issue. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.207alliedTelesynAT-RG600-MIB
1.3.6.1.4.1.207.8mibObjectAT-RG600-MIB
1.3.6.1.4.1.207.8.4brouterMibAT-SMI-MIB
1.3.6.1.4.1.207.8.4.4atRouterAT-SMI-MIB
1.3.6.1.4.1.207.8.4.4.3sysinfoAT-SMI-MIB
Numeric OIDNameModule
1.3.6.1.4.1.207.8.4.4.3.10envMonAT-ENVMON-MIB
1.3.6.1.4.1.207.8.4.4.3.10.2envMonVoltageTableAT-ENVMON-MIB
1.3.6.1.4.1.207.8.4.4.3.10.2.1envMonVoltageEntryAT-ENVMON-MIB
1.3.6.1.4.1.207.8.4.4.3.10.2.1.4envMonVoltageCurrentAT-ENVMON-MIB